Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Demagnetization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Demagnetization analysis of an 18 GHz electron cyclotron resonance ion source permanent magnet hexapole

An upgrade of ECR2 at the Argonne Tandem Linac Accelerator System is under way, focusing on increasing the intensity capabilities of the facility. ECR2 is a room temperature electron cyclotron resonance ion source, and the upgrade has strict requirements to retain radial access to the plasma chamber and keep the ion source operating without the use of superconducting magnets. The upgrade design with respect to the magnet arrangement and magnetization vectors has recently been presented [R. C. Vondrasek, J. McLain, and R. H. Scott, J. Phys.: Conf. Ser. 2743 , 012044 (2024)] using the same magnetic material as the current ECR2 hexapole. A thorough exploration of the demagnetization potential of this hexapole was carried out, and the risk of demagnetization was deemed too high, despite the magnetic performance meeting the requirements for the upgrade. Additional permanent magnet materials are considered with their respective performance evaluated. Magnet strength and demagnetization resistance are investigated and optimized with the final room temperature design demonstrating a high temperature transient demagnetization resistance and a radial magnetic field of 1.18 T at the plasma chamber wall. Finally, the simulations of this hexapole suggest that it will be sufficient to optimize intensity with a 14.5 GHz driving frequency and will allow 18 GHz operation, while keeping a high safety margin for maintaining magnet performance.

Argonne Tandem Linac Accelerator System

Ultrafast local demagnetization in 𝑑 6 systems via driven Jahn-Teller distortions

Ultrafast control of spin orientations without relying on highly nonequilibrium electron distributions offers a new pathway for femtosecond spintronics. It is shown that excitation of specific vibronic modes can drive a substantial demagnetization of a local moment relative to the magnetization axis, while preserving its total spin quantum number. Using a fully quantum many-body treatment of a local 𝑆=2 (𝑑 6 ) many-body spin coupled to a driven Jahn-Teller mode with quantum dissipation, we find that the projected spin can be strongly reduced via a Jahn-Teller-induced 𝑥⁢𝑦↑→𝑦⁢𝑧/𝑧⁢𝑥↓ transition, which occurs without additional Coulomb exchange cost. The excited state subsequently relaxes back to its original electronic configuration with a rotated spin direction, enabling spin reorientation without generating a large net angular momentum in the electronic subsystem.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Correlation of coercivity, microstructure, and surface defects in HDDR-processed Nd-Fe-B powders for bonded magnet applications

Hydrogenation-Disproportionation-Desorption-Recombination (HDDR) is an effective method for producing high coercivity, anisotropic powder from either fresh Nd-Fe-B alloy or recycled Nd-Fe-B magnets for use in bonded magnets. We investigated the impact of surface defects on the coercivity of HDDR-processed Nd-Fe-B using scanning electron microscopy (SEM), magnetic measurements, and micromagnetic simulations. We observed that coercivity decreases as particle size reduces, with SEM revealing surface defects and the detachment of Nd 2 Fe 14 B grains and Nd-rich phases from the particle surface. Micromagnetic simulations indicate that demagnetization initiates at the particle surface, where these defects are most concentrated, leading to reduced coercivity. The reduction in squareness of demagnetization curve, knee point field and coercivity for smaller HDDR particles is attributed to an increased specific surface area, which exhibits reduced nucleation field and weak domain wall pinning field during magnetization reversal. By addressing the role of surface defects in coercivity degradation, this study provides insights for improving both new powder production and recycling strategies, ultimately leading to enhanced performance of bonded magnets and contributing to more sustainable practices in the rare earth supply chain. One potential strategy to enhance the performance of HDDR Nd-Fe-B materials involves reducing the fraction of fine particles ($<$35 µm) and promoting the formation of grain boundary phases on particle surfaces.

Liu, Xubo B. [Ames Laboratory (AMES), Ames, IA (Un

Ultrafast Terahertz Field Control of the Emergent Magnetic and Electronic Interactions at Oxide Interfaces

Ultrafast electric-field control of emergent electronic and magnetic states at oxide interfaces offers exciting prospects for the development of the next generation of energy-efficient devices. Here, it is demonstrated that the electronic structure and emergent ferromagnetic interfacial state in epitaxial LaNiO3/CaMnO3 superlattices can be effectively controlled using intense, single-cycle THz electric-field pulses. A suite of advanced X-ray spectroscopic techniques is employed to measure a detailed magneto-optical profile and the thickness of the ferromagnetic interfacial layer. Then, a combination of time-resolved and temperature-dependent optical measurements is used to disentangle several correlated electronic and magnetic processes driven by ultrafast, high-field THz pulses. Sub-picosecond non-equilibrium Joule heating of the electronic system is observed, ultrafast demagnetization of the ferromagnetic interfacial layer, and slower dynamics indicative of a change in the magnetic state of the superlattice due to the transfer of spin-angular momentum to the lattice. These findings suggest a promising avenue for the efficient control of 2D ferromagnetic states at oxide interfaces using ultrafast electric-field pulses.

X-ray spectroscopy and scattering

Design and optimization of processes for recovering rare earth elements from end‐of‐life permanent magnets

Recovery of rare earth elements (REEs) from end-of-life (EOL) products represents a strategic opportunity to strengthen the domestic supply chain for rare earth elements. This work presents a superstructure-based optimization framework for finding the most economical processing pathway for different EOL rare earth permanent magnets (REPMs). The framework evaluates state-of-the-art technologies across four processing stages—disassembly, demagnetization, leaching and extraction, and precipitation and calcination—using net present value (NPV) maximization and cost of recovery (COR) minimization objectives. A novel bottom-up costing framework for hydrogen decrepitation is also introduced. Two feedstocks were considered: REPMs from EOL hard disk drives (HDDs), and electric and hybrid electric vehicles (EVs and HEVs). While HDD recycling proved unprofitable due to limited feedstock availability, EVs/HEVs were profitable across a range of parameters and cost estimates. Therefore, our findings suggest that the proposed EOL EV/HEV recycling process may be economical and is worthy of further investigation.

29 ENERGY PLANNING, POLICY, AND ECONOMY

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial

Effect of magneto-mechanical synergism in the process-structure correlation in Fe–C alloys: A phase-field modeling approach

Applied magnetic fields can alter phase equilibria and kinetics in steels; however, quantitatively resolving how magnetic, chemical, and elastic driving forces jointly influence the microstructure remains challenging. We develop a quantitative magneto-mechanically coupled phase-field model for the Fe–C system that couples a CALPHAD-based chemical free energy with demagnetization-field magnetostatics and microelasticity. Here, the model reproduces single- and multi-particle evolution during the α → γ inverse transformation at 1023 K under external fields up to 20 T, including ellipsoidal morphologies observed experimentally at 8 T. Chemically driven growth is isotropic; a magnetic interaction introduces an anisotropic driving force that elongates γ precipitates along the field into ellipsoids, while elastic coherency promotes faceting, yielding elongated cuboidal or “brick-like” particles under combined magneto-elastic coupling. Growth kinetics increase with C content, and decrease with field strength and misfit strain. Multi-particle simulations reveal dipolar interaction-mediated coalescence for field-parallel neighbors and ripening for field-perpendicular neighbors. Incorporating field-dependent diffusivity from experiment slows kinetics as expected; a first-principles-motivated anisotropic diffusivity correction is estimated to be small (<2%). These results establish a process-structure link for magnetically assisted heat treatments of Fe–C alloys and provide guidance for microstructure control via chemo-magneto-mechanical synergism.

Magnetic field

Curvilinear Magnonic Crystal Based on 3D Hierarchical Nanotemplates

Curvilinear magnetic nanostructures enable control of magnetization dynamics through geometry-induced anisotropy and chiral interactions, as well as magnetic field modulation. In this work, we report a curvilinear magnonic crystal based on large-area square arrays of truncated nanospikes fabricated by conformal coating of 3D hierarchical templates with permalloy thin films. Brillouin light scattering spectroscopy reveals an anisotropic band structure with multiple dispersive and folded Bloch-type dispersive spin-wave modes as well as nondispersive modes exhibiting direction-dependent frequency shifts and intensity asymmetries along lattice principal axes. Finite element micromagnetic simulations indicate that curvature-induced variations of the demagnetizing field govern the magnonic response, enabling the identification of modes propagating in nanochannels and others localized on nanospike apexes or along the ridges connecting adjacent nanospikes. The combination of geometric curvature and optical probing asymmetry produces directional dependence of magnonic bands, establishing 3D hierarchical templates as a versatile platform for curvature-engineered magnonics.

3D hierarchical templates

Inhomogeneous Magnetic Anisotropy in an Fe 5– x GeTe 2 Nanoflake Observed by Imaging

Few-layer flakes of ferromagnetic Fe 5–x GeTe 2 with x = 0.3 (F5GT) possess a c-axis magnetocrystalline anisotropy that is large enough below ∼200 K to outcompete the easy-plane shape anisotropy, yielding distinctive magnetic microstructures with out-of-plane (OOP) magnetizations. Using photoemission electron microscopy (PEEM) with magnetic contrast from X-ray magnetic circular dichroism (XMCD) to study a thermally demagnetized h-BN-protected nanoflake of F5GT at 110 K, we observe a micron-scale coexistence between domains with OOP magnetizations (∼70% areal fraction) and hitherto unknown domains in which in-plane (IP) magnetization components dominate (∼30% areal fraction). The regions with dominant IP magnetization components do not correlate with small variations of flake thickness (6–10 nm) and instead arise from local changes of magnetocrystalline anisotropy due to a hitherto unidentified chemical inhomogeneity that we suggest to be a higher concentration of Fe vacancies. Our observation of micron-scale inhomogeneity would likely be missed if imaging a single flake orientation and should affect the viability and performance of van der Waals (vdW) spintronic devices with F5GT electrodes.

2D materials

Optical neural engine for solving scientific partial differential equations

Abstract Solving partial differential equations (PDEs) is the cornerstone of scientific research and development. Data-driven machine learning (ML) approaches are emerging to accelerate time-consuming and computation-intensive numerical simulations of PDEs. Although optical systems offer high-throughput and energy-efficient ML hardware, their demonstration for solving PDEs is limited. Here, we present an optical neural engine (ONE) architecture combining diffractive optical neural networks for Fourier space processing and optical crossbar structures for real space processing to solve time-dependent and time-independent PDEs in diverse disciplines, including Darcy flow equation, the magnetostatic Poisson’s equation in demagnetization, the Navier-Stokes equation in incompressible fluid, Maxwell’s equations in nanophotonic metasurfaces, and coupled PDEs in a multiphysics system. We numerically and experimentally demonstrate the capability of the ONE architecture, which not only leverages the advantages of high-performance dual-space processing for outperforming traditional PDE solvers and being comparable with state-of-the-art ML models but also can be implemented using optical computing hardware with unique features of low-energy and highly parallel constant-time processing irrespective of model scales and real-time reconfigurability for tackling multiple tasks with the same architecture. The demonstrated architecture offers a versatile and powerful platform for large-scale scientific and engineering computations.

Tang, Yingheng (ORCID:0009000153622546)

Enhanced coercivity in Fe5C2/SiO2 core/shell nanocrystals

Rod-shaped Fe5C2 and core/shell Fe5C2/SiO2 nanocrystals were synthesized via a solution-based chemical method. Structural analysis confirmed the monoclinic phase of Fe5C2 with space group C2/c. Zero-field-cooling (ZFC) and field-cooling (FC) magnetization curves revealed distinct magnetic behaviors: uncoated Fe5C2 exhibited a low-temperature FC plateau indicative of strong dipolar interactions, while Fe5C2/SiO2 showed a monotonic increase in FC magnetization, suggesting reduced dipolar interactions due to SiO2 surface passivation. Isothermal remanent magnetization (IRM) and DC demagnetization (DCD) measurements supported this trend, with δM plots confirming weaker dipolar interactions in the coated sample. Bloch’s law fitting of temperature-dependent saturation magnetization showed a smaller Bloch’s constant for pure Fe5C2 and a larger value for Fe5C2/SiO2, reflecting enhanced surface disorder and reduced exchange coupling in the latter. Notably, Fe5C2/SiO2 demonstrated increased coercivity, attributed to decreased dipolar interaction and elevated surface anisotropy. Kneller’s law fitting yielded higher blocking temperatures for Fe5C2 (476 K) than Fe5C2/SiO2 (456 K), highlighting the impact of dipolar interactions on magnetic relaxation. These findings illustrate how SiO2 coatings effectively modulate dipolar interactions and enhance coercivity in Fe5C2 nanocrystals.

Joshi, Pramanand [Department of Physics, Universit

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission

Status Update of Permanent Magnet Radiation Resiliency Studies at CEBAF

The proposed energy upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) incorporates Fixed-Field Alternating-gradient (FFA) arcs utilizing permanent magnet technology. Given the radiation environment within the CEBAF tunnel enclosure, validating the long-term magnetic stability of these materials is a critical step for the project's technical feasibility. This contribution presents an overview of the ongoing permanent magnet radiation resiliency program at Jefferson Lab. We briefly review the experimental methodology used to monitor demagnetization in situ and summarize the operational experience from the initial data-taking campaign. Furthermore, we discuss the upgrades implemented for the second exposure campaign, currently underway, which aims to refine dose correlation and reduce systematic uncertainties. We report on the general status of the program and the roadmap for certifying permanent magnet optics for the proposed upgrade energies.

Bodenstein, R. [Thomas Jefferson National Accelera

Magnetic Avalanche Detector using Single-Molecule Magnets

Here we discuss the results of the 9 month add-on project: “Magnetic Avalanche Detector using Single-Molecule Magnets”. The key point of the projects was to design a cryogenic system that is capable of applying magnetic fields high enough to magnetize the Single-Molecule Magnets (SMMs), maintain temperatures below 1K, and be able to detect magnetic avalanches of the SMM domains. We were able to achieve these goals. Our system was able to magnetize and sense the magnetization of SMM crystals. Moreover, we were able to detect avalanche demagnetization events caused by an alpha particle interacting with a magnetized SMM.

47 OTHER INSTRUMENTATION

Cryogenic Performance of the SPT-SLIM Receiver

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wave line-intensity mapping experiment, deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral Summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We present on the cryogenic performance of the SPT-SLIM receiver for this Year 1 observing campaign. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Referigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150mK. We demonstrate stable thermal performance of the focal plane module during observing operations in line with thermal modelling, enabling a cryogenic operation efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, Matthew [Fermilab]

AL-CRADA-2025-01 Final Report: American-Made Wind Turbine Materials Recycling Prize Accelerate! Phase 2

This report summarizes the Phase 2 achievements of the Wind Turbine Materials Recycling Prize project led by Critical Materials Recycling (CMR) in partnership with Ames National Laboratory. The team demonstrated the technical feasibility and economic viability of recovering and reusing rare-earth Nd-Fe-B magnets from end-of-life (EOL) wind turbine generators. Through mechanical disassembly, demagnetization, and precision processing, magnets were harvested and characterized to assess structural, compositional, and magnetic properties. Results showed that recovered magnets performed on par with commercial-grade counterparts, enabling their integration into actuator and motor prototypes without redesign. System-level modeling and finite-element simulations validated operational performance, while Life Cycle Cost (LCC) analysis revealed up to 20% material cost savings and 2–3% reductions in overall motor system costs. Life Cycle Assessment (LCA) further confirmed substantial environmental benefits, including a ~94% reduction in global warming potential relative to virgin magnet production. The project’s success was enabled by a tightly integrated partnership between industry and national lab experts, illustrating a viable path for domestic magnet-to-magnet recycling. These findings support a scalable, circular solution for rare-earth material recovery, reducing dependence on imported critical minerals and advancing sustainable clean energy technologies.

Lograsso, Thomas [Ames Laboratory (AMES), Ames, IA

Design and Performance of the SPT-SLIM Receiver Cryostat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic operating efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, M. R. [Fermilab; Chicago U., KICP]