Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Yield, variance and spatial distribution of electron–hole pairs in CsI

A Monte Carlo (MC) method previously developed has been applied to simulate the interaction of photons, with energies ranging from 50 eV to ~ 1 MeV, with CsI and the subsequent electron cascades. The MC model has been employed to compute nano-scale spatial distributions of electron-hole pairs and important intrinsic properties, including W, the mean energy per electron-hole pair, and the Fano factor, F. W exhibits discontinuities at the shell edges that follow the photoionization cross sections and decreases with increasing photon energy (from ~19 to 15 eV), with an asymptotic value of 15.2 eV at high energy. This decrease may contribute the initial rise in relative light yield with incident energy observed experimentally for CsI, thus suggesting that nonlinearity may be associated with intrinsic properties of the material at low energies. F is calculated to increase with increasing energy and has an asymptotic value of 0.28. A significant number of electron-hole pairs are produced through the different ionization channels of core shells and corresponding relaxation processes, which may explain why F is larger for CsI than for Si or Ge. Finally, the calculated spatial distributions show that the electron-hole pairs are primarily distributed along fast electron tracks. These spatial distributions constitute important input for large-scale simulations of electron-hole pair transport.

CsI.↗

Modeling of RMS Current in CSI Filter Capacitor and Minimum Conduction Loss Operation of CSI-Fed PMSM Drives for Traction Applications

This paper presents a new minimum conduction loss (MCL) torque control algorithm for current source inverter- (CSI-) fed permanent-magnet synchronous machine drives that improves the overall machine drive efficiency by minimizing the combined conduction losses in the inverter and machine at each operating point. First, analytical models of conduction losses in CSI-fed motor drives are presented, and a closed-form expression for optimal d-axis stator current to achieve MCL operation is derived. An expression for the rms current in both wye- and delta-connected CSI output capacitors is derived. A detailed simulation model that emulates the operation of a 100 kW SiC CSI-fed integrated machine drive (IMD) has been developed based on experimental results and finite element analysis. This simulation model is used to evaluate the proposed MCL control algorithm applied to a CSI-fed IMD system for a battery-electric vehicle traction drive, and the predicted total drive system loss with MCL control is compared to predicted losses with maximum-torque-per-ampere (MTPA) and minimum dc-link current (MDCC) control. Results show that MCL control can achieve loss reductions compared to the other two control algorithms over a wide range of operating conditions, with significant loss reductions >20% in the medium-speed regime.

42 ENGINEERING↗

Computer Simulation of Electron Thermalization in CsI and CsI(Tl)

A Monte Carlo (MC) model was developed and implemented to simulate the thermalization of electrons in inorganic scintillator materials. The model incorporates electron scattering with both longitudinal optical and acoustic phonons. In this paper, the MC model was applied to simulate electron thermalization in CsI, both pure and doped with a range of thallium concentrations. The inclusion of internal electric fields was shown to increase the fraction of recombined electron-hole pairs and to broaden the thermalization distance and thermalization time distributions. The MC simulations indicate that electron thermalization, following {gamma}-ray excitation, takes place within approximately 10 ps in CsI and that electrons can travel distances up to several hundreds of nanometers. Electron thermalization was studied for a range of incident {gamma}-ray energies using electron-hole pair spatial distributions generated by the MC code NWEGRIM (NorthWest Electron and Gamma Ray Interaction in Matter). These simulations revealed that the partition of thermalized electrons between different species (e.g., recombined with self-trapped holes or trapped at thallium sites) vary with the incident energy. Implications for the phenomenon of nonlinearity in scintillator light yield are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kinetic Monte Carlo simulations of excitation density dependent scintillation in CsI and CsI(Tl)

Nonlinear quenching of electron-hole pairs in the denser regions of ionization tracks created by γ-ray and high-energy electrons is a likely cause of the light yield nonproportionality of many inorganic scintillators. Therefore, kinetic Monte Carlo (KMC) simulations were carried out to investigate the scintillation properties of pure and thallium-doped CsI as a function of electron-hole pair density. The availability of recent experimental data on the excitation density dependence of the light yield of CsI following ultraviolet excitation allowed for an improved parameterization of the interactions between self-trapped excitons (STE) in the KMC model via dipole-dipole Förster transfer. The KMC simulations reveal that nonlinear quenching occurs very rapidly (within a few picoseconds) in the early stages of the scintillation process. In addition, the simulations predict that the concentration of thallium activators can affect the extent of nonlinear quenching as it has a direct influence on the STE density through STE dissociation and electron scavenging. This improved model will enable more realistic simulations of the nonproportional γ-ray and electron response of inorganic scintillators.

Wang, Zhiguo↗

Kinetic Monte Carlo Model of Scintillation Mechanisms in CsI and CsI(Tl)

We have developed a computational model of energy transfer processes in scintillators using the kinetic Monte Carlo (KMC) approach. In this publication, we focus on the alkali halide compound CsI both pure and doped with a range of thallium concentrations. The KMC model makes use of an explicit atomistic representation of the crystal lattice, activator sites, defect sites, and individual electron-hole pairs. The probability of individual diffusion, recombination, and scintillation events is calculated from rate equations parameterized with data published in the literature. Scintillation decay curves, relative intensities of emission peaks, and light yields are computed and found to be in good agreement with experimental data for a range of temperatures and thallium concentrations. This demonstrates that the KMC scintillation model is capable of reproducing both the kinetics and the efficiency of the scintillation process in CsI. In addition, novel predictions emerge from our simulations such as the diffusion distance distributions of self-trapped holes and excitons. Finally, the KMC scintillation model provides a framework for probing possible physical processes responsible for the nonlinear relationship between scintillation light yield and incident gamma-ray energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-I-11: Cascaded Linear System Model for Columnar CsI Flat Panel Imagers with Depth Dependent Gain and Blur

Purpose: To implement a depth dependent gain and blur cascaded linear system model (CLSM) for optimizing columnar structured CsI indirect conversion flat panel imager (FPI) for advanced imaging applications. Methods: For experimental validation, depth dependent escape efficiency, e(z), was extracted from PHS measurement of different CsI scintillators (thickness, substrate and light output). The inherent MTF and DQE of CsI was measured using high resolution CMOS sensor. For CLSM, e(z) and the depth dependent MTF(f,z), were estimated using Monte Carlo simulation (Geant4) of optical photon transport through columnar CsI. Previous work showed that Monte Carlo simulation for CsI was hindered by the non-ideality of its columnar structure. In the present work we allowed variation in columnar width with depth, and assumed diffusive reflective backing and columns. Monte Carlo simulation was performed using an optical point source placed at different depth of the CsI layer, from which MTF(z,f) and e(z) were computed. The resulting e(z) with excellent matching with experimental measurements were then applied to the CLSM, Monte Carlo simulation was repeated until the modeled MTF, DQE(f) also match experimental measurement. Results: For a 150 micron FOS HL type CsI, e(z) varies between 0.56 to 0.45, and the MTF at 14 cycles/mm varies between 62.1% to 3.9%, from the front to the back of the scintillator. The overall MTF and DQE(f) at all frequencies are in excellent agreement with experimental measurements at all frequencies. Conclusion: We have developed a CLSM for columnar CsI scintillators with depth dependent gain and MTF, which were estimated from Monte Carlo simulation with novel optical simulation settings. Preliminary results showed excellent agreement between simulation results and experimental measurements. Future work is aimed at extending this approach to optimize CsI screen optic design and sensor structure for achieving higher DQE(f) in cone-beam CT, which uses high kVp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comprehensive Efficiency Analysis of Current Source Inverter Based on CSI-Type Double Pulse Test and Genetic Algorithm

A current-source inverter (CSI) has a natural output voltage boost feature that can be advantageous for traction applications. Switching frequency is one of the easily-controlled variables that can be adjusted to improve the CSI efficiency at different operating points when the boost function is used. This paper investigates a CSI-based double-pulse test (DPT) measurement that mimics normal operation of the CSI. A loss model of the CSI is developed based on the CSI-type DPT experimental results. The impacts of the switching frequency and voltage boost ratio on the CSI efficiency and output voltage ripple are investigated. Based on the loss model, a genetic algorithm has been introduced that makes it possible to optimize the CSI's switching frequency and modulation index to maximize its efficiency under any desired operating condition.

current-source inverter, genetic algorithm, SPM ma↗

How Excitation Conditions Alter the Afterglow Characteristics of CsI:Tl,Sm Microcolumnar Films

Combining high light output with the microcolumnar structure, the CsI:Tl films significantly reduce the need for painful tradeoff between thickness (hence, stopping power) and spatial resolution. But both films and monocrystals share two important deficiencies that hinder their use in many high-speed imaging and computed tomography applications: a persistent afterglow and hysteresis. These properties receive the primary attention of this investigation. In our earlier work, we reported that codoping with Sm 2+ brings about a significant reduction in the afterglow of CsI:Tl. Here, focusing on the microcolumnar films, we examine this afterglow-suppressive effect over a wide range of exposure times, from milliseconds to seconds, and at temperatures between 0 °C and 60 °C. Our measurements reveal well-defined dependences on both parameters. At room temperature (20 °C), defined as the normal operating condition, a 10-ms X-ray pulse leaves an afterglow from the standard (Sm-free) CsI:Tl of about 1% at 2 ms after the end of the pulse, changing little as a function of pulselength. Doping with Sm 2+ , however, reduces that afterglow by at least an order of magnitude, although somewhat less so after longer (100 and 1000 ms) pulses. When we change the temperature, however, we find markedly different behavior. Here, we find that a temperature increase of only 60°, without changing the pulselength, cuts the afterglow of standard CsI:Tl films by a factor of 20. However, films of codoped CsI:Tl,Sm, whose afterglow has already been suppressed by the presence of Sm 2+ , show much less change as a function of either temperature or pulse duration. It is the presence of Sm 2+ that makes the biggest difference. As for hysteresis, we again see an improvement, with the performance of the codoped CsI:Tl,Sm films bettering that of the standard (Sm-free) films. After an exposure of 300 mR, the change in light output falls to within 1% of the original after 1 min, whereas standard CsI:Tl films require 30 min to reach the same level.

42 ENGINEERING↗

Signal and noise transfer properties of CMOS based active pixel flat panel imager coupled to structured CsI:Tl

Complementary metal-oxide-semiconductors (CMOS) active pixel sensors can be optically coupled to CsI:Tl phosphors forming a indirect active pixel flat panel imager (APFPI) for high performance medical imaging. The aim of this work is to determine the x-ray imaging capabilities of CMOS-based APFPI and study the signal and noise transfer properties of CsI:Tl phosphors. Three different CsI:Tl phosphors from two different vendors have been used to produce three system configurations. The performance of each system configuration has been studied in terms of the modulation transfer function (MTF), noise power spectra, and detective quantum efficiency (DQE) in the mammographic energy range. A simple method to determine quantum limited systems in this energy range is also presented. In addition, with aid of monochromatic synchrotron radiation, the effect of iodine characteristic x-rays of the CsI:Tl on the MTF has been determined. A Monte Carlo simulation of the signal transfer properties of the imager is also presented in order to study the stages that degrade the spatial resolution of our current system. The effect of using substrate patterning during the growth of CsI:Tl columnar structure was also studied, along with the effect of CsI:Tl fixed pattern noise due to local variations in the scintillation light. CsI:Tl fixed pattern noise appears to limit the performance of our current system configurations. All the system configurations are quantum limited at 0.23 {mu}C/kg with two of them having DQE (0) equal to 0.57. Active pixel flat panel imagers are shown to be digital x-ray imagers with almost constant DQE throughout a significant part of their dynamic range and in particular at very low exposures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of CsI:Tl Cyrstal with a Spectrum Matching Photomultiplier Tube

This report documents an effort to improve the energy resolution for a thallium doped cesium iodide (CsI:T1) scintillator paired with a spectrum matching photomultiplier tube (PMT). A comparison of the differences in the pulse height spectra from thallium doped (CsI:T1) and sodium doped (CsI:Na) single crystals with PMTs of different spectrum responses was performed. Results show that energy resolution of the detector only improves 0.5% at room temperature when these scintillators are coupled with a spectrum matching PMT. Based on a spectrum matching PMT, the best results for energy resolution are 7.39% and 7.88% for CsI:T1 and CsI:Na scintillators, respectively. The improvement is primarily attributed to the increase of photon statistics from the increase of photons (N) being detected in the spectrum matching PMT. Other factors, such as optical quantum yield and non-proportionality of the CsI:T1 and CsI:Na crystals, that can affect the energy resolution were also studied and reported. The results indicate that although the use of a spectrum matching PMT enhances the photon statistics, it also exacerbates the nonproportionality response. Consequently, a promised improvement on energy resolution due solely to photon statistics was not fully realized.

36 MATERIALS SCIENCE↗

Review of sustainability indices and indicators: Towards a new City Sustainability Index (CSI)

The purpose of this paper is to discuss conceptual requirements for a City Sustainability Index (CSI) and to review existing major sustainability indices/indicators in terms of the requirements. The following indices are reviewed: Ecological Footprint (EF), Environmental Sustainability Index (ESI), Dashboard of Sustainability (DS), Welfare Index, Genuine Progress Indicator (GPI), Index of Sustainable Economic Welfare, City Development Index, emergy/exergy, Human Development Index (HDI), Environmental Vulnerability Index (EVI), Environmental Policy Index (EPI), Living Planet Index (LPI), Environmentally-adjusted Domestic Product (EDP), Genuine Saving (GS), and some applications of composite indices or/and multivariate indicators to local or regional context as case studies. The key conceptual requirements for an adequate CSI are: (i) to consider environmental, economic and social aspects (the triple bottom line of sustainability) from the viewpoint of strong sustainability; (ii) to capture external impacts (leakage effects) of city on other areas beyond the city boundaries particularly in terms of environmental aspects; (iii) to create indices/indicators originally for the purpose of assessing city sustainability; and (iv) to be able to assess world cities in both developed and developing countries using common axes of evaluation. Based on the review, we conclude that it is necessary to create a new CSI that enables us to assess and compare cities' sustainability performance in order to understand the global impact of cities on the environment and human life as compared with their economic contribution. In the future, the CSI will be able to provide local authorities with guidance toward sustainable paths. - Highlights: Black-Right-Pointing-Pointer We derive the four key requirements for a new City Sustainability Index (CSI) system. Black-Right-Pointing-Pointer First, the triple bottom line must be considered in terms of strong sustainability. Black-Right-Pointing-Pointer Second, environmental leakage effects beyond city boundaries should be captured. Black-Right-Pointing-Pointer Third, 'city sustainability' should be originally considered when CSI is created. Black-Right-Pointing-Pointer Fourth, cities in developed and developing countries can be evaluated without bias.

54 ENVIRONMENTAL SCIENCES↗

CsI(Tl) pulse shape discrimination with the Belle II electromagnetic calorimeter as a novel method to improve particle identification at electron–positron colliders

Here we describe the implementation and performance of CsI(Tl) pulse shape discrimination for the Belle II electromagnetic calorimeter, representing the first application of CsI(Tl) pulse shape discrimination for particle identification at an electron–positron collider. The pulse shape characterization algorithms applied by the Belle II calorimeter are described. Control samples of $γ, μ^+, π^±, K^±$ and $ρ/ \bar{ρ}$ are used to demonstrate the significant insight into the secondary particle composition of calorimeter clusters that is provided by CsI(Tl) pulse shape discrimination. Comparisons with simulation are presented and provide further validation for newly developed CsI(Tl) scintillation response simulation techniques, which when incorporated with GEANT4 simulations allow the particle dependent scintillation response of CsI(Tl) to be modelled. Comparisons between data and simulation also demonstrate that pulse shape discrimination can be a new tool to identify sources of improvement in the simulation of hadronic interactions in materials. The $K^0_L$ efficiency and photon-as-hadron fake-rate of a multivariate classifier that is trained to use pulse shape discrimination is presented and comparisons are made to a shower-shape based approach. CsI(Tl) pulse shape discrimination is shown to reduce the photon-as-hadron fake-rate by over a factor of 3 at photon energies of 0.2 GeV and over a factor 10 at photon energies of 1 GeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temporal resolution limit estimation of x-ray streak cameras using a CsI photocathode

A Monte Carlo model is developed and implemented to calculate the characteristics of x-ray induced secondary electron (SE) emission from a CsI photocathode used in an x-ray streak camera. Time distributions of emitted SEs are investigated with an incident x-ray energy range from 1 to 30 keV and a CsI thickness range from 100 to 1000 nm. Simulation results indicate that SE time distribution curves have little dependence on the incident x-ray energy and CsI thickness. The calculated time dispersion within the CsI photocathode is about 70 fs, which should be the temporal resolution limit of x-ray streak cameras that use CsI as the photocathode material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topological Equivalence of VSI and CSI Commutation Cells and Its Application to Switching Resonance Analysis and Damper Design

This paper proposes the concept of the topological equivalence between the commutation cells of a voltage source inverter (VSI) and a current source inverter (CSI) using duality and equivalent circuit transformation techniques. A switching resonance of CSI is analyzed and an effective three-phase RC damper is derived from the dc-link RC damper of VSIs based on the topological equivalence of the VSI and CSI commutation cells. Furthermore, a new three-phase RC damper design framework utilizing the topological equivalence is proposed. Here, experimental results verify that the proposed three-phase RC damper design for CSI significantly reduces the switching resonance and improves the CSI’s output waveform total harmonics distortions (THDs).

42 ENGINEERING↗

Novel laser-processed CsI:Tl detector for SPECT

Purpose: The aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems. Methods: The scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm{sup 2} and 0.625 × 0.625 mm{sup 2} pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments. Results: The process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved. Conclusions: The results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗