Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Critical Care Dialysis System

Organon Teknika Corporation's REDY 2000 dialysis machine employs technology originally developed under NASA contract by Marquardt Corporation. The chemical process developed during the project could be applied to removing toxic waste from used dialysis fluid. This discovery led to the development of a kidney dialysis machine using "sorbent" dialysis, a method of removing urea from human blood by treating a dialysate solution. The process saves electricity and, because the need for a continuous water supply is eliminated, the patient has greater freedom.

Source record↗

Apparatus for diffusion controlled dialysis under microgravity conditions

Apparatus for implementing crystal growth by allowing mixing of solutions under microgravity conditions includes a housing within which a number of pairs of chambers are formed. The chambers of each pair are aligned and a rotary valve is positioned between the chambers of each pair. When the valve is in a first position one chamber of each pair may communicate with the other chamber. A separate valve is provided for each pair of chambers so that each pair of chambers may be activated independently of the others and sequentially at selected intervals. Protein solution may be located within a small cavity in a cap which closes one of the chambers of a pair, and the cavity in the cap is closed by a dialysis membrane. The length of certain pairs of chambers may differ from the length of other pairs of chambers to optimize conditions for various dialysis productions, and wicking material may be incorporated into selected chambers for controlling the critical approach to supersaturation.

Carter, Daniel C.↗

Positively charged membrane for urea dialysis

Positively charged, porous membrane dividing two chamber dialysis machine allows urease decomposition within system while preventing return flow of ammonium ions to patient.

Mueller, W. A.↗

Dialysis Extraction for Chromatography

Chromatographic-sample pretreatment by dialysis detects traces of organic contaminants in water samples analyzed in field with minimal analysis equipment and minimal quantities of solvent. Technique also of value wherever aqueous sample and solvent must not make direct contact.

Jahnsen, V. J.↗

Dialysis system

The improved hemodialysis system utilizes a second polymeric membrane having dialyzate in contact with one surface and a urea decomposition solution in contact with the other surface. The membrane selectively passes urea from the dialyzate into the decomposition solution, while preventing passage of positively charged metal ions from the dialyzate into the solution and ammonium ions from the solution into the dialyzate.

Mueller, W. A.↗

Preliminary investigations of protein crystal growth using the Space Shuttle

Four preliminary Shuttle experiments are described which have been used to develop prototype hardware for a more advanced system that will evaluate effects of gravity on protein crystal growth. The first phase of these experiments has centered on the development of micromethods for protein crystal growth by vapor-diffusion techniques (using a space version of the hanging-drop method) and on dialysis using microdialysis cells. Results suggest that the elimination of density-driven sedimentation can effect crystal morphology. In the dialysis experiment, space-grown crystals of concanavalin B were three times longer and 1/3 the thickness of earth-grown crystals.

Delucas, L. J.↗

In vitro measurement of nucleus pulposus swelling pressure: A new technique for studies of spinal adaptation to gravity

Swelling of the intervertebral disc nucleus pulposus is altered by posture and gravity. We have designed and tested a new osmometer for in vitro determination of nucleus pulposus swelling pressure. The functional principle of the osmometer involves compressing a sample of nucleus pulposus with nitrogen gas until saline pressure gradients across a 0.45 microns Millipore filter are eliminated. Swelling pressure of both pooled dog and pooled pig lumbar disc nucleus pulposus were measured on the new osmometer and compared to swelling pressures determined using the equilibrium dialysis technique. The osmometer measured swelling pressures comparable to those obtained by the dialysis technique. This osmometer provides a rapid, direct, and accurate measurement of swelling pressure of the nucleus pulposus.

Hargens, A. R.↗

Effects of Purification on the Crystallization of Lysozyme

We have additionally purified a commercial lysozyme preparation by cation exchange chromatography, followed by recrystallization. This material is 99.96% pure with respect to macromolecular impurities. At basic pH, the purified lysozyme gave only tetragonal crystals at 20 C. Protein used directly from the bottle, prepared by dialysis against distilled water, or which did not bind to the cation exchange column had considerably altered crystallization behavior. Lysozyme which did not bind to the cation exchange column was subsequently purified by size exclusion chromatography. This material gave predominately bundles of rod-shaped crystals with some small tetragonal crystals at lower pHs. The origin of the bundled rod habit was postulated to be a thermally dependent tetragonal- orthorhombic change in the protein structure. This was subsequently ruled out on the basis of crystallization behavior and growth rate experiments. This suggests that heterogeneous forms of lysozyme may be responsible. These results demonstrate three classes of impurities: (1) small molecules, which may be removed by dialysis; (2) macromolecules, which are removable by chromatographic techniques; and (3) heterogeneous forms of the protein, which can be removed in this case by cation exchange chromatography. Of these, heterogeneous forms of the lysozyme apparently have the greatest affect on its crystallization behavior.

Ewing, Felecia L.↗

The Growth of Protein Crystals Using McDUCK

Most of the current microgravity crystal growth hardware is optimized to produce crystals within the limited time available on orbit. This often results in the actual nucleation and growth process being rushed or the system not coming to equilibrium within the limited time available. Longer duration hardware exists, but one cannot readily pick out crystals grown early versus those which nucleated and grew more slowly. We have devised a long duration apparatus, the Multi-chamber Dialysis Unit for Crystallization Kinetics, or McDUCK. This apparatus-is a series of protein chambers, stacked upon a precipitant reservoir chamber. All chambers are separated by a dialysis membrane, which serves to pass small molecules while retaining the protein. The volume of the Precipitant chamber is equal to the sum of the volumes of the protein chamber. In operation, the appropriate chambers are filled with precipitant solution or protein solution, and the McDUCK is placed standing upright, with the precipitant chamber on the bottom. The precipitant diffuses upwards over time, with the time to reach equilibration a function of the diffusivity of the precipitant and the overall length of the diffusion pathway. Typical equilibration times are approximately 2-4 months, and one can readily separate rapid from slow nucleation and growth crystals. An advantage on Earth is that the vertical precipitant concentration gradient dominates that of the solute, thus dampening out solute density gradient driven convective flows. However, large Earth-grown crystals have so far tended to be more two dimensional. Preliminary X-ray diffraction analysis of lysozyme crystals grown in McDUCK have indicated that the best, and largest, come from the middle chambers, suggesting that there is an optimal growth rate. Further, the improvements in diffraction resolution have been better signal to noise ratios in the low resolution data, not an increase in resolution overall. Due to the persistently large crystals grown we are currently proposing McDUCK for the growth of macromolecule crystals for use in neutron diffraction studies.

Ewing, Felicia↗

Nano Sponges for Drug Delivery and Medicinal Applications

This invention is a means of delivering a drug, or payload, to cells using non-covalent associations of the payload with nano-engineered scaffolds; specifically, functionalized single-walled carbon nanotubes (SWNTs) and their derivatives where the payload is effectively sequestered by the nanotube's addends and then delivered to the site (often interior of a cell) of interest. Polyethylene glycol (PEG) and other water-soluble organic molecules have been shown to greatly enhance the solubility of SWNTs in water. PEG groups and other water-solubilizing addends can act to sequester (sponge) molecules and deliver them into cells. Using PEG that, when attached to the SWNTs, the SWNT/PEG matrix will enter cells has been demonstrated. This was visualized by the addition of fluorescein isothiocyanate (FITC) to the SWNT/PEG matrix. Control studies showed that both FITC alone and FITC/PEG did not enter the cells. These observations suggest that the FITC is highly associated with the SWNT/PEG matrix that brings the FITC into the cells, allowing visualization of SWNTs in cells. The FITC is not covalently attached, because extended dialysis in hot DMF will remove all fluorescence quickly (one week). However, prolonged dialysis in water (1-2 months) will only slowly diminish the fluorescence. This demonstrates that the SWNT/PEG matrix solubilizes the FITC by sequestering it from the surrounding water and into the more solubilizing organic environment of the SWNT/PEG matrix of this type. This can be extended for the sequestering of other molecules such as drugs with PEG and other surfactants.

Tour, James M.↗

Large volume continuous counterflow dialyzer has high efficiency

Dialyzer separates macromolecules from small molecules in large volumes of solution. It takes advantage of the high area/volume ratio in commercially available 1/4-inch dialysis tubing and maintains a high concentration gradient at the dialyzing surface by counterflow.

Mandeles, S.↗

Small, low cost, artificial kidney

Disposable hemodialyzer is described that can be used at home by non-medically trained personnel. Short lengths of semipermeable membrane tubes are arranged in parallel, supported by plastic mesh and encased in epoxy at ends. Tubes are connected to input and output blood manifolds which are separated by dialysate chamber. Daily dialysis requires only two hours or less.

Lavender, A. R.↗