Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current clamp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Flaming Moe

Current clamp measurements collected on various small electronic devices. Details on the data set can be found in J. M. Vann, T. P. Karnowski, R. Kerekes, C. D. Cooke and A. L. Anderson, A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions, in IEEE Transactions on Electromagnetic Compatibility, vol. 60, no. 1, pp. 122-131, Feb. 2018, doi: 10.1109/TEMC.2017.2692962.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Optimized H5 Hysteresis Current Control with Clamped Diodes in Transformer-Less Grid-PV Inverter

With the rise of renewable energy penetration in the grid, photovoltaic (PV) panels are connected to the grid via inverters to supply solar energy. Transformer-less grid-tied PV inverters are gaining popularity because of their improved efficiency, reduced size, and lower costs. However, they can induce a path for leakage currents between the PV and the grid due to the absence of galvanic isolation. This leads to serious electromagnetic interference, loss in efficiency, and safety concerns. The leakage current is primarily influenced by the nature of the common mode voltage (CMV), which is determined by the switching techniques of the inverter. In this paper, a novel inverter topology of Hysteresis Controlled H5 with Two Clamping Diodes (HCH5-D2) is derived. The HCH5-D2 topology helps decouple the AC part (Grid) and DC part (PV) during the freewheeling period to make the CMV constant, thereby reducing the leakage current. Additionally, the extra diodes help reduce voltage spikes generated during the freewheeling period and maintain the CMV at a constant value. Finally, a 2.2 kW grid-connected single-phase HCH5-D2 PV inverter system’s MATLAB simulation is presented, showing better results compared to a traditional H4 inverter.

42 ENGINEERING↗

Understanding the formation of a low-pressure pedestal in the presence of a strong internal transport barrier in DIII-D high β p plasmas

As a promising scenario for fusion reactors, the high poloidal-beta (β P ) scenario is characterized by a strong large radius internal transport barrier (ITB), which significantly enhances the overall confinement quality and the bootstrap current fraction for fully non-inductive operation. It is frequently observed that in the presence of a strong ITB, the pedestal height is lower and is accompanied by small edge localized modes (ELMs), which further improves the compatibility of a high performance core with an edge solution. A mechanism for the formation of the low pedestal is proposed in this paper. It is found that the strong ITB creates an off-axis bootstrap current to clamp the local safety factor q, and thus the magnetic shear in the outer core/pedestal region is increased. Gyrokinetic simulations with the CGYRO code show that the higher magnetic shear brings the experimental profiles into the range where the growth rate of drift-wave instabilities and thus transport is higher, and therefore a lower pedestal gradient is expected. Here, the combination of low pedestal and high magnetic shear further enhances the turbulent transport across the whole pedestal, consistent with power balance analysis. Such a positive feedback mechanism ultimately results in a lower pressure pedestal as observed in experiments. Under such a low pedestal, linear simulations with BOUT++ predict the growth rates of peeling–ballooning modes to be lower across the whole toroidal mode number spectra, and the nonlinear BOUT++ simulation exhibits lower saturated fluctuation intensity as well, consistent with the experimentally observed lower ELM size.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Two-Stage Current Limiting Control Strategy for Direct-Droop-Controlled Grid-Forming Inverters

This paper presents a two-stage current limiting control strategy with fault ride-through capability for the direct-droop-controlled grid-forming (GFM) inverters. The proposed approach comprises Stage 1 and Stage 2 current limiting controls. During faults, Stage 1 current limiting control instantly clamps the inverter output current magnitude to its maximum transient limit by blocking the switching pulses to the insulated-gate bipolar transistors (IGBTs) with the help of a hysteresis loop control, and Stage 2 current limiting control limits the inverter output current magnitude to its steady-state limit by regulating the amplitude and frequency of the modulating waveform utilizing the active and reactive current limiting control loops. By implementing the current limiting actions in two stages, this approach can effectively limit the over-current within a few cycles after the fault occurrence and ensure synchronism to the grid after long-term fault events. The efficacy of the proposed control approach is validated through electromagnetic transient (EMT) simulation results conducted on a single GFM inverter-based test system and the IEEE 39-bus test system with multiple GFM inverters in the PSCAD platform.

Mohiuddin, Sheik Mohammad↗

DC Circuit Breakers: A Technology Development Status Survey

DC circuit breakers (DCCBs) play a significant role in obtaining the reliability and stability of DC power systems. Selective and fast isolating of faults minimizes the power supply outages to end electricity users and protects the power converters implemented in the DC system. During the last decades, DCCBs have been deeply investigated in industry and academia. There has been impressive progress in terms of efficiency, response time, power-density, lifetime, and electrical operating ratings. Introducing wide bandgap (WBG) devices further has motivated researchers to propose more efficient and novel topologies. This paper provides a point of reference and a background review for DCCBs from novel aspects, fulfilling absent parts in the literature. The elaborated subjects include current commutation circuitry, DCCBs trip-curves developments, newly added functions to DCCBs, as well as marketing analysis. The advancements of DCCBs are surveyed and development needs are recognized. This paper aims to identify the future research needs of DCCBs for emerging DC power systems.

42 ENGINEERING↗

Switching Modes for Reduction of Peak Voltage Transients in GaN-Based Three Level ANPC Inverter

The switching pole voltage can transition between P,0, and N states in a three-level active neutral point clamped (ANPC) inverter. State transitions between 0-P and 0-N can be realized with different switching modes. Three switching modes- Short 1 , Short 2 , and Full are studied considering the effect of capacitive current paths. The role of clamping and inner switch on/off conditions is determined using simplified equivalent circuit models. Short 2 with clamping switch off is beneficial for turn-on overvoltage suppression but results in high turn-off overvoltage. Full mode with a parallel current sharing path is effective for turn-off overvoltage suppression but leads to high turn-on overvoltage. Hence, a Modified Full mode is proposed to achieve the simultaneous objective of overvoltage suppression at both turn-on and turn-off transient during high load currents. This benefits 3L ANPC operation at a low power factor with a high load current at fundamental voltage zero crossing points. Here, a 650V GaN-based three-level ANPC inverter prototype is designed and used to evaluate the switching modes and overvoltage suppression strategies through double pulse tests and continuous operation.

42 ENGINEERING↗

Aligning thermal and current quenches with a high density low-Z injection

The conventional approach for thermal quench (TQ) mitigation in a tokamak disruption is through a high- Z impurity injection that radiates away the plasma’s thermal energy before it reaches the wall. The downside is a robust Ohmic-to-runaway current conversion due to the radiatively clamped low post-thermal-quench electron temperature. An alternative approach is to deploy a low- Z (either deuterium or hydrogen) injection that aims to slow down the TQ, and ideally aligns it with the current quench (CQ). This approach has been investigated here via 3D MHD simulations using the PIXIE3D code. By boosting the hydrogen density, a fusion-grade plasma is dilutionally cooled at approximately the original pressure. Energy loss to the wall is controlled by a Bohm outflow condition at the boundary where the magnetic field intercepts a thin plasma sheath at the wall, in addition to Bremsstrahlung bulk losses. Robust MHD instabilities proceed as usual, while the collisionality of the plasma has been greatly increased and parallel transport is now in the Braginskii regime. The main conclusion of this study is that the decreased transport loss along open field lines due to a sufficient low- Z injection slows down the TQ rate to the order of 20 ms, aligned with the CQ timescale for a 15 MA ITER plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inverse Segmented Motor Drive Using Dual ANPC Inverters for Common-Mode Voltage and Neutral-Point Current Cancellation

This article proposes an inverse segmented motor drive (SgMD) utilizing dual active neutral point clamped (ANPC) inverters. In the proposed configuration, the neutral point current and common-mode (CM) voltage is topologically canceled, achieving zero total neutral point current and CM voltage under ideal conditions. Also, the zero total neutral point current minimizes the neutral point voltage imbalance in ANPC inverters. The mechanisms behind neutral point current and CM voltage cancellation in the proposed inverse SgMD are first introduced. The modifications to the motor windings for implementing the inverse SgMD are explained, showing that a standard motor can be readily adapted for the proposed configuration. A space vector modulation (SVM) scheme tailored for the proposed topology is presented, along with a carrier-based implementation. Simulation results validate that the proposed topology can achieve zero total CM voltage and neutral point current. It is also shown that the proposed inverse SgMD can reduce neutral point voltage fluctuation by about 90% and RMS current stress in the dc-link capacitors by about 43% compared to the conventional SgMD.

Lee, Sangwhee [ORNL] (ORCID:0000000335490057)↗

Pulse generator

A pulse shaping device includes an inductor that is selectively output-coupled to a first port of a capacitor. The inductor is charged to a selected current throughput and then coupled to the first port to generate a first characteristic within the current flowing at a second port of the capacitor. The capacitor is charged until reaching a clamping voltage at the first port. A voltage clamp of the shaping device clamps the first port of the capacitor at the clamping voltage to generate a second characteristic within the current flowing at a second port of the capacitor.

Zan, Xin↗

Custom Equipment Development for Processing of Surplus Plutonium

The Strategic Laboratory Assessment (SLA), a collaborative team of SRNL and ORNL personnel, has been established to advance the objectives of the Surplus Plutonium Disposition (SPD) Project, by identifying and developing technologies to accelerate disposition, reduce life cycle costs, minimize worker radiation exposure, improve worker safety, and minimize Surplus Plutonium Disposition Program risks. [1] The SLA team has identified can cutting and plutonium (Pu) oxide size reduction as two glovebox processes where technology enhancements would be valuable. The DOESTD-3013 package currently in use for Pu downblending requires cutting two nested cans before the inner convenience can that holds the Pu oxide may be accessed for further processing. A rotary tubing-style cutter is used for opening the 3013 packages within the glovebox. Collet changeouts are required between cutting of the outer and inner cans. The SLA team is currently developing and testing an adjustable-clamp can cutter design that eliminates collet changeouts and allows cutting of the outer and inner can at the same time, resulting in significant reduction of radiological dose and process time, as well as improved ergonomics. To meet the Pu oxide particle size requirement, size reduction of Pu oxide agglomerations must be performed within the process gloveboxes. The SLA team has identified jaw crushing technology as an alternative to the currently employed rotary mill. Jaw crusher advantages include reduced dust within the glovebox, increased batch sizes, and easier integration with other glovebox processes due to the flow-through nature of jaw crushing. Commercially manufactured jaw crushers are either too large and/or too heavy for implementation in the SPD gloveboxes, so the SLA team is developing and testing a custom jaw crusher to meet the needs of the SPD Project.

Krementz, Daniel [Savannah River National Laborato↗

Self-organized magnetic equilibria in tokamak plasmas with very low edge safety factor

Tokamak plasmas often exhibit self-organizing behavior in which internal modes shape the toroidal current density profile, a common example being the sawtooth instability. However, such behavior has not been studied in detail for edge safety factor below 2 due to disruptive kink instabilities that typically prevent operation in this regime. Now, steady tokamak plasmas with an edge safety factor down to 0.8 have been created in the Madison Symmetric Torus, where disruptions are prevented due to a thick, conductive wall and a feedback power supply that sustains the plasma current. Internal measurements and nonlinear magnetohydrodynamic modeling reveal a family of safety factor profiles with a central value clamped near unity as the edge safety factor decreases, indicating current profile broadening through a relaxation process. Furthermore, as the safety factor decreases, the magnetic fluctuations become irregular, and the electron energy confinement time decreases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power Layout Design of a GaN HEMTs-Based High-Power High-Efficiency Three-Level ANPC Inverter for 800 V DC Bus System

Multiple commutation paths exist for switching devices in a three-level active neutral point clamped (3L-ANPC) inverter operation based on the selected switching state and current direction. In addition, the capacitive coupling path of the nonswitching device is a key design aspect for enabling high voltage and high current operation of gallium nitride (GaN) switches in 3L-ANPC topology. A comprehensive study of the switching transient events of inner, outer, and clamping devices of 3L-ANPC is presented in this article. The commutation mechanisms for worst-case transient voltage overshoots (TVOs) are identified. A simplified equivalent circuit model is presented to determine the design criteria for the power layout structure's parasitic inductances. A power layout strategy satisfying the design criteria is then proposed using an insulated metal substrate power printed circuit board (PCB) to enable efficient high-power operation. The proposed design minimizes the commutation and capacitive coupling path inductances to 6 nH and 11.5 nH, respectively. This enables the fast switching operation of GaN HEMTs at 800 V dc, 36 A with a low TVO of 31% verified through experimental three-level double pulse test results. Experimental evaluation of a three-phase 3L-ANPC hardware prototype based on the proposed power layout shows 99% efficiency at 800 V, 9.5 kVA and 50 kHz switching frequency. The proposed design achieves a low case-to-ambient thermal resistance of 2.3 °C/W.

42 ENGINEERING↗

One-dimensional mapping of femtosecond laser filaments using coherent microwave scattering

Here, this paper reports on the use of coherent microwave scattering (CMS) for spatially resolved electron number density measurements of elongated plasma structures induced at mid-IR femtosecond filamentation in air. The presented studies comprise one-dimensional mapping of laser filaments induced via 3.9 µm, 127.3 fs laser pulses at output energies up to 15 mJ. The axial electron number density was measured to be invariant (about 2 × 10 15 c⁢m −3 ) along the entire filament length and for all tested laser pulse energies 5–15 mJ, and the corresponding laser intensity in the middle portion of the filament was estimated to be nearly constant for 5–15 mJ pulse energies (about 30−40 TW/c⁢m 2 ). These findings support that intensity clamping conditions were achieved in the experiments. The proposed approach enables capabilities that are currently unavailable to perform absolute and longitudinally resolved measurements of electron number density in laser filaments and to precisely characterize conditions associated with self-focusing and intensity clamping.

plasma diagnostic techniques↗

A Voltage Injection-Based Current Harmonics Suppression Strategy for Six-Phase PMSM With Nonsinusoidal Back EMF

This article presents a voltage injection-based current harmonic minimization method for wide bandgap device-based six-phase permanent magnet synchronous machine (PMSM) drives. The presence of low-order harmonics is common in the back EMF of PMSMs with low slot and high pole numbers. The back EMF harmonics generate low-order harmonic currents that increase torque ripples. Furthermore, zero-sequence current (ZSC) is also observed if all six phases are connected to a common neutral point. ZSC does not affect the torque ripple but reduces the system efficiency. A special technique is required to reduce ZSC for variable speed drives as direct ac component to synchronous reference frame (SRF) dc transformation is not possible for ZSC. In this article, a voltage injection-based current harmonics reduction method is proposed. The injected harmonic voltage coefficients are calculated from the harmonic estimations of back EMF and updated using closed-loop harmonic compensators to improve steady-state performance. For ZSC reduction, third harmonics power controller, and for 6n ± 1 (n = 1, 2,...) order harmonic current reduction, SRF current controllers are presented in this article. Furthermore, the current harmonics minimization method is experimentally verified using a GaN-based three-level active neutral point clamped inverter-driven six-phase PMSM.

42 ENGINEERING↗

Spatiotemporal analysis of 3D human iPSC-derived neural networks using a 3D multi-electrode array

While there is a growing appreciation of three-dimensional (3D) neural tissues (i.e., hydrogel-based, organoids, and spheroids), shown to improve cellular health and network activity to mirror brain-like activity in vivo , functional assessment using current electrophysiology techniques (e.g., planar multi-electrode arrays or patch clamp) has been technically challenging and limited to surface measurements at the bottom or top of the 3D tissue. As next-generation MEAs, specifically 3D MEAs, are being developed to increase the spatial precision across all three dimensions (X, Y, Z), development of improved computational analytical tools to discern region-specific changes within the Z dimension of the 3D tissue is needed. In the present study, we introduce a novel computational analytical pipeline to analyze 3D neural network activity recorded from a “bottom-up” 3D MEA integrated with a 3D hydrogel-based tissue containing human iPSC-derived neurons and primary astrocytes. Over a period of ~6.5 weeks, we describe the development and maturation of 3D neural activity (i.e., features of spiking and bursting activity) within cross sections of the 3D tissue, based on the vertical position of the electrode on the 3D MEA probe, in addition to network activity (identified using synchrony analysis) within and between cross sections. Then, using the sequential addition of postsynaptic receptor antagonists, bicuculline (BIC), 2-amino-5-phosphonovaleric acid (AP-5), and 6-cyano-5-nitroquinoxaline-2,3-dione (CNQX), we demonstrate that networks within and between cross sections of the 3D hydrogel-based tissue show a preference for GABA and/or glutamate synaptic transmission, suggesting differences in the network composition throughout the neural tissue. The ability to monitor the functional dynamics of the entire 3D reconstructed neural tissue is a critical bottleneck; here we demonstrate a computational pipeline that can be implemented in studies to better interpret network activity within an engineered 3D neural tissue and have a better understanding of the modeled organ tissue.

3D culture↗

A Six-Phase Space Vector PWM Technique for Wide Bandgap Device-Based Three-Level Inverters

This article presents a space vector pulsewidth modulation (SVPWM) technique for wide bandgap (WBG) device-based three-level (3L) six-phase inverters. Implementation of the SVPWM techniques for any six-phase inverter is complex for its high number of possible voltage vectors. Different six-phase load configurations are also possible depending on the angle between two consecutive phases and neutral point connections. The implementation techniques change depending on the load configuration. Moreover, a common neutral point for all six phases leads to circulating currents. Capacitor voltage balancing is also needed for 3L inverters. Capacitor voltage balancing and addressing the circulating current problem further increases the implementation complexity. In this article, a generalized SVPWM technique is proposed for the six-phase 3L inverters that is implementable using two three-phase 3L SVPWM blocks. The SVPWM technique also ensures dc bus capacitor voltage balancing and minimizes circulating current. Here, the SVPWM technique is experimentally verified using a GaN-based 3L six-phase active neutral point clamped (ANPC) inverter prototype, and the results are presented in this article.

42 ENGINEERING↗

Evaluation of Clamshell Current Coupler for Online Frequency Domain and Spread Spectrum Time Domain Reflectometry to Detect Anomalies in Energized Cables

This document describes adaptation and evaluation of a clamshell inductive current coupler for online reflectometry testing (both frequency domain reflectometry and spread spectrum time domain reflectometry) to evaluate cable insulation degradation and anomalies. Safety-critical nuclear power plant cables were initially qualified for 40 years. However, as plants extend their operating licenses to 60 and 80 years, justification for continued safe operation includes test and monitoring programs. These will become more important as the industry moves to condition based qualification programs. Cable test programs traditionally involve manual interventions to disconnect cables, perform one or several tests, then reconnect the systems, usually during refueling outages occurring only every 18 to 24 months. This poses an operational burden that can be minimized by online testing or periodic connection to a coupler that may remain on the cable of interest or be clamped onto the cable without de-termination. This work investigates the adaptation of a clamshell inductive current coupler for either frequency domain reflectometry or spread-spectrum time domain reflectometry. The reflectometry test instrument injects a broad-band chirp or pseudo-noise signal onto a cable conductor and monitors for a reflected signal indicative of an impedance change caused by a damage condition. The instrument maximum input signal levels are typically 10 to 30 volts or less and the instruments will be damaged if subjected to 60 Hz power line voltages of 110, 220, or 480 VAC. One commercial spread-spectrum time domain reflectometry system has circuitry suitable for voltages up to 1 kV, but typical reflectometry tests are performed on de-energized cables. The clamshell inductive coupler provides >60 dB of 60 Hz attenuation with less than 10 dB loss in the 1-500 MHz test bandwidth of interest. An energized cable was successfully tested up to 6.7 kVp-p and frequency response plots imply that the tests could be extended to 10 kV or higher energized levels.

36 MATERIALS SCIENCE↗