Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Moving Beyond Mortality: Development and Application of a Desirability of Outcome Ranking (DOOR) Endpoint for Hospital-Acquired Bacterial Pneumonia and Ventilator-Associated Bacterial Pneumonia

Abstract Background Hospital-acquired and ventilator-associated bacterial pneumonia (HABP/VABP) are frequently caused by multidrug-resistant organisms. Patient-centered endpoints in clinical trials are needed to develop new antibiotics for HABP/VABP. Desirability of outcome ranking (DOOR) is a paradigm for the design, analysis, and interpretation of clinical trials based on a patient-centered, benefit-risk evaluation. Methods A multidisciplinary committee created an infectious diseases DOOR endpoint customized for HABP/VABP, incorporating infectious complications, serious adverse events, and mortality. We applied this to 2 previously completed, large randomized controlled trials for HABP/VABP. ZEPHyR compared vancomycin to linezolid and VITAL compared linezolid to tedizolid. For each trial, we evaluated the DOOR distribution and probability, including DOOR component and partial credit analyses. We also applied DOOR in subgroup analyses. Results In both trials, the HABP/VABP DOOR demonstrated similar overall clinical outcomes between treatment groups. In ZEPHyR, the probability that a participant treated with linezolid would have a more desirable outcome than a participant treated with vancomycin was 50.2% (95% confidence interval [CI], 45.1%­−55.3%). In VITAL, the probability that a participant treated with tedizolid would have a more desirable outcome than a participant treated with linezolid was 48.7% (95% CI, 44.8%–52.6%). The DOOR component analysis revealed that participants treated with tedizolid had a less desirable outcome than those treated with linezolid when considering clinical response alone. However, participants with decreased renal function had improved overall outcomes with tedizolid. Conclusions The HABP/VABP DOOR provided more granular information about clinical outcomes than is typically presented in clinical trials. HABP/VABP trials would benefit from prospectively using DOOR.

Immunology↗

Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system

Highlights: Black-Right-Pointing-Pointer We compare the environmental sustainability of two MSW collection systems. Black-Right-Pointing-Pointer We evaluate pneumatic and door-to-door collection systems. Black-Right-Pointing-Pointer The greenhouse gas emissions of pneumatic collection are around three times higher. Black-Right-Pointing-Pointer System components are decisive but assumptions on electricity use are also important. Black-Right-Pointing-Pointer Pneumatic collection could provide other benefits over door-to-door system. - Abstract: Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO{sub 2} and NO{sub x}. The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Refrigerator Door-in-Door Opening Controller

Door-in-door refrigerators are becoming increasingly popular on the market. To save energy, items that are most frequently used are stored between doors. Thus only the outer door needs to be opened for access. This invention is used for standard energy performance laboratory tests for these kinds of refrigerators. In conjunction with an automated refrigerator door opener, it allows the refrigerator door opener to open either the outer door only or both inner and outer doors together.

Wang, Duo↗

Solar Power Ramp Events Detection Using an Optimized Swinging Door Algorithm: Preprint

Solar power ramp events (SPREs) are those that significantly influence the integration of solar power on non-clear days and threaten the reliable and economic operation of power systems. Accurately extracting solar power ramps becomes more important with increasing levels of solar power penetrations in power systems. In this paper, we develop an optimized swinging door algorithm (OpSDA) to detection. First, the swinging door algorithm (SDA) is utilized to segregate measured solar power generation into consecutive segments in a piecewise linear fashion. Then we use a dynamic programming approach to combine adjacent segments into significant ramps when the decision thresholds are met. In addition, the expected SPREs occurring in clear-sky solar power conditions are removed. Measured solar power data from Tucson Electric Power is used to assess the performance of the proposed methodology. OpSDA is compared to two other ramp detection methods: the SDA and the L1-Ramp Detect with Sliding Window (L1-SW) method. The statistical results show the validity and effectiveness of the proposed method. OpSDA can significantly improve the performance of the SDA, and it can perform as well as or better than L1-SW with substantially less computation time.

14 SOLAR ENERGY↗

The Solar Influencer Next Door: Predicting Low-Income Solar Referrals and Leads

Increasing the adoption of solar among low-to-moderate income (LMI) households remains an important policy goal because of its promise to simultaneously reduce energy burden and support the just distribution of benefits of renewable energy. However, scaling LMI solar remains challenging due to affordability and access issues. Most existing LMI adoption has occurred under public-funded programs, highlighting the importance of increasing the cost-effectiveness of these programs at scale. We develop a new household-level data set on LMI solar lead acquisition, referrals, and adoption to understand the processes through which LMI solar uptake has occurred in California. Then, we develop models to predict two sub-mechanisms in the solar adoption process: whether an otherwise qualified lead becomes "lost" i.e. non-responsive to outreach and, for existing clients, whether they refer solar to others. For the program analyzed, participants received their solar system at no cost, which deemphasizes economic drivers of solar adoption and could differ from other program experiences. Both models substantially improved the accuracy of prediction relative to a baseline. Overall, we find that peer effects and solar economics are important to predicting referrals, and household demographic factors in lead loss prediction. Finally, we find that referrals are both the highest quality and largest source of LMI solar leads, providing a promising mechanism to expand LMI programs further.

customer acquisition costs↗

Door to door short haul.

Present drawbacks to short-haul air transportation are partly related to passenger and baggage processing at air terminals and ground access difficulties. It is pointed out that the widely used automobile is the most inefficient mode of transportation. Various new developments in the field of ground transportation are considered. It is suggested to develop an integrated transportation system which would replace the various competing modes of automobile, bus, rail, and air with a single system for moving people and goods from their origins to their destinations. The Intermodal Automated Transfer system discussed would treat the passenger, his baggage, and the seat in which he travels as a unit which would stay together throughout a trip, regardless of the carrier used.

Steven, F. R.↗

Ultralight Door Design, Development and Demonstration Project (Final Scientific Report)

The project objectives associated with the Ultralight Door Project were to develop a lightweight driver's side door, 42.5% lighter than a current model year high-volume baseline door, at an incremental cost not to exceed $ \$ $ 5 per pound saved, while maintaining equivalent functionality, safety, corrosion, durability and sound transmission performance of the baseline vehicle. The project approach included the selection of a door architecture, development of a key performance target matrix and incremental cost model. Several unique door structures were developed and evaluated using computer-aided engineering (CAE) and cost modeling tools. The aluminum-intensive door structure was the only design capable of meeting both the performance and cost criteria objectives. The door module, glass, interior trim, latch and electrical subsystems were functionally integrated with the aluminum door structure, enabling additional mass reduction beyond material substitution. The lightweight door design was prototyped, integrated with baseline vehicles and tested to validate equivalent functionality and performance. The project results demonstrate a mass reduction of 15.2 kg (40%) at an incremental cost of $ \$ $2.81 per pound saved, while maintaining functionality and performance of the baseline door. The environmental benefit associated with the Ultralight Door enables a 6g CO 2 eq. per kilometer environmental benefit, for a 4-door vehicle powered by a downsized fuel injected gasoline combustion engine. The project results were presented and published in the 2018 SAE International Conference proceedings and in the Journal of Life Cycle Assessment.

36 MATERIALS SCIENCE↗

Door assembly with collapsible carrier

A door assembly for a motor vehicle comprised of an outer door panel and an inner door panel interconnected to define a door panel structure having an internal door cavity. A collapsible carrier module is configured to be oriented in a collapsed arrangement to facilitate installation into the door cavity through an opening in the inner door panel. The collapsible carrier module can be moved from its collapsed arrangement into an expanded arrangement upon installation within the door cavity to facilitate subsequent mounting to the door panel structure. The collapsible carrier module includes a two-piece carrier plate formed to integrally include a pair of laterally-spaced glass run channels and a pair of laterally-spaced slider rails.

42 ENGINEERING↗

Door assembly with collapsible carrier and water shield

A door assembly for a motor vehicle comprised of an outer door panel and an inner door panel interconnected to define a door panel structure having an internal door cavity. A collapsible carrier module is configured to be oriented in a collapsed arrangement to facilitate installation into the door cavity through an opening in the inner door panel. The collapsible carrier module can be moved from its collapsed arrangement into an expanded arrangement upon installation within the door cavity to facilitate subsequent mounting to the door panel structure. The collapsible carrier module includes a barrier configured to close off the opening in the inner panel.

Fortin, Raymond Edward↗

Motor actuated vacuum door

Doors that allow scientific instruments to record and retrieve the observed data are often required to be designed and installed as a part of sounding rocket hardware. The motor-actuated vacuum door was designed to maintain a medium vacuum of the order of 0.0001 torr or better while closed, and to provide an opening 15 inches long x 8.5 inches wide while open for cameras to image Halley's comet. When the electric motor receives the instruction to open the door through the payload battery, timer, and relay circuit, the first operation is to unlock the door. After unlatching, the torque transmitted by the motor to the main shaft through the links opens the door. A microswitch actuator, which rides on the linear motion conversion mechanism, is adjusted to trip the limit switch at the end of the travel. The process is repeated in the reverse order to close the door. 'O' rings are designed to maintain the seal. Door mechanisms similar to the one described have flown on Aerobee 17.018 and Black Brant 27.047 payloads.

Hanagud, A. V.↗

Solution for Direct Solar Impingement Problem on Landsat-7 ETM+ Cooler Door During Cooler Outgas in Flight

There was a thermal anomaly of the Landsat-7 Enhanced Thematic Mapper Plus (ETM+) radiative cooler cold stage during the cooler outgas phase in flight. With the cooler door in the outgas position and the outgas heaters enabled, the cold stage temperature increased to a maximum of 323 K when the spacecraft was in the sunlight, which was warmer than the 316.3 K upper set point of the outgas heater controller on the cold stage. Also, the outgas heater cycled off when the cold stage was warming up to 323 K. A corrective action was taken before the attitude of the spacecraft was changed during the first week in flight. One orbit before the attitude was changed, the outgas heaters were disabled to cool off the cold stage. The cold stage temperature increase was strongly dependent on the spacecraft roll and yaw. It provided evidence that direct solar radiation entered the gap between the cooler door and cooler shroud. There was a concern that the direct solar radiation could cause polymerization of hydrocarbons, which could contaminate the cooler and lead to a thermal short. After outgas with the cooler door in the outgas position for seven days, the cooler door was changed to the fully open position. With the cooler door fully open, the maximum cold stage temperature was 316.3 K when the spacecraft was in the sunlight, and the duty cycle of the outgas heater in the eclipse was the same as that in the sunlight. It provided more evidence that direct solar radiation had entered the gap between the cooler door and cooler shroud. Cooler outgas continued for seven more days, with the cooler door fully open. The corrective actions had prevented overheating of the cold stage and cold focal plane array (CFPA), which could damage these two components. They also minimized the risk of contamination on the cold stage, which could lead to a thermal short.

Choi, Michael K.↗

Door assembly with shear layer control aperture

There is described a vehicle door assembly with shear layer control for controlling the airflow in and around an aperture in the vehicle fuselage. The vehicle door assembly consists of an upper door and a lower door, both slidably mounted to the exterior surface of the vehicle fuselage. In addition, an inner door is slidably mounted beneath the upper door. Beneath the inner door is an aperture assembly having an aperture opening positionable to be substantially flush with the exterior surface of the vehicle fuselage. Also provided are means for positioning the aperture assembly in an upward and downward direction in relation to the vehicle fuselage.

Kahn, William C.↗

Exploration of a Potential DOOR Endpoint for Hospital-acquired Bacterial Pneumonia and Ventilator-associated Bacterial Pneumonia Using Six Registrational Trials for Antibacterial Drugs

Abstract Background Desirability of outcome ranking (DOOR) is an innovative approach to clinical trial design and analysis that uses an ordinal ranking system to incorporate the overall risks and benefits of a therapeutic intervention into a single measurement. Here we derived and evaluated a disease-specific DOOR endpoint for registrational trials for hospital-acquired bacterial pneumonia and ventilator-associated bacterial pneumonia (HABP/VABP). Methods Through comprehensive examination of data from nearly 4000 participants enrolled in six registrational trials for HABP/VABP submitted to the Food and Drug Administration (FDA) between 2005 and 2022, we derived and applied a HABP/VABP specific endpoint. We estimated the probability that a participant assigned to the study treatment arm would have a more favorable overall DOOR or component outcome than a participant assigned to comparator. Results DOOR distributions between treatment arms were similar in all trials. DOOR probability estimates ranged from 48.3% to 52.9% and were not statistically different. There were no significant differences between treatment arms in the component analyses. Although infectious complications and serious adverse events occurred more frequently in ventilated participants compared to non-ventilated participants, the types of events were similar. Conclusions Through a data-driven approach, we constructed and applied a potential DOOR endpoint for HABP/VABP trials. The inclusion of syndrome-specific events may help to better delineate and evaluate participant experiences and outcomes in future HABP/VABP trials and could help inform data collection and trial design.

Immunology↗

Ultra-clear Aerogels for Insulated Glass in Refrigeration Doors (CRADA Final Report)

Display refrigerators commonly employ glass doors to provide product visibility; however, these doors exhibit significantly poorer thermal insulation than solid doors, resulting in increased heat transfer and higher energy consumption. To address this limitation, this project investigated the use of silica aerogel as a transparent insulating medium for refrigerator glass doors, with the objective of enhancing thermal performance without compromising visual clarity. In Phase I of the project, we assessed the feasibility of silica aerogel insulation through laboratory and full-scale studies, including material characterization, durability testing, and heat transfer measurements, along with the development and performance evaluation of prototype glass doors under realistic operating conditions. In Phase II, the project focused on scaling the technology toward practical deployment. This included scaling up the manufacturing process to achieve a surface area roughly 20 times larger for commercial applications, developing full-scale prototypes that integrated silica aerogel into standard display refrigerator doors, and conducting field evaluations to assess thermal performance, energy savings, and operational durability under real-world conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neutronics Evaluation of the Preliminary Design of the Service Cell Door for the Second Target Station

The service cell door needs to provide sufficient shielding to achieve 0.25 mrem/h dose rates in the adjacent room while remote handling operations of waste materials are going on within the service cell for the Second Target Station (STS). This analysis provides a neutronics evaluation of the preliminary design of the service cell door to evaluate the required thickness and the effect of streaming gaps around the door. As radiation source, we use the decay gamma source of the moderator reflector assembly (MRA) of the STS with a decay time of either two days or six months. As the MRA contains a significant amount of beryllium, photonuclear reactions induce a neutron source, which dictates the required door thickness in certain situations. Four scenarios with different MRA positions and decay times have been analyzed. The required thickness differs drastically depending on the chosen scenario and on the material of the door. The streaming through the gaps around the door is relatively small with high dose rates limited to small sections of the geometry.

43 PARTICLE ACCELERATORS↗

Effects of wing/elevon gap sealing flapper doors on orbiter elevon effectiveness of model 16-0 in the NAAL 7.75 by 11 foot continuous flow wind tunnel (OA119A)

Space shuttle orbiter elevon effectiveness was measured with the 6 inch elevon/elevon and elevon/fuselage gaps and various configurations of wing/elevon upper hingeline gap sealing flapper doors. The elevon configuration parametric variations consisted of sealing the lower hingeline to prevent flow-through and testing a long chord flapper door, a short chord flapper door, no flapper door (elevon/wing gap upper hingeline completely open), and a completely sealed elevon at elevon deflections from +20 deg to -40 deg. Preliminary data analysis indicates loss of elevon effectiveness at deflections more negative than -20 deg, and little or no effect of flapper door configuration on elevon effectiveness. Flow visualization photographs taken at alpha = 15 deg for two flapper door configurations substantiated the force data results. Aerodynamic force and moment data were measured in the body axis by a 2.5 inch task type internal strain gage balance. The model was sting supported through the base region with a nominal angle of attack range of -10 deg less than or equal to alpha less than or equal to 24 deg at a model angle of sideslip of Beta equal to 0 deg.

Mennell, R.↗