Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAGNOSTIC USES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Synthetic diagnostic for the beam emission spectroscopy diagnostic using a full optical integration

The beam emission spectroscopy (BES) diagnostic is used to measure fluctuations of electron density in the edge and core of fusion plasmas, and is a key in understanding turbulence in a plasma reactor. A synthetic BES diagnostic for the turbulence simulation code XGC1 has been developed using a realistic neutral beam model and an optical system easily adaptable to different kinds of tokamaks. The beam is modeled using multiple beam energy components, each one with a fraction of the total energy and their own mass and energy (mono-energetic components). The optical system consists of a lens focusing a bundle of optical fibers and resulting in a 2D measurement. The synthetic diagnostic gives similar correlation functions and behaviour of the turbulences than the usual methods that do not take into account the full 3D optical effects. The results, based on a simulation of XGC1, contain an analysis of the correlation (in space and time), a comparison of different approximations possible and their importance in accurately modeling the BES diagnostic.

Physics↗

On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing

The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this paper, radio frequency (RF) sensors were used to directly monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Finally and furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.

42 ENGINEERING↗

Time-dependent analysis of visible helium line-ratios for electron temperature and density diagnostic using synthetic simulations on NSTX-U

Helium line-ratios for electron temperature (T{sub e}) and density (n{sub e}) plasma diagnostic in the Scrape-Off-Layer (SOL) and edge regions of tokamaks are widely used. Due to their intensities and proximity of wavelengths, the singlet, 667.8 and 728.1 nm, and triplet, 706.5 nm, visible lines have been typically preferred. Time-dependency of the triplet line (706.5 nm) has been previously analyzed in detail by including transient effects on line-ratios during gas-puff diagnostic applications. In this work, several line-ratio combinations within each of the two spin systems are analyzed with the purpose of eliminating transient effects to extend the application of this powerful diagnostic to high temporal resolution characterization of plasmas. The analysis is done using synthetic emission modeling and diagnostic for low electron density NSTX SOL plasma conditions by several visible lines. Quasi-static equilibrium and time-dependent models are employed to evaluate transient effects of the atomic population levels that may affect the derived electron temperatures and densities as the helium gas-puff penetrates the plasma. The analysis of a wider range of spectral lines will help to extend this powerful diagnostic to experiments where the wavelength range of the measured spectra may be constrained either by limitations of the spectrometer or by other conflicting lines from different ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗

A simple algorithm for beam profile diagnostics using a thermographic camera

A new algorithm for digital image processing apparatuses is developed to evaluate profiles of high-intensity DC beams from temperature images of irradiated thin foils. Numerical analyses are performed to examine the reliability of the algorithm. To simulate the temperature images acquired by a thermographic camera, temperature distributions are numerically calculated for 20 MeV proton beams with different parameters. Noise in the temperature images which is added by the camera sensor is also simulated to account for its effect. Using the algorithm, beam profiles are evaluated from the simulated temperature images and compared with exact solutions. We find that niobium is an appropriate material for the thin foil used in the diagnostic system. We also confirm that the algorithm is adaptable over a wide beam current range of 0.11–214 μA, even when employing a general-purpose thermographic camera with rather high noise (ΔT{sub NETD} ≃ 0.3 K; NETD: noise equivalent temperature difference)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of plasma diagnostics using a dual frequency harmonic technique

Plasma diagnostic methods using harmonic currents analysis of electrostatic probes were experimentally investigated to understand the differences in their measurement of the plasma parameters. When dual frequency voltage (ω{sub 1},ω{sub 2}) was applied to a probe, various harmonic currents (ω{sub 1}, 2ω{sub 1},ω{sub 2}, 2ω{sub 2},ω{sub 2}±ω{sub 1},ω{sub 2}±2ω{sub 1}) were generated due to the non-linearity of the probe sheath. The electron temperature can be obtained from the ratio of the two harmonics of the probe currents. According to the combinations of the two harmonics, the sensitivities in the measurement of the electron temperature differed, and this results in a difference of the electron temperature. From experiments and simulation, it is shown that this difference is caused by the systematic and random noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A study of beam position diagnostics using beam-excited dipole modes in third harmonic superconducting accelerating cavities at a free-electron laser

We investigate the feasibility of beam position diagnostics using higher order mode (HOM) signals excited by an electron beam in the third harmonic 3.9 GHz superconducting accelerating cavities at FLASH. After careful theoretical and experimental assessment of the HOM spectrum, three modal choices have been narrowed down to fulfill different diagnostics requirements. These are localized dipole beam-pipe modes, trapped cavity modes from the fifth dipole band, and propagating modes from the first two dipole bands. These modes are treated with various data analysis techniques: modal identification, direct linear regression (DLR), and singular value decomposition (SVD). Promising options for beam diagnostics are found from all three modal choices. This constitutes the first prediction, subsequently confirmed by experiments, of trapped HOMs in third harmonic cavities, and also the first direct comparison of DLR and SVD in the analysis of HOM-based beam diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A REFINED QSO SELECTION METHOD USING DIAGNOSTICS TESTS: 663 QSO CANDIDATES IN THE LARGE MAGELLANIC CLOUD

We present 663 QSO candidates in the Large Magellanic Cloud (LMC) selected using multiple diagnostics. We started with a set of 2566 QSO candidates selected using the methodology presented in our previous work based on time variability of the MACHO LMC light curves. We then obtained additional information for the candidates by crossmatching them with the Spitzer SAGE, the Two Micron All Sky Survey, the Chandra, the XMM, and an LMC UBVI catalog. Using this information, we specified six diagnostic features based on mid-IR colors, photometric redshifts using spectral energy distribution template fitting, and X-ray luminosities in order to further discriminate high-confidence QSO candidates in the absence of spectra information. We then trained a one-class Support Vector Machine model using the diagnostics features of the confirmed 58 MACHO QSOs. We applied the trained model to the original candidates and finally selected 663 high-confidence QSO candidates. Furthermore, we crossmatched these 663 QSO candidates with the newly confirmed 151 QSOs and 275 non-QSOs in the LMC fields. On the basis of the counterpart analysis, we found that the false positive rate is less than 1%.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical experiment to estimate the validity of negative ion diagnostic using photo-detachment combined with Langmuir probing

This paper presents a critical assessment of the theory of photo-detachment diagnostic method used to probe the negative ion density and electronegativity α = n{sub -}/n{sub e}. In this method, a laser pulse is used to photo-detach all negative ions located within the electropositive channel (laser spot region). The negative ion density is estimated based on the assumption that the increase of the current collected by an electrostatic probe biased positively to the plasma is a result of only the creation of photo-detached electrons. In parallel, the background electron density and temperature are considered as constants during this diagnostics. While the numerical experiments performed here show that the background electron density and temperature increase due to the formation of an electrostatic potential barrier around the electropositive channel. The time scale of potential barrier rise is about 2 ns, which is comparable to the time required to completely photo-detach the negative ions in the electropositive channel (∼3 ns). We find that neglecting the effect of the potential barrier on the background plasma leads to an erroneous determination of the negative ion density. Moreover, the background electron velocity distribution function within the electropositive channel is not Maxwellian. This is due to the acceleration of these electrons through the electrostatic potential barrier. In this work, the validity of the photo-detachment diagnostic assumptions is questioned and our results illustrate the weakness of these assumptions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-color pyrometry based flame to fuel surface radiative heat flux diagnostic using flamelets

In this study, a non-intrusive two-color pyrometry based radiative heat flux diagnostic is presented that accounts for the self-absorption effects. This diagnostic relies on looking up the flame temperature and soot volume fraction using the ratio of color intensities obtained from digital cameras and numerical solutions of 1D steady-state diffusion flames. Virtual two color pyrometry of computed flame show a unique one-to-one mapping of strained flames with intensity ratio; thereby allowing flames to be indexed and creation of a two-color flamelet manifold (TCFM). The TCFM is a function of two variables; the ratio of red to green intensities (flame index) and physical distance to the stoichiometric surface defined using a level-set function. The developed diagnostic is used in upward flame spread experiments where an approximate flame hull reconstruction method is applied to provide the 3D level-set function and intensity ratio for use of TCFM to provide radiative absorption properties for 3D ray tracing. Accounting for self- absorption effects provide improved soot volume fraction estimates. In conclusion, the radiative heat flux estimates are found to be in very good agreement with literature and improved results are obtained near the flame base.

42 ENGINEERING↗

Noninvasive Detection, Tracking, and Characterization of Aerogel Implants Using Diagnostic Ultrasound

Medical implants are routinely tracked and monitored using different techniques, such as MRI, X-ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non-invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of information about the implants and the surrounding structures, this paper describes the development and study of two simple B-Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels.

36 MATERIALS SCIENCE↗

Electron Beam Diagnostics using Coherent Cherenkov Radiation in Aerogel

The use of coherent Cherenkov radiation as a diagnostic tool for longitudinal distribution of an electron beam is studied in this paper. Coherent Cherenkov radiation is produced in an aerogel with an index of refraction close to unity. An aerogel spectral properties are experimentally studied and analyzed. This method will be employed for the helical IFEL bunching experiment at Neptune linear accelerator facility at UCLA.

43 PARTICLE ACCELERATORS↗

NEW SOLAR WIND DIAGNOSTIC USING BOTH IN SITU AND SPECTROSCOPIC MEASUREMENTS

We develop a new diagnostic technique that utilizes, at the same time, two completely different types of observations-in situ determinations of solar wind charge states and high-resolution spectroscopy of the inner solar corona-in order to study the temperature, density, and velocity of the solar wind as a function of height in the inner corona below the plasma freeze-in point. This technique relies on the ability to calculate the evolution of the ion charge composition as the solar wind escapes the Sun given the wind temperature, density, and velocity profiles as a function of distance. The resulting charge state composition can be used to predict frozen-in charge states as well as spectral line intensities. The predicted spectra and ion charge compositions can be compared with observations carried out when spectrometers and in situ instruments are in quadrature configuration to quantitatively test a set of assumptions regarding density, temperature, and velocity profiles in the low corona. Such a comparison can be used in two ways. If the input profiles are predicted by a theoretical solar wind model, this technique allows the benchmarking of the model. Otherwise, an empirical determination of the velocity, temperature, and density profiles can be achieved below the plasma freeze-in point applying a trial-and-error procedure to initial, user-specified profiles. To demonstrate this methodology, we have applied this technique to a state-of-the-art coronal hole and equatorial streamer model.

79 ASTRONOMY AND ASTROPHYSICS↗

Time dependent analysis of visible helium line-ratios for electron temperature and density diagnostic using synthetic simulations on NSTX-U

Helium line-ratios for electron temperature (Te) and density (ne) plasma diagnostic in the Scrape-Off-Layer (SOL) and Edge regions of tokamaks are widely used. Due to their intensities and proximity of wavelengths, the singlet 667.8 and 728.1 nm, and triplet 706.5 nm visible lines have been typically preferred. Time- dependency of the triplet line (706.5 nm) has been previously analyzed in detail by including transient effects on line-ratios during gas-puff diagnostic applications. In this work, several line-ratio combinations within each of the two spin systems are analyzed with the purpose of eliminating transient effects to extend the application of this powerful diagnostic to high temporal resolution characterization of plasmas. The analysis is done using synthetic emission modeling and diagnostic for low electron density NSTX SOL plasma conditions for several visible lines. This analysis employs both quasi-static equilibrium and time-dependent models in order to evaluate transient effects of the atomic population levels that may affect the derived electron temperatures and densities as a helium gas-puff penetrates the plasma. Ratios between the most intense lines are usually preferred due to their higher signal to noise ratio. The analysis of a wider range of spectral lines will help to extend this powerful diagnostic to experiments where the wavelength range of the measured spectra may be constrained either by limitations of the spectrometer, or by other conflicting lines from different ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fracture Diagnostics Using Low Frequency Electromagnetic Induction and Electrically Conductive Proppants

The monitoring and diagnostics of induced fractures are important for the real-time performance evaluation of hydraulic fracturing operations. Previous electromagnetic (EM) based studies show that single backbone tri-axial induction logging tools are promising candidates for real-time monitoring and diagnosis of fractures in open-hole wells. To support the development of field deployable tools, the concept must be tested in experiments, in a controllable environment, before it is tested under field-like conditions. To this end, we have developed numerical tools which can simulate any wellbore environment while logging hydraulic fractures with the induction tool. We have designed and built a prototype induction tool and performed two sets of tests to compare with numerical simulation results. The computational and experimental setup consists of tri-axial transmitter- and receiver-coils in co-axial, co-planar and cross-polarized configurations. Both lab and shallow earth measurements are shown to be in good agreement with simulations for all examined cases. The average relative and maximum discrepancies of the measured signals from the simulated ones were lower than 3% and 10%, respectively. With the prototype tool, strong signals sensitive to the fracture’s surface area and dip-angle were measured in co-axial coil configuration, while weaker signals sensitive to the fracture’s aspect ratio were observed in the co-planar configuration. Cross-polarized signals are also shown to be strong and sensitive to the fracture’s dip. Lastly, we resolved the detectable components of the signal tensor to obtain parameters of simplified fracture geometries. The inversion algorithm, a derivative free directional search model, uses an objective function defined as a combination of co-axial and cross-polarized signals from different tool spacings to provide a well behaved global minimum. The robustness of inversion algorithm is tested on synthetic data for single cluster fractures in homogeneous and heterogeneous background electrical conductivity. All the effective model parameters for different cases, fracture conductivity (width), propped area (length) and dip-angle, are shown to be recovered with sufficient accuracy. We also evaluated the effect of multiple neighboring fractures and suggested a multi-cluster inversion algorithm that can accurately recover the proppant distribution in each fracture. Based on these results we provide a downhole tool design, with detailed specifications, that can effectively recover far-field proppant distribution in hydraulic fractures.

02 PETROLEUM↗

A new method of out-of-focus millimeter wave imaging in fusion plasma diagnostics using Bessel beams

Electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry diagnostics have been employed on a number of magnetic fusion plasma confinement devices. The common approach is based on a Gaussian beam assumption, which generates good spatial resolution (centimeter level). However, the radial focal depth is limited by the poloidal resolution, which is comparable with the Rayleigh length (~150 mm). By contrast, a new Bessel beam approach has been developed and demonstrated to generate much longer focal depth with the property of propagation stability. To test the new approach, the DIII-D tokamak LCP ECEI optics have been re-designed to support a Bessel beam approach based on an axicon lens. The achievable radial coverage can exceed that of the current Gaussian approach by 3×. Finally, the imaging result is discussed in this paper based on the simulation analysis and laboratory testing result.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluate the impact of sensor accuracy on model performance in data-driven building fault detection and diagnostics using Monte Carlo simulation

The performance of data-driven fault detection and diagnostics (FDD) is heavily dependent on sensors. However, sensor inaccuracy and sensor faults are pervasive in building operation: inaccurate and missing sensor readings deteriorate FDD performance; sensor inaccuracy will also affect the selection of sensor for data-driven FDD in the model training process, which is another key factor of data-driven FDD performance. Sensor accuracy and sensor selection individually are well-studied research topics in this field, but the impact of sensor accuracy on sensor selection and its further impact on FDD performance has not been evaluated and quantified. In this paper, we developed a novel analysis methodology that comprehensively evaluates sensor fault on sensor selection and FDD accuracy. Monte Carlo simulation is applied to deal with multiple stochastic sensor inaccuracy and provide probabilistic analysis results of the impact of sensor inaccuracy on sensor selection and FDD accuracy. This methodology focuses on the net impact of fault states across a full sensor set. The developed methodology can be used for the early-stage sensor design and operation-stage sensor maintenance. Furthermore, a case study is conducted to demonstrate the analysis methodology using a commercial building model crated to Flexible Research Platform located at Oak Ridge National Laboratory, USA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HELIOS: A helium line-ratio spectral-monitoring diagnostic used to generate high resolution profiles near the ion cyclotron resonant heating antenna on TEXTOR

Radial profiles of electron temperature and density are measured at high spatial ({approx}1 mm) and temporal ( Greater-Than-Or-Slanted-Equal-To 10 {mu}s) resolution using a thermal supersonic helium jet. A highly accurate detection system is applied to well-developed collisional-radiative model codes to produce the profiles. Agreement between this measurement and an edge Thomson scattering measurement is found to be within the error bars ( Less-Than-Or-Equivalent-To 20%). The diagnostic is being used to give profiles near the ion cyclotron resonant heating antenna on TEXTOR to better understand RF coupling to the core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗