Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsTe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Materials Data on CsTe by Materials Project

CsTe crystallizes in the orthorhombic Pbam space group. The structure is three-dimensional. Cs1+ is bonded in a 8-coordinate geometry to eight equivalent Te1- atoms. There are a spread of Cs–Te bond distances ranging from 3.89–4.30 Å. Te1- is bonded in a 9-coordinate geometry to eight equivalent Cs1+ and one Te1- atom. The Te–Te bond length is 2.83 Å.

36 MATERIALS SCIENCE↗

Downhole laser system with an improved laser output production and data collection

One or more embodiments relates to a method of growing ultrasmooth and high quantum efficiency CsTe photocathodes. The method includes exposing a substrate of Cs using an alkali source such as an effusion cell; and controlling co-evaporating growth and co-deposition forming a CsTe growth. The method further includes monitoring a stoichiometry of the CsTe growth.

Mcintyre, Dustin↗

Downhole laser system with an improved laser output production and data collection

One or more embodiments relates to a method of growing ultrasmooth and high quantum efficiency CsTe photocathodes. The method includes exposing a substrate of Cs using an alkali source such as an effusion cell; and controlling co-evaporating growth and co-deposition forming a CsTe growth. The method further includes monitoring a stoichiometry of the CsTe growth.

McIntyre, Dustin↗

A rare multi-coordinate tellurite, NH{sub 4}ATe{sub 4}O{sub 9}.2H{sub 2}O (A=Rb or Cs): The occurrence of TeO{sub 3}, TeO{sub 4}, and TeO{sub 5} Polyhedra in the same material

Two new tellurites, NH{sub 4}RbTe{sub 4}O{sub 9}.2H{sub 2}O and NH{sub 4}CsTe{sub 4}O{sub 9}.2H{sub 2}O have been synthesized and characterized. The compounds were synthesized hydrothermally, in near quantitative yields, using the alkali metal halide, TeO{sub 2}, and NH{sub 4}OH as reagents. The iso-structural materials exhibit layered, two-dimensional structural topologies consisting of TeO{sub x} (x=3, 4, or 5) polyhedra separated by NH{sub 4}{sup +}, H{sub 2}O, Rb{sup +} or Cs{sup +} cations. Unique to these materials is the presence of TeO{sub 3}, TeO{sub 4}, and TeO{sub 5} polyhedra. Thermogravimetric and infrared spectroscopic data are also presented. Crystal data: NH{sub 4}RbTe{sub 4}O{sub 9}.2H{sub 2}O: Monoclinic I2/a (no. 15), a=18.917(3) A, b=6.7002(11) A, c=21.106(5) A, {beta}=101.813(2){sup o}, V=2618.5(9) A{sup 3}, Z=8; NH{sub 4}CsTe{sub 4}O{sub 9}.2H{sub 2}O: Monoclinic I2/a (no. 15), a=18.9880(12) A, b=6.7633(4) A, c=21.476(2) A, {beta}=102.3460(10){sup o}, V=2694.2(3) A{sup 3}, Z=8. - Graphical abstract: Two unprecedented tellurites, NH{sub 4}ATe{sub 4}O{sub 9}.2H{sub 2}O (A=Rb or Cs) have been synthesized and characterized. The materials represent rare examples of tellurites that contain TeO{sub 3}, TeO{sub 4}, and TeO{sub 5} polyhedra in the same compound. All of the polyhedra are in asymmetric polar coordination environments attributable to their stereo-active lone-pair.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat load of a GaAs photocathode in an SRF electron gun

A great deal of effort has been made over the last decades to develop a better polarized electron source for high energy physics. Several laboratories operate DC guns with a gallium arsenide photocathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved by using a superconducting radio frequency (SRF) electron gun, which delivers beams of a higher brightness than that from DC guns because the field gradient at the cathode is higher. SRF guns with metal and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since a bulk gallium arsenide (GaAs) photocathode is normal conducting, a problem arises from the heat load stemming from the cathode. In this paper, we present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and verification by measuring the quality factor of the gun with and without the cathode at 2 K. We simulate heat generation and flow from the GaAs cathode using the ANSYS program. Finally, by following the findings with the heat load model, we designed and fabricated a new cathode holder (plug) to decrease the heat load from GaAs.

2 K test↗

Environmental test report for the WX-32335 SEC camera tube

The environmental testing activity on the WX-32335 was carried out to determine if this tube type could withstand the environmental requirements established for the International Ultraviolet Explorer (IUE) camera tube (WX-32224). The results of the tests led to the following conclusions: (1) The WX-32335 as processed with a CsTe photocathode surface can withstand the temperature extremes established for the IUE camera tube without damage to the photocathode surface or without introducing background signal in the tube after one hour of dark integration. (2) The WX-32335 built with a WX-32224 type target support structure can withstand the sinusoidal vibration requirements established for the IUE camera tube. (3) Although the vibration test of the WX-32335 type tubes built with the flat target ring structure could not be completed, there was no indication that these tubes could not withstand the sinusoidal vibration requirements established for the IUE camera tube.

Malanoski, R. J.↗

Space Telescope digicon technology

The objective of this program was to develop the technology and construct a number of tubes conforming to the chosen configuration. A total of ten starts were made and ten tubes went through to test. Of the ten tubes three were CsI on LiF, six were CsTe on MgF2 and one was KNaCsSb on SiO2. All three faceplate crystals sealed successfully using indium as the sealant. In addition, a number of test seals were made and two photocathode sample runs were made. The tasks E-field, faceplate, anti-corona and electron optical analysis were actively pursued and the results integrated into the BASD HRS project.

Alting-Mees, H. R.↗

State-of-the-art Space Telescope Digicon performance data

The Digicon has been chosen as the detector for the High Resolution Spectrograph and the Faint Object Spectrograph of the Space Telescope. Both tubes are 512 channel, parallel-output devices and feature CsTe photocathodes on MgF2 faceplates. Using a computer-assisted test facility, the tubes have been characterized with respect to diode array performance, photocathode response (1100-9000 A), and imaging capability. Data are presented on diode dark current and capacitance distributions, pulse height resolution, photocathode quantum efficiency, uniformity and blemishes, dark count rate, distortion, resolution, and crosstalk.

Ginaven, R. O.↗

N2 Lyman-Birge-Hopfield dayglow from ATLAS 1

Spectral measurements of the far ultraviolet dayglow were made from the ATLAS 1 shuttle mission using an intensified charge coupled device (CCD) imaging spectrometer array. The instrument imaged relatively large (177 A) segments of the spectrum simultaneously and had the capability to image altitude in the second dimension of the two-dimensional focal plane detector when the entrance slit of the instrument was oriented perpendicular to the limb of the Earth. The far ultraviolet (FUV) channel of the instrument used a CsTe photocathode rather than the more conventionally used and more solar blind CsI photocathode material. As a result, the spectra were also measured with good sensitivity at FUV wavelengths longer than 1500 A. In this paper, data are selected of specific interest to a study of the N2 Lyman-Birge-Hopfield system using two shuttle attitudes: In the first the field of view was held at a fixed tangent ray height of approximately 140 km while scanning in wavelength, providing repeated FUV spectra over a range of latitudes and allowing comparison with our thermospheric airglow model. In the second observing sequence the line of sight of the instrument was scanned down through the atmosphere but covered about 75% of the full wavelength range. This sequence allows comparison of height dependence,including O2 absorption effects, with the thermospheric model. In all cases, relatively good agreement is obtained with the model (run strictly in a predictive mode) in comparisions in which the line of sight must be intergrated along a path that spans a considerable range of conditions (height, local time, latitude, solar zenith angle). In the case of the data sets examined in this study the vibrational population distributions show mixed results. In one case the distribution agrees well with a theoretical model based on direct electron impact excitation without a significant cascade contribution. A second case indicated a lower population in nu' = 3 and a higher population in nu' = 6 than would be expected from direct impact excitation alone. This supports previous indications that conditions resulting in the cascade mechanism may not always be operative.

Torr, Marsha R.↗

Heat load of a P-doped GaAs photocathode in SRF electron gun

Many efforts were made over the last decades to develop a better polarized electron source for the high energy physics. Several laboratories operate DC guns with the Gallium-Arsenide photo-cathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved using a Superconducting RF electron gun, which delivers beams of higher brightness than DC guns does, because the field gradient at the cathode is higher. SRF guns with metal cathodes and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since the cathode will be normal conducting, the problem about the heat load stemming from the cathode arises. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and the verification by measuring the quality factor of the gun with and without cathode.

43 PARTICLE ACCELERATORS↗