Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIFFRACTED LIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Light Diffraction by Large Amplitude Ultrasonic Waves in Liquids

Light diffraction from ultrasound, which can be used to investigate nonlinear acoustic phenomena in liquids, is reported for wave amplitudes larger than that typically reported in the literature. Large amplitude waves result in waveform distortion due to the nonlinearity of the medium that generates harmonics and produces asymmetries in the light diffraction pattern. For standing waves with amplitudes above a threshold value, subharmonics are generated in addition to the harmonics and produce additional diffraction orders of the incident light. With increasing drive amplitude above the threshold a cascade of period-doubling subharmonics are generated, terminating in a region characterized by a random, incoherent (chaotic) diffraction pattern. To explain the experimental results a toy model is introduced, which is derived from traveling wave solutions of the nonlinear wave equation corresponding to the fundamental and second harmonic standing waves. The toy model reduces the nonlinear partial differential equation to a mathematically more tractable nonlinear ordinary differential equation. The model predicts the experimentally observed cascade of period-doubling subharmonics terminating in chaos that occurs with increasing drive amplitudes above the threshold value. The calculated threshold amplitude is consistent with the value estimated from the experimental data.

Adler, Laszlo↗

Laser agile illumination for object tracking and classification - Feasibility study

The 'agile illumination' concept for discrimination between ICBM warheads and decoys involves a two-aperture illumination with coherent light, diffraction of light by propagation, and a resulting interference pattern on the object surface. A scanning two-beam interference pattern illuminates one object at a time; depending on the shape, momentum, spinning, and tumbling characteristics of the interrogated object, different temporal signals will be obtained for different classes of objects.

Scholl, Marija S.↗

Stellar occultation probes of the Uranian rings at 0.1 and 2.2 microns - A comparison of Voyager UVS and earth-based results

A comparison between Voyager 2 UV spectrometer data for stellar occultations of the Uranian ring system obtained at 0.11 microns and 2.2-micron earth-based occultation data reveals the anticipated factor-of-two reduction in observed optical depths relative to those observed from earth. This is due to Voyager's proximity to the rings, which allows light diffracted out of the direct beam by ring particles to be replaced by light diffracted into the direct beam light from other particles, and further permits the placing of firm lower limits on typical particle sizes of 0.3 and 1 cm for the epsilon and delta rings, respectively. As a function of true anomaly, the epsilon ring profile is noted to remain very similar in shape and essentially constant in equivalent depth, even very near periapse.

Holberg, J. B.↗

Pointing Control System Architecture for the Eclipse Mission

This paper describes the high performance pointing control system used to point the Eclipse telescope. Eclipse is a new mission under study at Jet Propulsion Laboratory for a proposal as a discovery mission. Eclipse is a space telescope for high-contrast optical astronomy. It will be used to investigate the planetary bodies and environments. The main objective of the Eclipse mission is to study planets around nearby stars. Eclipse is designed to reveal planets or dust structures by reducing the scattered and diffracted light within a few arcseconds of a star to a level three orders of magnitude lower than any instrument on the Hubble Space Telescope (HST). Eclipse achieves this high contrast using a 1.8 meter diameter telescope, a coronagraphic system for control of diffracted light, and active wavefront correction using a Precision Deformable Mirror (DM) for the suppression of scattered light. The observatory will be launched into a Sun-synchronous 690 Km, 98.2(deg) Earth Orbit in 2012.

architecture↗

Research and Development of External Occultor Technology for the Direct Observation of Extrasolar Planetary Systems : JPL Starshades Project

Our group conducted work during the Summer of 2012 assembling and developing JPL's Starshades Project under the Technology Development for Exoplanet Missions(TDEM) initiative created by NASA, specifically TDEM stage 2. The goal of the work conducted at JPL by our group was to construct four occultor petals, the main optical components of the Starshade, for the analysis of joint deployment characteristics and of mechanical strain. A Starshade is an optical structure measuring approximately 30 meters in diameter that uses the effects of light diffraction off sheer edges, light scattering, and negative interference between waves to negate all on-axis light in a telescope's image, providing very high contrast that allows planets orbiting a target star to be observed. We completed our engineering goals in the time span of 10 weeks, during which the assembly processes of manufacture, alignment, and structural bonding took place. The Starshade technology and construction process is further discussed in the body of this paper.

exoplanet missions↗

Diffraction by fractally serrated apertures

An investigation of light diffracted by irregularly serrated apertures yields a closed-form analytical solution that confirms experimental recording of the diffracted patterns. These serrated apertures are modeled by a fractal function. Examples are given for both sinusoidal and fractal aperture perimeters with varying fractal dimension. Relations between the far-zone diffracted fields and the fractal dimension are examined.

Kim, Y.↗

Conically Scanned Holographic LIDAR Telescope

Holographic LIDAR telescope includes holographic disk, rotation of which sweeps collimated, monochromatic beam of light from laser through conical scan. Holographic disk diffracts light scattered back from target volume or area to focal point located at stationary photomultiplier detector. Two conical baffles prevent stray light from reaching detector.

Schwemmer, Geary↗

A Case Study in High Contrast Coronagraph for Planet Discovery: The Eclipse Concept and Support Laboratory Experience

Eclipse is a proposed NASA Discovery mission to perform a sensitive imaging survey of nearby planetary systems, including a survey for jovian-sized planets orbiting Sun-like stars to distances of 15 pc. We outline the science objectives of the Eclipse mission and review recent developments in the key enabling technologies. Eclipse is a space telescope concept for high-contrast visible-wavelength imaging and spectrophotometry. Its design incorporates a telescope with an unobscured aperture of 1.8 meters, a coronographic camera for suppression of diffracted light, and precise active wavefront correction for the suppression of scattered background light. For reference, Eclipse is designed to reduce the diffracted and scattered starlight between 0.33 and 1.5 arcseconds from the star by three orders of magnitude compared to any HST instrument. The Eclipse mission provides precursor science exploration and technology experience in support of NASA's Terrestrial Planet Finder (TPF) program.

coronagraphic imaging testbed↗

Space optics for studying extra-solar planetary systems

The sharp imaging of telescopes in space will improve the ability to see faint objects near bright ones. One exciting application is the search for planets around other stars. However, because a planet is, at best, 10 exp 9 times fainter than a star in visible light, specialized optical systems are required. Using apodization to remove diffracted light, the limiting source of noise is the intensity of starlight scattered by mirror figure errors. Based on the prelaunch metrology of the HST mirrors, and considering only photonstatistics, months of integration would be needed for HST to detect Jupiter next to the sun at a distance of 5 pc. The integration times will be shorter for future telescopes in space with smoother mirrors and/or larger apertures.

Brown, Robert A.↗

Crossover Concept for Optical Printed Circuits

It is possible to reduce crosstalk between optical signals in intersecting optical conductors by taking two steps: Minimize amount of light diffracted into wrong conductor by selecting optimum conductor width, and place light traps in each conductor. How well techniques work depends in part on quality of optical conductors (partically surface smoothness) and on how closely optical-signal mode of propagation approaches ideal. Nature of signals also important: With digital signals, less crosstalk attenuation required than for analog signals.

Jamieson, R. S.↗

Use of rotating pinholes and reticles for calibration of cloud droplet instrumentation

Calibration devices for the Forward Scattering Spectrometer Probe (FSSP) and the Optical Array Probe (OAP) were developed. The device used with the FSSP is a rotating pinhole calibrator. It utilizes light diffracted by a pinhole of a known diameter to simulate scattered light from a water droplet. This device can be used to calibrate the FSSP, measure the FSSP's optical collection angles and for instrument alignment and troubleshooting. The device used with the OAP is a rotating reticle calibrator. Chrome disks of a known diameter on the reticle are used for calibration of the OAP and for determining the OAP's response to out-of-focus particles in the probe volume.

Hovenac, Edward A.↗

Nanostructure Secondary-Mirror Apodizing Mask for Transmitter Signal Suppression in a Duplex Telescope

A document discusses a nanostructure apodizing mask, made of multi-walled carbon nanotubes, that is applied to the centers (or in and around the holes) of the secondary mirrors of telescopes that are used to interferometrically measure the strain of space-time in response to gravitational waves. The shape of this ultra-black mask can be adjusted to provide a smooth transition to the clear aperture of the secondary mirror to minimize diffracted light. Carbon nanotubes grown on silicon are a viable telescope mirror substrate, and can absorb significantly more light than other black treatments. The hemispherical reflectance of multi-walled carbon nanotubes grown at GSFC is approximately 3 to 10 times better than a standard aerospace paint used for stray light control. At the LISA (Laser Interferometer Space Antenna) wavelength of 1 micron, the advantage over paint is a factor of 10. Primarily, in the center of the secondary mirror (in the region of central obscuration, where no received light is lost) a black mask is applied to absorb transmitted light that could be reflected back into the receiver. In the LISA telescope, this is in the center couple of millimeters. The shape of this absorber is critical to suppress diffraction at the edge. By using the correct shape, the stray light can be reduced by approximately 10 to the 9 orders of magnitude versus no center mask. The effect of the nanotubes has been simulated in a stray-light model. The effect of the apodizing mask has been simulated in a near-field diffraction model. Specifications are geometry-dependent, but the baseline design for the LISA telescope has been modeled as well. The coatings are somewhat fragile, but work is continuing to enhance adhesion.

Hagopian, John↗

Fabrication experiments on supersmooth optics for extrasolar planet detection

The direct detection of extrasolar planets by imaging will require reductions in scattered and diffracted light by factors in excess of 1000 within one arcsecond of a bright source. While diffraction can be reduced by a number of approaches, small angle scatter can only be reduced by controlling midspatial frequency figure errors. The surface requirements are reviewed and their meaning when compared to the data base of existing mirrors is considered. Experiments are discribed that were successful in reducing midspatial frequency figure so that the scatter level was 500 times less than diffraction for a 25-cm spherical mirror.

Ftaclas, C.↗

Simulation and Measurement of Stray Light in the CLASP

We are planning an international rocket experiment Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is (2015 planned) that Lyman Alpha line polarization spectroscopic observations from the sun. The purpose of this experiment, detected with high accuracy of the linear polarization of the Ly􀉲 lines to 0.1% by using a Hanle effect is to measure the magnetic field of the chromosphere-transition layer directly. For total flux of the sun visible light overwhelmingly larger and about 200 000 times the Ly􀉲 line wavelength region, also hinder to 0.1% of the polarization photometric accuracy achieved in the stray light of slight visible light. Therefore we were first carried out using the illumination design analysis software called stray light simulation CLASP Light Tools. Feature of this simulation, using optical design file (ZEMAX format) and structural design file (STEP format), to reproduce realistic CLASP as possible to calculate machine is that it was stray study. And, at the stage in the actual equipment that made the provisional set of CLASP, actually put sunlight into CLASP using coelostat of National Astronomical Observatory of Japan, was subjected to measurement of stray light (San test). Pattern was not observed in the simulation is observed in the stray light measurement results need arise that measures. However, thanks to the stray light measurement and simulation was performed by adding, it was found this pattern is due to the diffracted light at the slit. Currently, the simulation results is where you have taken steps to reference. In this presentation, we report the stray light simulation and stray light measurement results that we have implemented

CLASP↗

Even Illumination from Fiber-Optic-Coupled Laser Diodes

A method of equipping fiber-optic-coupled laser diodes to evenly illuminate specified fields of view has been proposed. The essence of the method is to shape the tips of the optical fibers into suitably designed diffractive optical elements. One of the main benefits afforded by the method would be more nearly complete utilization of the available light. Diffractive optics is a relatively new field of optics in which laser beams are shaped by use of diffraction instead of refraction.

Howard, Richard T.↗

Correcting for diffraction in the far-infrared reflectance measurement of rough surfaces

The manner in which diffraction can increase the reflectance measured from very rough surfaces is shown by observations of diffracted light within the instrument profile of a far-IR reflectometer system. A correction to the calibration signal based on numerical integration of the diffracted part of the instrument profile is described. Diffraction correction factors as large as 2.94 have been found with small optics at long wavelength (630 microns). The effect of diffraction on diffuse reflectance measurements of a very rough perfect reflector is shown at wavelengths from 56 to 200 microns.

Smith, Sheldon M.↗

The STIS CCD Spectroscopic Line Spread Functions

We characterize the spectroscopic line spread functions of the spectroscopic CCD modes for high contrast objects. Our long range goal is to develop tools that accurately extract spectroscopic information of faint, point or extended sources in the vicinity of bright, point sources at separations approaching the realizable angular limits of HST with STIS. Diffracted and scattered light due to the HST optics, and scattered light effects within the STIS are addressed. Filter fringing, CCD fringing, window reflections, and scattering within the detector and other effects are noted. We have obtained spectra of several reference stars, used for flux calibration or for coronagraphic standards, that have spectral distributions ranging from very red to very blue. Spectra of each star were recorded with the star in the aperture and with the star blocked by either the F1 or F2 fiducial. Plots of the detected starlight along the spatial axis of the aperture are provided for four stars. With the star in the aperture, the line spread function is quite noticeable. Placing the star behind one of the fiducials cuts the scattered light and the diffracted light, is detectable even out to 1OOOOA. When the star is placed behind either fiducial, the scattered and diffracted light components, at three arcseconds displacement from the star, are below lop6 the peak of the star at wavelengths below 6000A; at the same angular distance, scattered light does contaminate the background longward of 6000A up to a level of 10(exp -5).

Gull, T.↗