Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detectors and Experimental Techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Time-of-flight experiments for nuclear structure and astrophysics

Neutron-rich isotopes are atomic nuclei with a large neutron excess compared to their stable counter parts. Their study provides essential information to understand the properties of the nuclear interaction, and to model nuclear processes in extreme astrophysical environments where neutron-rich isotopes drive the chains of nuclear reactions. Experimentally, these unstable isotopes are difficult to study because of their short half-lives and low production yields at particle accelerator laboratories. The TOF-Bρ technique is a mass measurement technique specialized for experiments with fast beams of short-lived radioactive isotopes. In this project we used the technique for two experiments performed at the National Superconducting Cyclotron Laboratory to measure new masses of isotopes in the region of 112 Mo and 46 S. The experiments at the NSCL were complemented by the development of new timing radiation detectors and experimental techniques to improve the performance and reach of mass measurements on neutron-rich isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Test Beamline on Diamond Light Source

A Test beamline B16 has been built on the 3 GeV Diamond synchrotron radiation source. The beamline covers a wide photon energy range from 2 to 25 keV. The beamline is highly flexible and versatile in terms of the available beam size (a micron to 100 mm) and the range of energy resolution and photon flux; by virtue of its several operational modes, and the different inter-changeable instruments available in the experiments hutch. Diverse experimental configurations can be flexibly configured using a five-circle diffractometer, a versatile optics test bench, and a suite of detectors. Several experimental techniques including reflectivity, diffraction and imaging are routinely available. Details of the beamline and its measured performance are presented.

43 PARTICLE ACCELERATORS↗

CHARACTERIZATION OF SPATIAL HETEROGENIETIES IN DETECTOR GRADE CDZNTE

Synthetic Cd{sub 1-x}Zn{sub x}Te or 'CZT' crystals are highly suitable for the room temperature-based spectroscopy of gamma radiation. Structural/morphological heterogeneities within CZT, such as secondary phases that are thought to consist of Te metal and have detrimental impacts on detector performance. In this study, we used electron and X-ray-based imaging techniques to examine heterogeneous properties of detector grade CZT. Using experimental analytical techniques rather than arbitrary theoretical definitions, our study identifies two dominant secondary phase morphologies. The first consists of numerous empty, 20 {micro} m wide, pyramidal bodies (tetrahedra) or 'negative' crystals with trace quantities of particulate residue that exist as 65 nm sized particles containing Si, Cd, Zn, and Te. The other consists of 20 {micro}m hexagonal-shaped bodies, which are composites of metallic Te layers that contain a teardrop-shaped core of amorphous and polycrystalline CdZnTe which finally surrounds an irregular-shaped void.

36 MATERIALS SCIENCE↗

New Projections for Dark Matter Searches with Paleo-Detectors

Paleo-detectors are a proposed experimental technique to search for dark matter (DM). In lieu of the conventional approach of operating a tonne-scale real-time detector to search for DM-induced nuclear recoils, paleo-detectors take advantage of small samples of naturally occurring rocks on Earth that have been deep underground (≳5 km), accumulating nuclear damage tracks from recoiling nuclei for O(1)Gyr. Modern microscopy techniques promise the capability to read out nuclear damage tracks with nanometer resolution in macroscopic samples. Thanks to their O(1)Gyr integration times, paleo-detectors could constitute nuclear recoil detectors with keV recoil energy thresholds and 100 kilotonne-yr exposures. This combination would allow paleo-detectors to probe DM-nucleon cross sections orders of magnitude below existing upper limits from conventional direct detection experiments. In this article, we use improved background modeling and a new spectral analysis technique to update the sensitivity forecast for paleo-detectors. We demonstrate the robustness of the sensitivity forecast to the (lack of) ancillary measurements of the age of the samples and the parameters controlling the backgrounds, systematic mismodeling of the spectral shape of the backgrounds, and the radiopurity of the mineral samples. Specifically, we demonstrate that even if the uranium concentration in paleo-detector samples is 10−8 (per weight), many orders of magnitude larger than what we expect in the most radiopure samples obtained from ultra basic rock or marine evaporite deposits, paleo-detectors could still probe DM-nucleon cross sections below current limits. For DM masses ≲ 10 GeV/c2, the sensitivity of paleo-detectors could still reach down all the way to the conventional neutrino floor in a Xe-based direct detection experiment.

Baum, Sebastian (ORCID:0000000167929381)↗

KALYPSO: Linear array detector for high-repetition rate and real-time beam diagnostics

Synchrotrons and modern FEL light sources operate with bunch repetition rates in the MHz range. The profile of the electron beam inside the accelerator can be characterized with indirect experimental techniques where linear array detectors are employed to measure the emitted synchrotron radiation or the spectrum of a near-IR laser. To improve the performance of modern beam diagnostics we have developed KALYPSO, a detector system operating with a continuous frame rate of up to 2.7 MHz. To facilitate the integration in different experiments, a modular architecture has been adopted. Different semiconductor micro-strip sensors can be connected to front-end ASICs to optimize the quantum efficiency at different photon energies, ranging from visible light up to near-IR. The front-end electronics are integrated within an heterogeneous DAQ consisting of FPGAs and GPUs, which allows scientists to implement real-time data processing algorithms. The current version of the detector is in operation at the KARA synchrotron light source and at the European XFEL. Finally, in this contribution we present the detector architecture, the performance results and the on-going technical developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross sections for the production of fragments with Z greater than or equal to 8 by fragmentation of Z greater than or equal to 9 and less than or equal to 26 nuclei

Charge changing nuclear collisions in plastic nuclear track detectors were studied using a new experimental technique of automatic track measurement for etched tracks in plastic detectors. Partial cross sections for the production of fragments of charge Z approximately 8 were measured for projectile nuclei of charge 9 approximately Z approximately 26 in the detector material CR39 and in silver. for this purpose three independent experiments were performed using Bevalac beams. The first one was an exposure of a stack of CR39 plastic plates to 1.8 GeV/nucl. Ar-40 nuclei. The second one was an exposure of another CR39 stack of 1.7 GeV/nucl. Fe-56 projectiles. In the third experiment a mixed stack of CR39 plates and silver foils was irradiated with 1.7 GeV/nucl. Fe-56 nuclei. Thus the measurement of nuclear cross sections in a light target (CR39 = C12H18O7) and as well in a heavy target (silver) was possible.

Heinrich, W.↗

Laser Doppler velocimeter system simulation for sensing aircraft wake vortices. Part 3: The problem of reflection from the secondary mirror

Calculations are carried out to investigate the effects of obscuring the central portion of the secondary mirror. Two cases are treated: (1) a Gaussian distribution of reflectivity, and (2) a sharp-edged obscuration. Substantial reduction in reflection from the secondary mirror is found achievable, but the reduction was found highly sensitive to the form of the radial distribution of reflectivity. The total power reflected from the secondary mirror that is incident on the detector is estimated. Techniques for experimental testing of alleviation schemes are suggested.

Thomson, J. A. L.↗

The Cosmic Microwave Background: Detection and Interpretation of the First Light

A host of astrophysical observations suggest the early Universe was incredibly hot, dense, and homogeneous. A powerful and useful probe of this epoch is provided by the relic radiation, which we refer to today as the Cosmic Microwave Background (CMB). Precision maps of this light contain the earliest glimpse of the Universe after the Big Bang and signatures of the evolution of its contents. By exploiting these clues, constraints on the age, mass density, detailed composition, and geometry of the Universe can be made. A brief survey of the evolution of the radiometric and polarimetric imaging systems used in advancing our understanding of the early Universe will be reviewed. A survey of detector technologies, instrumentation techniques, and experimental challenges encountered in these efforts will be presented.

polarimetric imaging systems↗

Bayes and discovery

Objective Bayesian Hypothesis Testing approach is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent progress in the transition radiation detector techniques

A list of some of the major experimental achievements involving charged particles in the relativistic region are presented. With the emphasis mainly directed to the X-ray region, certain modes of application of the transition radiation for the identification and separation of relativistic charged particles are discussed. Some recent developments in detection techniques and improvements in detector performances are presented. Experiments were also carried out to detect the dynamic radiation, but no evidence of such an effect was observed.

Yuan, L. C. L.↗

Heterodyne method for high specificity gas detection.

This paper describes a new technique for measuring trace quantities of gases. The technique involves the use of a reference cell (containing a known amount of the gas being sought) and a sample cell (containing an unknown amount of the same gas) wherein the gas densities are modulated. Light passing through the two cells in sequence is modulated in intensity at the vibrational-rotational lines characteristic of the absorption spectrum for the gas of interest. Since the absorption process is nonlinear, modulating the two absorption cells at two different frequencies gives rise to a heterodyning effect, which in turn introduces sum and difference frequencies in the detected signal. Measuring the ratio of the difference frequency signal for example, to the signal introduced by the reference cell provides a normalized measure of the amount of the gas in the sample cell. The readings produced are thereby independent of source intensity, window transparency, and detector sensitivity. Experimental evaluation of the technique suggests that it should be applicable to a wide range of gases, that it should be able to reject spurious signals due to unwanted gases, and that it should be sensitive to concentrations of the order of 10 to the minus 8th power when used with a sample cell of only 20 cm length.

Dimeff, J.↗

Nuclear Structure Studies with Radioactive Ion Beams in the Mass A = 80 Region

An experimental program to measure spectroscopic properties of neutron-rich nuclei in the A = 80 region is underway at the Holifield Radioactive Ion Beam Facility. Our approach has been to get a comprehensive picture of the shell structure in this region by studying a series of properties of low lying states (E(2{sup +}), B(E2), g-factors and quadrupole moments). The beams, instrumentation and techniques developed specifically for this purpose have allowed us to systematically study the behavior of these observables along isotopic and isotonic chains using both stable and radioactive nuclei under almost identical experimental conditions. We have developed many techniques and detectors for in-beam gamma spectroscopy with radioactive ion beams. Most of the detectors can be used individually or in combination. Generally these detector systems have very large efficiencies. We give examples of their use from three recent experiments; namely, Coulomb excitation of n-rich nuclei along the N = 50 shell closure, the static quadrupole moment of the first 2{sup +} in {sup 78}Ge and g-factor measurements of n-rich isotopes near N = 50.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-BRE-07: Experimental Validation of a Lung SBRT Technique Using a Novel, True Volumetric Plenoptic-Plastic-Scintillator Detector

Purpose: Lung SBRT is being used by an increasing number of clinics, including our center which recently treated its first patient. In order to validate this technique, the 3D dose distribution of the SBRT plan was measured using a previously developed 3D detector based on plenoptic camera and plastic scintillator technology. The excellent agreement between the detector measurement and the expected dose from the treatment planning system Pinnacle{sup 3} shows great promise and amply justify the development of the technique. Methods: The SBRT treatment comprised 8 non-coplanar 6MV photon fields with a mean field size of 12 cm{sup 2} at isocentre and a total prescription dose of 12Gy per fraction for a total of 48Gy. The 3D detector was composed of a 10×10×10 cm{sup 2} EJ-260 water-equivalent plastic scintillator embedded inside a truncated cylindrical acrylic phantom of 10cm radius. The scintillation light was recorded using a static R5 light-field camera and the 3D dose was reconstructed at a 2mm resolution in all 3 dimensions using an iterative backprojection algorithm. Results: The whole 3D dose distribution was recorded at a rate of one acquisition per second. The mean absolute dose difference between the detector and Pinnacle{sup 3} was 1.3% over the region with more than 10% of the maximum dose. 3D gamma tests performed over the same region yield passing rates of 98.8% and 96.6% with criteria of 3%/1mm and 2%/1mm, respectively. Conclusion: Experimental results showed that our beam modeling and treatment planning system calculation was adequate for the safe administration of small field/high dose techniques such as SBRT. Moreover, because of the real-time capability of the detector, further validation of small field rotational, dynamic or gated technique can be monitored or verified by this system.

60 APPLIED LIFE SCIENCES↗

A Pulse Shape Analysis Technique for the MAJORANA Experiment

In order to achieve background count rates sufficiently low as to allow the observation of rare events such as neutrinoless double beta (0 ) decay, background suppression techniques are routinely employed. In this paper we present details of a novel Pulse Shape Analysis algorithm which allows single-site events such as 0 decay to be distinguished from multi site background events. The algorithm, which is based on the event by event 2 fitting of experimental signals to a basis data set of unique single site pulse shapes, has been developed through simulation studies and tested experimentally using a Broad Energy Germanium detector. It is found experimentally that the technique is able to successfully identify and reject 99% of multi site events in the single escape peak associated with the gamma decay of 208Tl, whilst maintaining a survival probability of 98% for '0 like' double escape peak events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The hunt for theta{sub 13} at the Daya Bay nuclear power plant

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is approx0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin{sup 2}2theta{sub 13}<0.01 with baseline uncertainties after 3 years of data taking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Directional detection of dark matter using solid-state quantum sensing

Next-generation dark matter (DM) detectors searching for weakly interacting massive particles (WIMPs) will be sensitive to coherent scattering from solar neutrinos, demanding an efficient background-signal discrimination tool. Directional detectors improve sensitivity to WIMP DM despite the irreducible neutrino background. Wide-bandgap semiconductors offer a path to directional detection in a high-density target material. A detector of this type operates in a hybrid mode. Here, the WIMP or neutrino-induced nuclear recoil is detected using real-time charge, phonon, or photon collection. The directional signal, however, is imprinted as a durable sub-micron damage track in the lattice structure. This directional signal can be read out by a variety of atomic physics techniques, from point defect quantum sensing to x-ray microscopy. In this Review, we present the detector principle as well as the status of the experimental techniques required for directional readout of nuclear recoil tracks. Specifically, we focus on diamond as a target material; it is both a leading platform for emerging quantum technologies and a promising component of next-generation semiconductor electronics. Based on the development and demonstration of directional readout in diamond over the next decade, a future WIMP detector will leverage or motivate advances in multiple disciplines toward precision dark matter and neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron lifetimes behavior analysis considering the two-region kinetic model in the IPEN/MB-01 reactor

This is a complementary work about the behavior analysis of the neutron lifetimes that was developed in the IPEN/MB-01 nuclear reactor facility. The macroscopic neutron noise technique was experimentally employed using pulse mode detectors for two stages of control rods insertion, where a total of twenty levels of subcriticality have been carried out. It was also considered that the neutron reflector density was treated as an additional group of delayed neutrons, being a sophisticated approach in the two-region kinetic theoretical model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Results from Recent NNSA and CEA Measurements of the 239 Pu(n, f) Prompt Fission Neutron Spectrum

The National Nuclear Security Administration (NNSA)/DP French Alternative Energies and Atomic Energy Commission (CEA)/DAM agreement on cooperation on fundamental science is a U.S.-French collaborative effort to combine intellectual and experimental resources and further the relevant nuclear science. Recently, both the NNSA and CEA experimental teams performed high-statistics measurements of the 239 Pu(n, f) prompt fission neutron spectrum (PFNS) at the Los Alamos Neutron Science Center, both of which were recently published in the journal Physical Review C. These separate measurements used the same experimental area and a common neutron detector array, but differ in many aspects, including background assessments, data acquisition systems and philosophies, fission detectors, and PFNS extraction techniques. Hence, some aspects of the experimental methods and associated uncertainties are highly correlated while others are independent. The results from both measurements broke new ground for PFNS measurements given their higher accuracy and more detailed study of corrections necessary for the measured quantity compared to existing literature measurements, and both will significantly impact PFNS nuclear data evaluations for the foreseeable future. Here, the focus of this work is to document a comparison of the results from these distinct measurements in terms of the acquired data, the PFNS results, and the measured average PFNS energies. While systematic differences between the PFNS results are present on the 1–3% level, the acquired data relative to each respective measurement at low incident neutron energies are in remarkable agreement, as are the conclusions regarding the magnitude and position of features in the PFNS relating to second-chance fission, third-chance fission, and pre-equilibrium neutron emission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗