Development of a wide bandwidth heterodyne dispersion interferometer for electron density measurement of atmospheric pressure plasmas

One of the challenges of electron density measurements of an atmospheric pressure plasma (APP) with a laser interferometer is the significant and unwanted phase shift caused by changes in the neutral gas density. These unwanted phase shifts can be mitigated and plasma density measured using an interferometer architecture called a dispersion interferometer (DI). A DI is composed of two nonlinear orientation patterned GaAs crystals for frequency doubling and measures the phase shift induced by a plasma in the interference signal between two second-harmonic beams. Measurement of plasma dynamics or a short plasma pulse in less than a millisecond is enabled with heterodyne detection in a DI using an acousto-optic cell with a frequency of 40 MHz. This heterodyne DI (HDI) is targeted to measure APPs in an electron density range of 10 20 –10 24 m −3 . Finally, the HDI achieves a line-integrated density resolution of 2 × 10 15 m −2 (a phase resolution of 0.005°) with a time constant of 1 μs using ensemble averaging techniques.

atmospheric pressure plasma

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L

Magnetic Flux Density Measurements Inside the Z Environment Chamber During Warm X-Ray Shots

The peak magnetic flux density was measured as 148.7 T in the axial direction, at a distance of 41 inches from the source. This value is likely accurate as all field components fell within the 3 dB bandwidth of the accompanying balun, with the peak field component at 3.1 kHz. No field structure could be identified during the test series, suggesting the Z-pinch may create a “mode-stirred” EM environment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Electron density measurements and calculations in a helium capacitively-coupled radio-frequency plasma

We report a comparison of inferred electron density (n e ) in a He capacitively-coupled plasma, deduced from laser-collision induced fluorescence measurements, with values computed using a hybrid simulation framework based on particle-in-cell/Monte Carlo collisions simulations and a fluid model for excited He atoms. The studies were carried out for gas pressures between 50 mTorr and 1000 mTorr and peak-to-peak radio-frequency (13.56 MHz) voltages between 150 V and 350 V, in a highly symmetric source equipped with plane-parallel electrodes. A good agreement is found between the experimental and modeling results for n e except at the lowest operating voltages and gas pressures. The (effective) electron temperature (T e ) values derived by the two methods agree as well reasonably within the plasma bulk. The simulation results are used to compare the density distributions of He + and various He excited levels and their major populating and de-populating channels at 100 mTorr and 1000 mTorr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Measurement of the transverse energy density in Measurement of the transverse energy density in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV with the sPHENIX detector

Here, this paper reports measurements of the transverse energy per unit pseudorapidity (𝑑⁢𝐸 𝑇 /𝑑⁢𝜂) produced in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV, performed with the sPHENIX detector at the Relativistic Heavy Ion Collider (RHIC). The results cover the pseudorapidity range |𝜂| < 1.1 and constitute the first such measurement performed using a hadronic calorimeter at RHIC. Measurements of 𝑑⁢𝐸 𝑇 /𝑑⁢𝜂 are presented for a range of centrality intervals and the average 𝑑⁢𝐸 𝑇 /𝑑⁢𝜂 as a function of the number of participating nucleons, 𝑁 part , is compared to a variety of Monte Carlo heavy-ion event generators. The results are in agreement with previous measurements at RHIC, and feature an improved granularity in 𝜂 and improved precision in low-𝑁 part events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy

Inference of the neutron down-scatter ratio using neutron time-of-flight data for DT-layered implosions on the OMEGA laser

First analysis of the neutron time of flight (nTOF) data is presented to infer the areal density using the neutron down-scatter ratio (DSR) for OMEGA deuterium–tritium (DT)-layered (cryogenic) implosions. The required very-high-dynamic range (nTOF) signal is constructed using an nTOF detector [Forrest et al., Rev. Sci. Ins. 83, 10D919 (2012)] with multiple time-gated photomultiplier tubes. The nTOF data are analyzed using a forward-fit technique to account for the detector responses and infer the DSR and areal density for DT-layered implosions. The areal densities inferred using this analysis are found to be in agreement with the areal densities measured using the magnetic recoil spectrometer detector that is located in a similar line-of-sight. This work establishes the feasibility of the DSR measurement using nTOF data on OMEGA and provides an additional areal-density measurement that will benefit the assessment of the implosion performance and 3D reconstruction of the imploded core.

47 OTHER INSTRUMENTATION

High-field side scrape-off layer density profile measurements and implications for high-field side LHCD coupling in DIII-D

The high-field side (HFS) scrape-off layer (SOL) is an often under-diagnosed region of tokamak plasmas. Situated in a region with favorable curvature, the HFS SOL has minimal turbulence-induced radial transport compared to the low-field side. Using profile reflectometry, the HFS SOL density profile is measured with high temporal resolution for a wide range of DIII-D plasma discharges for the first time. The magnetic configuration, particularly the location of the secondary separatrix (SS) largely determines the HFS SOL density profile. Additionally, density perturbations induced by edge-localized modes (ELMs) are observed in the HFS SOL, and the impact of ELMs on the SOL density profile is characterized for a range of magnetic configurations. It is found that ELM-induced HFS SOL perturbations are generally localized to within the SS and ELM-induced changes to the HFS wall density are minimized in near double-null configurations. The characterization of the HFS SOL density profile on DIII-D is crucial for the effective coupling of the planned HFS lower hybrid current drive (LHCD) launcher. Experimental HFS SOL measurements are used as input to full-wave simulations of LHCD coupling. Furthermore, this work simulates the effect of the magnetic configuration on LHCD coupling. It also simulates LHCD coupling in ELMs and high q min discharges. During such discharges, the LHCD coupling is predicted to be resilient to ELM-induced SOL density perturbations.

high-field side

Comparison of laser-produced plasma spatio-temporal electron density evolution measured using interferometry with simulation results

Due to the difficulties associated with experimental measurements of laser-produced plasma (LPP) properties during the earliest stages of plasma evolution, radiation hydrodynamic codes are often used. However, although these codes have been extensively validated in the higher intensity regimes, validation at low to moderate intensities has been limited. In this study, the spatio-temporal electron density evolution in an LPP generated at moderate laser intensities and at various laser wavelengths was validated against the FLASH code for times up to 20 ns. The LPP was generated by focusing the fundamental and various harmonics radiation (1064, 532, and 266 nm) from a 6 ns full width half maximum Nd:YAG laser, at a laser intensity of 10 GW cm -2 , onto a copper target. The spatio-temporal density evolution of the expanding plasma was analyzed using Nomarski interferometry. Experimental measurements were found to be consistent with FLASH simulations, and the dependence of electron densities on wavelength was found to be in agreement with analytical models, varying as n e ∝ λ -0.7 . However, slight differences were noted in the widths and shape functions of the experimental and simulated electron density profiles.

2D fast imaging

Real-time Electron Temperature and Density Profile Measurements for NSTX-U

This project set out to design, build, and deploy a real-time multi-point Thomson scattering (rt MPTS) system for NSTX-U, capable of providing electron temperature and density profiles—and their uncertainties—in real time for use in equilibrium reconstruction and plasma control. The long-term goal was to move Thomson scattering from a purely post-shot diagnostic to a central element of real-time situation awareness and feedback control on NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Spatial profile of argon (1s 5 ) metastables in an electron beam generated plasma

Electron beams with an applied magnetic field generate a secondary cold plasma with a selective chemical composition, featuring low-energy ions and metastable species in the discharge periphery, ideal for low-damage plasma treatment of material substrates. In this work, we studied the plasma generated by an e-beam using a 4 kV voltage in a pure argon gas environment under a magnetic field of 150 G and in the pressure range of 25–90 mTorr. We measured the absolute spatial density profile of argon (1 s 5 ) metastables in an electron beam generated plasma by laser-induced fluorescence and found it to be of the order of 10 16 m −3 . The electron temperature and the electron density measured by a Langmuir probe were of the order of 10 16 m −3 and less than an eV respectively. Electron-impact quenching was identified as a significant loss mechanism for the Ar(1s 5 ) state, leading to the saturation of the metastable density at higher pressures. Outside the primary ionization region, the spatial distribution of argon metastables followed a linear diffusion profile, indicating negligible additional production in those regions.

EEDF

Analysis of the density field around a supersonic conical projectile using quantitative schlieren

Quantitative schlieren imaging is a flow measurement technique that is capable of measuring density fields throughout refractive flowfields. The technique was applied here to measure the density field surrounding supersonic conical projectiles in free flight. Shock waves attached to a supersonic conical projectile offer a simple geometry with the well-established Taylor–Maccoll analytical flow solution to which these experimental measurements were compared. The schlieren images recorded a projection of the index of refraction field surrounding the 10° half-angle cones which was converted to density first through an Abel inversion and then the Gladstone–Dale law. Three Abel inversion methods—two-point, three-point, and arbitrary ray axisymmetric projection (ARAP)—were applied to deconvolute the three-dimensional flow within the constrained axisymmetric flow field. The resulting reconstructed density profiles were compared to the Taylor–Maccoll solution, parameterized by cone geometry and Mach number. The experimental density fields demonstrated strong agreement with the theoretical profiles. Experimental consistency was confirmed across various projectile speeds, demonstrating quantitative schlieren’s capability to accurately reconstruct the density of the flow field, even within the resolution constraints imposed by high-speed imaging. In conclusion, an assessment of experimental uncertainties in the density reconstruction was performed.

Abel Inversion

One-dimensional mapping of femtosecond laser filaments using coherent microwave scattering

Here, this paper reports on the use of coherent microwave scattering (CMS) for spatially resolved electron number density measurements of elongated plasma structures induced at mid-IR femtosecond filamentation in air. The presented studies comprise one-dimensional mapping of laser filaments induced via 3.9 µm, 127.3 fs laser pulses at output energies up to 15 mJ. The axial electron number density was measured to be invariant (about 2 × 10 15 c⁢m −3 ) along the entire filament length and for all tested laser pulse energies 5–15 mJ, and the corresponding laser intensity in the middle portion of the filament was estimated to be nearly constant for 5–15 mJ pulse energies (about 30−40 TW/c⁢m 2 ). These findings support that intensity clamping conditions were achieved in the experiments. The proposed approach enables capabilities that are currently unavailable to perform absolute and longitudinally resolved measurements of electron number density in laser filaments and to precisely characterize conditions associated with self-focusing and intensity clamping.

plasma diagnostic techniques

Density of molten oxides measured in an aero-acoustic levitator

Knowing the thermophysical properties of high-temperature melts can aid the design of melt processes and validate atomic structural models, such as those used in studying glass formation. Property measurements on such melts are challenging, however, due to container-related contamination and heterogeneous nucleation. Containerless processing techniques that employ levitation can be used to avoid these obstacles. In that context, we demonstrate here the application of silhouette imaging to measure the density of molten oxides in an aero-acoustic levitation instrument (AAL). The AAL combines gas jet levitation with actively controlled acoustic positioning to enable full optical access to samples ca. 2–4 mm in diameter, which are laser beam heated and melted. The cross sections of molten drops are imaged using a monochromatic light source and narrowband-filtered camera. Melt volume is calculated from the cross sections and used to find density at several temperatures ranging 1530–1920 K, including up to 350 K of supercooling. We report densities for CaAl 2 O 4 , Ca 12 Al 14 O 33 , CaSiO 3 , their Fe 2 O 3 -bearing analogs, and 83TiO 2 -17RE 2 O 3 (RE = La or Nd). These provide important benchmarks of the capabilities, measurement uncertainties, and future outlook for this technique.

36 MATERIALS SCIENCE

DOE SCGSR Final Report - Project Accomplishments and Additional Materials

The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH