A digital data quality monitor for application in the Nascom network data transmission system
Digital data quality monitor for Nascom network data transmission system applications
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Digital data quality monitor for Nascom network data transmission system applications
Plural channel data transmission system with quadrature modulation and complementary demodulation
The performance of a digital optical data transmission system is specified by the probability that the system erroneously decides a signal has or has not been transmitted. Two factors which induce signal fading and thereby decrease system performance are atmospheric scintillation and transmitter pointing inaccuracy. A channel simulator was developed that is capable of producing the effects of both atmospheric scintillation and the transmitter pointing problem for a neodymium-yag optical data transmission systems. Comparison of data taken from the modulated intensity of a beam having been transmitted through the channel simulator with experimental data from GEOS-B argon laser transmission through the atmosphere to a low earth-orbiting satellite indicates that the modulated signal intensity is log-normal to the degree of measured atmospheric scintillation.
Phase shift data transmission system with pseudo-noise synchronization code modulated with digital data into single channel for spacecraft communication
The authors have been developing a wireless data transmission system to monitor the performance of a geological disposal system for radioactive waste. The system's concepts, advantages, and a recent development focused on reducing transmitter size to suit narrow spaces such as bentonite buffers and boreholes. A wireless transmitter with a built-in temperature sensor and a connector for external sensors has been developed, measuring 130 mm in length and 50 mm in diameter. The capability of the transmitter was confirmed by transmission tests on the ground and in a bentonite block. (authors)
Scheme for coding and compressing data signals for transmission are compared by new analytical technique. Transmission rate of several schemes are plotted for direct comparison and evaluation.
A method of transmitting data packets, where randomness is added to the schedule. Universal broadcast schedules using encoding and randomization techniques are also discussed, together with optimal randomized schedules and an approximation algorithm for finding near-optimal schedules.
The scheme is suggested for developing the optical communication line based on the principle of code division of multiple access with matched acousto-optical filters and a 16-bit long Walsh sequence. Results of modelling show that such a line can operate if adjacent spectral lines are separated by at least double the Rayleigh criterion. (optical information transmission)
The main problems of providing a high-speed operation semiconductor lasers with a vertical microcavity (so-called “vertical-cavity surface-emitting lasers”) under amplitude modulation and ways to solve them have been considered. The influence of the internal properties of the radiating active region and the electrical parasitic elements of the equivalent circuit of lasers are discussed. An overview of approaches that lead to an increase of the cutoff parasitic frequency, an increase of the differential gain of the active region, the possibility of the management of mode emission composition and the lifetime of photons in the optical microcavities, and reduction of the influence of thermal effects have been presented. The achieved level of modulation bandwidth of ∼30 GHz is close to the maximum achievable for the classical scheme of the direct-current modulation, which makes it necessary to use a multilevel modulation format to further increase the information capacity of optical channels constructed on the basis of vertical-cavity surface-emitting lasers.
Following the success of the VLBI Space Observatory Program (VSOP), a next generation space VLBI mission (VSOP-2) is currently being planned. We expect the data rate of more than 1 Gbps to get more sensitivity. Here we will present: (1) How to sample the data (on board), including the radiation test results which show we can have the 10 Gbps sampler LSI which can use in space; (2) Possibility of the bit rate more than 1 Gbps to downlink the VLBI data. We studied the link budget for the wide band data transmission, and discussed the various ideas which can get more than 1 Gbps; and (3) What kind of VLBI tracking station and recording system will be expected for the VSOP-2 mission? We will present the idea of using normal radio telescopes as a tracking station, and also review the possibility of recording and processing at the tracking stations and correlators.
System for lunar photography and data transmission
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Matched-filter detection of binary signals is discussed in terms of the probability of bit error. The equations for the probability of error are derived for coherent phase shift keying, and coherent frequency shift keying (FSK). Suboptimum detection of FSK signals is also discussed for discriminators.
The objectives of Skylab Experiment M093 were to measure electrocardiographic signals during spaceflight, to elucidate the electrophysiological basis for the changes observed, and to assess the effect of the change on the human cardiovascular system. Vectorcardiographic methods were used to quantitate changes, standardize data collection, and to facilitate reduction and statistical analysis of data. In this report the authors describe the M093 experiment design, the data transmission system, data reduction methods, and the analysis of data from the three Skylab missions. The report also includes clinical applications of the techniques developed for Skylab Experiment M093.
In this work, modernized data acquisition systems of the Andyrchi and Carpet-3 shower facilities with automated data preprocessing and data transmission systems to the observatory of the Terskol Branch of the Institute of Astronomy are described. To solve joint problems on searching transient sources, data from the Andyrchi and Carpet facilities are processed and transmitted to the observatory of the Terskol Branch of the Institute of Astronomy in the form of astronomic coordinates for observations with an optical telescope.
Systems, apparatuses, and methods for reducing the toggle rates on buses are disclosed. A computing system includes a source which provides packets for transmission on a bus. The packet is compressed by a compression engine. The compressed data format of the packet includes locations (bit positions) referred to as holes which do not include valid data. A bus configuration module identifies the locations of the holes and replaces the holes with information from a previous packet transmitted earlier on the bus. The bus configuration module also determines a new transmission bus width for the packet for lowering the bus toggle rate on the bus during transmission.
Scientific data transmission systems signal design considerations for Apollo lunar exploration missions