Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Decay Curve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Decay Curve Correction Analysis Report

The decay curve analysis that is done on the short-lived radionuclide gas samples is used to differentiate between gaseous radionuclides that have the same characteristic gamma decay energy, 511 kiloelectron-volts (keV). A sample of stack gas is isolated and the total counts in the 511 keV peak are counted repeatedly in 10-second intervals to evaluate the decay rate of the sample over time. Analysis of this decay data required a series of steps. First, a raw data report is generated by the gamma acquisition system, based on an analysis template within the acquisition software. The data report file was then loaded into Microsoft Word, and a macro was used to perform minor formatting (remove colons and insert tabs between data columns) to allow analysis within Excel. The file is then saved as a text file at this point. The text file is then uploaded into Excel and a series of macros are used to add labels, calculate radioactive decay constants, and analyze the gamma decay data using linear regression techniques. The analysis template has been used since 1998 for stack 53000303 (TA-53, building 0003, exhaust stack 03) and 2000 for stack 53000702. The overall process, including the gamma report format and the macros used in Word and Excel for processing the report, had remained unchanged until 2015. In October of 2015, staff made a change to the report template in the gamma acquisition software which resulted in an error in the calculations later performed by the Excel macro. This error was not caught until a more in-depth review of the analysis took place regarding 2020 data. This report covers a much more complete review of the issue that occurred regarding the decay curve analysis, a review of the calculations completed to correct the issue, a review of the updated decay curve analysis process, and recommendations for moving forward.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decay curve analysis for data error quantification in time-domain induced polarization imaging

In recent years, the time-domain induced polarization (TDIP) imaging technique has emerged as a suitable method for the characterization and the monitoring of hydrogeologic and biogeochemical processes. However, one of the major challenges refers to the resolution of the electrical images. Hence, various studies have stressed the importance of data processing, error characterization, and the deployment of adequate inversion schemes. A widely accepted method to assess data error in electrical imaging relies on the analysis of the discrepancy between normal and reciprocal measurements. Nevertheless, the collection of reciprocals doubles the acquisition time and is only viable for a limited subset of commonly used electrode configurations (e.g., dipole-dipole [DD]). To overcome these limitations, we have developed a new methodology to quantify the data error in TDIP imaging, which is entirely based on the analysis of the recorded IP decay curve and does not require recollection of data (e.g., reciprocals). The first two steps of the methodology assess the general characteristics of the decay curves and the spatial consistency of the measurements for the detection and removal of outliers. In the third and fourth steps, we quantify the deviation of the measured decay curves from a smooth model for the estimation of random error of the total chargeability and transfer resistance measurement. The error models and imaging results obtained from this methodology - in the following referred to as "decay curve analysis" - are compared with those obtained following a conventional normal-reciprocal analysis revealing consistent results. As a result, we determine the applicability of our methodology with real field data collected at the floodplain scale (approximately 12 ha) using multiple gradient and DD configurations.

58 GEOSCIENCES↗

Decay curve study in a standard electron capture decay

We have searched for a time-modulated decay in a standard electron capture experiment for {sup 140}Pr, in order to confirm a report from GSI, where an oscillatory decay has been observed for hydrogen-like {sup 140}Pr and {sup 142}Pm ions in the cooler storage ring. {sup 140}Pr has been produced with the {sup 140}Ce(p, n) reaction by a pulsed proton beam accelerated from the Van de Graaff accelerator at Osaka University. Resultant time dependence of the K{sub a}lpha and K{sub b}eta X-ray intensities from the daughter shows no oscillatory behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of GRB light-curve decay indices in the afterglow phase

In this work, we study the distribution of temporal power-law decay indices, α, in the gamma-ray burst (GRB) afterglow phase, fitted for 176 GRBs (139 long GRBs, 12 short GRBs with extended emission, and 25 X-ray flashes) with known redshifts. These indices are compared with the temporal decay index, α {sub W}, derived with the light-curve fitting using the Willingale et al. model. This model fitting yields similar distributions of α {sub W} to the fitted α, but for individual bursts a difference can be significant. Analysis of (α, L {sub a}) distribution, where L {sub a} is the characteristic luminosity at the end of the plateau, reveals only a weak correlation of these quantities. However, we discovered a significant regular trend when studying GRB α values along the Dainotti et al. correlation between L {sub a} and the end time of the plateau emission in the rest frame, T{sub a}{sup ∗}, hereafter LT correlation. We note a systematic variation of the α parameter distribution with luminosity for any selected T{sub a}{sup ∗}. We analyze this systematics with respect to the fitted LT correlation line, expecting that the presented trend may allow us to constrain the GRB physical models. We also attempted to use the derived correlation of α(T{sub a}) versus L{sub a}(T{sub a}) to diminish the luminosity scatter related to the variations of α along the LT distribution, a step forward in the effort of standardizing GRBs. A proposed toy model accounting for this systematics applied to the analyzed GRB distribution results in a slight increase of the LT correlation coefficient.

79 ASTRONOMY AND ASTROPHYSICS↗

Treatment with integrase inhibitor suggests a new interpretation of HIV RNA decay curves that reveals a subset of cells with slow integration

The kinetics of HIV-1 decay under treatment depends on the class of antiretrovirals used. Mathematical models are useful to interpret the different profiles, providing quantitative information about the kinetics of virus replication and the cell populations contributing to viral decay. We modeled proviral integration in short- and long-lived infected cells to compare viral kinetics under treatment with and without the integrase inhibitor raltegravir (RAL). We fitted the model to data obtained from participants treated with RAL-containing regimes or with a four-drug regimen of protease and reverse transcriptase inhibitors. Our model explains the existence and quantifies the three phases of HIV-1 RNA decay in RAL-based regimens vs. the two phases observed in therapies without RAL. Our findings indicate that HIV-1 infection is mostly sustained by short-lived infected cells with fast integration and a short viral production period, and by long-lived infected cells with slow integration but an equally short viral production period. We propose that these cells represent activated and resting infected CD4+ T-cells, respectively, and estimate that infection of resting cells represent ~4% of productive reverse transcription events in chronic infection. RAL reveals the kinetics of proviral integration, showing that in short-lived cells the pre-integration population has a half-life of ~7 hours, whereas in long-lived cells this half-life is ~6 weeks. We also show that the efficacy of RAL can be estimated by the difference in viral load at the start of the second phase in protocols with and without RAL. Altogether, we provide a mechanistic model of viral infection that parsimoniously explains the kinetics of viral load decline under multiple classes of antiretrovirals.

59 BASIC BIOLOGICAL SCIENCES↗

Non-exponential and oscillatory decays in quantum mechanics

The quantum-mechanical theory of the decay of unstable states is revisited. We show that the decay is non-exponential both in the short-time and long-time limits using a more physical definition of the decay rate than the one usually used. We report results of numerical studies based on Winter's model that may elucidate qualitative features of exponential and non-exponential decay more generally. The main exponential stage is related to the formation of a radiating state that maintains the shape of its wave function with exponentially diminishing normalization. We discuss situations where the radioactive decay displays several exponents. The transient stages between different regimes are typically accompanied by interference of various contributions and resulting oscillations in the decay curve. The decay curve can be fully oscillatory in a two-flavor generalization of Winter's model with some values of the parameters. We consider the implications of that result for models of the oscillations reported by GSI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pressure effects on the relaxation of an excited nitromethane molecule in an argon bath

Classical molecular dynamics simulations were performed to study the relaxation of nitromethane in an Ar bath (of 1000 atoms) at 300 K and pressures 10, 50, 75, 100, 125, 150, 300, and 400 atm. The molecule was instantaneously excited by statistically distributing 50 kcal/mol among the internal degrees of freedom. At each pressure, 1000 trajectories were integrated for 1000 ps, except for 10 atm, for which the integration time was 5000 ps. The computed ensemble-averaged rotational energy decay is ∼100 times faster than the vibrational energy decay. Both rotational and vibrational decay curves can be satisfactorily fit with the Lendvay-Schatz function, which involves two parameters: one for the initial rate and one for the curvature of the decay curve. The decay curves for all pressures exhibit positive curvature implying the rate slows as the molecule loses energy. The initial rotational relaxation rate is directly proportional to density over the interval of simulated densities, but the initial vibrational relaxation rate decreases with increasing density relative to the extrapolation of the limiting low-pressure proportionality to density. The initial vibrational relaxation rate and curvature are fit as functions of density. For the initial vibrational relaxation rate, the functional form of the fit arises from a combinatorial model for the frequency of nitromethane “simultaneously” colliding with multiple Ar atoms. Roll-off of the initial rate from its low-density extrapolation occurs because the cross section for collision events with L Ar atoms increases with L more slowly than L times the cross section for collision events with one Ar atom. The resulting density-dependent functions of the initial rate and curvature represent, reasonably well, all the vibrational decay curves except at the lowest density for which the functions overestimate the rate of decay. The decay over all gas phase densities is predicted by extrapolating the fits to condensed-phase densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A COMPREHENSIVE ANALYSIS OF SWIFT/X-RAY TELESCOPE DATA. IV. SINGLE POWER-LAW DECAYING LIGHT CURVES VERSUS CANONICAL LIGHT CURVES AND IMPLICATIONS FOR A UNIFIED ORIGIN OF X-RAYS

By systematically analyzing the Swift/XRT light curves detected before 2009 July, we find 19 light curves that monotonously decay as a single power law (SPL) with an index of 1 approx 1.7 from tens (or hundreds) of seconds to approx10{sup 5} s post the gamma-ray burst (GRB) trigger. They are apparently different from the canonical light curves characterized by a shallow-to-normal decay transition. We compare the observations of the prompt gamma rays and the X-rays for these two samples of GRBs (SPL vs. canonical). No statistical difference is found in the prompt gamma-ray properties for the two samples. The X-ray properties of the two samples are also similar, although the SPL sample tends to have a slightly lower neutral hydrogen absorption column for the host galaxies and a slightly larger energy release compared with the canonical sample. The SPL X-ray Telescope (XRT) light curves in the burst frame gradually merge into a conflux, and their luminosities at 10{sup 5} s are normally distributed at log L/ergs s{sup -1} = 45.6 +- 0.5. The normal decay segment of the canonical XRT light curves has the same feature. Similar to the normal decay segment, the SPL light curves satisfy the closure relations and therefore can be roughly explained with external shock models. In the scenario that the X-rays are the afterglows of the GRB fireball, our results indicate that the shallow decay would be due to energy injection into the fireball and the total energy budget after injection for both samples of GRBs is comparable. More intriguing, we find that a prior X-ray emission model proposed by Yamazaki is more straightforward to interpret the observed XRT data. We show that the zero times (T {sub 0}) of the X-rays are 10{sup 2}-10{sup 5} s prior to the GRB trigger for the canonical sample, and satisfy a log-normal distribution. The negligible T {sub 0}'s of the SPL sample are consistent with being the tail of T {sub 0} distributions at low end, suggesting that the SPL sample and the canonical sample may be from a same parent sample. Referenced to T {sub 0}, the canonical XRT light curves well trace the SPL light curves. The T {sub 0}'s of the canonical light curves in our analysis are usually much larger than the offsets of the known precursors from the main GRBs. If the prior emission hypothesis is real, the X-ray emission is better interpreted within the external shock models based on the spectral and temporal indices of the X-rays. The lack of detection of a jet-like break in most XRT light curves implies that the opening angle of the prior emission jet would be usually large.

79 ASTRONOMY AND ASTROPHYSICS↗

Interatomic Coulombic decay in a He dimer: Ab initio potential-energy curves and decay widths

The energy gained by either of the two helium atoms in a helium dimer through simultaneous ionization and excitation can be efficiently transferred to the other helium atom, which then ionizes. The respective relaxation process called interatomic Coulombic decay (ICD) is the subject of the present paper. Specifically, we are interested in ICD of the lowest of the ionized excited states, namely, the He{sup +}(n=2)He states, for which we calculated the relevant potential-energy curves and the interatomic decay widths. The full-configuration interaction method was used to obtain the potential-energy curves. The decay widths were computed by utilizing the Fano ansatz, Green's-function methods, and the Stieltjes imaging technique. The behavior of the decay widths with the interatomic distance is examined and is elucidated, whereby special emphasis is given to the asymptotically large interatomic separations. Our calculations show that the electronic ICD processes dominate over the radiative decay mechanisms over a wide range of interatomic distances. The ICD in the helium dimer has recently been measured by Havermeier et al. [Phys. Rev. Lett. 104, 133401 (2010)]. The impact of nuclear dynamics on the ICD process is extremely important and is discussed by Sisourat et al. [Nat. Phys. 6, 508 (2010)] based on the ab initio data computed in the present paper.

74 ATOMIC AND MOLECULAR PHYSICS↗

{beta} decay of the {pi}f{sub 5/2} ground state of {sup 77}Cu studied with 225 MeV and 0.2 MeV purified radioactive beams

Isobarically purified beams of {sup 77}Cu with energies of 225 and 0.2 MeV were used at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory to study {beta} decay into states in {sup 77}Zn. Data taken at 225 MeV allowed the determination of absolute branching ratios relative to the decay of {sup 77}Cu for this {beta} decay as well as its daughters. From these we obtained a refined {beta}-delayed neutron emission probability of 30.3(22)% and a probability that the decay proceeds through {sup 77}Zn{sup g} of 49.1(26)%. A total of 64 {gamma} rays were placed in a level scheme for {sup 77}Zn containing 35 excited states including one state above the neutron separation energy, whereas two {gamma} rays were observed for the {beta}n branch to states in {sup 76}Zn. The growth and decay curves of some prominent {gamma} rays indicate a single {beta}-decaying state with a half-life of 480(9) ms. The decay pattern for {sup 77}Cu, with observed feeding of 8(3)% to 7/2{sup +} {sup 77}Zn{sup g} and 6(3)% to 1/2{sup -} {sup 77}Zn{sup m}, in contrast to the large feeding observed for decay of {pi}p{sub 3/2} {sup 73}Cu{sup g} to 1/2{sup -} {sup 73}Zn{sup g}, strongly suggests a {pi}f{sub 5/2} ground state for the studied {sup 77}Cu activity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of defects on the photoluminescence kinetics in GaN/AlN quantum-dot structures

The influence of defects in the AlN barrier on photoluminescence decay after pulse excitation is studied for structures with GaN quantum dots in an AlN matrix. For these quantum-dot structures, it is found that the initial part of the decay curves corresponds to fast photoluminescence decay. Comparison of the photoluminescence-decay curves for the GaN/AlN quantum-dot structures and AlN layers without quantum dots shows that fast decay is defined by the contribution of the photoluminescence band related to defects in the AlN matrix.

36 MATERIALS SCIENCE↗

Analysis of the Pressure-Pulse Propagation in Rock: a New Approach to Simultaneously Determine Permeability, Porosity, and Adsorption Capacity

Permeability estimation from pressure-pulse decay method is complicated by two facts: (1) the decay curve often deviates from the single-exponential behavior in the early time period and (2) possible existence of gas adsorption. Both the two factors cause significant permeability error in most of pressure-pulse decay methods. In this paper, we first present a thorough analysis of pressure-pulse propagation process to reveal the mechanism behind the early time and later time behaviors of pressure decay curve. Inspired by the findings from these analyses, a new scaled pressure is proposed which can: (1) be easily used to distinguish the early time and later time data and (2) make the decay curves of all cases into a single 1:1 straight line for later time. A new data-proceeding method, which calculates the apparent porosity and permeability using the same set of measured data, is then developed. The new method could not only remove the effects of the adsorption on the permeability estimation, but also identify the apparent porosity as well as proper adsorption model and parameters. The proposed method is verified by comparing with true values and calculated values through numerical simulations that cover variations in typical rock properties (porosity, permeability, slippage, and adsorption) and the experiment configurations. It is found that the new method is accurate and reliable for all test cases, whereas the Brace’s and Cui’s approaches may cause permeability error in some cases. Lastly, the new method has been successfully applied to real data measured in pressure-pulse decay experiments involving different types of rocks and gases.

58 GEOSCIENCES↗

Photoluminescence and energy storage traps in CaTiO{sub 3}:Pr{sup 3+}

Red-emitting CaTiO{sub 3}:Pr{sup 3+} phosphors are fabricated using a solid state method and structurally characterized by X-ray diffraction and field emission scanning electron microscopy. The optical properties are investigated using photoluminescence emission, excitation, photoluminescence decay curves, diffused reflectance and thermoluminescence spectra, and persistent phosphorescence decay curves. The optimal fabrication temperatures for photoluminescence and persistent phosphorescence are found at 1200-1300 {sup o}C for photoluminescence and 1400 {sup o}C for persistent phosphorescence. The energy storage traps for persistent phosphorescence in the system are analyzed based on the dependence of photoluminescence and persistent phosphorescence on sintering temperature. The distribution of energy storage traps is further characterized by thermoluminescence spectra and the parameters of the traps are calculated. Oxygen vacancies as the main trapping centers play the key role for persistent phosphorescence in CaTiO{sub 3}:Pr{sup 3+}.

36 MATERIALS SCIENCE↗

Half-life determination of heavy ions in a storage ring considering feeding and depleting background processes

Heavy-ion storage rings have relatively large momentum acceptance which allows for multiple ion species to circulate at the same time. This needs to be considered in radioactive decay measurements of highly charged ions, where atomic charge exchange reactions can significantly alter the intensities of parent and daughter ions. In this study, we investigate this effect using the decay curves of ion numbers in the recent 205 Tl 81+ bound-state beta decay experiment conducted using the Experimental Storage Ring at GSI Darmstadt. To understand the intricate dynamics of ion numbers, we present a set of differential equations that account for various atomic and nuclear reaction processes—bound state beta decay, atomic electron recombination and capture, and electron ionization. By incorporating appropriate boundary conditions, we develop a set of differential equations that accurately simulate the decay curves of various simultaneously stored ions in the storage ring: 205 Tl 81+ , 205 Pb 81+ , 205 Pb 82+ , 200 Hg 79+ , and 200 Hg 80+ . Through a quantitative comparison between simulations and experimental data, we provide insights into the detailed reaction mechanisms governing stored heavy ions within the storage ring. Our approach effectively models charge-changing processes, reduces the complexity of the experimental setup, and provides a simpler method for measuring the decay half-lives of highly charged ions in storage rings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synthesis, characterization and optical properties of NH{sub 4}Dy(PO{sub 3}){sub 4}

Polycrystalline powders of NH{sub 4}Dy(PO{sub 3}){sub 4} polyphosphate have been grown by the flux method. This compound was found to be isotopic with NH{sub 4}Ce(PO{sub 3}){sub 4} and RbHo(PO{sub 3}){sub 4}. It crystallizes in the monoclinic space group P2{sub 1/n} with unit cell parameters a=10.474(6) Å, b=9.011(4) Å, c=10.947(7) Å and β=106.64(3)°. The title compound has been transformed to triphosphate Dy(PO{sub 3}){sub 3} after calcination at 800 °C. Powder X-ray diffraction, infrared and Raman spectroscopies and the differential thermal analysis have been used to identify these materials. The spectroscopic properties have been investigated through absorption, excitation, emission spectra and decay curves of Dy{sup 3+} ion in both compounds at room temperature. The emission spectra show the characteristic emission bands of Dy{sup 3+} in the two compounds, before and after calcination. The integrated emission intensity ratios of the yellow to blue (I{sub Y}/I{sub B}) transitions and the chromaticity properties have been determined from emission spectra. The decay curves are found to be double-exponential. The non-exponential behavior of the decay rates was related to the resonant energy transfer as well as cross-relaxation between the donor and acceptor Dy{sup 3+} ions. The determined properties have been discussed as function of crystal structure of both compounds. They reveal that NH{sub 4}Dy(PO{sub 3}){sub 4} is promising for white light generation but Dy(PO{sub 3}){sub 3} is potential candidates in field emission display (FED) and plasma display panel (PDP) devices. - Graphical abstract: The CIE color coordinate diagrams showing the chromatic coordinates of Dy{sup 3+} luminescence in NH{sub 4}Dy(PO{sub 3}){sub 4} and Dy(PO{sub 3}){sub 3}. - Highlights: • The polycrystalline powders of NH{sub 4}Dy(PO{sub 3}){sub 4} and Dy(PO{sub 3}){sub 3} are synthesized. • The obtained powders are characterized. • The spectroscopic properties of Dy{sup 3+} ion are investigated. • Results are discussed as function of crystal structure and chemical composition. • The usefulness of NH{sub 4}Dy(PO{sub 3}){sub 4} and Dy(PO{sub 3}){sub 3} in optical devices is revealed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simple new methods for deducing lifetimes in recoil distance Doppler-shift measurements

In this work, new approaches for lifetime determination using data from recoil distance Doppler-shift experiments are presented based on the fundamental properties of the functions describing the time evolution of the population of excited nuclear states. To some extent, one of them represents a contraction of the well-known Differential decay-curve method (DDCM) by using the most reliable data point [the maximum of the $n_i(t)$ function describing the population of level $\textit{i}$ in time] and a purely numerical procedure avoiding any fitting of decay curves. The combination with the standard DDCM analysis is promising for improving the reliability and the precision of the results for the lifetimes obtained. The novel part of the approach consists of using a chain of equations at the consecutive maxima of the ni(t) functions, which allow us to precisely determine the ratio of the lifetimes of two consecutive levels and, in the case where one of these lifetimes is known, to determine the unknown one. In addition, a simple integral derivation of the lifetime is presented involving the peak areas measured at different distances, and an application of the first moments (expectation values and centroids in time) of the $n_i(t)$ functions for determining lifetimes is also demonstrated to be useful.

47 OTHER INSTRUMENTATION↗

Time domain-induced polarization geophysical data collected in the Rifle Floodplain, Colorado, USA

The IP data set was collected using a time domain-induced polarization (TDIP) method along 65 profiles of various lengths over the floodplain. Surface time domain?induced polarization (TDIP) data was collected to create the 3?D images of the complex electrical resistivity, in terms of magnitude and phase, which are associated with mineral precipitation and other lithological properties. The TDIP data was then used to estimate the spatial distribution of naturally reduced zones, which are known to be biogeochemical hotspots in floodplains having increased uranium and other redox-sensitive metal concentrations as well as high carbon contents. In the TDIP method, the transient decay of voltage is measured after current shut-off, typically in the form of an integral of decay curves over a predefined time window (so-called integral chargeability). TDIP measurements at the site were collected using the Syscal Iris Pro Switch equipment with a square-wave current injection, 50% duty cycle, and a pulse length of 2 s. The integral chargeability measurements were carried out using 20 windows during voltage decay between 240 and 1840 ms after current shut-off. Tomographic measurements were collected by deploying stainless steel electrodes with an electrode separation of 1.8 m and using a dipole-dipole ‘‘skip-2’’ and ‘‘skip-3’’ measuring protocol (i.e., for a dipoles length of 5.4 and 7.2 m, respectively). The sequence of dipole-dipole measurements was carefully arranged to (1) minimize unwanted electromagnetic coupling effects in the data, avoiding potential measurements with electrodes located inside the current dipole, (2) prevent voltage measurements using electrodes, which might be polarized due to previous current injection, and (3) increase the signal-to-noise ratio for an intended exploration depth of 8 m, i.e., the bottom of the aquifer. All measurements were collected as normal and reciprocal pairs for estimation of the data error. The IP measurements were collected with symmetric arrays (i.e., the measuring equipment placed at the center of the electrode array) with a maximum of 36 electrodes, considering that longer profiles revealed a significant increase in the normal-reciprocal misfit for the measurements of the decay curve, probably due to greater impact of electromagnetic coupling on the data. The TDIP data sets were inverted in a twodimensional domain along each transect using CRTomo, which is a smoothness-constraint inversion code based on a finite element algorithm. The resistivity and phase shift values at each pixel were then assigned at the corresponding point within the 3-D floodplain domain (the black rectangle Figure 1b) and used in the 3-D estimation. The TDIP inversion results provided the distribution of the complex resistivity, expressed in terms of its magnitude and phase-shift. The analysis of the normal-reciprocal misfit was used to estimate the relative error. We removed the measurement with smallest voltage difference (<2 mV), representing about 2% variations in the data. For the inversion of TDIP measurements, chargeability values were linearly converted to frequency domain phase values (at the fundamental frequency of 0.125 Hz), by assuming a constant-phase response. This approach has been demonstrated to provide consistent results in previous studies

54 ENVIRONMENTAL SCIENCES↗