Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSE LIMITS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

EVALUATION OF EXISTING PUBLIC DOSE LIMITS APPLIED TO RECREATIONAL SPACEFLIGHT

Abstract Establishing realistic radiation dose limits with a solid scientific basis is a key component of the ‘as low as reasonably achievable’ (ALARA) principle. Although existing occupational dose limits have been established for civil astronauts, with the rise in popularity and technological maturation of the ‘space tourism’ sector, there does not appear to be considerable discussion on the subject of non-occupational astronaut dose limits. The necessity to come to a collective decision on dose limits and radiation safety procedures for recreational spaceflight is urgent and imperative to maintain ALARA goals, as existing federal dose limits to the public cannot be adequately or universally applied to the space tourism sector. Development of an entirely new set of regulations and guidelines should also provide long-term benefits in public perception as evidence of safety commitments from decision makers and the community in protecting passengers from radiological risks balanced with other spaceflight hazards.

Long, Michael A. (ORCID:0000000181363476)↗

Applicability of Public Dose Limits to Individuals on the Nevada National Security Site

Historically all persons working on the Nevada National Security Site (NNSS) were considered subject to worker dose limits when calculations of potential dose from the air pathway were conducted to demonstrate compliance with Title 42 United States Code (USC) Chapter 85, “The Clean Air Act,” and Title 40 Code of Federal Regulations (CFR) Part 61, Subpart H, “National Emission Standards for Hazardous Air Pollutants (NESHAP).” Calculations were also conducted for the all-pathways potential dose to demonstrate compliance with U.S. Department of Energy (DOE) Order DOE O 458.1 Chg. 3, “Radiation Protection of the Public and the Environment.” The need to evaluate environmental air sampling locations and past regulator questions about the existence of persons potentially subject to public dose limits being on the NNSS drove this assessment (letter from EPA [U.S. Environmental Protection Agency] Region 9 to DOE/Nevada Operations Office, dated September 3, 1999). This assessment also supports determining those persons subject to public dose limits from the all pathways perspective. A person that is a member of the public is subject to public dose limits.

61 RADIATION PROTECTION AND DOSIMETRY↗

Decreasing Irradiated Rat Lung Volume Changes Dose-Limiting Toxicity From Early to Late Effects

Purpose: Technological developments in radiation therapy result in smaller irradiated volumes of normal tissue. Because the risk of radiation therapy-induced toxicity generally depends on irradiated volume, changing volume could change the dose-limiting toxicity of a treatment. Recently, in our rat model, we found that early radiation-induced lung dysfunction (RILD) was closely related to irradiated volume dependent vascular remodeling besides inflammation. The exact relationship between early and late RILD is still unknown. Therefore, in this preclinical study we investigated the dose-volume relationship of late RILD, assessed its dependence on early and late pathologies and studied if decreasing irradiated volume changed the dose-limiting toxicity. Methods and Materials: A volume of 25%, 32%, 50%, 63%, 88%, or 100% of the rat lung was irradiated using protons. Until 26 weeks after irradiation, respiratory rates were measured. Macrovascular remodeling, pulmonary inflammation, and fibrosis were assessed at 26 weeks after irradiation. For all endpoints dose-volume response curves were made. These results were compared to our previously published early lung effects. Results: Early vascular remodeling and inflammation correlated significantly with early RILD. Late RILD correlated with inflammation and fibrosis, but not with vascular remodeling. In contrast to the early effects, late vascular remodeling, inflammation and fibrosis showed a primarily dose but not volume dependence. Comparison of respiratory rate increases early and late after irradiation for the different dose-distributions indicated that with decreasing irradiated volumes, the dose-limiting toxicity changed from early to late RILD. Conclusions: In our rat model, different pathologies underlie early and late RILD with different dose-volume dependencies. Consequently, the dose-limiting toxicity changed from early to late dysfunction when the irradiated volume was reduced. In patients, early and late RILD are also due to different pathologies. As such, new radiation techniques reducing irradiated volume might change the dose-limiting toxicity of the radiation therapy treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Finding Uncertainties that Cause the Age Dependence of Dose Limits to Be Immature

Space radiation permissible exposure limits (PEL) are intended to set acceptable levels of cancer risks, and avoid any clinical significant non-cancer effects. The 1989 recommendation of the National Council of Radiation Protection and Measurements (NCRP) recommended a strong age dependence of dose limits that departed drastically from the then mature 1970 dose limits recommendations from the National Academy of Science, which were independent of age. In 2000, the NCRP recommended revised limits that showed a similar trend of risk with age to the 1989 report. In this model, the cancer risk per Sv varies by more than 2-fold for ages between 30- and 50-yr. Therefore for galactic cosmic rays exposure, astronaut age has a larger influence on risk then radiation shielding mass or material composition, vehicle propulsion method, or position in the solar cycle. For considering the control of mission costs and resources, the possibility of using astronaut age as a trade variable in mission design could be considered. However, the uncertainties in describing the age dependence on risk have not been fully explored. We discuss biological factors that influence the age dependence of radiation risks, including susceptibility, expression and latency, and radiation quality. These factors depend not only on the individual s age, but also their genetic sensitivity and interaction with other environmental factors. Epidemiological data is limited in describing the age dependence on risk. The 2005, BEIR VII report recommends an age dependence for cancer risk attributable solely to the life-table disagreeing strongly with the NCRP model. However, BEIR VII also noted the limited power of human data for concomitantly describing both age and age after exposure dependences of cancer risks. Many experimental studies have shown that high LET radiation (e.g., high charge and energy (HZE) nuclei and neutrons) display reduced latency compared to low LET radiation, suggesting distinct biological factors are important. We discuss potential molecular mechanisms that would influence the age dependence of radiation risks. A probability distribution function for the uncertainties in age-dependence of risk models is described and predictions for Mars missions discussed. Our report suggests that theoretical considerations based on new experimental studies are needed to ensure the correct age dependence in space radiation risk models and the resulting Astronaut PEL.

Cucinotta, Francis A.↗

Dose-limiting Urinary Toxicity With Pembrolizumab Combined With Weekly Hypofractionated Radiation Therapy in Bladder Cancer

There is currently significant interest in the potential benefits of combining radiation and immune checkpoint blockade (ICB) to stimulate both regional and distant abscopal immune responses. In melanoma and lung cancer, patients who have received radiation therapy during ICB appear to have prolonged survival. The PLUMMB trial (Pembrolizumab in Muscle-invasive/Metastatic Bladder cancer) (NCT02560636) is a phase I study to test the tolerability of a combination of weekly radiation therapy with pembrolizumab in patients with metastatic or locally advanced urothelial cancer of the bladder. In the first dose-cohort, patients received pembrolizumab 100 mg 3-weekly, starting 2 weeks before commencing weekly adaptive bladder radiation therapy to a dose of 36 Gy in 6 fractions. The first dose-cohort was stopped after 5 patients, having met the predefined definition of dose-limiting toxicity. Three patients experienced grade 3 urinary toxicities, 2 of which were attributable to therapy. One patient experienced a grade 4 rectal perforation. In view of these findings, the trial has been paused and the protocol will be amended to reduce radiation therapy dose per fraction. The authors advise caution to those combining radiation therapy and ICB, particularly when radiation therapy is given at high dose per fraction for pelvic tumours. The PLUMMB trial met the protocol-defined definition of dose-limiting toxicity and will be amended to reduce radiation therapy dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimating the Effects of Astronaut Career Ionizing Radiation Dose Limits on Manned Interplanetary Flight Programs

Space radiation effects mitigation has been identified as one of the highest priority technology development areas for human space flight in the NASA Strategic Space Technology Investment Plan (Dec. 2012). In this paper we review the special features of space radiation that lead to severe constraints on long-term (more than 180 days) human flight operations outside Earth's magnetosphere. We then quantify the impacts of human space radiation dose limits on spacecraft engineering design and development, flight program architecture, as well as flight program schedule and cost. A new Deep Space Habitat (DSH) concept, the hybrid inflatable habitat, is presented and shown to enable a flexible, affordable approach to long term manned interplanetary flight today.

Koontz, Steven L.↗

Estimating the Effects of Astronaut Career Ionizing Radiation Dose Limits on Manned Interplanetary Flight Programs

The Hybrid Inflatable DSH combined with electric propulsion and high power solar-electric power systems offer a near TRL-now solution to the space radiation crew dose problem that is an inevitable aspect of long term manned interplanetary flight. Spreading program development and launch costs over several years can lead to a spending plan that fits with NASA's current and future budgetary limitations, enabling early manned interplanetary operations with space radiation dose control, in the near future while biomedical research, nuclear electric propulsion and active shielding research and development proceed in parallel. Furthermore, future work should encompass laboratory validation of HZETRN calculations, as previous laboratory investigations have not considered large shielding thicknesses and the calculations presented at these thicknesses are currently performed via extrapolation.

Koontz, Steven L.↗

Ultra-low-dose limited renal CT for volumetric stone surveillance: advantages over standard unenhanced CT

Purpose: To describe and validate a novel CT approach using volumetric analysis for renal stone surveillance. Materials and methods: This prospective trial consisted of a standard low-dose non-contrast CT (SLD) of the abdomen and pelvis, immediately followed by an ultra-low-dose non-contrast CT (ULD) with reconstruction limited to the kidneys. A novel dedicated software tool was applied that automates stone volume, density, and maximum linear size. Manual linear stone size was measured by a radiology fellow and urology resident for comparison. CT dose and clinical charges were considered. Results: Twenty-eight stones in 16 patients were analyzed. Mean effective dose of ULD CT was 0.57 mSv, an average 92% lower than the SLD CT dose. For SLD, mean size ± SD (range) (mm) was 7.9 ± 6.2 (2.6–30.5) for Reader 1, 7.3 ± 6 (2.4–30.7) for Reader 2, and 9.3 ± 6.4 (3.7–33.1) for the automated software. For ULD, mean size ± SD (range) (mm) was 7.3 ± 6 (2.5–30.5) for Reader 1, 7.2 ± 6.1 (2.1–30.7) for Reader 2, and 9.1 ± 6.4 (4.2–32.8) for the automated software. Automated stone diameters were larger than manual diameters for 27/28 stones (mean difference, 23%); difference was ≥ 2 mm in 30%. Average variability between manual measurements was 8.6% (SLD) and 7.8% (ULD), but was 0% for the automated technique. Our institutional charge for ULD renal CT is slightly less than renal US, and > 4× less than SLD CT. The Medicare global fee for the ULD renal CT is less than the SLD CT of the abdomen and pelvis. Conclusions: This focused stone surveillance CT protocol is lower cost and lower dose compared to the standard CT approach. Automated assessment of stone burden provides improved reproducibility over manual linear measurement and offers the advantages of 3D measurements and volumetry. We now offer and perform this protocol in routine clinical practice for stone surveillance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation damage and dose limits in serial synchrotron crystallography at cryo- and room temperatures

Radiation damage limits the accuracy of macromolecular structures in X-ray crystallography. Cryogenic (cryo-) cooling reduces the global radiation damage rate and, therefore, became the method of choice over the past decades. The recent advent of serial crystallography, which spreads the absorbed energy over many crystals, thereby reducing damage, has rendered room temperature (RT) data collection more practical and also extendable to microcrystals, both enabling and requiring the study of specific and global radiation damage at RT. Here, we performed sequential serial raster-scanning crystallography using a microfocused synchrotron beam that allowed for the collection of two series of 40 and 90 full datasets at 2- and 1.9-Å resolution at a dose rate of 40.3 MGy/s on hen egg white lysozyme (HEWL) crystals at RT and cryotemperature, respectively. The diffraction intensity halved its initial value at average doses ( D 1/2 ) of 0.57 and 15.3 MGy at RT and 100 K, respectively. Specific radiation damage at RT was observed at disulfide bonds but not at acidic residues, increasing and then apparently reversing, a peculiar behavior that can be modeled by accounting for differential diffraction intensity decay due to the nonuniform illumination by the X-ray beam. Specific damage to disulfide bonds is evident early on at RT and proceeds at a fivefold higher rate than global damage. The decay modeling suggests it is advisable not to exceed a dose of 0.38 MGy per dataset in static and time-resolved synchrotron crystallography experiments at RT. This rough yardstick might change for proteins other than HEWL and at resolutions other than 2 Å.

36 MATERIALS SCIENCE↗

Dose limits for astronauts

Radiation exposures to individuals in space can greatly exceed natural radiation exposure on Earth and possibly normal occupational radiation exposures as well. Consequently, procedures limiting exposures would be necessary. Limitations were proposed by the Radiobiological Advisory Panel of the National Academy of Sciences/National Research Council in 1970. This panel recommended short-term limits to avoid deterministic effects and a single career limit (of 4 Sv) based on a doubling of the cancer risk in men aged 35 to 55. Later, when risk estimates for cancer had increased and were recognized to be age and sex dependent, the NCRP, in Report No. 98 in 1989, recommended a range of career limits based on age and sex from 1 to 4 Sv. NCRP is again in the process of revising recommendations for astronaut exposure, partly because risk estimates have increased further and partly to recognize trends in limiting radiation exposure occupationally on the ground. The result of these considerations is likely to be similar short-term limits for deterministic effects but modified career limits.

Review↗

User Guide for GoldSim Model to Calculate PA/CA Doses and Limits

A model to calculate doses for solid waste disposal at the Savannah River Site (SRS) and corresponding disposal limits has been developed using the GoldSim commercial software. The model implements the dose calculations documented in SRNL-STI-2015-00056, Rev. 0 “Dose Calculation Methodology and Data for Solid Waste Performance Assessment (PA) and Composite Analysis (CA) at the Savannah River Site”.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results. Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.

61 RADIATION PROTECTION AND DOSIMETRY↗

URC/HRC Selection Guidance

Given the importance of the URC and HRC thresholds as part of a physical security program that is designed to protect against radiological sabotage, it is important to provide guidance on how to assign those thresholds consistent with a State’s level of risk tolerance. Without such guidance, most States will be challenged to establish appropriate thresholds or appropriately establish regulations. This document provides guidance on establishing dose limits and where they apply, as well as the timeframe for which the dose limits should be measured. For dose limits, it offers examples of established thresholds based on safety and emergency response thresholds. Whereas, for timeframes, a process to identify possible timeframes is offered.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-G-201-11: Exploring the Upper Limits of Dose Sculpting Capacity of the Novel Direction Modulated Brachytherapy (DMBT) Tandem Applicator

Purpose: To explore and quantify the upper limits in dose sculpting capacity of the novel direction modulated brachytherapy (DMBT) tandem applicator compared with conventional tandem design for {sup 192}Ir-based HDR planning. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy (IGABT), especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles – leading to enhanced dose sculpting capacity through inverse planning. The external dimensions are identical to that of conventional tandem design to ensure clinical compatibility. To explore the expansive dose sculpting capacity, we constructed a hypothetical circular target with 20-mm radius and positioned the DMBT and conventional tandems at the center. We then incrementally shifted the positions laterally away from the center of up to 15 mm, at 1-mm steps. The in-house coded gradient projection-based inverse planning system was then used to generate inverse optimized plans ensuring identical V100=100% coverage. Conformity index (CI) was calculated for all plans. Results: Overall, the DMBT tandem generates more conformal dose distributions than conventional tandem for all lateral positional shifts of 0-15 mm (CI=0.91–0.52 and 0.99–0.34, respectively), with an exception at the central position due to the ideal circular dose distribution, generated by the {sup 192}Ir, fitting tightly around the circular target (CI = 0.91 and 0.99, respectively). The DMBT tandem is able to generate dose conformity of CI>0.8 at up to 6-mm positional shift while the conventional tandem violates this past 2-mm shift. Also, the CI ratio (=DMBT/conv.) increases rapidly until about 8 mm and then stabilizes beyond. Conclusion: A substantial enhancement in the dose sculpting capacity has been demonstrated for the novel DMBT tandem applicator. While further studies are warranted, the concept is promising for potential clinical translation.

60 APPLIED LIFE SCIENCES↗

Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

Long, Edward R., Jr.↗