Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DAILY SHOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Brief: Daily Performance Changes in Metal Halide Perovskite PV Modules

Metal halide perovskite photovoltaic modules deployed outdoors and held at their maximum power point show daily, reversible, relative changes of up to 30% in efficiency between morning and afternoon. Predicting energy yield and quantifying reliability will require properly handling such daily performance changes.

14 SOLAR ENERGY↗

SU-E-T-89: Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform

Purpose: Use of Small Animal Radiation Research Platform (SARRP) systems for conducting state-of-the-art image guided radiotherapy (IGRT) research on small animals has become more common over the past years. The purpose of this work is to develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the SARRP. Methods: A QA phantom was developed for carrying out daily, monthly and annual QA tasks including imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of nine (60×60×5 mm3) KV-energy tissue equivalent solid water slabs that can be employed for annual dosimetry QA with film. Three of the top slabs are replaceable with ones incorporating Mosfets or OSLDs arranged in a quincunx pattern, or a slab drilled to accommodate an ion chamber insert. These top slabs are designed to facilitate routine daily and monthly QA tasks such as output constancy, isocenter congruency test, treatment planning system (TPS) QA, etc. One slab is designed with inserts for image QA. A prototype of the phantom was applied to test the performance of the imaging, planning and treatment delivery systems. Results: Output constancy test results showed daily variations within 3%. For isocenter congruency test, the phantom could be used to detect 0.3 mm deviations of the CBCT isocenter from the radiation isocenter. Using the Mosfet in phantom as target, the difference between TPS calculations and measurements was within 5%. Image-quality parameters could also be assessed in terms of geometric accuracy, CT number accuracy, linearity, noise and image uniformity, etc. Conclusion: The developed phantom can be employed as a simple tool for comprehensive performance evaluation of the SARRP. The study provides a reference for development of a comprehensive quality assurance program for the SARRP, with proposed tolerances and frequency of required tests.

07 ISOTOPE AND RADIATION SOURCES↗

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-J-214: Comparative Assessment On IGRT On Partial Bladder Cancer Treatment Between CT-On-Rails (CTOR) and KV Cone Beam CT (CBCT)

Purpose: Image-Guided radiation therapy(IGRT) depends on reliable online patient-specific anatomy information to address random and progressive anatomy changes. Large margins have been suggested to bladder cancer treatment due to large daily bladder anatomy variation. KV Cone beam CT(CBCT) has been used in IGRT localization prevalently; however, its lack of soft tissue contrast makes clinicians hesitate to perform daily soft tissue alignment with CBCT for partial bladder cancer treatment. This study compares the localization uncertainties of bladder cancer IGRT using CTon- Rails(CTOR) and CBCT. Methods: Three T2N0M0 bladder cancer patients (total of 66 Gy to partial bladder alone) were localized daily with either CTOR or CBCT for their entire treatment course. A total of 71 sets of CTOR and 22 sets of CBCT images were acquired and registered with original planning CT scans by radiation therapists and approved by radiation oncologists for the daily treatment. CTOR scanning entailed 2mm slice thickness, 0.98mm axial voxel size, 120kVp and 240mAs. CBCT used a half fan pelvis protocol from Varian OBI system with 2mm slice thickness, 0.98axial voxel size, 125kVp, and 680mAs. Daily localization distribution was compared. Accuracy of CTOR and CBCT on partial bladder alignment was also evaluated by comparing bladder PTV coverage. Results: 1cm all around PTV margins were used in every patient except target superior limit margin to 0mm due to bowel constraint. Daily shifts on CTOR averaged to 0.48, 0.24, 0.19 mms(SI,Lat,AP directions); CBCT averaged to 0.43, 0.09, 0.19 mms(SI,Lat,AP directions). The CTOR daily localization showed superior results of V100% of PTV(102% CTOR vs. 89% CBCT) and bowel(Dmax 69.5Gy vs. 78Gy CBCT). CTOR images showed much higher contrast on bladder PTV alignment. Conclusion: CTOR daily localization for IGRT is more dosimetrically beneficial for partial bladder cancer treatment than kV CBCT localization and provided better soft tissue PTV identification.

60 APPLIED LIFE SCIENCES↗

Field evidences for the positive effects of aerosols on tree growth

Theoretical and eddy-covariance studies demonstrate that aerosol-loading stimulates canopy photosynthesis, but field evidence for the aerosol effect on tree growth is limited. For this study, we measured in-situ daily stem growth rates of aspen trees under a wide range of aerosol-loading in China. The results showed that daily stem growth rates were positively correlated with aerosol-loading, even at exceptionally high aerosol levels. Using structural equation modelling analysis, we showed that variations in stem growth rates can be largely attributed to two environmental variables co-varying with aerosol loading: diffuse fraction of radiation and vapor pressure deficit (VPD). Furthermore, we found that these two factors influence stem growth by influencing photosynthesis from different parts of canopy. By using field observations and a mechanistic photosynthesis model, we demonstrate that photosynthetic rates of both sun and shade leaves increased under high aerosol-loading conditions but for different reasons. For sun leaves, the photosynthetic increase was primarily attributed to the concurrent lower VPD; for shade leaves, the positive aerosol effect was tightly connected with increased diffuse light. Overall, our study provides the first field-evidence of increased tree growth under high aerosol loading. We highlight the importance of understanding biophysical mechanisms of aerosol-meteorology interactions, and incorporating the different pathways of aerosol effects into earth system models to improve the prediction of large-scale aerosol impacts, and the associated vegetation-mediated climate feedbacks.

54 ENVIRONMENTAL SCIENCES↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Extreme Wet-Bulb Temperatures in China: The Significant Role of Moisture

This paper investigates the extreme wet bulb temperatures (TWs) in China, with a focus on understanding the relative contributions of temperature and moisture to the extremes. Analysis of station observations shows that daily extreme temperatures (T), specific humidity (q) and TWs generally co-occur in southeastern China while extreme TW and T rarely overlap in the arid and semi-arid North and Northwest China. Overall, q contributes more than T to extreme TWs, especially in North and Northwest China. Based on the relative contributions of q and T, regional extreme TW events are classified as q-dominated and T-dominated, respectively, to study their large-scale environment. Cluster analysis of global reanalysis data shows that extreme TWs are generally accompanied by increased surface air temperature and humidity, concomitant with anomalous high-pressure and notable water vapor flux convergence. However, important differences are also seen in the large-scale environment during q-dominated and T-dominated extreme TWs. During q-dominated extreme TWs, the large-scale environment favors convection, as indicated by ascending motions, decreased downward solar radiation (DSR) as well as increased precipitable water and near surface relative humidity. In contrast, during T-dominated extreme TWs, convection is inhibited by the large-scale environment that features descending motion and increased DSR, decreased precipitable water as well as decreased relative humidity. Consistent with the contrasting environments, we demonstrate that T-dominated extreme TWs tend to last longer than q-dominated extremes. Given the significant role of moisture in extreme TWs, more research is needed to understand its impacts on heat stress now and in the future.

extreme wet bulb temperatures, Moisture, synoptic ↗

Characterizing Sub-Daily Flow Regimes: Implications of Hydrologic Resolution on Ecohydrology Studies

Natural variability in flow is a primary factor controlling geomorphic and ecological processes in riverine ecosystems. Within the hydropower industry, there is growing pressure from environmental groups and natural resource managers to change reservoir releases from daily peaking to run-of-river operations on the basis of the assumption that downstream biological communities will improve under a more natural flow regime. In this paper, we discuss the importance of assessing sub-daily flows for understanding the physical and ecological dynamics within river systems. We present a variety of metrics for characterizing sub-daily flow variation and use these metrics to evaluate general trends among streams affected by peaking hydroelectric projects, run-of-river projects and streams that are largely unaffected by flow altering activities. Univariate and multivariate techniques were used to assess similarity among different stream types on the basis of these sub-daily metrics. For comparison, similar analyses were performed using analogous metrics calculated with mean daily flow values. Our results confirm that sub-daily flow metrics reveal variation among and within streams that are not captured by daily flow statistics. Using sub-daily flow statistics, we were able to quantify the degree of difference between unaltered and peaking streams and the amount of similarity between unaltered and run-of-river streams. The sub-daily statistics were largely uncorrelated with daily statistics of similar scope. Furthermore, on short temporal scales, sub-daily statistics reveal the relatively constant nature of unaltered streamreaches and the highly variable nature of hydropower-affected streams, whereas daily statistics show just the opposite over longer temporal scales.

54 ENVIRONMENTAL SCIENCES↗

An omnipresent diversity and variability in the chemical composition of atmospheric functionalized organic aerosol

Abstract The atmospheric evolution of organic compounds encompasses many thousands of compounds with varying volatility, polarity, and water solubility. The molecular-level chemical composition of this mixture plays a major, yet uncertain, role in its transformations and impacts. Here we perform a non-targeted molecular-level intercomparison of functionalized organic aerosol from three diverse field sites and a chamber. Despite similar bulk composition, we report large molecular-level variability between multi-hour organic aerosol samples at each site, with 66 ± 13% of functionalized compounds differing between consecutive samples. Single precursor environmental laboratory chamber experiments and fully chemically-explicit modeling confirm this variability is due to changes in emitted precursors, chemical age, and/or oxidation conditions. These molecular-level results demonstrate greater compositional variability than is typically observed in less-speciated measurements, such as bulk elemental composition, which tend to show less daily variability. These observations should inform future field and laboratory studies, including assessments of the effects of variability on aerosol properties and ultimately the development of strategic organic aerosol parameterizations for air quality and climate models.

Ditto, Jenna C.↗

Direct dark matter searches with metal halide perovskites

Polar materials with optical phonons in the meV range are excellent candidates for both dark matter direct detection via dark photon-mediated scattering and light dark matter absorption. In this study, we propose, for the first time, the metal halide perovskites MAPbI 3 , MAPbCl 3 , and CsPbI 3 for these purposes. Our findings reveal that CsPbI 3 is the best material, significantly improving exclusion limits compared to other polar materials. For scattering, CsPbI 3 can probe dark matter masses down to the keV range. For absorption, it enhances sensitivity to detect dark photon masses below ∼10 meV. The only material that has so far been investigated and that could provide competitive bounds is CsI, which, however, demonstrates lower stability as device platform compared to CsPbI 3 . Moreover, CsI is isotropic while the anisotropic structure of CsPbI 3 enables daily modulation analysis, showing that a significant percentage of daily modulation exceeding 1% is achievable for dark matter masses below 40 keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-39: Dosimetric Benefit of Implanted Marker-Based CBCT Setup for Definitive Prostatic Radiotherapy

Purpose Daily setup for definitive prostatic radiotherapy is challenged by suboptimal visibility of the prostate boundary and daily variation of rectum shape and position. For patients with improved bowel preparation, we conducted a dosimetric comparison between prostate implanted marker (IM)-based daily setup and anterior rectal wall (ARW)-based setup, with the hypothesis that the former leads to adequate target coverage with better rectal sparing. Methods Five IMRT/VMAT prostate cases with implanted markers were selected for analysis. Daily CBCT showed improvement of the rectal volume compared to planning CT. For each patient, the prostate and rectum were contoured on three CBCT images (fraction 5/15/25) with subsequent physician review. The CBCTs were then registered to a planning CT using IM-based registration. The deviation of ARW positions from planning CT to CBCT were analyzed at various sup-inf levels (−1.8 cm to 1.8 cm from level of prostate center). To estimate the potential dosimetric impact from ARW-based setup, the treatment plans were recalculated using A-P shifts ranging from −1mm to +6mm. Clinically important rectum DVH values including Dmax, D3cc and Dmean were computed. Results For the studied patients, we observed on average 32% rectum volume reduction from planning CT to CBCT. As a Results, the ARW on average shifts posteriorly by −1mm to +5mm, depending on the sup-inf level of observation, with larger shifts observed at more superior levels. Recalculation shows that when ARW shifts 1mm posteriorly, ARW-based CBCT setup leads to a 1.0%, 4.2%, and 3.2% increase in rectum Dmax, D3cc, and Dmean, respectively, compared to IM-based setup. The dosimetric deviations increase to 4.7%, 25.8% and 24.7% when ARW shifts 6mm posteriorly. No significant prostate-only dose difference was observed. Conclusion For patients with improved bowel preparation, IM-based CBCT setup leads to accurate prostate coverage along with significantly lower rectal dose, compared to ARW-based setup.

60 APPLIED LIFE SCIENCES↗

Rhizosphere Soil Biogeochemical Data and Photosynthetic Data of Vicia Faba in a Rhizobox

Here we share the data in column format via csv files for pH, redox, and dissolved oxygen collected at hourly resolution from microelectrodes. Dissolved organic carbon concentrations collected from TOC are also provided in a similar format but are composited samples from hourly microdialysis collection. This provided resolution of diel rhizosphere dynamics belowground. Plant physiological data was also collected at every 5 min for 24 hr cycles in order to capture diel dynamics aboveground. This data was used to parameterize the reaction transport model eSTOMP-ROOTS, which examines the rhizosphere biogeochemistry of a growing Vicia faba plant. The aim was to investigate plant activity and belowground biogeochemical processes, particularly their impact on mineral-organic associations in the rhizosphere. We combined in-situ rhizosphere microsensor and plant physiological measurements with a 3-D plant-soil reactive transport model to explore the behavior of dissolved organic carbon (DOC) in the rhizosphere. Over several days, microdialysis probes placed at the root-soil interface in live soil showed distinct daily patterns of DOC concentration in the pore water. Spikes in DOC concentrations during the day aligned with peaks in leaf-level photosynthesis, accompanied by decreasing redox potential and dissolved oxygen levels, and increasing pH in the rhizosphere. This new mechanistic modeling framework, which integrates aboveground plant physiological data with non-destructive, high-resolution monitoring of rhizosphere processes, offers significant potential for studying the factors that control carbon storage in soils.

54 ENVIRONMENTAL SCIENCES↗

Numerically study on a new hybrid photovoltaic thermal (PVT) collectors with natural circulation

Traditional design of Hybrid photovoltaic thermal (PV/T) system has the solar cells fixed on the top of the absorber. A new PV/T system in which the solar cells are pasted on the bottom of the glass cover is suggested with the aim of realizing higher electricity output considering the lower temperature of glass cover compared with that of absorber. A numerical analysis model is set up to compare the performances of the traditional PV/T and the new PV/T in this study. It is found that compared to the traditional PV/T, the new PV/T shows higher daily electric efficiency. But this superiority is not as apparent as expected. The key point to increase the daily electric efficiency of a PV/T lies in increasing the solar energy transfer efficiency of the solar cell. The total energy gain of the new PV/T is about 7% lower than that of the traditional PV/T because of smaller mass rate and more energy loss from glass cover with higher temperature.

14 SOLAR ENERGY↗

Admissible Powertrain Alternatives for Heavy-Duty Fleets: A Case Study on Resiliency and Efficiency

Heavy-duty vehicles dominate global freight movement and primarily rely on fossil-derived diesel fuel. However, fluctuations in crude oil prices and evolving emissions regulations have prompted interest in alternative powertrains to enhance fleet energy resiliency. This study paired real-world operational data from a large commercial fleet with high-fidelity vehicle models to evaluate the potential for replacing diesel internal combustion engine (ICE) trucks with alternative powertrain architectures. The baseline vehicle for this analysis is a diesel-powered ICE truck. Alternatives include ICE trucks fueled by bio- and renewable diesel, compressed natural gas (CNG) or hydrogen (H 2 ), as well as plug-in hybrid (PHEV), fuel cell electric (FCEV), and battery electric vehicles (BEV). While most alternative powertrains resulted in some payload capacity loss, the overall fleetwide impact was negligible due to underutilized payload capacity for the specific fleet considered in this study. For sleeper cab trucks, CNG-powered trucks achieved the highest replacement potential, covering 85% of the fleet. In contrast, H 2 and BEV architectures could replace fewer than 10% and 1% of trucks, respectively. Day cab trucks, with shorter daily routes, showed higher replacement potential: 98% for CNG, 78% for H 2 , and 34% for BEVs. However, achieving full fleet replacement would still require significant operational changes such as route reassignment and enroute refueling, along with considerable improvements to onboard energy storage capacity. Additionally, the higher total cost of ownership (TCO) for alternative powertrains remains a key challenge. This study also evaluated lifecycle impacts across various fuel sources, both fossil and bio-derived. Bio-derived synthetic diesel fuels emerged as a practical option for diesel displacement without disrupting operations. Conversely, H 2 and electrified powertrains provide limited lifecycle impacts under the current energy scenario. This analysis highlights the complexity of replacing diesel ICE trucks with admissible alternatives while balancing fleet resiliency, operational demands, and emissions goals. These results reflect a US-based fleet’s duty cycles, payloads, GVWR allowances, and an assumption of depot-only refueling/recharging. Applicability to other fleets and regions may differ based on differing routing practices or technical features such as battery swapping.

BEV↗

White Roofs

Secretary Steven Chu discusses the benefits of switching to white roofs and light colored pavements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Semi-continuous anaerobic co-digestion of thickened waste activated sludge and fat, oil and grease

Highlights: > Co-digestion of thickened waste activated sludge (TWAS) with fat, oil and grease (FOG). > Co-digestion of TWAS and FOG at 64% VS increased biogas production by 137%. > FOG addition ratio at 74% of total VS caused inhibition of the anaerobic digestion process. > Micronutrients addition did not significantly improve the biogas production and digestion stabilization. - Abstract: Co-digestion of thickened waste activated sludge (TWAS) and fat, oil and grease (FOG) was conducted semi-continuously under mesophilic conditions. The results showed that daily methane yield at the steady state was 598 L/kg VS{sub added} when TWAS and FOG (64% of total VS) were co-digested, which was 137% higher than that obtained from digestion of TWAS alone. The biogas composition was stabilized at a CH{sub 4} and CO{sub 2} content of 66.8% and 29.5%, respectively. Micronutrients added to co-digestion did not improve the biogas production and digestion stabilization. With a higher addition of FOG (74% of total VS), the digester initially failed but was slowly self-recovered; however, the methane yield was only about 50% of a healthy reactor with the same organic loading rate.

09 BIOMASS FUELS↗