Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Curved detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Burst Populations and Detector Sensitivity

The F(sub T) (peak bolometric photon flux) vs. E(sub p) (peak energy) plane is a powerful tool to compare the burst populations detected by different detectors. Detector sensitivity curves in this plane demonstrate which burst populations the detectors will detect. For example, future CZT-based detectors will show the largest increase in sensitivity for soft bursts, and will be particularly well- suited to study X-ray rich bursts and X-ray Flashes. Identical bursts at different redshifts describe a track in the F(sub T)-E(sub p) plane.

Band, David L.↗

GRB Studies with Fermi

This slide presentation reviews the studies of Gamma Ray Bursts (GRB) with the Fermi Gamma Ray Space Telescope. Included are pictures of the observatory, with illustrations of the Large Area Telescope (LAT), and the Gamma-ray Burst Monitor (GBM) including information about both their capabilities. Graphs showing the GBM count rate over time after the GBM trigger for three GRBs, preliminary charts showing the multiple detector light curves the spectroscopy of the main LAT peak and the spectral evolution of GRB 080916C Burst Temporally-extended LAT emission.

Meegan, Charles A.↗

A Multi-Year Light Curve of Scorpius X-1 Based on CGRO BATSE Spectroscopy Detector Observations

A multi-year light curve of the low mass X-ray binary, Scorpius X-1, is constructed based on the Compton Gamma-ray Observatory (CGRO) Burst and Transient Source Experiment (BATSE) Spectroscopy Detector (SD) data in the nominal energy range of 10-20 keV. A detailed discussion is given of the reduction process of the BATSE/SD data. Corrections to the SD measurements are made for off-axis pointings, spectral and bandpass changes, and differences in the eight SD sensitivities. The resulting 4.4 year Sco X-1 SD light curve is characterized in terms of the time scales over which various types of emission changes occur. This light curve is then compared with Sco X-1 light curves obtained by Axiel 5, the BATSE Large Area Detectors (LADs), and the RXTE all-sky monitor (ASM). Coincident temporal coverage by the BATSE/SD and RXTE/ASM allows a direct comparison of the behavior of Sco X-1 over a range of high energies to be made. These ASM light curves are then used to discuss model constraints on the Sco X-1 system.

McNamara, B. J.↗

Characterization of NTD germanium and ion-implanted Si bolometers at 0.3K and 0.1K

Bolometer elements were built and tested using NTD germanium and ion-implanted Si thermometer elements. The thermal links were made using aluminum wires and NbC(x)N(y) coated carbon fibers. The temperature dependence of the detector resistance, lead thermal conductivity, and heat capacity were measured. The dependence of the detector resistance on applied electric field was also measured. This, combined with the current-voltage curve for the detector, allowed the calculation of the detector responsivity. Known amounts of energy were deposited into the detector by allowing X-rays from the decay of Fe-55 to be thermalized in the detector. In the best-measured case, the predicted pulse height/measured height was 1.04 + or - .05. The noise at frequencies above 25 Hz in the NTD Ge was near that predicted by thermodynamics. The noise below 25 Hz has a 1/f character and may be in the carbon fiber/bolometer junction. The implanted detectors show some 1/f noise which depends on the total thermometer volume. Comparison between noise measurements and theory will be presented.

Moseley, H.↗

SiC-based Photo-detectors for UV, VUV, EUV and Soft X-ray Detection

A viewgraph presentation describing an ideal Silicon Carbide detector for ultraviolet, vacuum ultraviolet, extreme ultraviolet and soft x-ray detection is shown. The topics include: 1) An ideal photo-detector; 2) Dark current density of SiC photodiodes at room temperature; 3) Dark current in SiC detectors; 4) Resistive and capacitive feedback trans-impedance amplifier; 5) Avalanche gain; 6) Excess noise; 7) SNR in single photon counting mode; 8) Structure of SiC single photon counting APD and testing structure; 9) Single photon counting waveform and testing circuit; 10) Amplitude of SiC single photon counter; 11) Dark count of SiC APD photon counters; 12) Temperature-dependence of dark count rate; 13) Reduce the dark count rate by reducing the breakdown electric field; 14) Spectrum range for SiC detectors; 15) QE curves of Pt/4H-SiC photodiodes; 16) QE curve of SiC; 17) QE curves of SiC photodiode vs. penetration depth; 18) Visible rejection of SiC photodiodes; 19) Advantages of SiC photodiodes; 20) Competitors of SiC detectors; 21) Extraterrestrial solar spectra; 22) Visible-blind EUV detection; 23) Terrestrial solar spectra; and 24) Less than 1KeV soft x-ray detection.

Yan, Feng↗

ORFEUS-SPAS - The Berkeley EUV spectrometer

The Berkeley EUV spectrometer of ORFEUS-SPAS, a joint project of NASA and the BMFT, incorporates a set of four novel spherically figured, varied line-space gratings used in a geometry that is similar to that of the classic Rowland mount to span an interval of 390 and 1200 A. Two spectral detector units containing curved microchannel plates and delay-line anodes encode the arriving photons in digital format for telemetry. An additional optic directs the image of the source in the entrance aperture onto a sealed FUV detector which is used to track the source as it drifts during an observation, enabling a postflight reconstruction of the spacecraft pointing vector. This in turn makes it possible to define with precision the wavelength of each recorded photon.

Bowyer, Stuart↗

The ALEXIS data processing package: An IDL based system

The Array of Low Energy X-ray Imaging Sensors (ALEXIS) experiment consists of a mini-satellite containing six wide angle EUV/ultrasoft x-ray telescopes. Its purpose is to map out the sky in three narrow (approximately 5 percent) bandpasses around 66, 71, and 93 eV. The 66 and 71 eV bandpasses are centered on intense Fe emission lines which are characteristic of million degree plasmas such as the one thought to produce the soft x-ray background. The 93 eV bandpass is not near any strong emission lines and is more sensitive to continuum sources. The mission will be launched on the Pegasus Air Launched Vehicle in the second half of 1992 into a 400-nautical-mile, high inclination orbit and will be controlled entirely from a small ground station located at Los Alamos. The project is a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratory, and the University of California-Berkeley Space Sciences Laboratory. The six telescopes are arranged in three pairs. As the satellite spins twice a minute they scan the entire anti-solar hemisphere. Each f/1 telescope consists of a spherical, multilayer-coated mirror with a curved, microchannel plate detector located at the prime focus. The multilayer coatings determine the bandpasses of the telescopes. The field of view of each telescope is 30 degrees with a spatial resolution of 0.5 degree, limited by spherical aberration. The data processing requirements for ALEXIS are large. Each event is one of the six telescopes is telemetered to the ground with its time of arrival and position on the detector. This information must be folded with the aspect solution for the satellite to reconstruct the direction on the sky from which the photon came. Because of the way the six telescopes scan the sky, the effective exposure calculation is also very computationally intensive. ALEXIS may generate up to 100 megabytes of raw data per day, which are converted into a gigabyte per day of processed data. While the processing job for ALEXIS is sizable, the programming staff is small. To maximize programming efficiency, and to make the best use of tools available in the public domain, we chose IDL as our software development platform. IDL was used from the start of instrument development through flight. We use IDL as a top-level executive for the processing tasks (replacing Unix shell scripts), as a device independent graphics engine, as a database manager, and as a final data manipulator. IDL routines spawn special purpose C programs to perform detailed telemetry deconvolution and other specialized functions. We discuss the use of IDL and C within the processing and archiving strategy for the ALEXIS data anlaysis system as implemented on a SPARCstation platform. We also show results from our End-to-End software simulation capability as processed by our analysis codes.

Bloch, J. J.↗

Evidence of sub-millisecond structure in a gamma-ray burst

It is reported here that GRB910711, the gamma-ray burst (GRB) with apparently the shortest duration yet seen by the BATSE, has a time profile that shows significant submillisecond structure. The responses to this burst in the BATSE detectors show that the burst is both narrower and of higher energy than is indicated by a light curve summed over all detectors. A narrow spike of duration 200 microsec was detected in the light curve; variations on this timescale have not previously been observed in GRBs, and their explanation should be a stringent test of any GRB theory.

Bhat, P. N.↗

On method of muon spectrum measurements by the scintillation detectors of a large thickness T4t sub o

Various methods for the study of muon spectrum are presented. The direct ones include the muon energy measurements by magnetic spectrometers. The indirect ones deal with the reconstruction of the muon spectrum from the spectrum of secondary particles obtained by burst or calorimeter technique. The burst technique is based on the measurement of the number of cascade particles, mainly in the cascade maximum, by the detectors of small thickness T sub 0. The calorimeter method consist in determination of the cascade energy with help of the cascade curve shape. The multilayer detectors are used for this purpose. They are usually comprised of proportional counters, X-ray emulsion chambers or scintillation counters with the target material placed between them. The scintillation detectors of a large thickness measures the total cascade energy directly and the detector works as a true calorimeter. When the total energy is detected, the cascade spectrum differs from the muon one.

Ryazhskaya, O. G.↗

New processes and materials for ultraviolet detection with solid state devices

The three major effects that degrade external responsivity of silicon from the 1/lambda theoretical curve for a quantum detector are: surface reflectance, surface recombination, and junction depth. Since the p-n junction must be very shallow, problems relating to surface are further enhanced. MOS type of processing is necessary. HCl oxides and numerous acid clean-ups are utilized in order to obtain a contamination free surface with low Qss levels. Stringent process controls such as CV shifts, spreading resistance measurements, thickness monitoring etc., are used to analyze the surface contaminations, surface mobile charges, surface concentrations, junction depth, oxide thickness etc. Low surface concentrations of 10 to the 18th atoms/cu cm are achieved by low temperature boron nitride depositions. Shallow junction depths of the order of a few tenths of a micron are achieved by low temperature controlled diffusions. In order to improve breakdown characteristics of these shallow junction devices, field plate and deep diffused p(+) ring geometries are used.

Chopra, D.↗

Undercooling measurement in a low-gravity containerless environment

A technique is described for measuring the amount of undercooling for samples processed in a low-gravity containerless environment. The time of undercooling is determined by measuring the time of cooling before nucleation and recalescence by two infrared detectors. Once the cooling curve for each drop is calculated, the amount of undercooling can then be found. The technique is demonstrated by measuring the amount of undercooling for drops of pure niobium and select compositions of the niobium-germanium alloy system while free falling in a 32 n evacuated drop tube. The total hemispherical emissivities and specific heats for these materials were measured using a high-temperature containerless calorimeter. An overview of the effect of undercooling on drops of niobium and niobium-germanium is given.

Robinson, M. B.↗

Rocket-borne instrument with a high-resolution microchannel plate detector for planetary UV spectroscopy

A telescope-spectrograph employing a photon-counting microchannel plate (MCP)-CODACON detector has been built, tested, and flown on a sounding rocket. The detector uses a curved-channel MCP proximity focused onto a coded anode array of 1024 channels spaced 25.4-mm center to center. High quantum efficiency is obtained by depositing a cesium iodide photocathode on the front surface of the MCP. The instrument has obtained an ultraviolet spectrum of Jupiter with a spectral resolution of 8 A, which is higher than that of any previously reported observation in this wavelength range.

Mcclintock, W. E.↗

Capabilities of germanium detectors

The gamma ray detection efficiency and energy resolution of germanium detectors is reviewed. A general sensitivity equation for gamma-ray detectors is presented and calculated sensitvity curves are shown for a large volume balloon-borne spectrometer using germanium detectors. Improvement anticipated from a planned satellite experiment using germanium detectors is discussed.

Willett, J. B.↗

Phase Diagram, Melt Growth and Characterization of Cd0.8Zn0.2Te Crystals for X-Ray Detector

In this study, the solidus curve of the Cd0.8Zn0.2Te homogeneity range was constructed from the partial pressure measurements by optical absorption technique which provided the information of the melt growth parameters to process crystals with the required electrical resistivity. The melt growth of Cd0.8Zn0.2Te crystals were then processed by directional solidification under controlled Cd overpressure. During the growth experiments, several procedures have been developed to improve the crystalline quality: (1) minimizing the contamination of impurities (2) improving the structural defects and (3) minimizing the Te-precipitates within the grown crystals to enhance charge transport properties. Additionally, the thermal conductivity, electrical conductivity, and Seebeck coefficient of a vapor-grown CdTe and two melt-grown Cd0.8Zn0.2Te crystals were measured between 190oC and 780oC to provide an in-depth understanding of the thermal and electrical conduction mechanisms of the crystals as well as the prospect of its thermoelectric applications.

x-ray detector↗

System measures response time of photomultiplier tubes

Calibration system enables precise determination of rise time of photosensitive detectors. To perform a calibration, the time-voltage curve of the excitation voltage for a light source is compared with the time-voltage curve of the voltage output from a photosensitive detector which is responding to the light.

Lauver, M. R.↗

Earth Occultation Monitoring with the Fermi Gamma Ray Burst Monitor

Using the Gamma Ray Burst Monitor (GBM) on-board Fermi, we are monitoring the hard X-ray/soft gamma ray sky using the Earth occultation technique (EOT). Each time a source in our catalog is occulted by (or exits occultation by) the Earth, we measure its flux using the change in count rates due to the occultation. Currently we are using CTIME data with 8 energy channels spanning 8 keV to 1 MeV for the GBM NaI detectors for daily monitoring. Light curves, updated daily, are available on our website http://heastro.phys.lsu.edu/gbm. Our software is also capable of performing the Earth occultation monitoring using up to 128 energy bands, or any combination of those bands, using our 128-channel, 4-s CSPEC data. The GBM BGO detectors, sensitive from about 200 keV to 40 keV, can also be used with this technique. In our standard application of the EOT, we use a catalog of sources to drive the measurements. To ensure that our catalog is complete, our team has developed an Earth occultation imaging method. In this talk, I will describe both techniques and the current data products available. I will highlight recent and important results from the GBM EOT, including the current status of our observations of hard X-ray variations in the Crab Nebula.

Wilson-Hodge, Colleen A.↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗