Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsI Photocathode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Temporal resolution limit estimation of x-ray streak cameras using a CsI photocathode

A Monte Carlo model is developed and implemented to calculate the characteristics of x-ray induced secondary electron (SE) emission from a CsI photocathode used in an x-ray streak camera. Time distributions of emitted SEs are investigated with an incident x-ray energy range from 1 to 30 keV and a CsI thickness range from 100 to 1000 nm. Simulation results indicate that SE time distribution curves have little dependence on the incident x-ray energy and CsI thickness. The calculated time dispersion within the CsI photocathode is about 70 fs, which should be the temporal resolution limit of x-ray streak cameras that use CsI as the photocathode material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

The PHENIX Hadron Blind Detector

Dielectron measurements by the PHENIX Experiment at RHIC are limited by the combinatorial background from electrons and positrons which are not produced in the same pair. The Hadron Blind Detector will allow a substantial reduction of this background by correctly identifying dielectrons from photon conversions and pion Dalitz decays which dominate the signal in the low mass region of the spectrum. Triple GEM stacks, with a CsI photocathode deposited on the uppermost GEM, detect Cherenkov light produced by electrons in a CF{sub 4} radiator. The transparency of CF{sub 4}, high quantum efficiency of CsI in the UV, and absence of a window between the gas radiator and the GEMs allow a large photoelectron yield, while minimizing the hadron signal. Results from the HBD in RHIC's Run-7 and preparations for upcoming runs are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-25 ps timing measurements with 10 × 10 cm 2 PICOSEC Micromegas detectors

The PICOSEC Micromegas detector is a precise timing gaseous detector based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplifying structure. First single-pad prototypes demonstrated a time resolution below σ = 25 ps, however, to make the concept appropriate to physics applications, several developments are required. The objective of this work was to achieve an equivalent time resolution for a 10 × 10 cm 2 area PICOSEC Micromegas detector. The prototype was designed, produced and tested in the laboratory and successfully operated with a 80 GeV/c muon beam. Preliminary results for this device equipped with a CsI photocathode demonstrated a time resolution below σ = 25 ps for all measured pads. The time resolution was reduced to be below σ = 18 ps by decreasing the drift gap to 180 μm and using dedicated RF amplifier cards as new electronics. The excellent timing performance of the single-channel proof of concept was not only transferred to the 100-channel prototype, but even improved, making the PICOSEC Micromegas detector more suitable for large-area experiments in need of detectors with high time resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, construction, operation and performance of a Hadron Blind Detector for the PHENIX experiment

A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF{sub 4}. It has a 50 cm long radiator directly coupled in a windowless configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contribution of the HMPID detector to the high-p{sub T} physics at LHC

The LHC will deliver unexplored energy regimes for proton-proton and heavy-ion collisions. As shown by the RHIC experiments, particle identification over a large momentum range is essential to disentangle physics processes, especially in the intermediate p{sub T}(1<p{sub T}<5 GeV/c) region. The novel design of the High-Momentum Particle Identification Detector (HMPID), based on large surface CsI photocathodes, is able to identify {pi}{sup {+-}}, K{sup {+-}}, p and p-bar in the momentum region where bulk medium properties and hard scatterings interplay. Furthermore, measurement of resonance particles such as the {phi}{yields}K{sup +}K{sup -} could provide information on the system evolution. The HMPID layout and segmentation are optimized to study particle correlations at high momenta describing the early phase and the dynamical evolution of the collision. At LHC, the increased hard cross section will significantly be enhanced compared to RHIC. Identified leading particle correlations and jet reconstruction via Deterministic Annealing can address jet quenching and detailed measurements of jet properties. In this paper, we present these selected topics from the possible HMPID contributions to the physics goals of LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Performance Imaging Streak Camera for the National Ignition Facility

An x-ray streak camera platform has been characterized and implemented for use at the National Ignition Facility. The camera has been modified to meet the experiment requirements of the National Ignition Campaign and to perform reliably in conditions that produce high EMI. A train of temporal UV timing markers has been added to the diagnostic in order to calibrate the temporal axis of the instrument and the detector efficiency of the streak camera was improved by using a CsI photocathode. The performance of the streak camera has been characterized and is summarized in this paper. The detector efficiency and cathode measurements are also presented.

Opachich, Y. P.↗

Laboratory reflectometer for the investigation of optical elements in a wavelength range of 5–50 nm: description and testing results

We describe a laboratory reflectometer developed at the IPM RAS for precision measurements of spectral and angular dependences of the reflection and transmission coefficients of optical elements in a wavelength range of 5–50 nm. The radiation is monochromatised using a high-resolution Czerny–Turner spectrometer with a plane diffraction grating and two spherical collimating mirrors. A toroidal mirror focuses the probe monochromatic beam on a sample. The X-ray source is a highly ionised plasma produced in the interaction of a high-power laser beam with a solid target at an intensity of 10{sup 11}–10{sup 12} W cm{sup –2}. To stabilise the emission characteristics, the target executes translatory and rotary motions in such a way that every pulse irradiates a new spot. The short-focus lens is protected from contamination by erosion products with the use of a specially designed electromagnetic system. The samples under study are mounted on a goniometer is accommodated in a dedicated chamber, which provides five degrees of freedom for samples up to 500 mm in diameter and two degrees of freedom for a detector. The sample mass may range up to 10 kg. The X-ray radiation is recorded with a detector composed of a CsI photocathode and two microchannel plates. A similar detector monitors the probe beam intensity. The spectral reflectometer resolution is equal to 0.030 nm with the use of ruled gratings with a density of 900 lines mm{sup –1} (spectral range: 5–20 nm) and to 0.067 nm for holographic gratings with a density of 400 lines mm{sup –1} (spectral range: 10–50 nm). We analyse the contribution of higher diffraction orders to the probe signal intensity and the ways of taking it into account in the measurements. Examples are given which serve to illustrate the reflectometer application to the study of multilayer mirrors and filters. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gaseous photodetectors with solid photocathodes

Remarkable properties of gas photodetectors make them attractive for application in high energy physics, astrophysics, and medical imaging. This review presents the results of research and development of gaseous photodetectors with solid photocathodes (GPDs). In particular, efficient photocathodes for the ultraviolet (mainly CsI) and the visible ranges, including photocathodes with protective dielectric nanofilms, are described. Some problems of the physics of gaseous photodetectors and photocathodes are considered: photoelectron backscattering in gas, photoemission amplification in an electric field, photoelectron transport through nanofilms, protective properties of nanofilms, and photon and ion feedback. A separate section is devoted to GPDs based on gas electron multipliers (GEMs), including sealed GPDs and cryogenic two-phase avalanche detectors with CsI photocathodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hadron blind Cherenkov counters

A Hadron Blind Detector, or HBD, is a novel form of Cherenkov counter that is designed to provide high efficiency for detecting highly relativistic electrons while being essentially blind to most hadrons. Herein, we present some of the most prominent realizations of the HBD concept in real experiments. We describe the first implementation of an HBD that was made in the CERES experiment at CERN using a spectrometer based on a doublet of hadron blind RICH detectors for the measurement of low-mass electron pairs in pA and AA collisions at the SPS. We next present a detailed account of a more extensive realization of the HBD that was made in the PHENIX experiment for the measurement of low-mass electron pairs in central heavy-ion collisions at RHIC, followed by a description of a very similar detector that is currently under construction at J-PARC for the measurement of vector mesons through their e + e – decay in pA collisions. We conclude with a brief discussion of possible evolutions of the HBD concept as well as possible developments and uses of HBDs in experiments at the future Electron Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calibration of a microchannel plate based extreme ultraviolet grazing incident spectrometer at the Advanced Light Source

We present the design and calibration of a microchannel plate based extreme ultraviolet spectrometer. Calibration was performed at the Advance Light Source (ALS) at the Lawrence Berkeley National Laboratory (LBNL). This spectrometer will be used to record the single shot spectrum of radiation emitted by the tapered hybrid undulator (THUNDER) undulator installed at the LOASIS GeV-class laser-plasma-accelerator. The spectrometer uses an aberration-corrected concave grating with 1200 lines/mm covering 11-62 nm and a microchannel plate detector with a CsI coated photocathode for increased quantum efficiency in the extreme ultraviolet. A touch screen interface controls the grating angle, aperture size, and placement of the detector in vacuum, allowing for high-resolution measurements over the entire spectral range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-color spatial and temporal temperature measurements using a streaked soft x-ray imager

A dual-channel streaked soft x-ray imager has been designed and used on high energy-density physics experiments at the National Ignition Facility. This streaked imager creates two images of the same x-ray source using two slit apertures and a single shallow angle reflection from a nickel mirror. Thin filters are used to create narrow band pass images at 510 eV and 360 eV. When measuring a Planckian spectrum, the brightness ratio of the two images can be translated into a color-temperature, provided that the spectral sensitivity of the two images is well known. To reduce uncertainty and remove spectral features in the streak camera photocathode from this photon energy range, a thin 100 nm CsI on 50 nm Al streak camera photocathode was implemented. Provided that the spectral shape is well-known, then uncertainties on the spectral sensitivity limits the accuracy of the temperature measurement to approximately 4.5% at 100 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Measurement of the Scintillation Light Yield in CD4 Using a Photosensitive GEM Detector

The absolute photon yield of scintillation light produced by highly ionizing particles in pure CF{sub 4} has been measured using a photosensitive Gas Electron Multiplier (GEM) detector. The detector consists of two standard GEMs and a CsI coated GEM which acts as a photocathode that is sensitive to the 160 nm scintillation light produced in CF{sub 4}. The light yield was determined in terms of the number of scintillation photons emitted into a 4{pi} solid angle produced per MeV of energy deposited in the gas by a 5.5 MeV alpha particle and found to be 314 {+-} 15 photons per MeV. The quantum yield was determined using a fitting method to determine the number of photoelectrons from the measured pulse height distribution, and by an independent method using the measured gain of the GEM detector. The effect of scintillation light in CF{sub 4} on the performance of Cherenkov detectors, such as the PHENIX Hadron Blind Detector (HBD) at RHIC, is also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗