Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsI Photocathode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quantum efficiencies of imaging detectors with alkali halide photocathodes. I - Microchannel plates with separate and integral CsI photocathodes

Measurements and comparisons have been made of the quantum efficiencies of microchannel plate (MCP) detectors in the far-UV (below 2000-A) wavelength range using CsI photocathodes (a) deposited on the front surfaces of microchannel plates and (b) deposited on solid substrates as opaque photocathodes with the resulting photoelectrons input to microchannel plates. The efficiences were measured in both pulse-counting and photodiode modes of operation. Typical efficiencies are about 15 percent at 1216 A for a CsI-coated MCP compared with 65 percent for an opaque CsI photocathode MCP detector. Special processing has yielded an efficiency as high as 20 percent for a CsI-coated MCP. This may possibly be further improved by optimization of the tilt angle of the MCP channels relative to the front face of the MCP and incident radiation. However, at present there still remains a factor of at least 3 quantum efficiency advantage in the separate opaque CsI photocathode configuration.

Carruthers, George R.↗

Temporal resolution limit estimation of x-ray streak cameras using a CsI photocathode

A Monte Carlo model is developed and implemented to calculate the characteristics of x-ray induced secondary electron (SE) emission from a CsI photocathode used in an x-ray streak camera. Time distributions of emitted SEs are investigated with an incident x-ray energy range from 1 to 30 keV and a CsI thickness range from 100 to 1000 nm. Simulation results indicate that SE time distribution curves have little dependence on the incident x-ray energy and CsI thickness. The calculated time dispersion within the CsI photocathode is about 70 fs, which should be the temporal resolution limit of x-ray streak cameras that use CsI as the photocathode material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum efficiency of opaque CsI photocathodes with channel electron multiplier arrays in the extreme and far ultraviolet

The arrays are overcoated with a CsI photocathode in the VUV. The measurements are part of the development program for the Extreme Ultraviolet Explorer. Monochromatic light from a hollow cathode discharge source passing through a McPherson grazing incidence monochromator is used to illuminate the CsI photocathode. The beam diameter is kept small (approximately 2 mm) to confine it within the individual thickness strips. A bias grid is used to produce a 50-V/mm electric field to guarantee collection of all photoelectrons emitted by the CEMA (channel electron multiplier array) webbing. The CEMAs are operated with a gain of 2-3 x 10 to the 6th and are moderately saturated. A channeltron secondary transfer standard is used to determine the absolute QE in the EUV, whereas an NBS calibrated windowed photodiode is used to measure the FUV absolute QE. It is noted that the CsI gives a factor of 3 increase in the QE in the EUV and a factor of 50-5000 in the FUV.

Martin, C.↗

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

Photon-counting image sensors for the ultraviolet

An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).

Jenkins, E. B.↗

High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

Timothy, J. Gethyn↗

N2 Lyman-Birge-Hopfield dayglow from ATLAS 1

Spectral measurements of the far ultraviolet dayglow were made from the ATLAS 1 shuttle mission using an intensified charge coupled device (CCD) imaging spectrometer array. The instrument imaged relatively large (177 A) segments of the spectrum simultaneously and had the capability to image altitude in the second dimension of the two-dimensional focal plane detector when the entrance slit of the instrument was oriented perpendicular to the limb of the Earth. The far ultraviolet (FUV) channel of the instrument used a CsTe photocathode rather than the more conventionally used and more solar blind CsI photocathode material. As a result, the spectra were also measured with good sensitivity at FUV wavelengths longer than 1500 A. In this paper, data are selected of specific interest to a study of the N2 Lyman-Birge-Hopfield system using two shuttle attitudes: In the first the field of view was held at a fixed tangent ray height of approximately 140 km while scanning in wavelength, providing repeated FUV spectra over a range of latitudes and allowing comparison with our thermospheric airglow model. In the second observing sequence the line of sight of the instrument was scanned down through the atmosphere but covered about 75% of the full wavelength range. This sequence allows comparison of height dependence,including O2 absorption effects, with the thermospheric model. In all cases, relatively good agreement is obtained with the model (run strictly in a predictive mode) in comparisions in which the line of sight must be intergrated along a path that spans a considerable range of conditions (height, local time, latitude, solar zenith angle). In the case of the data sets examined in this study the vibrational population distributions show mixed results. In one case the distribution agrees well with a theoretical model based on direct electron impact excitation without a significant cascade contribution. A second case indicated a lower population in nu' = 3 and a higher population in nu' = 6 than would be expected from direct impact excitation alone. This supports previous indications that conditions resulting in the cascade mechanism may not always be operative.

Torr, Marsha R.↗

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.↗

Large-format electrographic and array detectors for a space Schmidt imaging telescope

Possible optical designs of imaging detectors for the spaceborne Schmidt telescope proposed by Carruthers et al. (1990) are discussed, surveying the currently or potentially available technology. Consideration is given to FUV electrographic detectors of large format (e.g., 120 mm with 10-micron resolution) using CsI photocathodes, the possible extension of the same technology to the mid-UV using Cs2Te instead of CsI, large CCD arrays for the visible and NIR, electron-bombarded CCDs for the FUV and mid-UV, and the data handling and processing requirements of these detectors.

Carruthers, George R.↗

The PHENIX Hadron Blind Detector

Dielectron measurements by the PHENIX Experiment at RHIC are limited by the combinatorial background from electrons and positrons which are not produced in the same pair. The Hadron Blind Detector will allow a substantial reduction of this background by correctly identifying dielectrons from photon conversions and pion Dalitz decays which dominate the signal in the low mass region of the spectrum. Triple GEM stacks, with a CsI photocathode deposited on the uppermost GEM, detect Cherenkov light produced by electrons in a CF{sub 4} radiator. The transparency of CF{sub 4}, high quantum efficiency of CsI in the UV, and absence of a window between the gas radiator and the GEMs allow a large photoelectron yield, while minimizing the hadron signal. Results from the HBD in RHIC's Run-7 and preparations for upcoming runs are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-25 ps timing measurements with 10 × 10 cm 2 PICOSEC Micromegas detectors

The PICOSEC Micromegas detector is a precise timing gaseous detector based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplifying structure. First single-pad prototypes demonstrated a time resolution below σ = 25 ps, however, to make the concept appropriate to physics applications, several developments are required. The objective of this work was to achieve an equivalent time resolution for a 10 × 10 cm 2 area PICOSEC Micromegas detector. The prototype was designed, produced and tested in the laboratory and successfully operated with a 80 GeV/c muon beam. Preliminary results for this device equipped with a CsI photocathode demonstrated a time resolution below σ = 25 ps for all measured pads. The time resolution was reduced to be below σ = 18 ps by decreasing the drift gap to 180 μm and using dedicated RF amplifier cards as new electronics. The excellent timing performance of the single-channel proof of concept was not only transferred to the 100-channel prototype, but even improved, making the PICOSEC Micromegas detector more suitable for large-area experiments in need of detectors with high time resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, construction, operation and performance of a Hadron Blind Detector for the PHENIX experiment

A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF{sub 4}. It has a 50 cm long radiator directly coupled in a windowless configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contribution of the HMPID detector to the high-p{sub T} physics at LHC

The LHC will deliver unexplored energy regimes for proton-proton and heavy-ion collisions. As shown by the RHIC experiments, particle identification over a large momentum range is essential to disentangle physics processes, especially in the intermediate p{sub T}(1<p{sub T}<5 GeV/c) region. The novel design of the High-Momentum Particle Identification Detector (HMPID), based on large surface CsI photocathodes, is able to identify {pi}{sup {+-}}, K{sup {+-}}, p and p-bar in the momentum region where bulk medium properties and hard scatterings interplay. Furthermore, measurement of resonance particles such as the {phi}{yields}K{sup +}K{sup -} could provide information on the system evolution. The HMPID layout and segmentation are optimized to study particle correlations at high momenta describing the early phase and the dynamical evolution of the collision. At LHC, the increased hard cross section will significantly be enhanced compared to RHIC. Identified leading particle correlations and jet reconstruction via Deterministic Annealing can address jet quenching and detailed measurements of jet properties. In this paper, we present these selected topics from the possible HMPID contributions to the physics goals of LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Performance Imaging Streak Camera for the National Ignition Facility

An x-ray streak camera platform has been characterized and implemented for use at the National Ignition Facility. The camera has been modified to meet the experiment requirements of the National Ignition Campaign and to perform reliably in conditions that produce high EMI. A train of temporal UV timing markers has been added to the diagnostic in order to calibrate the temporal axis of the instrument and the detector efficiency of the streak camera was improved by using a CsI photocathode. The performance of the streak camera has been characterized and is summarized in this paper. The detector efficiency and cathode measurements are also presented.

Opachich, Y. P.↗