Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Hybrid Transmitter With Voltage-Mode SST Preemphasis and Current-Mode Transmitter Equalization Capable of Operating at 77 K in DUNE

The Deep Underground Neutrino Experiment (DUNE) requires that the front-end transmitters operate at cryogenic temperature and drive 25–35 m long twin-axial (twinax) cables. Here, to compensate the frequency-dependent channel loss over the long cables and alleviate the de-emphasizing of the low-frequency signal magnitude, a hybrid of a current-mode (CM) transmitter equalization (TXEQ) and a voltage-mode (VM) preemphasis is proposed. The TXEQ employs a finite-impulse response (FIR) filter to boost the high-frequency components while de-emphasizing the low-frequency signal magnitude, thereby flattening the overall channel frequency response and reducing the intersymbol interference (ISI). The VM preemphasis is proposed to further mitigate ISI by boosting the high-frequency portion without degrading the signal magnitude, allowing for high signal swing. The main driver utilizes VM source-series-terminated (SST) output stages, which offers higher signal swing and better power efficiency than the conventional CM logic (CML) drivers. To ensure the lifetime and reliability at cryogenic temperature, the transmitter is implemented in a 65-nm CMOS process operating at 1.1 V of supply voltage and employing transistors with larger than minimum lengths. Silicon measurement results at 77 K have validated the proposed approaches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A pulsed current-mode class-D low-voltage high-bandwidth power amplifier for portable NMR systems

Low-field NMR has seen growing interest in recent years, especially for portable applications. The lower homogeneity magnets used for portable applications require short RF pulses to ensure enough transmit bandwidth to excite the sample volume and also support short echo periods. Furthermore, the preferred use of a high-Q coil to improve signal-to-noise ratio (SNR) prolongs the pulse transients. Thus, at such low Larmor frequencies, the excitation pulse transients become comparable or longer than the pulse length, such that the transmit bandwidth begins to limit measurement SNR. This paper describes the design of a pulsed current-mode class-D power (PCMCD) transmitter that addresses this issue by generating high power in a tuned sample coil while maintaining short transients, thus resulting in high output bandwidth. The transmitter also uses a charge recycling mechanism to maximize power efficiency for RF train excitation, which also results in faster pulse repetition rate and reduces allowable echo time. In this work, experimental results from a small form-factor PCMCD transmitter are presented. This design generates a peak RF power of 240 W into a 9.16 µH coil at 4 MHz while operating off a single 12 V power supply. NMR measurement results using the transmitter are also described, showing minimum achievable echo time of 70 µs and 25 µs depending on the transmitter mode of operation.

47 OTHER INSTRUMENTATION↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HTS Quadrupole Magnet for the Persistent Current Mode Operation

In this work, a new high-temperature superconducting (HTS) quadrupole magnet with circular coils was designed and built at Fermilab. Several HTS coils were also investigated at the temperature of liquid nitrogen. The main goal of this activity was to investigate the coils and magnet operation in a persistent current mode to reduce accelerator magnets’ capital and operational expenses. To accomplish this, HTS short-circuit coils were used. In the paper, HTS coils and magnet design, fabrication, and tests were discussed. The magnetic field in the magnet aperture and the field decay when the magnet operated in the “frozen flux” mode were measured. The test and simulation results were compared, confirming the advantages of the proposed approach.

43 PARTICLE ACCELERATORS↗

Synchrotron characterization of high-Z, current-mode x-ray detectors

Fast x-ray detectors are critical tools in pulsed power and fusion applications, where detector impulse response of a nanosecond or better is often required. Semiconductor detectors can create fast, sensitive devices with extensive operational flexibility. There is typically a trade-off between detector sensitivity and speed, but higher atomic number absorbers can increase hard x-ray absorption without increasing the charge collection time, provided carriers achieve high velocity. This paper presents x-ray pulse characterization conducted at the Advanced Photon Source of x-ray absorption efficiency and temporal impulse response of current-mode semiconductor x-ray detectors composed of Si, GaAs, and CdTe.

47 OTHER INSTRUMENTATION↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method of transient control for robust enrichment operation in low temperature combustion engine

A method of transient control for enrichment operation in a low-temperature combustion engine. The method includes determining if a current mode of the low-temperature combustion (LTC) engine is a positive valve overlap (PVO) mode. Determining if a previous mode of the LTC engine was also the PVO mode when the current mode is the PVO mode, wherein the previous mode is immediately prior to the current mode. Determining if the previous mode of the LTC engine was a negative valve overlap (NVO) mode when the previous mode was not the PVO mode. Initiating a predetermined enrichment PVO mode for the LTC engine based on the previous mode of the LTC engine. The predetermined enrichment PVO mode includes initiating a deep enrichment PVO mode, when the previous mode of the LTC engine was the NVO mode, and initiating a shallow enrichment PVO mode, when the previous mode of the LTC engine was not the NVO mode.

Yun, Hanho↗

Matrix converter operating in current control mode using feed forward signals

A matrix converter system having a current control mode operation is provided. The system includes a matrix converter having a switching matrix. The matrix converter is coupled at its low-voltage side to a generator and at its output load side to a load. A controller having a pulse width modulation (PWM) control circuit is configured to control the matrix converter via its switching matrix to increase energy within the internal inductances of the generator when the switching matrix causes a short circuit. A feed forward calculator is configured to calculate a feed forward output phase angle. The feed forward output phase angle is an estimation of an angle between an output current vector and an output voltage vector that represent feedback signals of current and voltage output by the matrix converter. The angular position of the voltage output vector is adjusted as a function of the feed forward output phase angle to align angular position or phase angle of the voltage output vector that represents the voltage output with a selected angular position or phase angle.

42 ENGINEERING↗

Matrix converter operation in current control mode with regulation of output voltage vector

A matrix converter system having a current control mode operation is provided. The matrix converter system includes a matrix converter that includes a plurality of switches. A unity current reference vector having an amplitude of one is determined that defines an angle and frequency of an output current vector as a function of a reference phase angle, which is a function of the output current vector and an output voltage vector representing feedback signals of a multiphase signal output to a load. The unity current reference vector is used to control the matrix converter, to cause the output current vector to be aligned with the unity current reference vector. A unity voltage reference vector having an amplitude of one is provided that defines a reference angle and frequency as a function of a zero phase angle. The output voltage vector and the unity voltage reference vector are aligned to determine the reference phase angle as an angle between the aligned output voltage vector and the output current vector.

42 ENGINEERING↗