Phoenix Lander's Thermal Evolved Gas Analyzer: Differential Scanning Calorimeter and Mass Spectrometer Database Development

The Mars Scout Phoenix lander will land in the north polar region of Mars in May, 2008. One objective of the Phoenix lander is to search for evidence of past life in the form of molecular organics that may be preserved in the subsurface soil. The Thermal Evolved Gas Analyzer (TEGA) was developed to detect these organics by coupling a simultaneous differential thermal analyzer (SDTA) with a mass spectrometer. Martian soil will be heated to approx.1000 C and potential organic decomposition products such as CO2, CH4 etc. will be examined for with the MS. TEGA s SDTA will also assess the presence of endothermic and exothermic reactions that are characteristic of soil organics and minerals as the soil is heated. The MS in addition to detecting organic decompositon products, will also assess the levels of soil inorganic volatiles such as H2O, SO2, and CO2. Organic detection has a high priority for this mission; however, TEGA has the ability to provide valuable insight into the mineralogical composition of the soil. The overall goal of this work is to develop a TEGA database of minerals that will serve as a reference for the interpretation of Phoenix-TEGA. Previous databases for the ill-fated Mars Polar Lander (MPL)-TEGA instrument only went to 725 C. Furthermore, the MPL-TEGA could only detect CO2 and H2O while the Phoenix-TEGA MS can examine up to 144 atomic mass units. The higher temperature Phoenix-TEGA SDTA coupled with the more capable MS indicates that a higher temperature database is required for TEGA interpretation. The overall goal of this work is to develop a differential scanning calorimeter (DSC) database of minerals along with corresponding MS data of evolved gases that can used to interpret TEGA data during and after mission operations. While SDTA and DSC measurement techniques are slightly different (SDTA does not use a reference pan), the results are fundamentally similar and thus DSC is a useful technique in providing comparative data for the TEGA database. The objectives of this work is to conduct DSC and MS analysis up to 1000 C of select minerals that may be found in the martian soil.

Sutter, B.↗

Document Set Differentiability Analyzer v. 0.1

Software is a JMP Scripting Language (JSL) script designed to evaluate the differentiability of a set of documents that exhibit some conceptual commonalities but are expected to describe substantially different – thus differentiable – categories. The script imports the document set, a subset of which may be partitioned into an additions pool. The bulk of the documents form a basis pool. Text analysis is applied to the basis pool to extract a mathematical representation of its conceptual content, referred to as the document concept space. A bootstrapping approach is applied to that mathematical representation in order to generate a representation of a large population of randomly designed documents that could be written within the concept space, notably without actually writing the text of those documents.The Kolmogorov-Smirnov test is applied to determine whether the basis pool document set exhibits superior differentiation relative to the randomly designed virtual documents produced by bootstrapping. If an additions pool exists, the documents are incrementally added to the basis pool, choosing the best differentiated remaining document at each step. In this manner the impact of additional categories to overall document set differentiability may be assessed.The software was developed to assess the differentiability of job description document sets. Differentiability is key to meaningful categorization. Poor job differentiation may have economic, ethical, and/or legal implications for an organization. Job categories are used in the assignment of market-based salaries; consequently, poor differentiation of job duties may set the stage for legal challenges if very similar jobs pay differently depending on title, a circumstance that also invites economic waste.The software can be applied to ensure job description set differentiability, reducing legal, economic, and ethical risks to an organization and its people. The extraction of the conceptual space to a mathematical representation enables identification of exceedingly similar documents. In the event of redundancy, two jobs may be collapsed into one. If in the judgment of the subject matter experts the jobs are truly different, the conceptual similarities are highlighted, inviting inclusion of appropriate descriptive content to explicitly characterize those differences. When additional job categories may be needed as the organization changes, the software enables evaluation of proposed additions to ensure that the resulting document set remains adequately differentiated.

Osborn, Thor D.↗

Efficacy of a portable, moderate-resolution, fast-scanning differential mobility analyzer for ambient aerosol size distribution measurements

Abstract. Ambient aerosol size distributions obtained with a compact scanning mobility analyzer, the “Spider” differential mobility analyzer (DMA), are compared to those obtained with a conventional mobility analyzer, with specific attention to the effect of mobility resolution on the measured size distribution parameters. The Spider is a 12 cm diameter radial differential mobility analyzer that spans the 10–500 nm size range with 30 s mobility scans. It achieves its compact size by operating at a nominal mobility resolution R=3 (sheath flow = 0.9 L min−1; aerosol flow = 0.3 L min−1) in place of the higher ratio of sheath flow to aerosol flow commonly used. The question addressed here is whether the lower resolution is sufficient to capture key characteristics of ambient aerosol size distributions. The Spider, operated at R=3 with 30 s up- and downscans, was co-located with a TSI 3081 long-column mobility analyzer, operated at R=10 with a 360 s sampling duty cycle. Ambient aerosol data were collected over 26 consecutive days of continuous operation, in Pasadena, CA. Over the 17–500 nm size range, the two instruments exhibit excellent correlation in the total particle number concentrations and geometric mean diameters, with regression slopes of 1.13 and 1.00, respectively. Our results suggest that particle sizing at a lower resolution than typically employed may be sufficient to obtain key properties of ambient size distributions, at least for these two moments of the size distribution. Moreover, it enables better counting statistics, as the wider transfer function for a given aerosol flow rate results in a higher counting rate.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of assumptions made by Hygroscopic Tandem Differential Mobility Analyzer inversion routines

The Hygroscopic Tandem Differential Mobility Analyzer (H-TDMA) measures the hygroscopicity of atmospheric particles, and many atmospheric processes that change this hygroscopicity also change the atmospheric size distribution. Two assumptions made during H-TDMA inversion create spurious hygroscopic trends as a function of the changing inlet size distribution. These two assumptions—that the particles exiting the first Differential Mobility Analyzer (DMA1) are singly charged and that the inlet size distribution has a slope of zero (flat)— generate Multi-Charge Dispersion (MCD) bias and Slope bias, respectively. First, we use a model, named TAO, to show that the inlet size distribution could theoretically change the measured ammonium sulfate hygroscopicity by 10%–20% as a function of diameter or experimental time with no change in relative humidity. Secondly, we show experimentally that aerosol emitted from the flaming combustion of grass creates MCD bias. Here, in this experiment, we measure the CPC response of the first three charges and invert these responses using a new routine named Junior. Junior's inversion of each charge shows that one growth factor distribution describes all measured diameters (no growth dependence on diameter). As in the modeling study above, previous publications of this aerosol system, using traditional inversion assumptions, report a decrease in hygroscopicity as DMA1 diameter increases. Unlike traditional inversions, Junior's inversion does not assume the particles are singly charged nor does it make the flat inlet size distribution assumption. Instead, both the inlet size distribution and each charge's CPC response are measured quantities. Thus, the discrepancy between our inversion results and previous publications is likely due to the traditional inversion routine assumptions. This underscores the importance for accounting for Slope and MCD bias during inversions. Experimental results should be carefully analyzed when reporting hygroscopic trends with respect to diameter or experimental time when using the traditional inversion assumptions.

42 ENGINEERING↗

3002 Humidified Tandem Differential Mobility Analyzer (HTDMA) Instrument Handbook

The Brechtel Manufacturing Inc. (BMI) Humidified Tandem Differential Mobility Analyzer (HT-DMA Model 3002) (Brechtel and Kreidenweis 2000a,b, Henning et al. 2005, Xerxes et al. 2014) measures how aerosol particles of different initial dry sizes grow or shrink when exposed to changing relative humidity (RH) conditions. It uses two different mobility analyzers (DMA) and a humidification system to make the measurements. One DMA selects a narrow size range of dry aerosol particles, which are exposed to varying RH conditions in the humidification system. The second (humidified) DMA scans the particle size distribution output from the humidification system. Scanning a wide range of particle sizes enables the second DMA to measure changes in size or growth factor (growth factor = humidified size/dry size), due to water uptake by the particles. A Condensation Particle Counter (CPC) downstream of the second DMA counts particles as a function of selected size in order to obtain the number size distribution of particles exposed to different RH conditions.

54 ENVIRONMENTAL SCIENCES↗

Electric wind in a Differential Mobility Analyzer

Electric wind -- the movement of gas, induced by ions moving in an electric field -- can be a distorting factor in size distribution measurements using Differential Mobility Analyzers (DMAs). The aim of this study was to determine the conditions under which electric wind occurs in the locally-built VLDMA (Very Long Differential Mobility Analyzer) and TSI Long-DMA (3081) and to describe the associated distortion of the measured spectra. Electric wind proved to be promoted by the increase of electric field strength, aerosol layer thickness, particle number concentration and particle size. The measured size spectra revealed three types of distortion: widening of the size distribution, shift of the mode of the distribution to smaller diameters and smoothing out the peaks of the multiply charged particles. Electric wind may therefore be a source of severe distortion of the spectrum when measuring large particles at high concentrations.

54 ENVIRONMENTAL SCIENCES↗

Mobility Peak Tailing Reduction in a Differential Mobility Analyzer (DMA) Coupled with a Mass Spectrometer and Several Ionization Sources

The differential mobility analyzer (DMA) is a narrow-band linear ion mobility filter operating at atmospheric pressure. It combines in series with a quadrupole mass spectrometer (Q-MS) for mobility/mass analysis, greatly reducing chemical noise in selected ion monitoring. However, the large flow rate of drift gas (~1000 L/min) required by DMAs complicates the achievement of high gas purity. Additionally, the symmetry of the drying counterflow gas at the interface of many commercial MS instruments, is degraded by the lateral motion of the drift gas at the DMA entrance slit. As a result, DMA mobility peaks often exhibit tails due to the attachment of impurity vapors, either (1) to the reagent ion within the separation cell, or (2) to the analyte of interest in the ionization region. In order to greatly increase the noise-suppression capacity of the DMA, we describe various vapor-removal schemes and measure the resulting increase in the tailing ratio, (TR = signal at the peak maximum over signal two half-widths away from this maximum). Here we develop a low-outgassing DMA circuit connected to a mass spectrometer, and test it with three ionization sources (APCI, Desolvating-nano ESI, and Desolvating low flow SESI). While prior TR values were in the range 100–1000, the three new sources achieve TR ~ 10{sup 5}. The SESI source has been optimized for maximum sensitivity, delivering an unprecedented gain for TNT of 190 counts/fg, equivalent to an ionization efficiency of one out of 140 neutral molecules. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revisiting matrix-based inversion of scanning mobility particle sizer (SMPS) and humidified tandem differential mobility analyzer (HTDMA) data

Abstract. Tikhonov regularization is a tool for reducing noise amplification during data inversion. This work introduces RegularizationTools.jl, a general-purpose software package for applying Tikhonov regularization to data. The package implements well-established numerical algorithms and is suitable for systems of up to ∼ 1000 equations. Included is an abstraction to systematically categorize specific inversion configurations and their associated hyperparameters. A generic interface translates arbitrary linear forward models defined by a computer function into the corresponding design matrix. This obviates the need to explicitly write out and discretize the Fredholm integral equation, thus facilitating fast prototyping of new regularization schemes associated with measurement techniques. Example applications include the inversion involving data from scanning mobility particle sizers (SMPSs) and humidified tandem differential mobility analyzers (HTDMAs). Inversion of SMPS size distributions reported in this work builds upon the freely available software DifferentialMobilityAnalyzers.jl. The speed of inversion is improved by a factor of ∼ 200, now requiring between 2 and 5 ms per SMPS scan when using 120 size bins. Previously reported occasional failure to converge to a valid solution is reduced by switching from the L-curve method to generalized cross-validation as the metric to search for the optimal regularization parameter. Higher-order inversions resulting in smooth, denoised reconstructions of size distributions are now included in DifferentialMobilityAnalyzers.jl. This work also demonstrates that an SMPS-style matrix-based inversion can be applied to find the growth factor frequency distribution from raw HTDMA data while also accounting for multiply charged particles. The outcome of the aerosol-related inversion methods is showcased by inverting multi-week SMPS and HTDMA datasets from ground-based observations, including SMPS data obtained at Bodega Marine Laboratory during the CalWater 2/ACAPEX campaign and co-located SMPS and HTDMA data collected at the US Department of Energy observatory located at the Southern Great Plains site in Oklahoma, USA. Results show that the proposed approaches are suitable for unsupervised, nonparametric inversion of large-scale datasets as well as inversion in real time during data acquisition on low-cost reduced-instruction-set architectures used in single-board computers. The included software implementation of Tikhonov regularization is freely available, general, and domain-independent and thus can be applied to many other inverse problems arising in atmospheric measurement techniques and beyond.

54 ENVIRONMENTAL SCIENCES↗

DAA realizations of attitude algorithms

The attitude algorithms applied to strapdown inertial platforms are discussed. A review of six attitude transformation algorithms and the realizations of these algorithms by digital differential analyzers are presented. The number of digital differential analyzers for each algorithm is either smaller than or equal to that obtained by others.

Hung, J. C.↗

Highly portable radial differential mobility analyzer

The present disclosure describes a compact and lightweight, radial-flow DMA designed to operate at low aerosol and sheath flowrates (on the order of 0.3 L/min aerosol flow, and 0.6-1.2 L/min sheath flow) and so as to classify aerosols including particles having sizes in the 10-500 nm range. Thus, the DMA is capable of operating at relatively low resolution (RND=2-4) to minimize both instrument volume and pumping/power requirements, while enabling size distribution measurement with the precision required for desired applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗