Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DR POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Data Repository for Power system Open models With Evolving Resources (DR POWER) (Final Scientific/Technical Report)

Pacific Northwest National Laboratory (PNNL) and the National Rural Electric Cooperative Association (NRECA) created a Data Repository for Power system Open models With Evolving Resources (DR POWER) to establish, curate, and evolve open-access power grid models and scenarios, and measurements and observations, collectively referred to as datasets. Existing open-access datasets are inadequate (too small and not representative of the complexity of the modern grid, and scattered all over the world wide web) for the investigation and benchmarking of the advanced optimization methods needed for next-generation grids. Open-access datasets are static and inadequate in other aspects: they do not provide format transformation tools; there is missing information needed for advanced applications; hard to cite; no model evolution history; difficult to update current collections; and little to no community involvement and feedback. Overall, the current landscape is hindering model evolution and benchmarking standards needed for transformational approaches to be developed, tested, and accepted by the power modeling community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stochastic Pricing Game for Aggregated Demand Response Considering Comfort Level

In recent years, demand response (DR) has been explored as a fundamental strategy for demand-side management due to its advantages in mediating intermittency of renewable energy generation, load shifting, etc. To engage customers in DR programs, several deterministic price-based DR strategies have been developed and implemented. However, the stochastic weather conditions and occupants' consumption behaviors often make the deterministic solution less robust to uncertainties. In this paper, with the consideration of the uncertainties, a stochastic Stackelberg game is proposed to model the price-demand negotiation between a distributed system operator and load aggregators, where the virtual battery constraints are extracted from the building thermostatically controlled loads (TCLs)‘ characteristics to guarantee comfortable TCLs' levels. Following the negotiation, a priority-based control method is used to allocate the optimal aggregated power DR profile at the building level and track the power signal. Several groups of experiments have demonstrated the effectiveness and robustness of the stochastic solutions.

Chen, Yang↗

Demand Response Potential from the Bulk Grid Perspective

Gain insight from an exploration of the potential value of demand response (DR) in future power systems. Using hourly DR resource estimates by sub-sector, electrical end-use, and grid service, we incorporate virtual generator models of DR resources into large-scale production cost models, and analyze the grid-level impacts in terms of the ability of DR to reduce system costs and potentially help integrate renewables or reduce system emissions. Additionally, we examine the value of DR, its revenue, and how these change under different system conditions. In this panel session, we will describe our input data and modeling methods, provide an overview of the production cost models used, and summarize key results from analyses in Florida and the western United States. Findings include variations in DR value by end-use and geography, an ability to increase economic PV deployment potential in high penetration systems, and mixed emissions outcomes depending on system composition and fuel prices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

High Effectiveness, Compact, High Pressure and Low-Cost Recuperator, Presented at The Fifth International Symposium – Super-Critical CO2 Power Cycles, San Antonio, Texas, March 28-31, 2016, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

High Effectiveness, Compact, High Pressure and Low Cost Recuperator for Super-Critical CO2 Power Cycles, Paper Presented at The Fifth International Symposium – Super-Critical CO2 Power Cycles, San Antonio, Texas, March 28-31, 2016, by Dr. John Kelly, President, Altex Technologies Corporation

Closed Brayton super-critical CO2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m3/UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO2. Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $1,500/UA. In addition, the 5,083 kW unit HELC cost of $61.09/kW is 33.6% lower than the $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

Optimal Control of SOEC-Based Hydrogen Production Systems for Demand Response Using Deep Reinforcement Learning in Smart Grids

Solid oxide electrolysis cell (SOEC) hydrogen production technology can range in size from small, appliance-size equipment to large-scale, central production facilities that can be tied directly to renewable or non-greenhouse-gas-emitting forms of electricity production, making it an ideal resource for demand response (DR). The SOEC hydrogen production system is a complex integrated system that encompasses fluid dynamics, electrical dynamics, and electrochemical and thermal dynamics, all of which involve non-linearity and non-convexity. Proper control of the SOEC hydrogen production system is crucial to enable its participation in the DR program. Here, to overcome the difficulty of designing an explicit control law for such nonlinear systems with nonconvex optimization features in DR applications, deep reinforcement learning (DRL) is explored to achieve the optimal control of the SOEC system for DR participation. Specifically, a twin delayed deterministic policy gradient (TD3) control framework is applied to achieve optimal response performance during DR events by considering power tracking error and hydrogen production efficiency with a suitable reward function. Two case studies with grid connections for tracking different DR commands were investigated. The first case study involved operating conditions reaching the boundaries, while the second involved operating conditions within the boundaries. The results showed that the proposed DRL-based control for SOEC can track the DR signal in a timely manner while maintaining high energy efficiency.

08 HYDROGEN↗

The scaling of complex craters

The empirical relation between the transient crater diameter (Dg) and final crater diameter (Dr) of complex craters and basins is estimated using cumulative terrace widths, central uplift diameters, continuous ejecta radii, and transient crater reconstructions determined from lunar and terrestrial impact structures. The ratio Dg/Dr is a power law function of Dr, decreasing uniformly from unity at the diameter of the simple-complex crater morphology transition to about 0.5 for large multiring basins like Imbrium on the moon. The empirical constants in the Dg/Dr relation are interpreted physically to mean that the position of the final rim relative to the transient crater, and hence the extent of collapse, is controlled or greatly influenced by the properties of the zone of dissociated material produced by the impact shock. The continuity of the Dg/Dr relation over the entire spectrum of morphologic types from complex craters to multiring basins implies that the rims of all these structures form in the same tectonic environment despite morphologic differences.

Croft, S. K.↗

Assessing the Interactive Impacts of Energy Efficiency and Demand Response on Power System Costs and Emissions

Utilities are increasingly interested in integrating energy efficiency (EE) and demand response (DR) measures and technologies (as well as other distributed energy resources) as a strategic approach to improve their cost-effectiveness and performance. However, the specific EE and DR features that may be best integrated, the interplay between changing EE and DR resource potential, and resulting utility system impacts are not well understood. We quantify the impacts of EE and DR in isolation and in combination on bulk power system costs and emissions based on changes in generation expansion, transmission expansion, and dispatch patterns. The study methodology mimics utility resource planning and uses more novel techniques to select least-cost generation and transmission capacity from supply-and demand-side resources, as compared to more commonly used utility approaches that only consider supply-side resources. The results identify key EE and DR characteristics affecting each other’s power system value and the most valuable technologies and strategies that can be jointly deployed. We discuss implications for EE and DR cost-effectiveness frameworks, program design, and integrated resource planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Far-infrared and radio observations of DR 6, DR 7, and DR 22

Far-infrared maps are presented for three young H II regions in the Cygnus X region. DR 6 and 7 were mapped in the wavelength band from 40 to 250 microns at 1 arcmin resolution, while DR 22 was mapped in the same band and also at 100-250 microns, providing dust temperature and optical depth information. New VLA maps of these sources are also presented. It is concluded that DR 6 and 7 are powered by clusters of late O or early B type stars, with ages 100,000 yr or less, while DR 22 appears to be produced by a single O6 ZAMS star. Existing (C-12)O maps suggest that the formation of these objects occurred near the edges of molecular clouds.

Odenwald, S.↗

An empirical study of moving horizon closed-loop demand response scheduling

The potential of electricity-intensive chemical plants to engage in demand response (DR) initiatives in support of power grid operations has been the subject of many conceptual studies. In this work, using an industrially-relevant model of an air separation unit, we undertake an extensive simulation study of moving horizon (MH) rescheduling approaches, where we "close the scheduling loop" based on updated information regarding disturbances such as changes in electricity prices, ambient conditions and chemical product demand. Our study produces several unexpected findings regarding the non-periodic nature of rescheduling solutions, the impact of the accuracy of disturbance forecasts on the economics of DR scheduling, and on the interplay of simultaneously dealing with fluctuations on both the supply side (i.e., electricity prices) and the product demand side of the plant. Furthermore, we posit that the latter fluctuations pose significant limitations to the potential of a chemical plant to engage in DR.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A data-driven linear formulation of the optimal demand response scheduling problem for an industrial air separation unit

Demand response (DR) has become a key element in balancing the power grid as the contribution of time-varying renewable power generation increases. Chemical plants are appealing candidates for DR programs as they offer large, concentrated and flexible loads. DR participation calls for frequent production rate changes over time scales that overlap with the dominant dynamics of the plant. Production scheduling should therefore consider the process dynamics explicitly. Here we present a data-driven approach for modelling the scheduling-relevant dynamics based on historical closed-loop operating data using autoregressive with extra inputs (ARX) models. We introduce a new, linear scheduling problem formulation based on the ARX representation, and demonstrate its implementation on an industrial air separation unit.

42 ENGINEERING↗

Investigation of a Hybrid Carbon Capture System at a NGCC Power Plant That Performs Direct Air Capture During Off-Peak Hours

The goal of this project was to investigate the feasibility of coupling NGCC power plants with membrane and solid sorbent carbon capture to achieve net negative carbon emissions. This novel hybrid system has a couple of potential benefits: 1) the carbon capture systems could help the NGCC plant by minimizing its carbon footprint and giving it a new revenue stream from direct air capture, and 2) the NGCC plant could help direct air capture scale up quickly and costeffectively by providing it with electricity, steam and compressed air streams. In order to investigate this hybrid design, we developed a complex, integrated system model consisting of: 1) a NGCC power plant model developed by Dr. Bhattacharyya’s team at WVU, 2) a membrane carbon capture model developed by Dr. Lipscomb’s team at U Toledo, and 3) a solid sorbent carbon capture model developed by Dr. Hornbostel’s team at U Pittsburgh. Mr. Matuszewski’s team at AristoSys LLC integrated these three models into a single, integrated model using FOQUS, an optimization tool developed by the NETL CCSI 2 program. Optimizations were then performed on this integrated model to determine the cost and carbon capture rates under a range of electricity and carbon price scenarios.

20 FOSSIL-FUELED POWER PLANTS↗

Light Visor

Seasonal Affective Disorder is a form of depression brought on by reduced light. For some people, this can lead to clinical depression. NASA has conducted research in light therapy and employs it to help astronauts adjust internal rhythms during orbital flight. Dr. George Brainard, a medical researcher and NASA consultant, has developed a portable light therapy device, which is commercially available. The Light Visor allows continuous light therapy and can be powered by either batteries or electricity. Dr. Brainard continues to research various aspects of light therapy.

Source record↗