Engineering PapersSearch

SEARCH · Engineering Papers

Results for “DROGUE PARACHUTE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of Drogue Parachute Damping Effects Utilizing the Apollo Legacy Parachute Model

Drogue parachute damping is required to dampen the Orion Multi Purpose Crew Vehicle (MPCV) crew module (CM) oscillations prior to deployment of the main parachutes. During the Apollo program, drogue parachute damping was modeled on the premise that the drogue parachute force vector aligns with the resultant velocity of the parachute attach point on the CM. Equivalent Cm(sub q) and Cm(sub alpha) equations for drogue parachute damping resulting from the Apollo legacy parachute damping model premise have recently been developed. The MPCV computer simulations ANTARES and Osiris have implemented high fidelity two-body parachute damping models. However, high-fidelity model-based damping motion predictions do not match the damping observed during wind tunnel and full-scale free-flight oscillatory motion. This paper will present the methodology for comparing and contrasting the Apollo legacy parachute damping model with full-scale free-flight oscillatory motion. The analysis shows an agreement between the Apollo legacy parachute damping model and full-scale free-flight oscillatory motion.

Currin, Kelly M.

Scale drogue parachute model

Drogue parachute models, pilot parachute models, and their deployment bags were fabricated incorporating recommended design changes. These changes are described in detail.

Source record

Damping Effects of Drogue Parachutes on Orion Crew Module Dynamics

Currently, simulation predictions of the Orion Crew Module (CM) dynamics with drogue parachutes deployed are under-predicting the amount of damping as seen in free-flight tests. The Apollo Legacy Chute Damping model has been resurrected and applied to the Orion system. The legacy model has been applied to predict CM damping under drogue parachutes for both Vertical Spin Tunnel free flights and the Pad Abort-1 flight test. Comparisons between the legacy Apollo prediction method and test data are favorable. A key hypothesis in the Apollo legacy drogue damping analysis is that the drogue parachutes' net load vector aligns with the CM drogue attachment point velocity vector. This assumption seems reasonable and produces good results, but has never been quantitatively proven. The wake of the CM influences the drogue parachutes, which makes performance predictions of the parachutes difficult. Many of these effects are not currently modeled in the simulations. A forced oscillation test of the CM with parachutes was conducted in the NASA LaRC 20-Ft Vertical Spin Tunnel (VST) to gather additional data to validate and refine the Apollo legacy drogue model. A second loads balance was added to the original Orion VST model to measure the drogue parachute loads independently of the CM. The objective of the test was to identify the contribution of the drogues to CM damping and provide additional information to quantify wake effects and the interactions between the CM and parachutes. The drogue parachute force vector was shown to be highly dependent on the CM wake characteristics. Based on these wind tunnel test data, the Apollo Legacy Chute Damping model was determined to be a sufficient approximation of the parachute dynamics in relationship to the CM dynamics for preliminary entry vehicle system design. More wake effects should be included to better model the system. These results are being used to improve simulation model fidelity of CM flight with drogues deployed, which has been identified by the project as key to a successful Orion Critical Design Review.

Aubuchon, Vanessa V.

Damping Effects of Drogue Parachutes on Orion Crew Module Dynamics

Because simulations of the Orion Crew Module (CM) dynamics with drogue parachutes deployed were under-predicting the amount of damping seen in free-flight tests, an attach-point damping model was applied to the Orion system. A key hypothesis in this model is that the drogue parachutes' net load vector aligns with the CM drogue attachment point velocity vector. This assumption seems reasonable and has historically produced good results, but has never been experimentally verified. The wake of the CM influences the drogue parachutes, which makes performance predictions of the parachutes difficult. Many of these effects are not currently modeled in the simulations. A forced oscillation test of the CM with parachutes was conducted in the NASA LaRC 20-Ft Vertical Spin Tunnel (VST) to gather additional data to validate and refine the attach-point damping model. A second loads balance was added to the original Orion VST model to measure the drogue parachute loads independently of the CM. The objective of the test was to identify the contribution of the drogues to CM damping and provide additional information to quantify wake effects and the interactions between the CM and parachutes. The drogue parachute force vector was shown to be highly dependent on the CM wake characteristics. Based on these wind tunnel test data, the attach-point damping model was determined to be a sufficient approximation of the parachute dynamics in relationship to the CM dynamics for preliminary entry vehicle system design. More wake effects should be included to better model the system.

Aubuchon, Vanessa V.

Low-Speed Flight Dynamic Tests and Analysis of the Orion Crew Module Drogue Parachute System

A test of a dynamically scaled model of the NASA Orion Crew Module (CM) with drogue parachutes was conducted in the NASA-Langley 20-Foot Vertical Spin Tunnel. The primary test objective was to assess the ability of the Orion Crew Module drogue parachute system to adequately stabilize the CM and reduce angular rates at low subsonic Mach numbers. Two attachment locations were tested: the current design nominal and an alternate. Experimental results indicated that the alternate attachment location showed a somewhat greater tendency to attenuate initial roll rate and reduce roll rate oscillations than the nominal location. Comparison of the experimental data to a Program To Optimize Simulated Trajectories (POST II) simulation of the experiment yielded results for the nominal attachment point that indicate differences between the low-speed pitch and yaw damping derivatives in the aerodynamic database and the physical model. Comparisons for the alternate attachment location indicate that riser twist plays a significant role in determining roll rate attenuation characteristics. Reevaluating the impact of the alternate attachment points using a simulation modified to account for these results showed significantly reduced roll rate attenuation tendencies when compared to the original simulation. Based on this modified simulation the alternate attachment point does not appear to offer a significant increase in allowable roll rate over the nominal configuration.

Hahne, David E.

Development Of An 80'-Diameter Ribbon Drogue Parachute For The NASA X-38 Vehicle

The NASA X-38 program required a larger, more robust drogue parachute. A multi-organizational team from NASA, Sandia National Laboratories, United Space Alliance, and Pioneer Aerospace Corporation has developed and tested a new 80-ft.-dia., quarter-spherical, ribbon drogue parachute. The design requirements, design specifics, margin analyses, and results of testing are all discussed herein. Some of the weight advantages of switching from Kevlar to Zylon for radial, line and riser materials are presented.

Behr, Vance L.

Solid Rocket Booster Large Main and Drogue Parachute Reliability Analysis

The parachutes on the Space Transportation System (STS) Solid Rocket Booster (SRB) are the means for decelerating the SRB and allowing it to impact the water at a nominal vertical velocity of 75 feet per second. Each SRB has one pilot, one drogue, and three main parachutes. About four minutes after SRB separation, the SRB nose cap is jettisoned, deploying the pilot parachute. The pilot chute then deploys the drogue parachute. The drogue chute provides initial deceleration and proper SRB orientation prior to frustum separation. At frustum separation, the drogue pulls the frustum from the SRB and allows the main parachutes that are mounted in the frustum to unpack and inflate. These chutes are retrieved, inspected, cleaned, repaired as needed, and returned to the flight inventory and reused. Over the course of the Shuttle Program, several improvements have been introduced to the SRB main parachutes. A major change was the replacement of the small (115 ft. diameter) main parachutes with the larger (136 ft. diameter) main parachutes. Other modifications were made to the main parachutes, main parachute support structure, and SRB frustum to eliminate failure mechanisms, improve damage tolerance, and improve deployment and inflation characteristics. This reliability analysis is limited to the examination of the SRB Large Main Parachute (LMP) and drogue parachute failure history to assess the reliability of these chutes. From the inventory analysis, 68 Large Main Parachutes were used in 651 deployments, and 7 chute failures occurred in the 651 deployments. Logistic regression was used to analyze the LMP failure history, and it showed that reliability growth has occurred over the period of use resulting in a current chute reliability of R = .9983. This result was then used to determine the reliability of the 3 LMPs on the SRB, when all must function. There are 29 drogue parachutes that were used in 244 deployments, and no in-flight failures have occurred. Since there are no observed drogue chute failures, Jeffreys Prior was used to calculate a reliability of R =.998. Based on these results, it is concluded that the LMP and drogue parachutes on the Shuttle SRB are suited to their mission and changes made over their life have improved the reliability of the parachute.

Clifford, Courtenay B.

A Comparison of Three Algorithms for Orion Drogue Parachute Release

The Orion Multi-Purpose Crew Vehicle is susceptible to ipping apex forward between drogue parachute release and main parachute in ation. A smart drogue release algorithm is required to select a drogue release condition that will not result in an apex forward main parachute deployment. The baseline algorithm is simple and elegant, but does not perform as well as desired in drogue failure cases. A simple modi cation to the baseline algorithm can improve performance, but can also sometimes fail to identify a good release condition. A new algorithm employing simpli ed rotational dynamics and a numeric predictor to minimize a rotational energy metric is proposed. A Monte Carlo analysis of a drogue failure scenario is used to compare the performance of the algorithms. The numeric predictor prevents more of the cases from ipping apex forward, and also results in an improvement in the capsule attitude at main bag extraction. The sensitivity of the numeric predictor to aerodynamic dispersions, errors in the navigated state, and execution rate is investigated, showing little degradation in performance.

Matz, Daniel A.

Development and Testing of a Drogue Parachute System for X-37 ALTV/B-52H Separation

Multiple scenarios were identified in which the X-37 approach and landing test vehicle (ALTV) catastrophically recontacts the B-52H carrier aircraft after separation. The most cost-effective recontact risk mitigation is the prelaunch deployment of a drogue parachute that is released after the X-37 ALTV has safely cleared the B-52H. After release, a fully-inflated drogue parachute takes 30 min to reach ground and results in a large footprint that excessively restricts the days available for flight. To reduce the footprint, a passive collapse mechanism consisting of an elastic reefing line attached to the parachute skirt was developed. At flight loads the elastic is stretched, allowing full parachute inflation. After release, drag loads drop dramatically and the elastic line contracts, reducing the frontal drag area. A 50 percent drag reduction results in an approximately 75 percent ground footprint reduction. Eleven individual parachute designs were evaluated at flight load dynamic pressures in the High Velocity Airflow System (HIVAS) at the Naval Air Warfare Center (NAWC), China Lake, California. Various options for the elastic reefing system were also evaluated at HIVAS. Two best parachute designs were selected from HIVAS to be carried forward to flight test. Detailed HIVAS test results are presented in this report.

Whitmore, Stephen A.

Development and Testing of a Drogue Parachute System for X-37 ALTV/B-52H Separation

Multiple scenarios were identified in which the X-37 approach and landing test vehicle (ALTV) catastrophically recontacts the B-52H carrier aircraft after separation. The most cost-effective recontact risk mitigation is the prelaunch deployment of a drogue parachute that is released after the X-37 ALTV has safely cleared the B-52H. After release, a fully-inflated drogue parachute takes 30 min to reach ground and results in a large footprint that excessively restricts the days available for flight. To reduce the footprint, a passive collapse mechanism consisting of an elastic reefing line attached to the parachute skirt was developed. At flight loads the elastic is stretched, allowing full parachute inflation. After release, drag loads drop dramatically and the elastic line contracts, reducing the frontal drag area. A 50-percent drag reduction results in an approximately 75-percent ground footprint reduction. Eleven individual parachute designs were evaluated at flight load dynamic pressures in the High Velocity Airflow System (HIVAS) at the Naval Air Warfare Center (NAWC), China Lake, California. Various options for the elastic reefing system were also evaluated at HIVAS. Two best parachute designs were selected from HIVAS to be carried forward to flight test. Detailed HIVAS test results are presented in this report.

Whitmore, Stephen A.

Subscale Test Program for the Orion Conical Ribbon Drogue Parachute

A subscale wind tunnel test program for Orion's conical ribbon drogue parachute is under development. The desired goals of the program are to quantify aerodynamic performance of the parachute in the wake of the entry vehicle, including understanding of the coupling of the parachute and command module dynamics, and an improved understanding of the load distribution within the textile elements of the parachute. The test program is ten percent of full scale conducted in a 3x2.1 m (10x7 ft) closed loop subsonic wind tunnel. The subscale test program is uniquely suited to probing the aerodynamic and structural environment in both a quantitative and qualitative manner. Non-intrusive diagnostics, including Particle Image Velocimetry for wake velocity surveys, high speed pressure transducers for canopy pressure distribution, and a high speed photogrammetric reconstruction, will be used to quantify the parachute's performance.

parachute

Wind tunnel investigation of Space Shuttle Solid Rocket Booster drogue parachutes and deployment concepts

A wind tunnel test has been conducted on one-eighth scale models of the Space Shuttle Solid Rocket Booster drogue parachute system. The test included an investigation of four candidate drogue deployment concepts and a parametric steady state drag study of 20-degree conical ribbon parachutes. The results show that at least two of the four deployment concepts tested are viable candidates for the full scale deployment system. The interference free steady state drag results obtained show excellent agreement with available drop test results on large 20-degree conical ribbon parachutes.

Bacchus, D. L.

Extrapolating the Trends of Test Drop Data with Opening Shock Factor Calculations: the Case of the Orion Main and Drogue Parachutes Inflating to 1st Reefed Stage

We describe a new calculation of the opening shock factor C (sub k) characterizing the inflation performance of NASA's Orion spacecraft main and drogue parachutes opening under a reefing constraint (1st stage reefing), as currently tested in the Capsule Parachute Assembly System (CPAS) program. This calculation is based on an application of the Momentum-Impulse Theorem at low mass ratio (R (sub m) is less than 10 (sup -1)) and on an earlier analysis of the opening performance of drogues decelerating point masses and inflating along horizontal trajectories. Herein we extend the reach of the Theorem to include the effects of payload drag and gravitational impulse during near-vertical motion - both important pre-requisites for CPAS parachute analysis. The result is a family of C (sub k) versus R (sub m) curves which can be used for extrapolating beyond the drop-tested envelope. The paper proves this claim in the case of the CPAS Mains and Drogues opening while trailing either a Parachute Compartment Drop Test Vehicle or a Parachute Test Vehicle (an Orion capsule boiler plate). It is seen that in all cases the values of the opening shock factor can be extrapolated over a range in mass ratio that is at least twice that of the test drop data.

Potvin, Jean

Drogue parachute deployment dynamics of the space shuttle solid rocket booster

Theoretical analysis and experimental investigations are presented for two deployment concepts of the drogue parachute deployment for the space shuttle solid rocket booster. The analysis represents the motion of three coupled rigid bodies, with one of the bodies having variable mass and moment of inertia. The unfurling process of the parachute from the bag is idealized as the flow of a continuum out of a control surface. The pilot parachute or tethered nose cap is modeled as a flexible pendulum with a nonlinear spring and a moving support. Measured wind tunnel test data compare reasonably well with the theory.

Banerjee, A. K.

Proposed Framework for Determining Added Mass of Orion Drogue Parachutes

The Crew Exploration Vehicle (CEV) Parachute Assembly System (CPAS) project is executing a program to qualify a parachute system for a next generation human spacecraft. Part of the qualification process involves predicting parachute riser tension during system descent with flight simulations. Human rating the CPAS hardware requires a high degree of confidence in the simulation models used to predict parachute loads. However, uncertainty exists in the heritage added mass models used for loads predictions due to a lack of supporting documentation and data. Even though CPAS anchors flight simulation loads predictions to flight tests, extrapolation of these models outside the test regime carries the risk of producing non-bounding loads. A set of equations based on empirically derived functions of skirt radius is recommended as the simplest and most viable method to test and derive an enhanced added mass model for an inflating parachute. This will increase confidence in the capability to predict parachute loads. The selected equations are based on those published in A Simplified Dynamic Model of Parachute Inflation by Dean Wolf. An Ames 80x120 wind tunnel test campaign is recommended to acquire the reefing line tension and canopy photogrammetric data needed to quantify the terms in the Wolf equations and reduce uncertainties in parachute loads predictions. Once the campaign is completed, the Wolf equations can be used to predict loads in a typical CPAS Drogue Flight test. Comprehensive descriptions of added mass test techniques from the Apollo Era to the current CPAS project are included for reference.

Fraire, Usbaldo, Jr.

Drogue Parachute Effects on the Orion Crew Module Stability

A forced oscillation test of the Orion Crew Module (CM) was conducted in the Langley 20-Foot Vertical Spin Tunnel. The objective of the test was to quantify the rate damping characteristics of the CM-drogue chute system. Numerous configurations were tested to measure the influence of the chutes on the CM dynamic aerodynamics and, conversely, the influence of the CM on drogue performance. Results show that the CM-drogue system is well-damped at all combinations of frequency, amplitude, and Strouhal number. The wake of the CM significantly reduces the drogue chute riser line force, and the drogues have little upstream influence on the CM aerodynamics. These results are being used to improve simulation model fidelity of CM flight with drogues deployed, which has been identified by the project as key to a successful Orion Critical Design Review.

Aubuchon, Vanessa V.

An Investigation of the Dragonfly Mission Aeroshell/Parachute Dynamics through Subscale Drop Tests

The Dragonfly mission will place a rotorcraft/lander on Titan by 2034. The entry, descent, and landing system of the Dragonfly mission includes two parachutes: a drogue and a main. To provide needed data, subscale drop tests were used to conduct an experimental investigation of the aeroshell/parachute dynamics. The drop tests used a Disk-Gap-Band drogue parachute and two types of Ringslot main parachutes. All tests used a representative aeroshell which included the heatshield. All models were geometrically scaled to 16.7 percent. The model aeroshell had a diameter of 0.75 m. The model parachute nominal diameters were 0.9 m for the drogue and 2.78 m for the main. The aeroshell’s mass properties were dynamically scaled to simulate flight at an altitude of 4 km at Titan. This dynamic scaling allowed the conversion of model test results to full-scale Titan conditions. Onboard instrumentation on the aeroshell provided data on the rotation rates, from which the Euler angles were determined. Tests were conducted by lifting the models with a drone to an altitude of 350 m and dropping them inverted. Key results from these tests were: 1) the models were able to recover from the extreme inverted initial condition and settle to low-amplitude oscillations; 2) ninety nine percent of the time the oscillation amplitudes observed with the drogue parachute were 11.4 degrees or less; 3) ninety nine percent of the time the oscillation amplitudes observed with the 20 percent porosity main parachute were 15.4 degrees or less.

Parachutes

An Investigation of the Dragonfly Mission Aeroshell/Parachute Dynamics through Subscale Drop Tests

The Dragonfly mission will place a rotorcraft/lander on Titan by 2034. The entry, descent, and landing system of the Dragonfly mission includes two parachutes: a drogue and a main. To provide needed data, subscale drop tests were used to conduct an experimental investigation of the aeroshell/parachute dynamics. The drop tests used a Disk-Gap-Band drogue parachute and two types of Ringslot main parachutes. All tests used a representative aeroshell which included the heatshield. All models were geometrically scaled to 16.7 percent. The model aeroshell had a diameter of 0.75 m. The model parachute nominal diameters were 0.9 m for the drogue and 2.78 m for the main. The aeroshell’s mass properties were dynamically scaled to simulate flight at an altitude of 4 km at Titan. This dynamic scaling allowed the conversion of model test results to full-scale Titan conditions. Onboard instrumentation on the aeroshell provided data on the rotation rates, from which the Euler angles were determined. Tests were conducted by lifting the models with a drone to an altitude of 350 m and dropping them inverted. Key results from these tests were: 1) the models were able to recover from the extreme inverted initial condition and settle to low-amplitude oscillations; 2) ninety nine percent of the time the oscillation amplitudes observed with the drogue parachute were 11.4 degrees or less; 3) ninety nine percent of the time the oscillation amplitudes observed with the 20 percent porosity main parachute were 15.4 degrees or less.

Parachutes