Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Denovo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Denovo--A New Three-Dimensional Parallel Discrete Ordinates Code in SCALE

Denovo is a new, three-dimensional, discrete ordinates (SN) transport code that uses state-of-the-art solution methods to obtain accurate solutions to the Boltzmann transport equation. Denovo uses the Koch-Baker-Alcouffe parallel sweep algorithm to obtain high parallel efficiency on O(100) processors on XYZ orthogonal meshes. As opposed to traditional SN codes that use source iteration, Denovo uses nonstationary Krylov methods to solve the within-group equations. Krylov methods are far more efficient than stationary schemes. Additionally, classic acceleration schemes (diffusion synthetic acceleration) do not suffer stability problems when used as a preconditioner to a Krylov solver. Denovo's generic programming framework allows multiple spatial discretization schemes and solution methodologies. Denovo currently provides diamond-difference, theta-weighted diamond-difference, linear-discontinuous finite element, trilinear-discontinuous finite element, and step characteristics spatial differencing schemes. Also, users have the option of running traditional source iteration instead of Krylov iteration. Multigroup upscatter problems can be solved using Gauss-Seidel iteration with transport, two-grid acceleration. A parallel first-collision source is also available. Denovo solutions to the Kobayashi benchmarks are in excellent agreement with published results. Parallel performance shows excellent weak scaling up to 20000 cores and good scaling up to 40000 cores.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

C5 Benchmark Problem with Discrete Ordinate Radiation Transport Code DENOVO

The C5 benchmark problem proposed by the Organisation for Economic Co-operation and Development/Nuclear Energy Agency was modeled to examine the capabilities of Denovo, a three-dimensional (3-D) parallel discrete ordinates (S{sub N}) radiation transport code, for problems with no spatial homogenization. Denovo uses state-of-the-art numerical methods to obtain accurate solutions to the Boltzmann transport equation. Problems were run in parallel on Jaguar, a high-performance supercomputer located at Oak Ridge National Laboratory. Both the two-dimensional (2-D) and 3-D configurations were analyzed, and the results were compared with the reference MCNP Monte Carlo calculations. For an additional comparison, SCALE/KENO-V.a Monte Carlo solutions were also included. In addition, a sensitivity analysis was performed for the optimal angular quadrature and mesh resolution for both the 2-D and 3-D infinite lattices of UO{sub 2} fuel pin cells. Denovo was verified with the C5 problem. The effective multiplication factors, pin powers, and assembly powers were found to be in good agreement with the reference MCNP and SCALE/KENO-V.a Monte Carlo calculations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Full Core Reactor Analysis: Running Denovo on Jaguar

Fully-consistent, full-core, 3D, deterministic neutron transport simulations using the orthogonal mesh code Denovo were run on the massively parallel computing architecture Jaguar XT5. Using energy and spatial parallelization schemes, Denovo was able to efficiently scale to more than 160k processors. Cell-homogenized cross sections were used with step-characteristics, linear-discontinuous finite element, and trilinear-discontinuous finite element spatial methods. It was determined that using the finite element methods gave considerably more accurate eigenvalue solutions for large-aspect ratio meshes than using step-characteristics.

Denovo↗

Full Core Reactor Analysis: Running Denovo on Jaguar

Fully-consistent, full-core, 3D, deterministic simulations using the orthogonal mesh code Denovo were run on the massively parallel computing architecture Jaguar XT5. Using energy and spatial parallelization schemes, Denovo was able to efficiently scale to over 160k processors. Cell-homogenized cross-sections were used with Step-Characteristics, Linear-Discontinuous Finite Element, and Tri-Linear-Discontinuous Finite Element spatial methods. It was determined that using the finite element methods gave considerably more accurate eigenvalue solutions for large aspect ratios meshes than those using Step-Characteristics.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of the Denovo Discrete Ordinates Radiation Transport Code to Large-Scale Fusion Neutronics

Fusion energy systems pose unique challenges to the modeling and simulation community. These challenges must be met to ensure the success of the ITER experimental fusion reactor. ITER’s complex systems require detailed modeling that goes beyond the scale of comparable simulations to date. In this work, the Denovo radiation transport code was used to calculate neutron fluence and kerma for the JET streaming benchmark. This work was performed on the Titan supercomputer at the Oak Ridge Leadership Computing Facility. Denovo is a novel three-dimensional discrete ordinates transport code designed to be highly scalable. Sensitivity studies have been completed to examine the impact of several deterministic parameters. Furthermore, results were compared against experiment as well as the MCNP and Shift Monte Carlo codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Full core reactor analysis: Running Denovo on Jaguar

Fully-consistent, full-core, 3D, deterministic neutron transport simulations using the orthogonal mesh code Denovo were run on the massively parallel computing architecture Jaguar XT5. Using energy and spatial parallelization schemes, Denovo was able to efficiently scale to more than 160 k processors. Cell-homogenized cross sections were used with step-characteristics, linear-discontinuous finite element, and trilinear-discontinuous finite element spatial methods. It was determined that using the finite element methods gave considerably more accurate eigenvalue solutions for large-aspect ratio meshes than using step-characteristics. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Note RNSD-00-000: Evaluating the Denovo SPN Discretization (Rev. 1)

This document describes a preliminary assessment of the SP N discretization in Denovo. Comparison to existing S N discretizations is provided for three variants of CASL AMA Problem 2. Evaluation of the accuracy for both pin-resolved and pin-homogenized cross section processing options are studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High performance radiation transport simulations: Preparing for TITAN

In this paper we describe the Denovo code system. Denovo solves the six-dimensional, steady-state, linear Boltzmann transport equation, of central importance to nuclear technology applications such as reactor core analysis (neutronics), radiation shielding, nuclear forensics and radiation detection. The code features multiple spatial differencing schemes, state-of-the-art linear solvers, the Koch-Baker-Alcouffe (KBA) parallel-wavefront sweep algorithm for inverting the transport operator, a new multilevel energy decomposition method scaling to hundreds of thousands of processing cores, and a modern, novel code architecture that supports straightforward integration of new features. In this paper we discuss the performance of Denovo on the 20+ petaflop ORNL GPU-based system, Titan. We describe algorithms and techniques used to exploit the capabilities of Titan's heterogeneous compute node architecture and the challenges of obtaining good parallel performance for this sparse hyperbolic PDE solver containing inherently sequential computations. Numerical results demonstrating Denovo performance on early Titan hardware are presented.

Baker, C.↗

Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method

Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold-standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x-ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root-mean-square difference of around 2.4%. It was found that the discrete ordinates method, with a higher order of Legendre polynomial expansions, underestimated the absorbed dose near the center of the phantom (i.e., low dose region). Simulations of the quadrature set 8 and the first order of the Legendre polynomial expansions proved to be the most efficient computation method in the authors’ study. The single-thread computation time of the deterministic simulation of the quadrature set 8 and the first order of the Legendre polynomial expansions was 21 min on a personal computer. Conclusions: The simulation results showed that the deterministic method can be effectively used to estimate the absorbed dose in a CTDI phantom. The accuracy of the discrete ordinates method was close to that of a Monte Carlo simulation, and the primary benefit of the discrete ordinates method lies in its rapid computation speed. It is expected that further optimization of this method in routine clinical CT dose estimation will improve its accuracy and speed.

07 ISOTOPE AND RADIATION SOURCES↗

Sensitivities and Uncertainties Related to Numerics and Building Features in Urban Modeling

Oak Ridge National Laboratory (ORNL) has been engaged in the development and testing of a computational system that would use a grid of activation foil detectors to provide postdetonation forensic information from a nuclear device detonation. ORNL has developed a high-performance, three-dimensional (3-D) deterministic radiation transport code called Denovo. Denovo solves the multigroup discrete ordinates (SN) equations and can output 3-D data in a platform-independent format that can be efficiently analyzed using parallel, high-performance visualization tools. To evaluate the sensitivities and uncertainties associated with the deterministic computational method numerics, a numerical study on the New York City Times Square model was conducted using Denovo. In particular, the sensitivities and uncertainties associated with various components of the calculational method were systematically investigated, including (a) the Legendre polynomial expansion order of the scattering cross sections, (b) the angular quadrature, (c) multigroup energy binning, (d) spatial mesh sizes, (e) the material compositions of the building models, (f) the composition of the foundations upon which the buildings rest (e.g., ground, concrete, or asphalt), and (g) the amount of detail included in the building models. Although Denovo may calculate the idealized model well, there may be uncertainty in the results because of slight departures of the above-named parameters from those used in the idealized calculations. Fluxes and activities at selected locations from perturbed calculations are compared with corresponding values from the idealized or base case to determine the sensitivities associated with specified parameter changes. Results indicate that uncertainties related to numerics can be controlled by using higher fidelity models, but more work is needed to control the uncertainties related to the model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for Detector Placement and Analysis of Criticality Accident Alarm Systems

Determining the optimum placement to minimize the number of detectors for a criticality accident alarm system (CAAS) in a large manufacturing facility is a complex problem. There is typically a target for the number of detectors that can be used over a given zone of the facility. A study to optimize detector placement typically begins with some initial guess at the placement of the detectors and is followed by either predictive calculations of accidents at specific locations or adjoint calculations based on preferred detector locations. Within an area of a facility, there may be a large number of potential criticality accident sites. For any given placement of the detectors, the list of accident sites can be reduced to a smaller number of locations at which accidents may be difficult for detectors to detect. Developing the initial detector placement and determining the list of difficult accident locations are both based on the practitioner's experience. Simulations following fission particles released from an accident location are called 'forward calculations.' These calculations can be used to answer the question 'where would an alarm be triggered?' by an accident at a specified location. Conversely, 'adjoint calculations' start at a detector site using the detector response function as a source and essentially run in reverse. These calculations can be used to answer the question 'where would an accident be detected?' by a specified detector location. If the number of accidents, P, is much less than the number of detectors, Q, then forward simulations may be more convenient and less time-consuming. If Q is large or the detectors are not placed yet, then a mesh tally of dose observed by a detector at any location must be computed over the entire zone. If Q is much less than P, then adjoint calculations may be more efficient. Adjoint calculations employing a mesh tally can be even more advantageous because they do not rely on a list of specific difficult-to-detect accident sites, which may not have included every possible accident location. Analog calculations (no biasing) simply follow particles naturally. For sparse buildings and line-of-sight calculations, analog Monte Carlo (MC) may be adequate. For buildings with internal walls or large amounts of heavy equipment (dense geometry), variance reduction may be required. Calculations employing the CADIS method use a deterministic calculation to create an importance map and a matching biased source distribution that optimize the final MC to quickly calculate one specific tally. Calculations employing the FW-CADIS method use two deterministic calculations (one forward and one adjoint) to create an importance map and a matching biased source distribution that are designed to make the MC calculate a mesh tally with more uniform uncertainties in both high-dose and low-dose areas. Depending on the geometry of the problem, the number of detectors, and the number of accident sites, different approaches to CAAS placement studies can be taken. These are summarized in Table I. SCALE 6.1 contains the MAVRIC sequence, which can be used to perform any of the forward-based approaches outlined in Table I. For analog calculations, MAVRIC simply calls the Monaco MC code. For CADIS and FW-CADIS, MAVRIC uses the Denovo discrete ordinates (SN) deterministic code to generate the importance map and biased source used by Monaco. An adjoint capability is currently being added to Monaco and should be available in the next release of SCALE. An adjoint-based approach could be performed with Denovo alone - although fine meshes, large amounts of memory, and long computation times may be required to obtain accurate solutions. Coarse-mesh SN simulations could be employed for adjoint-based scoping studies until the adjoint capability in Monaco is complete. CAAS placement studies, especially those dealing with mesh tallies, require some extra utilities to aid in the analysis. Detectors must receive a minimum dose rate in order to alarm; therefore, a simple yes/no plot could be more useful to the analyst than a standard dose rate contour plot. Alarm systems that require several detectors to alarm simultaneously for a given accident would need to combine several yes/no plots in order to show accident sites where multiple detectors would be triggered. This could require a plot of 'areas of coverage' that is mapped over the building geometry. Several new utilities (which will be part of SCALE 6.2) were created to help with CAAS analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deterministically estimated fission source distributions for Monte Carlo k-eigenvalue problems

The standard Monte Carlo (MC) k-eigenvalue algorithm involves iteratively converging the fission source distribution using a series of potentially time-consuming inactive cycles before quantities of interest can be tallied. One strategy for reducing the computational time requirements of these inactive cycles is the Sourcerer method, in which a deterministic eigenvalue calculation is performed to obtain an improved initial guess for the fission source distribution. This method has been implemented in the Exnihilo software suite within SCALE using the SPNSPN or SNSN solvers in Denovo and the Shift MC code. The efficacy of this method is assessed with different Denovo solution parameters for a series of typical k-eigenvalue problems including small criticality benchmarks, full-core reactors, and a fuel cask. Here it is found that, in most cases, when a large number of histories per cycle are required to obtain a detailed flux distribution, the Sourcerer method can be used to reduce the computational time requirements of the inactive cycles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shutdown dose rate analysis with the Shift Monte Carlo radiation transport code and modular verification workflow

Calculation of the shutdown dose rate is crucial for safe fusion reactor operations. The Rigorous-two-step (R2S) method is a method that requires connected neutron transport, activation, and gamma transport. Shift has integrated variance reduction with a deterministic solver Denovo, supports multiple geometry formats, and is scalable. These features make it an attractive transport solver choice for an R2S workflow. An R2S workflow for the Shift Monte Carlo code is developed and compared to the existing Oak Ridge National Laboratory Shutdown Dose Rate Code Suite (ORCS) workflow. Also, a Python framework for integrating two R2S workflows is developed to mix and match each step in the R2S workflow for improved collaboration and verification experience. In this study, results show that the Shift-Denovo R2S workflow and the ORCS workflow calculate the shutdown dose rate of the ITER Shutdown Dose Rate benchmark problem with an average relative error of 2.285%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multigrid in energy preconditioner for Krylov solvers

We have added a new multigrid in energy (MGE) preconditioner to the Denovo discrete-ordinates radiation transport code. This preconditioner takes advantage of a new multilevel parallel decomposition. A multigroup Krylov subspace iterative solver that is decomposed in energy as well as space-angle forms the backbone of the transport solves in Denovo. The space-angle-energy decomposition facilitates scaling to hundreds of thousands of cores. The multigrid in energy preconditioner scales well in the energy dimension and significantly reduces the number of Krylov iterations required for convergence. This preconditioner is well-suited for use with advanced eigenvalue solvers such as Rayleigh Quotient Iteration and Arnoldi.

97 MATHEMATICS AND COMPUTING↗

Dose Rate Evaluation for the ES-3100 Package with HEU Content Using MCNP, ADVANTG, Monaco, and MAVRIC

Here, this paper presents a comparative study of dose rate calculations for the ES-3100 package with highly enriched uranium (HEU) content for different source configurations using computer codes: (1) MCNP; (2) Automated Variance Reduction Generator (ADVANTG)/MCNP; (3) Monaco; and (4) Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC). The Model ES-3100 package was developed at the Y-12 National Security Complex for domestic and international transportation of Type B fissile radioactive material. In this study, six different source configurations (i.e., solid cylinder, cylindrical hemi-shell, cylindrical shell, rectangular plate, cylindrical rod, or cylindrical segment form) having 36 kg of HEU metal inside the package containment vessel (based on configurations in the ES-3100/HEU safety analysis report for packaging) are evaluated. Dose rates at the package surfaces and 1 m from the package surfaces are calculated for these different source configurations. MCNP and Monaco cases are run without any biasing options to accelerate the convergence. Consistent Adjoint Driven Importance Sampling (CADIS) and Forward-Weighted CADIS (FW-CADIS) methods developed at the Oak Ridge National Laboratory are implemented in ADVANTG/MCNP and MAVRIC codes to accelerate the convergence. ADVANTG generates variance reduction parameters using Denovo code, and MCNP is used with the variance reduction parameters to accelerate the convergence. MAVRIC uses Denovo code to construct an importance map and a biased source distribution that are supplied to Monaco to accelerate the Monte Carlo simulation. The FW-CADIS option in ADVANTG and MAVRIC is used to accelerate the convergence in this study. The accelerated convergence cases (ADVANTG/MCNP and MAVRIC) are about 100 times faster with 100 times less particle simulation than those cases run without biasing options (analog MCNP and analog Monaco). Lastly, the MCNP, ADVANTG/MCNP, Monaco, and MAVRIC calculated dose rates at the package surfaces and at 1 m from the package surfaces for the different source configurations are compared and are found to be in general agreement.

42 ENGINEERING↗