Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsI Photocathode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quantum efficiencies of imaging detectors with alkali halide photocathodes. I - Microchannel plates with separate and integral CsI photocathodes

Measurements and comparisons have been made of the quantum efficiencies of microchannel plate (MCP) detectors in the far-UV (below 2000-A) wavelength range using CsI photocathodes (a) deposited on the front surfaces of microchannel plates and (b) deposited on solid substrates as opaque photocathodes with the resulting photoelectrons input to microchannel plates. The efficiences were measured in both pulse-counting and photodiode modes of operation. Typical efficiencies are about 15 percent at 1216 A for a CsI-coated MCP compared with 65 percent for an opaque CsI photocathode MCP detector. Special processing has yielded an efficiency as high as 20 percent for a CsI-coated MCP. This may possibly be further improved by optimization of the tilt angle of the MCP channels relative to the front face of the MCP and incident radiation. However, at present there still remains a factor of at least 3 quantum efficiency advantage in the separate opaque CsI photocathode configuration.

Carruthers, George R.↗

Quantum efficiency of opaque CsI photocathodes with channel electron multiplier arrays in the extreme and far ultraviolet

The arrays are overcoated with a CsI photocathode in the VUV. The measurements are part of the development program for the Extreme Ultraviolet Explorer. Monochromatic light from a hollow cathode discharge source passing through a McPherson grazing incidence monochromator is used to illuminate the CsI photocathode. The beam diameter is kept small (approximately 2 mm) to confine it within the individual thickness strips. A bias grid is used to produce a 50-V/mm electric field to guarantee collection of all photoelectrons emitted by the CEMA (channel electron multiplier array) webbing. The CEMAs are operated with a gain of 2-3 x 10 to the 6th and are moderately saturated. A channeltron secondary transfer standard is used to determine the absolute QE in the EUV, whereas an NBS calibrated windowed photodiode is used to measure the FUV absolute QE. It is noted that the CsI gives a factor of 3 increase in the QE in the EUV and a factor of 50-5000 in the FUV.

Martin, C.↗

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

Photon-counting image sensors for the ultraviolet

An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).

Jenkins, E. B.↗

High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

Timothy, J. Gethyn↗

N2 Lyman-Birge-Hopfield dayglow from ATLAS 1

Spectral measurements of the far ultraviolet dayglow were made from the ATLAS 1 shuttle mission using an intensified charge coupled device (CCD) imaging spectrometer array. The instrument imaged relatively large (177 A) segments of the spectrum simultaneously and had the capability to image altitude in the second dimension of the two-dimensional focal plane detector when the entrance slit of the instrument was oriented perpendicular to the limb of the Earth. The far ultraviolet (FUV) channel of the instrument used a CsTe photocathode rather than the more conventionally used and more solar blind CsI photocathode material. As a result, the spectra were also measured with good sensitivity at FUV wavelengths longer than 1500 A. In this paper, data are selected of specific interest to a study of the N2 Lyman-Birge-Hopfield system using two shuttle attitudes: In the first the field of view was held at a fixed tangent ray height of approximately 140 km while scanning in wavelength, providing repeated FUV spectra over a range of latitudes and allowing comparison with our thermospheric airglow model. In the second observing sequence the line of sight of the instrument was scanned down through the atmosphere but covered about 75% of the full wavelength range. This sequence allows comparison of height dependence,including O2 absorption effects, with the thermospheric model. In all cases, relatively good agreement is obtained with the model (run strictly in a predictive mode) in comparisions in which the line of sight must be intergrated along a path that spans a considerable range of conditions (height, local time, latitude, solar zenith angle). In the case of the data sets examined in this study the vibrational population distributions show mixed results. In one case the distribution agrees well with a theoretical model based on direct electron impact excitation without a significant cascade contribution. A second case indicated a lower population in nu' = 3 and a higher population in nu' = 6 than would be expected from direct impact excitation alone. This supports previous indications that conditions resulting in the cascade mechanism may not always be operative.

Torr, Marsha R.↗

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.↗

Large-format electrographic and array detectors for a space Schmidt imaging telescope

Possible optical designs of imaging detectors for the spaceborne Schmidt telescope proposed by Carruthers et al. (1990) are discussed, surveying the currently or potentially available technology. Consideration is given to FUV electrographic detectors of large format (e.g., 120 mm with 10-micron resolution) using CsI photocathodes, the possible extension of the same technology to the mid-UV using Cs2Te instead of CsI, large CCD arrays for the visible and NIR, electron-bombarded CCDs for the FUV and mid-UV, and the data handling and processing requirements of these detectors.

Carruthers, George R.↗

Sub-25 ps timing measurements with 10 × 10 cm 2 PICOSEC Micromegas detectors

The PICOSEC Micromegas detector is a precise timing gaseous detector based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplifying structure. First single-pad prototypes demonstrated a time resolution below σ = 25 ps, however, to make the concept appropriate to physics applications, several developments are required. The objective of this work was to achieve an equivalent time resolution for a 10 × 10 cm 2 area PICOSEC Micromegas detector. The prototype was designed, produced and tested in the laboratory and successfully operated with a 80 GeV/c muon beam. Preliminary results for this device equipped with a CsI photocathode demonstrated a time resolution below σ = 25 ps for all measured pads. The time resolution was reduced to be below σ = 18 ps by decreasing the drift gap to 180 μm and using dedicated RF amplifier cards as new electronics. The excellent timing performance of the single-channel proof of concept was not only transferred to the 100-channel prototype, but even improved, making the PICOSEC Micromegas detector more suitable for large-area experiments in need of detectors with high time resolutions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Far Ultraviolet Imaging Spectrograph for Shuttle

The development of the Far Ultraviolet Imaging Spectrograph (FUVIS) Shuttle sortie missions, is described. Objectives of the experiment are to obtain spatially-resolved far-ultraviolet spectra of extraterrestrial sources, including emission-line and reflection nebulae, diffuse background radiation, extragalactic objects, and comets. The use of fast focal ratio (f/1) Schmidt optics and an opaque CsI photocathode which affords high quantum efficiency in the far-UV provides the maximum possible diffuse source sensitivity. Measured emission line intensities of 5 Rayleighs (or continua of intensity 1 R/A) in 300 sec exposures are expected. The development includes a dedicated pointing platform and a low light level television camera for payload specialist use in target acquisition and guiding.

Carruthers, G. R.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

A position sensitive microchannel photomultiplier for ultraviolet space astronomy

The 25-mm microchannel-plate, position-sensitive UV astronomy photomultiplier tube presented is intended for the EOM-1 Spacelab Mission's FAUST payload and conducts wide-field imaging surveys in the VUV over the 1400-1800-A range. The sealed detector encompasses a CsI photocathode deposited on the inner surface of a MgF2 window, a stack of microchannel plates, and a wedge-and-strip two-dimensional position-sensing anode. Since the wedge-and-strip principle requires only three anode signals, flight electronics can be reduced to three charge amplifiers and three analog-to-digital converters.

Lampton, M.↗

Application of wedge and strip image readout systems to detectors for astronomy

Microchannel plate (MCP) detector systems that use wedge and strip anodes for imaging radiation in the range 50 A to 8000 A are described. Test data, obtained from the calibration of the Extreme Ultraviolet Explorer Satellite detectors and the ARIA EUV aeronomy sensor is presented. The long-term performance characteristics of Z-stack microchannel plates are investigated and it is shown that stable operation is achieved after an initial settling period. Conventional and new anode designs and their potential for increasing the position resolution are discussed. Position resolution of better than 80 microns FWHM has been attained for 50 mm devices, and this is shown to be essentially independent of event location. Image nonlinearity of less than 0.3 percent has been achieved with stability to better than 0.1 percent. Differential nonlinearity of less than 1 percent and stability to better than 1 percent have been obtained. Measurements of the quantum efficiency of a CsI photocathode on an MCP are presented, demonstrating efficiencies as high as 47 percent.

Siegmund, O. H. W.↗