Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Differential scanning calorimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigating Fast Scanning Calorimetry and Differential Scanning Calorimetry as Screening Tools for Thermoset Polymer Material Compatibility with Laser-Based Powder Bed Fusion

As additive manufacturing (AM) technology has developed and progressed, a constant topic of research in the area is expanding the library of materials to be used with these techniques. Among AM methods that utilize polymers, laser-based powder bed fusion (PBF-LB) has preferentially used thermoplastic polymers as its starting materials, but the deposition and material joining method employed in PBF-LB may also be compatible with powdered thermoset polymer precursors as feedstocks. To assess the compatibility of candidate thermosetting polymers and PBF-LB, characterization techniques and protocols that link fundamental material behavior to material behavior in the processing environment are needed. Therefore, the objectives of this work are to compare the curing behavior measured with two different calorimetry techniques that can operate in different heating rate regimes, differential scanning calorimetry (DSC) and fast scanning calorimetry (FSC), and to assess the capabilities of these techniques to act as materials screening tools for PBF-LB. A commercial polyester powder coating is used as a model material to evaluate the potential of obtaining complimentary information for material screening through a combination of calorimetry methods, and its non-isothermal curing behavior is measured at heating rates between 5 °C/min and 7500 °C/min. Curing exotherms are observed with both calorimetry techniques, and comparing the enthalpy associated with curing shows that incomplete curing occurs at higher heating rates, with relative conversion values of approximately 30%. The curing data are fit with two isoconversional models, Friedman and Starink, which show a reduced activation energy at higher heating rates as well, signifying a lower barrier to curing at the conditions used in the FSC experiments. Overall, the results of this work indicate that using these two calorimetry techniques as tiered screening tools can provide valuable information about how curing may proceed in PBF-LB and inform materials selection and design activities for additive manufacturing.

36 MATERIALS SCIENCE

Differential scanning calorimetry of coal

Differential scanning calorimetry studies performed during the first year of this project demonstrated the occurrence of exothermic reactions associated with the production of volatile matter in or near the plastic region. The temperature and magnitude of the exothermic peak were observed to be strongly affected by the heating rate, sample mass and, to a lesser extent, by sample particle size. Thermal properties also were found to be influenced by oxidation of the coal sample due to weathering effects.

Gold, P. I.

Differential Scanning Calorimetry (DSC) for planetary surface exploration

Differential Scanning Calorimetry (DSC) is the quantitative measurement of the enthalpic response of a material to a systematic change in temperature. In practice, the heat flow into or outward from a sample is measured as the sample is heated or cooled at a carefully controlled rate. DSC superficially resembles, but is not the same as differential thermal analysis (DTA), which is the measurement of temperature differences between a sample and reference material as the pair is heated or cooled. The fundamental properties measured by DSC are enthalpies and temperatures of phase transitions and constant-pressure heat capacities. Depending on instrument design and the nature of the sample, high-quality DSC analyses can be obtained on only a few milligrams of solid materials. DSC requires direct contact with the sample and generally degrades, if not destroys, the sample as a consequence of heating. In laboratory applications, it is common to subject the gaseous effluent from the DSC to analysis by a separate evolved-gas analyzer (EGA).

Gooding, James L.

Accurate Measurement of Heat Capacity by Differential Scanning Calorimetry

Experience with high quality heat capacity measurement by differential scanning calorimetry is summarized and illustrated, pointing out three major causes of error: (1) incompatible thermal histories of the sample, reference and blank runs; (2) unstable initial and final isotherms; (3) incompatible differences between initial and final isotherm amplitudes for sample, reference and blank runs. Considering these problems, it is shown for the case of polyoxymethylene that accuracies in heat capacity of 0.1 percent may be possible.

Source record

Applications of high pressure differential scanning calorimetry to aviation fuel thermal stability research

High pressure differential scanning calorimetry (DSC) was studied as an alternate method for performing high temperature fuel thermal stability research. The DSC was used to measure the heat of reaction versus temperature of a fuel sample heated at a programmed rate in an oxygen pressurized cell. Pure hydrocarbons and model fuels were studied using typical DSC operating conditions of 600 psig of oxygen and a temperature range from ambient to 500 C. The DSC oxidation onset temperature was determined and was used to rate the fuels on thermal stability. Kinetic rate constants were determined for the global initial oxidation reaction. Fuel deposit formation is measured, and the high temperature volatility of some tetralin deposits is studied by thermogravimetric analysis. Gas chromatography and mass spectrometry are used to study the chemical composition of some DSC stressed fuels.

Neveu, M. C.

Quantifying Uncertainties in Heat Capacity Measurements of Molten Salts Determined Using Differential Scanning Calorimetry

Uncertainty in specific heat capacity values of a molten salt determined by using differential scanning calorimetry (DSC) was assessed based on the precision of replicate measurements of heat flows used in the calculation and effects of corrections that are commonly made to heat flow measurements. The ratio method of determining heat capacity was applied using the results of replicate heat flow measurements made with two empty cells, a sapphire reference material, and three samples of a doped NaCl-UCl 3 salt mixture. Replicate measurements with empty cells were used to quantify the effects of system instabilities and sensitivities on the measured heat flows of sapphire and salt. The combined effects of uncertainties in individual heat flow measurements made with blank cells using this system were quantified to be 2.6 μV based on isothermal holds before and after the scan, with cell placement adding the greatest uncertainty. This value was used as the tolerance for accepting background-corrected heat flows measured with sapphire and salt to calculate the specific heat capacity. The acceptable heat flows measured for sapphire and salt over the temperature range of 540 to 725 °C resulted in calculated specific heat capacity values ranging from 0.53 to 0.91 J g −1 K −1 with an overall average value of 0.70 J g −1 K −1 and an uncertainty of 0.22 J g −1 K −1 at the 99 % confidence level. The combined uncertainty in the specific heat capacity masked detection of any effect of temperature or salt composition that occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Differential Scanning Calorimetry and Evolved Gas Analysis at Mars Ambient Conditions Using the Thermal Evolved Gas Analyzer (TEGA)

Differential Scanning Calorimetry (DSC) combined with evolved gas analysis (EGA) is a well developed technique for the analysis of a wide variety of sample types with broad application in material and soil sciences. However, the use of the technique for samples under conditions of pressure and temperature as found on other planets is one of current C development and cutting edge research. The Thermal Evolved Gas Analyzer (MGA), which was designed, built and tested at the University of Arizona's Lunar and Planetary Lab (LPL), utilizes DSC/EGA. TEGA, which was sent to Mars on the ill-fated Mars Polar Lander, was to be the first application of DSC/EGA on the surface of Mars as well as the first direct measurement of the volatile-bearing mineralogy in martian soil.

Musselwhite, D. S.

Differential Scanning Calorimetry and Evolved Gas Analysis at Mars Ambient Conditions Using the Thermal Evolved Gas Analyser (TEGA)

Differential Scanning Calorimetry (DSC) combined with evolved gas analysis (EGA) is a well developed technique for the analysis of a wide variety of sample types with broad application in material and soil sciences. However, the use of the technique for samples under conditions of pressure and temperature as found on other planets is one of current development and cutting edge research. The Thermal Evolved Gas Analyzer (TEGA), which was designed, built and tested at the University of Arizona's Lunar and Planetary Lab (LPL), utilizes DSC/EGA. TEGA, which was sent to Mars on the ill-fated Mars Polar Lander, was to be the first application of DSC/EGA on the surface of Mars as well as the first direct measurement of the volatile-bearing mineralogy in martian soil. Additional information is available in the original extended abstract.

Musselwhite, D. S.

Cure kinetics of epoxy matrix resin by differential scanning calorimetry

A study was made on the cure kinetics of an epoxy neat-resin (Narmco 5208) using Differential Scanning Calorimetry (DSC). Two interrelated analytical methods were applied to dynamic DSC data for evaluating the kinetic parameters, such as activation energy, E, the order of reaction, n, and the total heat of polymerization (or crosslinking), delta H sub t. The first method was proposed by Ellerstein (1968), and uses a thorough differential-integral analysis of a single DSC curve to evaluate the kinetic parameters. The second method was proposed by Kissinger (1957), and uses multiple DSC curves obtained at various heating rates to evaluate E regardless of n. Kinetic analysis of Narmco 5208 epoxy resin showed that the reaction order, n, is substantially affected by the rate of heating; i.e., n is approximately 2 at slow scan rates but is reduced to 1.5 at higher scan rates. The activation energy, E, is not affected by the scan rate, and the average value of E is 25.6 + or - 1.8 kcal/mole.

Cizmecioglu, M.

Laboratory Annealing Experiments Of Refractory Silicate Grain Analogs Using Differential Scanning Calorimetry

Exothermic reactions during the annealing of laboratory synthesized amorphous magnesium-bearing silicate particles used as grain analogs of cosmic dust were detected by differential scanning calorimetry (DSC) in air. With infrared spectroscopy and transmission electron microscopy, we show that cosmic dust could possibly undergo fusion to larger particles, with oxidation of magnesium silicide and crystallization of forsterite as exothermic reactions in the early solar system. The reactions begin at approximately 425, approximately 625, and approximately 1000 K, respectively, and the reaction energies (enthalpies) are at least 727, 4151, and 160.22 J per gram, respectively. During the crystallization of forsterite particles, the spectral evolution of the 10 micrometer feature from amorphous to crystalline was observed to begin at lower temperature than the crystallization temperature of 1003 K. During spectral evolution at lower temperature, nucleation and/or the formation of nanocrystallites of forsterite at the surface of the grain analogs was observed.

Kimura, Yuki

High Temperature Dielectric Properties and Differential Scanning Calorimetry of Lunar Simulants

To guide development of microwave process technology that could be used during in situ construction on the Moon, we measured the high-temperature basic dielectric properties (εʹ and εʺ) of 17 lunar simulants and related materials. In order to confidently use these data one needs to understand the data’s strengths and weaknesses. Therefore, a goal of this publication is to provide insights into the comparative effects of sample composition, pre-treatments, experimental variables, high temperatures, and other factors on the measured response. The dielectric measurements were performed using the cavity perturbation method over a temperature range between room temperature to 1000 °C, or higher, and provided the real and imaginary components of permittivity at six frequencies. The utility of the original values was limited by the varying density of the pellets used in the measurement. Therefore, all of the εʹ and εʺ measurements at the frequency of 2466 MHz have been scaled to a constant density, 1.75 g/cm 3 . Here the data are presented as graphs chosen to aid analysis within and across simulant groups. To gain additional insight into the processes happening at the elevated temperatures in the dielectric measurements, heat capacity data was obtained using differential scanning calorimetry (DSC) on several of the simulant materials. Our data show that over the frequency range 397 MHz – 2985 MHz a material’s behavior does not greatly change, as compared to the scale of differences observed between lunar mare and highland simulants at high temperatures. For example at 1000 °C, the mare simulant JSC-1A absorbs 10 times more power than the highland simulant NUW-LHT-5M. We observe that as melting temperatures are reached both permittivity and dielectric loss rise non-linearly, helping to explain thermal runaway during microware heating. Our data show that even less than a few weight % of many non-lunar minerals, and the use of mixtures in simulants can affect the dielectric behavior at higher temperatures. A comparison of our results with published dielectric data for Apollo samples and with remote sensing of the Moon supports the conclusion the simulants and lunar material at room temperature have very similar dielectric values.

Differential Scanning Calorimetry

Solid-solid phase transitions determined by differential scanning calorimetry.

Data are presented to show that tris(hydroxymethyl)acetic acid, monochloropentaerythritol, monofluoropentaerythritol, difluoropentaerythritol, monoaminopentaerythritol, and diaminopentaerythritol exhibit solid-state transitions to a plastic crystalline state. Transitional enthalpies in many of these substances are lower than might be expected by analogy with related structures, suggesting that some configurational contributions to their entropy increments have been inhibited.

Murrill, E.