Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DRAINING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Features of the Design of a Self-Draining Solar Power Plant with an Active Element

The calculation dependences for designing a self-draining solar power plant (SDSPP) with an active element in the form of a narrowing device of the Venturi tube are obtained. The calculation dependences for the transient modes in an SDSPP are analyzed from the point of view of the representations of the nonlinear nonequilibrium thermodynamics. It is shown that two steady operation modes of an SDSPP are possible: with and without a break of the jet. It is specified that both these modes merge when the consumption of the heat transfer fluid is equal to the critical value, for which the contraction ratio of the flow in the Venturi tube is defined, and differ when their values are higher than the critical value.

14 SOLAR ENERGY↗

Current fluctuation of electron and hole carriers in multilayer WSe{sub 2} field effect transistors

Two-dimensional materials have outstanding scalability due to their structural and electrical properties for the logic devices. Here, we report the current fluctuation in multilayer WSe{sub 2} field effect transistors (FETs). In order to demonstrate the impact on carrier types, n-type and p-type WSe{sub 2} FETs are fabricated with different work function metals. Each device has similar electrical characteristics except for the threshold voltage. In the low frequency noise analysis, drain current power spectral density (S{sub I}) is inversely proportional to frequency, indicating typical 1/f noise behaviors. The curves of the normalized drain current power spectral density (NS{sub I}) as a function of drain current at the 10 Hz of frequency indicate that our devices follow the carrier number fluctuation with correlated mobility fluctuation model. This means that current fluctuation depends on the trapping-detrapping motion of the charge carriers near the channel interface. No significant difference is observed in the current fluctuation according to the charge carrier type, electrons and holes that occurred in the junction and channel region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of Shift Ex-Core Calculations to a Detailed MSR Model

This report documents the collaborative research conducted between Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL) on applying the Monte Carlo neutronics code Shift to calculate the radiation dose rates for a detailed molten salt reactor (MSR) model based on the Molten Salt Breeder Reactor (MSBR). In this work scope, the ANL and ORNL teams worked together and applied Shift to calculate the radiological environments of this detailed MSR facility modeled with explicit geometries. The radiological conditions within the MSR facility were modeled for when the reactor is at two different operation modes: normal full power and drained state. The FW-CADIS hybrid method in Shift was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Dose rate maps showed that in the current MSBR numerical model, potential pathways exist for neutrons and gammas to stream through the 8-foot concrete shield to reach the top of the MSBR reactor cell. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the Shift simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates, which suggests that a steel liner in the tank model must be added for calculating the dose rates in the drain cell.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Battery Particle Simulation

Two simulations show the differences between a battery being drained at a slower rate, over a full hour, versus a faster rate, only six minutes (a tenth of an hour). In both cases battery particles go from being fully charged (green) to fully drained (red), but there are significant differences in the patterns of discharge based on the rate.

25 ENERGY STORAGE↗

High-Efficiency Harmonically Terminated Diode and Transistor Rectifiers

This paper presents a theoretical analysis of harmonically terminated high-efficiency power rectifiers and experimental validation on a class-C single Schottky-diode rectifier and a class-F-1 GaN transistor rectifier. The theory is based on a Fourier analysis of current and voltage waveforms, which arise across the rectifying element when different harmonic terminations are presented at its terminals. An analogy to harmonically terminated power amplifier (PA) theory is discussed. From the analysis, one can obtain an optimal value for the dc load given the RF circuit design. An upper limit on rectifier efficiency is derived for each case as a function of the device on-resistance. Measured results from fundamental frequency source-pull measurement of a Schottky diode rectifier with short-circuit terminations at the second and third harmonics are presented. A maximal device rectification efficiency of 72.8% at 2.45 GHz matches the theoretical prediction. A 2.14-GHz GaN HEMT rectifier is designed based on a class-F-1 PA. The gate of the transistor is terminated in an optimal impedance for self-synchronous rectification. Measurements of conversion efficiency and output dc voltage for varying gate RF impedance, dc load, and gate bias are shown with varying input RF power at the drain. The rectifier demonstrates an efficiency of 85% for a 10-W input RF power at the transistor drain with a dc voltage of 30 V across a 98-Omega resistor.

Roberg, M↗

Application of Monte Carlo code SHIFT for MSBR dose rate calculations

This paper presents a study that applied the Monte Carlo code SHIFT to calculate the radiological environment within a detailed Molten Salt Breeder Reactor (MSBR) model. It represents one of the first applications of the SHIFT code in stand-alone simulations for non-light water reactors to help demonstrate the code's potential uses in the design, licensing, and operation of advanced reactors. The radiological conditions of the MSBR were modeled when the reactor is at two different operation modes: normal full power and a drained state. The Forward Weighted-Consistent Adjoint Driven Importance Sampling (FW-CADIS) hybrid method in SHIFT was applied successfully to calculate the ex-core neutron and gamma dose rates for the MSBR at full power. Neutron and gamma dose rates within the drain cell were also calculated for the MSBR at the drained state by integrating the source terms obtained from an ORIGEN-S depletion calculation into the SHIFT simulation. The results indicate that in the drained state, the delayed gammas from the depleted fuel salt are the main contributors to the dose rates. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of Negative-Bias-Temperature-Instability on Low-Frequency Noise in SiGe ${p}$ MOSFETs

In this paper, we have measured the low-frequency 1/f noise of Si 0.55 Ge 0.45 pMOSFETs with a Si capping layer and SiO 2 /HfO 2 /TiN gate stack as a function of frequency, gate voltage, and temperature (100-440 K). The magnitude of the excess drain voltage noise power spectral density (Svd) is unaffected by negative-bias-temperature stress (NBTS) for temperatures below ~250 K, but increases significantly at higher temperatures. The noise is described well by the Dutta-Horn model before and after NBTS. The noise at higher measuring temperatures is attributed primarily to oxygen-vacancy and hydrogen-related defects in the SiO 2 and HfO 2 layers. Finally, at lower measuring temperatures, the noise also appears to be affected strongly by hydrogen-dopant interactions in the SiGe layer of the device.

1/f noise↗

Random telegraph signals by alkanethiol-protected Au nanoparticles in chemically assembled single-electron transistors

We have studied random telegraph signals (RTSs) in a chemically assembled single-electron transistor (SET) at temperatures as low as 300 mK. The RTSs in the chemically assembled SET were investigated by measuring the source–drain current, using a histogram of the RTS dwell time, and calculating the power spectrum density of the drain current–time characteristics. It was found that the dwell time of the RTS was dependent on the drain voltage of the SET, but was independent of the gate voltage. Considering the spatial structure of the chemically assembled SET, the origin of the RTS is attributed to the trapped charges on an alkanethiol-protected Au nanoparticle positioned near the SET. These results are important as they will help to realize stable chemically assembled SETs in practical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear transport in ionic liquid gated strontium titanate nanowires

Measurements of the current-voltage (I–V) characteristics of ionic liquid gated nanometer scale channels of strontium titanate have been carried out. At low gate voltages, the I–V characteristics exhibit a large voltage threshold for conduction and a nonlinear power law behavior at all temperatures measured. The source-drain current of these nanowires scales as a power law of the difference between the source-drain voltage and the threshold voltage. The scaling behavior of the I–V characteristic is reminiscent of collective electronic transport through an array of quantum dots. At large gate voltages, the narrow channel acts as a quasi-1D wire whose conductance follows Landauer's formula for multichannel transport.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Intrinsic Photoconductivity of few-layered ZrS 2 Phototransistors via Multiterminal Measurements

We report intrinsic photoconductivity studies on one of the least examined layered compounds, ZrS 2 .Few-atomic layer ZrS 2 field-effect transistors were fabricated on the Si/SiO 2 substrate and photoconductivity measurements were performed using both two- and four-terminal configurations under the illumination of 532 nm laser source. We measured photocurrent as a function of the incident optical power at several source-drain (bias) voltages. We observe a significantly large photoconductivity when measured in the multiterminal (four-terminal) configuration compared to that in the two-terminal configuration. For an incident optical power of 90 nW, the estimated photosensitivity and the external quantum efficiency (EQE) measured in two-terminal configuration are 0.5 A/W and 120%, respectively, under a bias voltage of 650 mV. Under the same conditions, the four-terminal measurements result in much higher values for both the photoresponsivity (R) and EQE to 6 A/W and 1400%, respectively. This significant improvement in photoresponsivity and EQE in the four-terminal configuration may have been influenced by the reduction of contact resistance at the metal-semiconductor interface, which greatly impacts the carrier mobility of low conducting materials. This suggests that photoconductivity measurements performed through the two-terminal configuration in previous studies on ZrS 2 and other 2D materials have severely underestimated the true intrinsic properties of transition metal dichalcogenides and their remarkable potential for optoelectronic applications.

36 MATERIALS SCIENCE↗

Realizing one-dimensional quantum and high-frequency transport features in aligned single-walled carbon nanotube ropes

The superiority of the electronic transport properties of single-walled carbon nanotube (SWNT) ropes over SWNT mats is verified from low temperature and frequency-dependent transport. The overall change of resistance versus in nanotube mats shows that 3D variable range hopping is the dominant conduction mechanism within the 2–300 K range. The magneto-resistance (MR) is found to be predominantly negative with a parabolic nature, which can also be described by the hopping model. Although the positive upturn of the MR at low temperatures establishes the contribution from quantum interference, the inherent quantum transport in individual tubes is suppressed at elevated temperatures. Therefore, to minimize multi-channel effects from inter-tube interactions and other defects, two-terminal devices were fabricated from aligned SWNT (extracted from a mat) for low temperature transport as well as high-frequency measurements. In contrast to the mat, the aligned ropes exhibit step-like features in the differential conductance within the 80–300 K temperature range. The effects of plasmon propagation, unique to one dimension, were identified in electronic transport as a non-universal power-law dependence of the differential conductance on temperature and source-drain voltage. The complex impedance showed high power transmission capabilities up to 65 GHz as well as oscillations in the frequency range up to 30 GHz. The measurements suggest that aligned SWNT ropes have a realistic potential for high-speed device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Subdrain Water Treatment Facility for Reduction of Waste Water Amount at the Fukushima NPS Site - 19318

At the Fukushima Daiichi Nuclear Power Station site, a water treatment facility dedicated to the subdrain and groundwater drain has been constructed by Tokyo Electric Power Company Holdings, Inc. and Hitachi-GE Nuclear Energy, Ltd. The facility consists of three kinds of equipment for collecting, purifying and transferring contaminated water. The purification equipment removes low concentration radionuclides, such as Cs-137 and Sr-90, contained in the pumped groundwater using adsorption vessels filled with Cs-Sr adsorbent. It is important to lower the operational cost of the facility. We have been developing a cost reduction technique to prolong the operating lifetime of the Cs-Sr adsorption vessels by improving the adsorption performance of the Cs-Sr simultaneous adsorbent. Therefore, pH adjustment for the groundwater by using granular MgO as a pH adjustment agent was investigated. The experimental and the simulation results showed that the distribution coefficient Kd with pH adjustment by MgO was evaluated as approximately 1.8 times higher than Kd without pH adjustment and the replacement timing of the Cs-Sr adsorption vessels with pH adjustment was 2 times longer than the timing without pH adjustment. From these results, we decided to include pH adjustment using MgO as the pH adjustment agent in the purification equipment in order to reduce the amount of Cs-Sr simultaneous adsorbent used and the operational cost of the facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coalescence kinetics in surfactant stabilized emulsions: Evolution equations from direct numerical simulations

Lattice Boltzmann simulations were used to study the coalescence kinetics in emulsions with amphiphilic surfactant, under neutrally buoyant conditions, and with a significant kinematic viscosity contrast between the phases (emulating water in oil emulsions). The 3D simulation domain was large enough (256 3rd power -- 10 7th power grid points) to obtain good statistics with droplet numbers ranging from a few thousand at early times to a few hundred near equilibrium. Increased surfactant contents slowed down the coalescence rate between droplets due to the Gibbs-Marangoni effect, and the coalescence was driven by a quasi-turbulent velocity field. The kinetic energy decayed at a relatively slow rate at early times, due to conversion of interfacial energy to kinetic energy in the flow during coalescence. Phenomenological, coupled differential equations for the mean droplet diameter D(t) and the number density nd(t) were obtained from the simulation data and from film draining theories. Local (in time) power law exponents for the growth of the mean diameter (and for the concomitant decrease of nd) were established in terms of the instantaneous values of the kinetic energy, coalescence probability, Gibbs elasticity, and interfacial area. The model studies indicated that true power laws for the growth of the droplet size and decrease of the number of droplets with time may not be justified, since the exponents derived using the phenomenological model were time dependent. In contrast to earlier simulation results for symmetric blends with surfactant, we found no evidence for stretched logarithmic scaling of the formD -- [ln (ct)]a for the morphology length, or exponential scalings associated with arrested growth, on the basis of the phenomenological model.

58 GEOSCIENCES↗

Sub-drain Water Treatment Facility for Reduction of Accumulated Waste Water Amount at the Fukushima NPS Site - 17572

At the Fukushima Daiichi Nuclear Power Station site, water treatment facility special for sub-drain and groundwater drain has been constructed by Tokyo Electric Power Company Holdings, Inc. and Hitachi-GE Nuclear Energy, Ltd., and it has been operated to remove radionuclides from the pumped groundwater. The facility consists of three kinds of equipment for collecting, purifying and transferring. The purification equipment removes radionuclides contained in the pumped groundwater. The purification equipment consists of filters for removal of solids and colloidal particles, and adsorbents for removal of ionic radionuclides. Five adsorption vessels are installed into the equipment; three vessels have adsorbent to remove Cs and Sr simultaneously, the fourth vessel has adsorbent to remove Sb and for the last has adsorbent to remove heavy metals. The vessels for Cs and Sr are operating as a so-called 'merry-go-round'. For the rational operation of the equipment, a simulation code has been developed to calculate the Sr concentration of outlet water which determines the replacement timings of the Cs-Sr adsorption vessels. The simulation code has been applied to planning of vessel replacement during the water treatment facility operation. The facility started operation in September 2015, and treated the pumped groundwater since then. As of October 2016, about 211,000 m{sup 3} of groundwater had been treated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Semiconductor power device including wire or ribbon bonds over device active region

A semiconductor power device including a base plate; an input lead; an output lead; a field effect transistor (FET) power die disposed over the base plate, wherein the FET power die includes a set of source fingers, a set of drain fingers, and a set of gate fingers disposed directly over an active region, wherein the gate fingers are configured to receive an input signal from the input lead, and wherein the FET power die is configured to process the input signal to generate an output signal at the drain fingers for routing to the output lead; and electrical conductors (wirebonds or ribbons) bonded to the source and/or drain directly over the active region of the FET power die. The electrical conductors produce additional thermal paths between the active region and the base plate for thermal management of the FET power die.

42 ENGINEERING↗

FY23 Report on Water NSTF Testing at Two-Phase Conditions: Off-normal Scenarios

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report details the experimental activities and upgrades performed during the program’s fifth year of water-based operation. The theme of this year of testing was examining off-normal scenarios. In practice, that meant examining scenarios with blockages or other design basis conditions. From a maintenance and capability standpoint that meant assessing valving options for implementing blockages, assessing drain and refill capabilities, and ensuring in all cases that operators could safely, efficiently, and repeatably bring the facility to an off-normal condition and return it to the normal operating state. In one notable case, no solution existed, nor was a solution commercially available, that met the facility needs for implementing blockages within the two-phase region of the chimney. A valve and feedthrough were custom-designed for NSTF to operate submerged in saturated water while being safely actuated from outside the tank. The fifth year of testing included eight matrix tests consisting of 162 hours of active heating, 9,735 kWh of electrical heating, with seven tests classified as Accepted per NQA-1 and one as Trending. All matrix tests were performed at two-phase flow conditions. The power parametric series from previous years was extended to include another scenario with a decay load equivalent to 1.75 MWt, full scale, further resolving the system flow oscillation response as a function of input power. A depletion test was performed to extend previous work and examine the system’s approach to stagnation and geysering that were not previously observed. This test began at an initial inventory level of 50%, prototypic power of 2.1 MWt, and employed an accelerated drain of 0.75 gpm plus boiloff until stagnation conditions were achieved and multiple geysering events were recorded. Further exploring the geysering phenomenon was a separate effects test examining static boiling in the risers and chimney. This static boiling test was performed at 48 kWe, a higher power than testing in the previous year, and included enhancements to the drain system to remove inventory in a better-controlled and more reliable manner. Two tests were performed, at prototypic conditions of 1.4 MWt and 2.4 MWt, respectively, examining the system response to throttled conditions in the singlephase region of the piping. A ball valve immediately before he riser inlet header was increasingly throttled, progressing the system through a repeatable pattern of two-phase oscillations and stable regimes before ultimately inducing stagnation and geysering. Concluding the year, two tests were performed at baseline conditions of 70% initial inventory level and 2.1 MWt of prototypic decay heat to examine both repeatability and the response to throttling within the two-phase region, at the inventory tank inlet using the custom valve mentioned above. The first such test repeated transient operating conditions and revealed significant sensitivity t

22 GENERAL STUDIES OF NUCLEAR REACTORS↗