Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-F-T-571: Objective Assessment of 3D Dosimetry for Flattened and Flattened Filter Free Stereotactic Rotational Delivery Using 729-Array Detector with Octavius 4D Phantom

Purpose: The purpose of this study was to assess the potential of 3D dosimetry for flattened and flattened filter free stereotactic rotational delivery in high definition MLC using 729-detector array with Octavius 4D phantom Methods: Twenty rapid arc plans were assessed for this study. For each patient two plans for 6X and 6FFF photon beams were generated with same prescription and critical organ constraints in Eclipse TPS version 13.0 using high definition MLC. Verification plans were generated in scanned Octavius 4D phantom in TPS. 3D dose measurements were collected from 729-ion chamber detector array in Octavius 4D phantom using verisoft software v 6.0. TPS calculated dose was compared with measured 3D dose in verisoft using the following gamma analysis parameters such as 3D volumetric, 3D planar and 2D global gamma in transverse, sagittal and coronal planes for 3mm/3% and 2mm/2% distance to agreement criteria.Passing rate and arithmetic mean of global gamma were analysed for 2D and 3D global gamma in all planes. Results: The average number of dose points passing rate for 2D global gamma with 3mm/3% criteria in transverse, sagittal and coronal planes was 99.06%±2.89%, 98.8%±0.88% and 99.06%±91%, respectively. For 2mm/2% criteria 97.86%±2.26%, 94.49± 2.64% and 94.34%±2.9% was observed. In 3D planar global gamma with 3mm/3% was 99.53%±0.49%, 98.93%±1.03% and 99.29%±1.29%, for 2mm 2% criteria was 97.50%±2.24%, 94.5%±2.5% and 95.38%±4.5%. The maximum arithmetic mean gamma deviation of 0.505%±0.13% was observed in coronal plane for 2D global gamma with 2mm/2% criteria. The 3D volumetric gamma passing rate was observed as 99.61%±0.433% for 3mm /3% and 95.91%±2.51% for 2mm/2%. Conclusion: The objective assessment of 3D dosimetry have demonstrated that the rotational delivery accuracy for flattened and flattened filter free stereotactic plans can be verified by using Octavius system comprising with 729 ion chamber array and Octavius 4D phantom.

60 APPLIED LIFE SCIENCES↗

Nuclear structure through moment measurements: Exploiting γ-ray detector arrays with ancillary detectors

Experimental methods to measure the magnetic moments of short-lived excited states in beams of rare isotopes are outlined. The emphasis is on the so-called High-Velocity Transient-Field (HVTF) and the Recoil in Vacuum (RIV) methods, and the role of γ-ray detector arrays with ancillary detectors. Insights into the structure of neutron-rich nuclei through such measurements on radioactive beams are discussed. Opportunities for the future development of these techniques, for applications to both stable and radioactive beams, are explored.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of the ORRUBA Silicon Detector Array

High quality radioactive beams have recently made possible the measurement of (d,p) reactions on unstable nuclei in inverse kinematics, which can yield information on the development of single-neutron structure away from stability, and are of astrophysical interest due to the proximity to suggested r-process paths. The Oak Ridge Rutgers University Barrel Array (ORRUBA) is a new high solid-angular coverage array, composed of two rings of silicon detectors, optimized for measuring (d,p) reactions. A partial implementation has been used to measure (d,p) reactions on nuclei around the N = 82 shell closure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of Detector Arrays for the SPT-3G Receiver

The South Pole Telescope third-generation (SPT-3G) receiver was installed during the austral summer of 2016–2017. It is designed to measure the cosmic microwave background across three frequency bands centered at 95, 150, and 220 GHz. The SPT-3G receiver has ten focal plane modules, each with 269 pixels. Each pixel features a broadband sinuous antenna coupled to a niobium microstrip transmission line. In-line filters define the desired band-passes before the signal is coupled to six bolometers with Ti/Au/Ti/Au transition edge sensors (three bands × two polarizations). In total, the SPT-3G receiver is composed of 16,000 detectors, which are read out using a 68 × frequency-domain multiplexing scheme. In this paper, we present the process employed in fabricating the detector arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed imaging at high x-ray energy: CdTe sensors coupled to charge-integrating pixel array detectors

Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we describe the hybridization of CdTe sensors to two different charge-integrating readout chips, the Keck PAD and the Mixed-Mode PAD (MM-PAD), both developed previously in our laboratory. The charge-integrating architecture of each of these PADs extends the instantaneous counting rate by many orders of magnitude beyond that obtainable with photon counting architectures. The Keck PAD chip consists of rapid, 8-frame, in-pixel storage elements with framing periods <150 ns. The second detector, the MM-PAD, has an extended dynamic range by utilizing an in-pixel overflow counter coupled with charge removal circuitry activated at each overflow. This allows the recording of signals from the single-photon level to tens of millions of x-rays/pixel/frame while framing at 1 kHz. Both detector chips consist of a 128×128 pixel array with (150 µm){sup 2} pixels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray source considerations in operation of digital detector arrays

Digital Detector Arrays (DDA) are increasingly replacing film in radiography applications. Standards exist for characterizing the performance of these detectors, and for using them in specific inspections. We have observed that the selection of the x-ray source to use with these detectors can also have a significant influence on the performance. We look at differences between standard, and micro-focus x-ray tubes, and end-window vs. side-window micro-focus tubes. We find that for best results, one must calibrate the DDA for the source settings used during an inspection. This is particularly true for variable-focus sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spiral biasing adaptor for use in Si drift detectors and Si drift detector arrays

A drift detector array, preferably a silicon drift detector (SDD) array, that uses a low current biasing adaptor is disclosed. The biasing adaptor is customizable for any desired geometry of the drift detector single cell with minimum drift time of carriers. The biasing adaptor has spiral shaped ion-implants that generate the desired voltage profile. The biasing adaptor can be processed on the same wafer as the drift detector array and only one biasing adaptor chip/side is needed for one drift detector array to generate the voltage profiles on the front side and back side of the detector array.

36 MATERIALS SCIENCE↗

High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 µm thick cadmium telluride (CdTe) sensor. The full imager is a 2 × 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 × 10 6 80 keV x-rays. Here, a charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.

99 GENERAL AND MISCELLANEOUS↗

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer’s compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Low-Power, Radiation-Resistant, Silicon-Drift-Detector Array for Extraterrestrial Element Mapping

We are developing a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) for measuring the abundances of light surface elements (C to Fe) fluoresced by ambient radiation on remote airless bodies. The value of fluorescence spectrometry for surface element mapping is demonstrated by its inclusion on three recent lunar missions and by exciting new data that have recently been announced from the Messenger Mission to Mercury. The SDD-XRS instrument that we have been developing offers excellent energy resolution and an order of magnitude lower power requirement than conventional CCDs, making much higher sensitivities possible with modest spacecraft resources. In addition, it is significantly more radiation resistant than x-ray CCDs and therefore will not be subject to the degradation that befell recent lunar instruments. In fact, the intrinsic radiation resistance of the SDD makes it applicable even to the harsh environment of the Jovian system where it can be used to map the light surface elements of Europa. In this paper, we first discuss our element-mapping science-measurement goals. We then derive the necessary instrument requirements to meet these goals and discuss our current instrument development status with respect to these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a 512-Channel Faraday-Strip Array Detector Coupled to an Inductively Coupled Plasma Mattauch-Herzog Mass Spectrograph

A 512-channel Faraday-strip array detector has been developed and fitted to a Mattauch-Herzog geometry mass spectrograph for the simultaneous acquisition of multiple mass-to-charge values. Several advantages are realized by using simultaneous detection methods, including higher duty cycles, removal of correlated noise, and multianalyte transient analyses independent of spectral skew. The new 512-channel version offers narrower, more closely spaced pixels, providing improved spectral peak sampling and resolution. In addition, the electronics in the amplification stage of the new detector array incorporate a sample-and-hold feature that enables truly simultaneous interrogation of all 512 channels. While sensitivity and linear dynamic range remain impressive for this Faraday-based detector system, limits of detection and isotope ratio data have suffered slightly from leaky p-n junctions produced during the manufacture of the semiconductor-based amplification and readout stages. This paper describes the new 512-channel detector array, the current dominant noise sources, and the figures of merit for the device as pertaining to inductively coupled plasma ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-AB-BRB-04: A Novel Monolithic Silicon 2D Detector Array for Use in Stereotactic Applications

Purpose: To assess the capability of a novel 2D monolithic silicon detector array in measuring stereotactic photon fields. Methods: The silicon array detector used in this work, named Magic Plate-512 (MP512), is a thin monolithic silicon wafer (52 × 52 × 0.47 mm{sup 3}) with 512 ion-implanted diodes (0.5 × 0.5 mm{sup 2}). Adjacent pixels are spaced evenly with 2 mm pitch, covering a maximum detection area 46 mm wide. Its fast, FPGA based read-out system is synchronised with the linac to allow readout of all pixels pulse-by-pulse. A clinical SABR lung plan (consisting of 9 single segment beams, 6MV) was measured with the array at 1.5 cm depth in a solid water phantom (100 cm SSD). The typical field size was in the range of 3 × 3 cm{sup 2} to 4 × 4 cm{sup 2}. Each beam was delivered at perpendicular incidence to the detector plane so as to avoid the need for angular dependence corrections. The fields were measured under the same conditions using Gafchromic EBT3 film for comparison. The film was scanned at 72 dpi resolution, with the red channel data used for analysis. Results: Average gamma passing rates of (92.3 ± 1.8) % for 2%/2mm criteria, and (86.6 ± 2.3) % for 1%/2mm criteria were achieved for MP512, using EBT3 film as the reference distribution. The detector array was able to accurately measure the full-width-at-half-maximum (FWHM), to within (0.77 ± 0.01) mm accuracy when compared to film. The penumbral widths (80%-20%) were measured to within (0.30 ± 0.01) mm accuracy to film. Conclusion: The MP512 is a feasible option for measurement of stereotactic photon fields, with its high density of detection points making it useful for small field applications. The prototype array has demonstrated merit; in the future the development of a larger array detection area would be beneficial for clinical applications.

60 APPLIED LIFE SCIENCES↗

Application of pixel array detectors at x-ray synchrotrons.

Pixel array detectors have only recently been seriously used at x-ray synchrotrons. We describe the application of a digital pixel array detector (Pilatus100k) to a variety of synchrotron experiments at the Advanced Photon Source at Argonne National Laboratory. The Pilatus100k was developed at the Paul Scherrer Institut (PSI). It has been commercialized by a PSI spinoff (Dectrics Ltd.) This is the first commercially available pixel array detector for x-ray synchrotron applications. The APS synchrotron provides tunable x-ray pulses with duration of {approx}80 ps and a repetition period of 153 ns (24-bunch mode). The Pilatus100k is a direct detection x-ray detector where each 172 micron pixel counts individual x-ray pulses above a lower threshold. It consists of {approx}100k pixels each of which is capable of single-photon counting (>3 keV) at count rates up to {approx}1 MHz. In addition, the Pilatus100k is an electronically gateable detector. We present data showing that the Pilatus100k is capable of isolating a single x-ray bunch at the APS in 24 bunch mode. We will also present a variety of different experiments exploiting the unique capabilities of the Pilatus100k.

43 PARTICLE ACCELERATORS↗