Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Validation and uncertainty of DRF's for a 1"×2" NaI collimated detector for radioisotope holdup measurements

Detector response functions (DRFs) have become the subject of increasing scientific interest for the last thirty years in several industrial applications of radiation detection. These applications include gamma-ray, prompt gamma-ray, and X-ray spectrometry for elemental analysis and location as applied to mining, radio-tracing in medicine, and holdup source characterization. However, it is difficult to create a rigorous mathematical formulation of the DRF. Therefore, semi-empirical and stochastic approaches have been developed instead to construct detector and application specific DRFs. A DRF can be considered to be a function that converts the energy-dependent incidence of incoming source particles onto a detector into a detector response spectrum that simulates the experimental response. The DRF can also be used in the reverse sense in an inverse problem setting, as a step in the process of predicting the physical characteristics of an unknown source (e.g. the holdup problem and library spectra). Much of the recent work on DRFs has been performed by Gardner. He has developed accurate DRF models through semi-empirical curve fitting and Monte Carlo simulation. His DRFs for 3" X 3" NaI detectors have been developed with the experimental measurements taken by Heath and for 6"x6" bare (unshielded) NaI(Tl) detector data with single-energy sources centered on the detector face at a distance of 10 cm. There was agreement with the Heath benchmark detector measurements within two Poisson standard deviations of the measured data. DRFs have also been developed for other detectors such as high purity Germanium detectors and Si(Li) for the same geometries as NaI. Other than a few artifacts such as backscatter peaks, there was good agreement between simulated responses and the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADRAS-DRF user's manual.

The Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, and analyzing spectra to identify isotopes or to estimate flux profiles. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving researchers and other users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

Theisen, Lisa Anne↗

GADRAS-DRF User's Manual (V.18.5)

The Gamma Detector Response and Analysis Software - Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, and estimating source energy distributions from measured spectra. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

Horne, Steven M.↗

GADRAS-DRF 18.6 User's Manual

The Gamma Detector Response and Analysis Software–Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, and estimating source energy distributions from measured spectra. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADRAS-DRF 18.5 User's Manual

The Gamma Detector Response and Analysis Software--Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, and estimating source energy distributions from measured spectra. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

61 RADIATION PROTECTION AND DOSIMETRY↗

GADRAS-DRF Version 18 User's Manual

The Gamma Detector Response and Analysis Software Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation and provides analysis on measured spectra. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, estimating source energy distributions from measured spectra, and creating inject data. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GADRAS-DRF Enhancements for Safeguards – Custom Peak Fitting to Enhance Model Fitting and Isotopics

One major software update was accomplished within the Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) package. This update allows users to adjust individual peak fits for use in subsequent analysis processes within GADRAS-DRF. A graphical user interface (GUI) was implemented so users can see the effect of their fit adjustments on the spectrum. This new feature will enhance the capability of the previously funded auto-enrichment and peak-based 1D model fit feature that was implemented in FY23 (Fiscal Year). Isotopic analysis was performed using M400 data obtained from uranium standards and the isotopic assessment is given with and without manual peak adjustments.

07 ISOTOPE AND RADIATION SOURCES↗

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GADRAS-DRF for Safeguards (FY 2025 Mid-Year/Annual Report)

Task 1 – Extract GADRAS-DRF capabilities for a workflow intuitive to safeguards analysis. This task is almost complete. Significant improvements have been made to the functionality of customizing peak fits for use in the isotopics application, as well as peak-based FSA model analysis. The remaining tasks revolve around bug fixes, testing the application, and adding a density scroll bar to isotopics for real time analysis updates. The density scroll bar values will be reflected in summary tables and the self-shielding form accessed within isotopics.

97 MATHEMATICS AND COMPUTING↗

Validation and uncertainty quantification of detector response functions for a $1"×2"$ NaI collimated detector intended for inverse radioisotope source mapping applications

Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-FG-207B-02: Material Reconstruction for Spectral Computed Tomography with Detector Response Function

Purpose: Different from the conventional computed tomography (CT), spectral CT based on energy-resolved photon-counting detectors is able to provide the unprecedented material composition. However, an important missing piece for accurate spectral CT is to incorporate the detector response function (DRF), which is distorted by factors such as pulse pileup and charge-sharing. In this work, we propose material reconstruction methods for spectral CT with DRF. Methods: The polyenergetic X-ray forward model takes the DRF into account for accurate material reconstruction. Two image reconstruction methods are proposed: a direct method based on the nonlinear data fidelity from DRF-based forward model; a linear-data-fidelity based method that relies on the spectral rebinning so that the corresponding DRF matrix is invertible. Then the image reconstruction problem is regularized with the isotropic TV term and solved by alternating direction method of multipliers. Results: The simulation results suggest that the proposed methods provided more accurate material compositions than the standard method without DRF. Moreover, the proposed method with linear data fidelity had improved reconstruction quality from the proposed method with nonlinear data fidelity. Conclusion: We have proposed material reconstruction methods for spectral CT with DRF, whichprovided more accurate material compositions than the standard methods without DRF. Moreover, the proposed method with linear data fidelity had improved reconstruction quality from the proposed method with nonlinear data fidelity. Jiulong Liu and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-01: A Method to Quantify Lung SBRT Target Localization Accuracy Based On Digitally Reconstructed Fluoroscopy

Purpose: To develop a methodology based on digitally-reconstructed-fluoroscopy (DRF) to quantitatively assess target localization accuracy of lung SBRT, and to evaluate using both a dynamic digital phantom and a patient dataset. Methods: For each treatment field, a 10-phase DRF is generated based on the planning 4DCT. Each frame is pre-processed with a morphological top-hat filter, and corresponding beam apertures are projected to each detector plane. A template-matching algorithm based on cross-correlation is used to detect the tumor location in each frame. Tumor motion relative beam aperture is extracted in the superior-inferior direction based on each frame’s impulse response to the template, and the mean tumor position (MTP) is calculated as the average tumor displacement. The DRF template coordinates are then transferred to the corresponding MV-cine dataset, which is retrospectively filtered as above. The treatment MTP is calculated within each field’s projection space, relative to the DRF-defined template. The field’s localization error is defined as the difference between the DRF-derived-MTP (planning) and the MV-cine-derived-MTP (delivery). A dynamic digital phantom was used to assess the algorithm’s ability to detect intra-fractional changes in patient alignment, by simulating different spatial variations in the MV-cine and calculating the corresponding change in MTP. Inter-and-intra-fractional variation, IGRT accuracy, and filtering effects were investigated on a patient dataset. Results: Phantom results demonstrated a high accuracy in detecting both translational and rotational variation. The lowest localization error of the patient dataset was achieved at each fraction’s first field (mean=0.38mm), with Fx3 demonstrating a particularly strong correlation between intra-fractional motion-caused localization error and treatment progress. Filtering significantly improved tracking visibility in both the DRF and MV-cine images. Conclusion: We have developed and evaluated a methodology to quantify lung SBRT target localization accuracy based on digitally-reconstructed-fluoroscopy. Our approach may be useful in potentially reducing treatment margins to optimize lung SBRT outcomes. R01-184173.

60 APPLIED LIFE SCIENCES↗

Deployment Readiness Framework Subtask 1.1 (Literature Review)

Island and remote coastal communities face some of the most challenging environments for building, operating, and maintaining energy infrastructure, as well as the highest costs for electricity, fuels, and other essential energy sources. As sea-levels rise and storms become more intense and frequent, these communities and the energy infrastructure that supports coastal lives and livelihoods are also at increasing risk from natural hazards. To address these challenges, many coastal communities are envisioning energy solutions that will support the triple bottom line goals of the blue economy: economic growth, environmental sustainability, and social equity. Yet, island and remote coastal communities often face limited resources and capacity to tackle complex energy and coastal resilience issues. To support community-driven energy transitions in island and remote communities, and to better understand relationships between energy, community, and ecosystem resilience, the Department of Energy’s Water Power Technologies Office (WPTO) has initiated the development of a Deployment Readiness Framework (DRF). The objective of the work is to co-produce and test practical tools and approaches that assess the readiness of coastal communities for marine energy demonstration, deployment, and operation. The DRF aims to build on and support the Energy Transitions Initiative Partnership Program (ETIPP) and other community-oriented energy transition programs. This project is jointly led by Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL). The development of the DRF includes three main phases: 1) a learning phase involving stakeholder engagement and literature review to synthesize metrics of community readiness to advance through an energy transition and to understand the state of the research and practice of participatory science-policy processes in various sectors, 2) a design phase to define readiness approaches and tools that will be developed as part of the DRF, and 3) an implementation phase to create the applications and interfaces for WPTO and the national laboratories to interact with the DRF. All three phases include close collaboration with communities and end-users of the framework, first to identify gaps in the science and tools needed to achieve community-driven energy transition goals and second, to test and improve the framework iteratively. Through technical assistance programs like ETIPP and utilizing the completed DRF to understand the influencing factors which motivate or deter energy transitions, WPTO hopes to engage a number of near-term marine energy demonstration opportunities. Here we report on the results from the literature review (Subtask 1.1) to inform the stakeholder engagement (Subtask 1.2) and design phase (Task 2) of the project.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SL12-GADRAS-PD2Ka Annual Report

The GADRAS Development project comprises several elements that are all related to the Detector Response Function (DRF), which is the core of GADRAS. An ongoing activity is implementing continuous improvements in the accuracy and versatility of the DRF. The ability to perform rapid computation of the response of gammaray detectors for 3-D descriptions of source objects and their environments is a good example of a recent utilization of this versatility. The 3-D calculations, which execute several orders of magnitude faster than competing techniques, compute the response as an extension of the DRF so the radiation transport problem is never solved explicitly, thus saving considerable computational time. Maintenance of the Graphic User Interface (GUI) and extension of the GUI to enable construction of the 3-D source models is included in tasking for the GADRAS Development project. Another aspect of this project is application of the isotope identification algorithms for search applications. Specifically, SNL is tasked with development of an isotope-identification based search capability for use with the RSL-developed AVID system, which supports simultaneous operation of numerous radiation search assets. A Publically Available (PA) GADRAS-DRF application, which eliminates sensitive analysis components, will soon be available so that the DRF can be used by researchers at universities and corporations.

47 OTHER INSTRUMENTATION↗