Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Centers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

National Space Science Data Center data archive and distribution service (NDADS) automated retrieval mail system user's guide

The National Space Science Data Center (NSSDC) has developed an automated data retrieval request service utilizing our Data Archive and Distribution Service (NDADS) computer system. NDADS currently has selected project data written to optical disk platters with the disks residing in a robotic 'jukebox' near-line environment. This allows for rapid and automated access to the data with no staff intervention required. There are also automated help information and user services available that can be accessed. The request system permits an average-size data request to be completed within minutes of the request being sent to NSSDC. A mail message, in the format described in this document, retrieves the data and can send it to a remote site. Also listed in this document are the data currently available.

Perry, Charleen M.↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of hydrogen infrastructure for the feasibility, economics, and sustainability of a fuel cell powered data center

Data centers used for internet data services, cloud computing, and/or data storage consume vast amounts of electricity and are increasing rapidly in capacity. Consequently, their power consumption has raised concerns about energy sustainability and environmental impacts. Large-scale, on-site renewable energy could help reduce data centers’ carbon footprint; however, wind and solar power alone cannot provide an uninterrupted power supply to computer servers due to their natural variability. Instead, reliable power integration can be achieved by using fuel cells powered by hydrogen from sustainable resources (e.g., wind and solar energy). Establishing a hydrogen infrastructure will be critical for realizing these benefits and establishing fuel cells as a viable power source for data centers. Here, to facilitate the development of novel carbon-free fuel cell data enters, this paper presents renewable power integrated with hydrogen infrastructures in four scenarios to provide reliable hydrogen supply from production to storage. Various paths were analyzed toward a hydrogen supply infrastructure by determining the proper component sizes and calculating the cost of meeting the server load. We used a microgrid modeling software, Hybrid Optimization of Multiple Energy Resources (HOMER), and studied the feasibility of fuel cell powered data centers employing renewable hydrogen. The modeling results show various renewable integration configurations to meet reliable and sustainable power requirement under four scenarios for a carbon-free data center.

08 HYDROGEN↗

Sustainability, Feasibility, and Economics of a Fuel Cell-Powered Data Center

Data centers, used for cloud computing or data storage, consume huge amounts of power and are increasing rapidly in number, and consequently, this increase in power consumption has raised concerns with green and sustainable energy supplies to minimize carbon emissions. Significant renewable power can be a carbon-free energy source to reduce the carbon footprint of a data center; however, direct integration of wind and solar power with data center causes concern of the power quality for uninterrupted power supply to computer servers. The reliable power supply can be accomplished by using power produced from fuel cells fueled by hydrogen. If fed with hydrogen derived from renewable sources, fuel cells will realize carbon-free data centers. This presentation shows various renewable-integration scenarios to meet reliable and sustainable power requirements for a data center.

25 ENERGY STORAGE↗

National Space Science Data Center and World Data Center A for Rockets and Satellites - Ionospheric data holdings and services

The activities and services of the National Space Science data Center (NSSDC) and the World Data Center A for Rockets and Satellites (WDC-A-R and S) are described with special emphasis on ionospheric physics. The present catalog/archive system is explained and future developments are indicated. In addition to the basic data acquisition, archiving, and dissemination functions, ongoing activities include the Central Online Data Directory (CODD), the Coordinated Data Analysis Workshopps (CDAW), the Space Physics Analysis Network (SPAN), advanced data management systems (CD/DIS, NCDS, PLDS), and publication of the NSSDC News, the SPACEWARN Bulletin, and several NSSD reports.

Bilitza, D.↗

Big Federal Data Centers Implementing FAIR Data Principles: ARM Data Center Example

Atmospheric Radiation Measurement (ARM) is a multi-laboratory/multi-institutional, US Department of Energy Office of Science National User Facility. ARM’s data is currently hosted at the ARM Data Center (ADC) in Oak Ridge, Tennessee. The ADC holds more than 12,000 data products, with a total holding of more than 1.8 PB of data that dates back to 1992. This includes data from instruments, value-added products, model outputs, field campaigns, and principle investigator contributed data. In this paper, we discuss how big federal scientific data centers, such as ARM, that use modern and scalable architecture apply findable, accessible, interoperable, and reusable (FAIR) data principles to improve overall efficiency. These principles mainly emphasize machine-to-machine interactions that are directly applicable to ARM because of its data volume.

Devarakonda, Ranjeet↗

National Space Science Data Center (NSSDC) Data Listing

Satellite and nonsatellite data available from the National Space Science Data Center are listed. The Satellite Data listing includes the spacecraft name, launch date, and an alphabetical list of experiments. The Non-Satellite Data listing contains ground based data, models, computer routines, and composite spacecraft data. The data set name, data form code, quantity of data, and the time space covered are included in the data sets of both listings where appropriate. Geodetic tracking data sets are also included.

Source record↗

Goddard Atmospheric Composition Data Center: Aura Data and Services in One Place

The Goddard Atmospheric Composition Data and Information Services Center (AC-DISC) is a portal to the Atmospheric Composition specific, user driven, multi-sensor, on-line, easy access archive and distribution system employing data analysis and visualization, data mining, and other user requested techniques for the better science data usage. It provides convenient access to Atmospheric Composition data and information from various remote-sensing missions, from TOMS, UARS, MODIS, and AIRS, to the most recent data from Aura OMI, MLS, HIRDLS (once these datasets are released to the public), as well as Atmospheric Composition datasets residing at other remote archive site.

Leptoukh, G.↗

Advanced Data Center Energy Opportunities: Cloud and Infrastructure CoP - Data Center Energy and Efficiency with AI Adoption

The NLR portion of the "Cloud & Infrastructure CoP - Data Center Energy and Efficiency with AI Adoption" web meeting will cover data center locations, energy use and load growth, best practices, performance metrics, transition to direct liquid cooled data center equipment, and NLR's approach to optimizing data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equation-based object-oriented modeling and simulation of data center cooling systems

In this paper, we introduce a newly developed open source data center package in the Modelica Buildings library to support modeling and simulation of cooling and control systems of data centers. The data center package contains major thermal and control component models, such as Computer Room Air Handler, Computer Room Air Conditioner, models of different subsystem configurations such as chillers with differently configured waterside economizers, as well as templates for different systems. Two case studies based on this package are performed to investigate the performances of the cooling and electrical system under normal conditions and emergency situations such as a blackout: one is for a data center powered by conventional energy, and the other is for a data center powered by renewable energy. Simulation results show that the dynamic modeling and multi-domain simulation in the Modelica-based tool make it convenient for users to investigate both normal and emergent operations for conventional and renewable data centers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New trends in photonic switching and optical networking architectures for data centers and computing systems [Invited]

The rapid increases in data traffic coupled with user preferences are driving the data center and computing system service providers to offer energy-efficient, intelligent, flexible, cost-effective, high-capacity, and low-latency data services without added complexity to the users. Disaggregated heterogeneous reconfigurable computing systems realized by photonic switching and interconnects can enhance throughput and energy efficiency for artificial intelligence/machine learning (AI/ML) workloads, especially when aided by the AI/ML-enhanced control plane. Photonic switching and new optical networking architectures are expected to solve many of these challenging problems. This paper discusses new trends in photonic switching and optical network architectures for future data centers and computing systems summarized as follows: (1) flat reconfigurable disaggregated computing enabled by high-radix photonic switching and interconnects in data centers; (2) chiplet-based computing architectures empowered by embedded photonics toward heterogeneous reconfigurable computing; (3) nanosecond-scale photonic switching in data centers and computing systems; (4) AI/ML in self-driving, application-aware, and situation-aware data centers; (5) the emergence of flexible networking for cloud computing, edge computing, and split computing, as well as flexible networking for 5G/6G RF-optical networks; and (6) the deployment of embedded co-designed silicon photonics being considered for future data centers.

Yoo, S. J. Ben (ORCID:0000000274201871)↗

Data Centers and Digital Assurance Introduction to Supply Chain and Cybersecurity for Data Centers, Session 1

The first session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort Workshop, held on October 30, 2025, introduced foundational concepts of Digital Assurance in the context of data center and grid integration. Sponsored by the U.S. Department of Energy, the workshop brought together utilities, data center operators, developers, and vendors to address cybersecurity and supply chain vulnerabilities. The session emphasized the growing criticality of data centers within the electric grid and the need for secure, real-time, bidirectional communication. Participants explored the principles of Digital Assurance, including cybersecurity, cyber-informed engineering (CIE), and lifecycle security, and applied a threat-vulnerability-consequence framework to identify and mitigate risks at the data center–grid interface. Discussions covered a range of threats such as spoofed dispatch signals and insider threats, architectural vulnerabilities like SCADA interfaces and insecure protocols, and potential consequences including cascading grid failures. The session also raised strategic questions about business value, vendor assurance, and defining cyber boundaries and responsibilities. This foundational workshop set the stage for deeper technical analysis and the development of actionable frameworks in subsequent sessions. Session 1 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Comparing datasets of volume servers to illuminate their energy use in data centers

As data centers proliferate, their energy intensity deserves close attention. Always-on operations and growing usage for cloud and other backend processes make servers the fundamental driver of data center energy use. Yet servers’ power draw under real-world conditions is poorly understood. This paper explores characteristics of volume servers that affect energy use, quantifying differences in power draw between higher-performing Standard Performance Evaluation Corporation (SPEC) and ENERGY STAR servers and that of a typical server. First, we establish general characteristics of the US installed base, before reporting hardware configurations from a major online retail website. We then compare idle power across three datasets (one unique to this paper) and explain their differences via the hardware characteristics to which power draw is most sensitive. We find idle server power demand to be significantly higher than benchmarks from ENERGY STAR and the industry-released SPEC database, and SPEC server configurations—and likely their power scaling—to be atypical of volume servers. Next, we examine power draw trends among high-performing servers across their load range to consider whether these trends are representative of volume servers, before inputting average idle power load values into a recent national server energy use model. Lastly, results from two surveys of IT professionals illustrate the incidence of more efficient equipment and operational practices in server rooms/closets. Future work should include server power field measurements in data centers of different sizes, accounting for variations in configurations and setting changes post-purchase, as well as investigating the linkage between time and server energy efficiency.

Fuchs, Heidi (ORCID:0000000300105411)↗