Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DAILY VARIATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Main components of PM10 in an area influenced by a cement plant in Catalonia, Spain: Seasonal and daily variations

Highlights: • Constituents and main components of airborne PM{sub 10} near a cement plant were studied. • A clear seasonality was found, with higher levels in winter. • A daily pattern was not observed, when comparing weekdays and weekends. • Road traffic had a significant contribution to PM{sub 10} levels. Particulate matter (PM) composition has a key role in a wide range of health outcomes, such as asthma, chronic obstructive pulmonary disease, lung cancer, cardiovascular disease, and death, among others. Montcada i Reixac, a municipality located in the Barcelona metropolitan area (Catalonia, Spain), for its location and orography, is an interesting case- study to investigate air pollution. The area is also characterized by the presence of different industrial emission sources, including a cement factory and a large waste management plant, as well as an intense traffic. In this study, PM{sub 10} levels, trace elements, ions, and carbonaceous particles were determined for a long time period (2013–2016) in this highly polluted area. PM{sub 10} samples were collected during six consecutive days in two campaigns (cold and warm) per year. A number of elements (As, Ba, Be, Bi, Ca, Cd, Ce, Co, Cr, Cs, Cu, Dy, Er, Eu, Fe, Ga, Gd, Ge, Hf, Hg, Ho, K, La, Li, Hg, Mg, Mn, Mo, Nb, Nd, Ni, Pb, Pr, Rb, Sb, Sc, Se, Sm, Sn, Sr, Tb, Th, Ti, Tl, U, V, W, Y, Yb, and Zr), ions (Cl{sup -}, SO{sub 4}{sup 2-}, NO{sub 3}{sup -}, and NH{sub 4}{sup +}), and carbonaceous content (total carbon, organic plus elemental carbon, and CO{sub 3}{sup 2-}), were analysed. These data were used to identify the PM{sub 10} main components: mineral matter, sea spray, secondary inorganic aerosols, organic matter plus elemental carbon, trace elements or indeterminate fraction. Although a clear seasonality (cold vs. warm periods) was found, there were no differences between working days and weekends. Obviously, the cement plant influences the surrounding environment. However, no differences in trace elements related with the cement plant activity (Al, Ca, Ni and V) between weekdays and weekends were noted. However, some traffic-related elements (i.e., Co, Cr, Mn, and Sb) showed significantly higher concentrations in weekdays.

54 ENVIRONMENTAL SCIENCES↗

Assessing Energy Impact of Plug-In Hybrid Electric Vehicles: Significance of Daily Distance Variation over Time and Among Drivers

Accurate assessment of the impact of plug-in hybrid electric vehicles (PHEVs) on petroleum and electricity consumption is a necessary step toward effective policies. Variations in daily vehicle miles traveled (VMT) over time and among drivers affect PHEV energy impact, but the significance is not well understood. This paper uses a graphical illustration, a mathematical derivation, and an empirical study to examine the cause and significance of such an effect. The first two methods reveal that ignoring daily variation in VMT always causes underestimation of petroleum consumption and overestimation of electricity consumption by PHEVs; both biases increase as the assumed PHEV charge-depleting (CD) range moves closer to the average daily VMT. The empirical analysis based on national travel survey data shows that the assumption of uniform daily VMT over time and among drivers causes nearly 68% underestimation of expected petroleum use and nearly 48% overestimation of expected electricity use by PHEVs with a 40-mi CD range (PHEV40s). Also for PHEV40s, consideration of daily variation in VMT over time but not among drivers similar to the way the utility factor curve is derived in SAE Standard SAE J2841 causes underestimation of expected petroleum use by more than 24% and overestimation of expected electricity use by about 17%. Underestimation of petroleum use and overestimation of electricity use increase with larger-battery PHEVs.

02 PETROLEUM↗

Poster - 33: Dosimetry Comparison of Prone Breast Forward and Inverse Treatment planning considering daily setup variations

Introduction: The purpose of this study is to investigate the effects of daily setup variations on prone breast forward field-in-field (FinF) and inverse IMRT treatment planning. Methods: Rando Phantom (Left breast) and Pixy phantom (Right breast) were built and CT scanned in prone position. The treatment planning (TP) is performed in Eclipse TP system. Forward FinF plan and inverse IMRT plan were created to satisfy the CTV coverage and OARs criteria. The daily setup variations were assumed to be 5 mm at left-right, superior-inferior, and anterior-posterior directions. The DVHs of CTV coverage and OARs were compared for both forward FinF plan and inverse IMRT plans due to 5mm setup variation. Results and Discussions: DVHs of CTV coverage had fewer variations for 5m setup variation for forward FinF and inverse IMRT plan for both phantoms. However, for the setup variations in the left-right direction, the DVH of CTV coverage of IMRT plan showed the worst variation due to lateral setup variation for both phantoms. For anterior-posterior variation, the CTV could not get full coverage when the breast chest wall is shallow; however, with the guidance of MV imaging, breast chest wall will be checked during the MV imaging setup. So the setup variations have more effects on inverse IMRT plan, compared to forward FinF plan, especially in the left-right direction. Conclusions: The Forward FinF plan was recommended clinically considering daily setup variation.

60 APPLIED LIFE SCIENCES↗

Influence of glucocorticoids on time-of-day-dependent variations in IgE-, histamine-, and platelet-activating factor-mediated systemic anaphylaxis in different mouse strains

Highlights: • Daily variations in systemic anaphylaxis differed among inbred mouse strains. • The daily variations differed with anaphylaxis-inducing substances. • Glucocorticoid-dependent and -independent mechanisms regulated the variations. A time-of-day-dependent variation in IgE-mediated passive systemic anaphylaxis was previously reported in ICR mice. In the present study, we investigated time-of-day-dependent variations in IgE-, histamine-, and platelet-activating factor (PAF)-mediated systemic anaphylaxis in C57BL/6, BALB/c, and NC/Nga mice at 9:00 h and 21:00 h, and evaluated the potential influence of glucocorticoids (GCs) on these variations. We found significant time-of-day-dependent variations in IgE-mediated systemic anaphylaxis in C57BL/6 mice, and in histamine- and PAF-mediated systemic anaphylaxis in BALB/c mice. Significant daily variations in IgE-, histamine-, and PAF-mediated systemic anaphylaxis were not observed in NC/Nga mice. Pretreatment with dexamethasone and adrenalectomy abolished the daily variations in IgE-mediated systemic anaphylaxis in C57BL/6 mice and in PAF-mediated systemic anaphylaxis in BALB/c mice, suggesting that GCs from adrenal glands are pivotal in regulating these variations. In contrast, pretreatment with dexamethasone and adrenalectomy did not abolish the daily variation in histamine-mediated systemic anaphylaxis in BALB/c mice, suggesting that GC-independent and adrenal gland-independent mechanisms are important for the variation. The present study demonstrated that time-of-day-dependent variations in systemic anaphylaxis differed among inbred mouse strains and with anaphylaxis-inducing substances. Thus, mouse strains, time of experiment, and anaphylaxis-inducing substances used must be considered to obtain appropriate experimental results.

60 APPLIED LIFE SCIENCES↗

SU-E-T-62: A Preliminary Experience of Using EPID Transit Dosimetry for Monitoring Daily Dose Variations in Radiation Treatment Delivery

Purpose: To investigate the use of EPID transit dosimetry for monitoring daily dose variations in radiation treatment delivery. Methods: A patient with head and neck cancer treated using nine field IMRT beams was used in this study. The prescription was 45 Gy in 25 fractions. A KV CBCT was acquired before each treatment on a Varian NTX linear accelerator. Integrated images using MV EPID were acquired for each treatment beam. Planning CT images, treatment plan, and daily integrated images were imported into a commercial QA software Dosimetry Check (v4r4 Math Resolutions, LLC, Columbia, MD) to calculate 3D dose of the day assuming 25 fractions treatment. Planning CT images were deformed and registered to each daily CBCT using Varian SmartAdapt (v11.MR2). ROIs were then propagated from planning CT to daily CBCT. The correlation between maximum, average dose of ROIs and ROI volume, center of mass shift, Dice Similarity Coefficient (DSC) were investigated. Results: Not all parameters investigated showed strong correlations. For PTV and CTV, the average dose has inverse correlation with their volume change (correlation coefficient −0.52, −0.50, respectively) and DSC (−0.59, −0.59, respectively). The average dose of right parotid has correlation with its volume change (0.56). The maximum dose of spinal cord has correlation with the center of mass superior-inferior shift (0.52) and inverse correlation with the center of mass anterior-posterior shift (−0.73). Conclusion: Transit dosimetry using EPID images collected during treatment delivery offers great potential to monitor daily dose variations due to patient anatomy change, motion, and setup errors in radiation treatment delivery. It can provide a patient-specific QA tool valuable for adaptive radiation therapy. Further work is needed to validate the technique.

60 APPLIED LIFE SCIENCES↗

Search for Variations of {sup 213}Po Half-Life

A device with the parent {sup 229}Th source was constructed to search for variations of the daughter {sup 213}Po half-life (T{sub 1/2} = 4.2 μs). A solar-daily variation with amplitude A{sub So} = (5.3 ± 1.1) × 10{sup –4}, a lunar-daily variation with amplitude A{sub L} = (4.8 ± 2.1) × 10{sup –4}, and a sidereal-daily variation with amplitude A{sub S} = (4.2 ± 1.7) × 10{sup –4} were found upon proceeding the data series over a 622-day interval (from July 2015 to March 2017). The {sup 213}Po half-life mean value is found to be T{sub 1/2} = 3.705 ± 0.001 μs. The reference value is corrected by 12%.

07 ISOTOPE AND RADIATION SOURCES↗

Results of a search for daily and annual variations of the {sup 214}Po half-life at the two year observation period

The brief description of installation TAU-2 intended for long-term monitoring of the half-life value τ(T{sub 1/2}) of the {sup 214}Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values of τ with different time step are presented. Total measurement time was equal to 590 days. Averaged value of the {sup 214}Po half-life was obtained τ = 163.46 ± 0.04 μs. The annual variation with an amplitude A = (8.9 ± 2.3) × 10{sup −4}, solar-daily variation with an amplitude A{sub So} = (7.5 ± 1.2) × 10{sup −4}, lunar-daily variation with an amplitude A{sub L} = (6.9 ± 2.0) × 10{sup −4} sidereal-daily variation with an amplitude A{sub S} = (7.2 ± 1.2) × 10{sup −4} were found in a series of τ values. The maximal values of amplitude are observed at the moments when the projections of the installation Earth location velocity vectors toward the source of possible variation achieve its maximal magnitudes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy

Purpose: To quantify interfractional anatomic variations and limitations of the current practice of image-guided radiation therapy (IGRT) for prostate-bed patients and to study dosimetric benefits of an online adaptive replanning scheme that addresses the interfractional variations. Methods: Contours for the targets and organs at risk (OARs) from daily diagnostic-quality CTs acquired with in-room CT (CTVision, Siemens) were generated by populating the planning contours using an autosegmentation tool based on deformable registration (ABAS, Elekta) with manual editing for ten prostate-bed patients treated with postoperative daily CT-guided IMRT. Dice similarity coefficient (DSC) obtained by maximizing the overlap of contours for a structure between the daily and plan contours was used to quantify the organ deformation between the plan and daily CTs. Three interfractional-variation-correction schemes, the current standard practice of IGRT repositioning, a previously developed online adaptive RT (ART), and the full reoptimization, were applied to these daily CTs and a number of dose-volume quantities for the targets and organs at risk were compared for their effectiveness to account for the interfractional variations. Results: Large interfractional organ deformations in prostate-bed irradiation were seen. The mean DSCs for CTV, rectum, and bladder were 86.6 ± 5.1% (range from 61% to 97%), 77.3% ± 7.4% (range from 55% to 90%), and 75.4% ± 11.2% (range from 46% to 96%), respectively. The fractional and cumulative dose-volume quantities for CTV and PTV: V100 (volume received at least 100% prescription dose), and rectum and bladder: V{sub 45Gy} and V{sub 60Gy} (volume received at least 45 or 60 Gy), were compared for the repositioning, adaptive, reoptimization, and original plans. The fractional and cumulative dosimetric results were nearly the same. The average cumulative CTV V100 were 88.0%, 98.4%, 99.2%, and 99.3% for the IGRT, ART, reoptimization, and original plans, respectively. The corresponding rectal V{sub 45Gy} (V{sub 60Gy}) were 58.7% (27.3%), 48.1% (20.7%), 43.8% (16.1%), and 44.9% (16.8%). The results for bladder were comparable among three schemes. Paired two-tailed Wilcoxon signed-rank tests were performed and it was found that ART and reoptimization provide better target coverage and better OAR sparing, especially rectum sparing. Conclusions: The interfractional organ motions and deformations during prostate-bed irradiation are significant. The online adaptive replanning scheme is capable of effectively addressing the large organ deformation, resulting in cumulative doses equivalent to those originally planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Variations in the Setup of Pelvic Bony Anatomy and Soft Tissue, and Their Implications on the Delivery of Proton Therapy for Localized Prostate Cancer

Purpose: To quantify daily variations in the anatomy of patients undergoing radiation therapy for prostate carcinoma, to estimate their effect on dose distribution, and to evaluate the effectiveness of current standard planning and setup approaches employed in proton therapy. Methods: We used series of computed tomography data, which included the pretreatment scan, and between 21 and 43 in-room scans acquired on different treatment days, from 10 patients treated with intensity-modulated radiation therapy at Morristown Memorial Hospital. Variations in femur rotation angles, thickness of subcutaneous adipose tissue, and physical depth to the distal surface of the prostate for lateral beam arrangement were recorded. Proton dose distributions were planned with the standard approach. Daily variations in the location of the prescription isodose were evaluated. Results: In all 10 datasets, substantial variation was observed in the lateral tissue thickness (standard deviation of 1.7-3.6 mm for individual patients, variations of >5 mm from the planning computed tomography observed in all series), and femur rotation angle (standard deviation between 1.3{sup o} and 4.8{sup o}, with the maximum excursion exceeding 10{sup o} in 6 of 10 datasets). Shifts in the position of treated volume (98% isodose) were correlated with the variations in the lateral tissue thickness. Conclusions: Analysis suggests that, combined with image-guided setup verification, the range compensator expansion technique prevents loss of dose to target from femur rotation and soft-tissue deformation, in the majority of cases. Anatomic changes coupled with the uncertainties of particle penetration in tissue restrict possibilities for margin reduction in proton therapy of prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Observation of daily and annular variations in the {sup 214}Po half-life

Results: of the analysis of a time series of values of the half-life (τ) of the {sup 214}Po nucleus with a different time step obtained from the TAU-1 (354 days) and TAU-2 (973 days) installations are presented. The annual variation with an amplitude of (9.8 ± 0.6) × 10{sup −4} and daily variations in the solar, lunar, and sidereal times with amplitudes of (5.3 ± 0.3) × 10{sup −4}, (6.9 ± 2.0) × 10{sup −4}, and (7.2 ± 1.2) × 10{sup −4}, respectively, are found in the series of τ values. It is shown that variations in microclimatic parameters cannot be a cause of τ variations.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of Daily Setup Variation With Tomotherapy Megavoltage Computed Tomography

The purpose of this study was to evaluate different setup uncertainties for various anatomic sites with TomoTherapy (registered) pretreatment megavoltage computed tomography (MVCT) and to provide optimal margin guidelines for these anatomic sites. Ninety-two patients with tumors in head and neck (HN), brain, lung, abdominal, or prostate regions were included in the study. MVCT was used to verify patient position and tumor target localization before each treatment. With the anatomy registration tool, MVCT provided real-time tumor shift coordinates relative to the positions where the simulation CT was performed. Thermoplastic facemasks were used for HN and brain treatments. Vac-Lok{sup TM} cushions were used to immobilize the lower extremities up to the thighs for prostate patients. No respiration suppression was administered for lung and abdomen patients. The interfractional setup variations were recorded and corrected before treatment. The mean interfractional setup error was the smallest for HN among the 5 sites analyzed. The average 3D displacement in lateral, longitudinal, and vertical directions for the 5 sites ranged from 2.2-7.7 mm for HN and lung, respectively. The largest movement in the lung was 2.0 cm in the longitudinal direction, with a mean error of 6.0 mm and standard deviation of 4.8 mm. The mean interfractional rotation variation was small and ranged from 0.2-0.5 deg., with the standard deviation ranging from 0.7-0.9 deg. Internal organ displacement was also investigated with a posttreatment MVCT scan for HN, lung, abdomen, and prostate patients. The maximum 3D intrafractional displacement across all sites was less than 4.5 mm. The interfractional systematic errors and random errors were analyzed and the suggested margins for HN, brain, prostate, abdomen, and lung in the lateral, longitudinal, and vertical directions were between 4.2 and 8.2 mm, 5.0 mm and 12.0 mm, and 1.5 mm and 6.8 mm, respectively. We suggest that TomoTherapy (registered) pretreatment MVCT can be used to improve the accuracy of patient positioning and reduce tumor margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DIURNAL AND ANNUAL VARIATIONS OF DIRECTIONAL DETECTION RATES OF DARK MATTER

Direction-sensitive direct detection of weakly interacting massive particles (WIMPs) as dark matter would provide an unambiguous non-gravitational signature of dark matter. The diurnal variation of dark matter signal due to Earth's rotation around its own axis can be a significant signature for Galactic WIMPs. Because of a particular orientation of Earth's axis of rotation with respect to the WIMP wind direction, the apparent direction of WIMP wind as observed at a detector can alter widely in a day. In this work, we calculate the directional detection rates with their daily and yearly modulations in Earth-bound dark matter experiments considering detailed features of the geometry and dynamics of the Earth-Sun system along with the solar motion in a Galactic frame. A separate halo model, namely the dark disk model other than the usual standard halo model for dark matter halo, is also considered and the results for two models are compared. We demonstrate the results for two types of gas detectors, namely DRIFT (target material CS{sub 2}) and NEWAGE (target material CF{sub 4}), which use Time Projection Chamber techniques for measuring directionality of the recoil nucleus. The WIMP mass and recoil energy dependence of the daily variation of event rates are computed for a specific detector, and the sensitive ranges of mass and recoil energies for the considered detector are probed.

79 ASTRONOMY AND ASTROPHYSICS↗

ASTROMETRIC JITTER OF THE SUN AS A STAR

The daily variation of the solar photocenter over some 11 yr is derived from the Mount Wilson data reprocessed by Ulrich et al. to closely match the surface distribution of solar irradiance. The standard deviations of astrometric jitter are 0.52 {mu}AU and 0.39 {mu}AU in the equatorial and the axial dimensions, respectively. The overall dispersion is strongly correlated with solar cycle, reaching 0.91 {mu}AU at maximum activity in 2000. The largest short-term deviations from the running average (up to 2.6 {mu}AU) occur when a group of large spots happen to lie on one side with respect to the center of the disk. The amplitude spectrum of the photocenter variations never exceeds 0.033 {mu}AU for the range of periods 0.6-1.4 yr, corresponding to the orbital periods of planets in the habitable zone. Astrometric detection of Earth-like planets around stars as quiet as the Sun is not affected by star spot noise, but the prospects for more active stars may be limited to giant planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Calif. ISO gears up for growing renewables portfolio

Operating the grid is going to become more of a challenge as wind and solar generation -- the biggest two contributors with the most hourly and daily variations -- grow over time. Forecasting exactly how much capacity will be available a mere one hour ahead still remains difficult. More renewable generation is not good business for conventional peaking and load-following thermal generation, mostly burning natural gas. Their revenues, depending on the specific scenario considered, may drop by 20 to 40 percent. Something has to be done to sustain these critical players even as their output is not required as much as in the past.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-G-JeP1-06: Correlation of Lung Tumor Motion with Tumor Location Using Electromagnetic Tracking

Purpose: It is well known that lung tumors move with respiration. However, most measurements of lung tumor motion have studied long treatment times with intermittent imaging; those populations may not necessarily represent conventional LINAC patients. We summarized the correlation between tumor motion and location in a multi-institutional trial with electromagnetic tracking, and identified the patient cohort that would most benefit from respiratory gating. Methods: Continuous electromagnetic transponder data (Varian Medical, Seattle, WA) of lung tumor motion was collected from 14 patients (214 total fractions) across 3 institutions during external beam radiation therapy in a prospective clinical trial (NCT01396551). External intervention from the clinician, such as couch shifts, instructed breath-holds, and acquisition pauses, were manually removed from the 10 Hz tracking data according to recorded notes. The average three-dimensional displacement from the breathing cycle’s end-expiratory to end-inhalation phases (peak-to-peak distance) of the transponders’ isocenter was calculated for each patient’s treatment. A weighted average of each isocenter was used to assess the effects of location on motion. A total of 14 patients were included in this analysis, grouped by their transponders’ location in the lung: upper, medial, and lower. Results: 8 patients had transponders in the upper lung, and 3 patients each in the medial lobe and lower lung. The weighted average ± standard deviation of all peak-to-peak distances for each group was: 1.04 ± 0.39 cm in the lower lung, 0.56 ± 0.14 cm in the medial lung, and 0.30 ± 0.06 cm in the upper lung. Conclusion: Tumors in the lower lung are most susceptible to excessive motion and daily variation, and would benefit most from continuous motion tracking and gating. Those in the medial lobe might be at moderate risk. The upper lobes have limited motion. These results can guide different motion management strategies between lung tumor locations. This is part of an NIH-funded prospective clinical trial (NCT01396551), using an electromagnetic transponder tracking system and additional funding from Varian Medical (Seattle, WA).

60 APPLIED LIFE SCIENCES↗

Contribution of sewage to occurrence of phosphodiesterase-5 inhibitors in natural water

Phosphodiesterase-5 inhibitors (PDE-5i, such as Sildenafil, Tadalafil and Vardenafil, mainly prescribed to treat erectile dysfunction) and their generic drug equivalents have been widely marketed and consumed in Korea. From the concentrations detected in wastewater, we could deduce that relatively large amounts of PDE-5i were consumed without a legal prescription. Thus, PDE-5i’s presence in the environment via sewage is unavoidable, and their environmental fate within a sewage treatment plant (STP) should be evaluated. In this study, we investigated the occurrence of three PDE-5i analogs in the influent and effluent of two STPs and the receiving water bodies. The PDE-5i concentration in total reached 62 ± 12 (STP#1) and 88 ± 37 ng L -1 (STP#2) in the sewage influent; about 70% of it was Sildenafil in both STPs. However, they were hardly removed by the STPs as the removal efficiency of the STPs was less than 10% ± 5%. Therefore, the pharmaceuticals were detected in the receiving water (lower than 7 ng L -1 as a total amount) and the concentration slightly increased downstream of the STPs. A simple mass balance model applied for the compounds in the STP effluent and receiving water bodies also confirmed that the discharged PDE-5i were quite persistent. Lastly, we identified temporal and regional patterns in the consumption of the drugs from daily variations of PDE-5i in the influent to these two STPs. For instance, the levels of PDE-5i in the sewage significantly increased on weekends (from Friday to Saturday), and especially in the area where adult-entertainment businesses are common. We estimated that the amount of PDE-5i consumption in this area was 31% higher than that in the area with fewer nightlife spots. Considering that they are pharmaceutically active and resistant to treatment processes within an STP, it is advised that a regular monitoring and management program for PDE-5i should be developed to prevent the discharge of the pharmaceuticals into the water environment.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-129: Are Knowledge-Based Planning Dose Estimates Valid for Distensible Organs?

Purpose: Knowledge-based planning programs have become available to assist treatment planning in radiation therapy. Such programs can be used to generate estimated DVHs and planning constraints for organs at risk (OARs), based upon a model generated from previous plans. These estimates are based upon the planning CT scan. However, for distensible OARs like the bladder and rectum, daily variations in volume may make the dose estimates invalid. The purpose of this study is to determine whether knowledge-based DVH dose estimates may be valid for distensible OARs. Methods: The Varian RapidPlan™ knowledge-based planning module was used to generate OAR dose estimates and planning objectives for 10 prostate cases previously planned with VMAT, and final plans were calculated for each. Five weekly setup CBCT scans of each patient were then downloaded and contoured (assuming no change in size and shape of the target volume), and rectum and bladder DVHs were recalculated for each scan. Dose volumes were then compared at 75, 60,and 40 Gy for the bladder and rectum between the planning scan and the CBCTs. Results: Plan doses and estimates matched well at all dose points., Volumes of the rectum and bladder varied widely between planning CT and the CBCTs, ranging from 0.46 to 2.42 for the bladder and 0.71 to 2.18 for the rectum, causing relative dose volumes to vary between planning CT and CBCT, but absolute dose volumes were more consistent. The overall ratio of CBCT/plan dose volumes was 1.02 ±0.27 for rectum and 0.98 ±0.20 for bladder in these patients. Conclusion: Knowledge-based planning dose volume estimates for distensible OARs are still valid, in absolute volume terms, between treatment planning scans and CBCT’s taken during daily treatment. Further analysis of the data is being undertaken to determine how differences depend upon rectum and bladder filling state. This work has been supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗