Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Cryogenics Test Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Operational Experience of the NML Cryogenic Plant at the FAST Test Facility

The New Muon Laboratory (NML) cools two individually cryostated superconducting radio frequency (SRF) capture cavities (CC) and one prototype ILC cryomodule (CM) with eight SRF cavities. This complex accelerates electrons at 150 MeV for the Integrable Optics Test Accelerator (IOTA) ring, located at the Fermilab Accelerator Science and Technology (FAST) facility. Since 2019, this R&D accelerator complex has gone through four science runs.

Wallace, T. [Fermilab]

Helium recovery system at IB3a

The increasing need for optimal and sustainable use of cryogenic resources to support Fermilab’s scientific mission has highlighted the necessity of improving the Laboratory’s helium management practices. An assessment of cryogenic test facilities identified the Technical Division’s Industrial Building 3a (IB3A) as a key site requiring upgrades to integrate a helium recovery system. The IB3A facility is essential for characterizing and testing superconductors, cables, and coils for various R&D projects, including the US High-Luminosity LHC Accelerator Upgrade Project (AUP), Mu2e, and other external collaborations. Currently, the facility relies on 500 L helium Dewars and vents the vaporized helium directly into the atmosphere, leading to significant helium loss. Given the non-renewable nature of helium, recovering and reusing this resource is critical for the sustainability of Fermilab’s operations. To address this challenge, a project has been initiated to connect IB3A to an existing helium purification station and refrigeration system located in another building via a dedicated pipeline pass over the roof of several buildings. This solution will enable the efficient capture of vented helium, its transfer to the purification station, and subsequent liquefaction for reuse in future operations. The project includes a detailed design phase, specifying the pipeline route, flow control mechanisms, and integration with the existing cryogenic infrastructure, followed by phased implementation and commissioning. By implementing this pipeline connection and upgrading IB3A, Fermilab aims to significantly reduce helium waste, lower operational costs, and align with its commitment to sustainability. This initiative provides a model for resource-efficient cryogenic operations and reinforces the Laboratory’s capacity to support its science mission for the long term.

Porwisiak, D. [Fermilab]

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42 m small-aperture telescopes and one 6 m large-aperture telescope (LAT), located at an elevation of 5200 m in the Atacama Desert in Chile. At the LAT’s focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Furthermore we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

Astronomical instrumentation

DEVELOPMENT OF TRANSIENT FISSION GAS RELEASE CAPABILITIES TO STUDY HIGH BURNUP COMMERCIAL FUEL PERFORMANCE UNDER LOSS OF COOLANT ACCIDENT CONDITIONS

The contribution of transient fission gas release to the burst behaviour of high burnup fuel during a loss of coolant accident (LOCA) for commercial light water reactors is a complex phenomenon that is not fully understood. During the temperature ramp associated with a LOCA, there is significant, additional transient fission gas release in excess of steady state fission gas release from normal operation. The timing of this release and the various conditions that impact this release warrant further study. To better characterize this phenomenon, a system was developed to capture and characterize fission gas released from irradiated fuel during simulated LOCAs. This system is an upgrade to the existing Oak Ridge National Laboratory Severe Accident Test Station LOCA test apparatus and detects fission gas by gamma counting cryogenically cooled cold traps and by using an online gas mass spectrometer. The examined fuel can be pressurized or open to the furnace atmosphere. The design and operation of this new capability are discussed. Results from the first tests on high burnup fuel are presented. In the initial test, the LOCA relevant transient fission gas release was 5.3% for an unpressurized segment. Post-test microscopy on the tested samples is presented to demonstrate the likely radial source of transient fission gas release.

Harp, Jason

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Evaluation of an x-ray multilayer mirror for radiography at sub-1-keV photon energies

An x-ray multilayer mirror on a spherical substrate designed for near-normal incidence with a photon energy of ~738 eV (F He α ) was procured and tested. This device is intended to be used for in-flight radiography of the shell in inertial confinement fusion experiments with cryogenic targets on the OMEGA laser at the Laboratory for Laser Energetics. Experiments in self-emission on a small (~10 J) laser system showed that the reflectivity of the mirror is high enough to record an image at laser energies as low as 0.1 J. Furthermore, a second set of tests in backlighting geometry on a larger (kJ)-scale, short-pulse laser yielded usable radiographs with laser energies as low as 40 J with a spatial resolution of ~10 μm.

47 OTHER INSTRUMENTATION

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator

Experiment to Investigate the On-set of Transient Fission Gas Release Under Simulated LOCA Conditions

Continuing efforts to better understand the phenomenon of transient fission gas release in irradiated commercial light water reactor fuel undergoing a simulated loss of coolant accident (LOCA) will be discussed in this work. During heating associated with LOCA conditions there is an additional release of fission gas beyond what is typically released during steady state operation. The exact timing of this release could impact the cladding balloon and rupture as the LOCA progresses in an actual accident. Recent experiments performed on the upgraded Severe Accident Test Station at Oak Ridge National Laboratory have expanded the current assessment of transient fission gas release. This system evaluates fission gas release by sweeping fission gas out of the LOCA test furnace and into cryogenically cooled cold traps where radioactive noble gas fission products are measured by gamma spectrometry. Additionally, the sweep gas can be monitored by a gas mass spectrometer to provide additional data on noble gas release and changes in the sweep gas atmosphere during heating. Several different conditions have been evaluated that explored the response of irradiated fuel to different thermal ramp conditions and different overpressure conditions. This further confirmed the impact of an overpressure in suppressing transient fission gas release. Further experiments are planned to evaluate the on-set temperature of transient fission gas release under a known overpressure. This test will progressively step through different temperature conditions while maintaining hydrostatic pressure on the fuel that is representative of high burnup fuel conditions. The available results from this type of testing will be discussed. Post-test microscopy will be compared to other transient fission gas release and standard LOCA tests to further understand the microstructural source of transient fission gas release.

Harp, Jason [ORNL] (ORCID:0000000253458440)

The Untold Story of Building the First Megaton Thermonuclear Fusion Device: The Simple Element and IVY Mike

This report is a research and development engineer’s perspective on the fascinating story of the world’s first megaton-class thermonuclear device, IVY Mike (10.4 Mt). Few modern scientific endeavors have matched the complexity and breadth of scientific achievement in such a short amount of time as IVY Mike. This paper will take a look at the design, engineering, fielding, and execution of the world’s first megaton-class physics experiment by Los Alamos Scientific Laboratory and the birth of industrial liquid hydrogen use spawned by the Cold War effort. Although others have written on aspects of this technical history, they have not benefited from access to the original classified documents used by the present author. The present paper must necessarily omit some technical details that remain classified but represents the most comprehensive summary of the engineering and fabrication of the IVY Mike device in the open literature.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF

Experimental and Computational Study of Weld Drop-Through Hydraulic Effects in Multi-Layer Concentric Pipes Servicing Cryogenic Liquid Hydrogen

The Cryogenic Moderator System (CMS) at the Oak Ridge National Laboratory (ORNL)-Spallation Neutron Source (SNS) supplies liquid hydrogen, through vacuum insulated transfer lines to the moderators. The welding process used to make the transfer lines produces weld drop-through, which can constrict the flow of hydrogen and/or cause thermal bridges between adjacent layers. To ensure proper operation of the CMS it is therefore necessary to conduct a flow test to verify the pressure drop caused by the welds. Measurements in as-built piping sections intended to provide liquid hydrogen service to the SNS-CMS system were performed to test the effect of weld penetrations into the fluid flow area focusing on pressure drop effects. The reference test sections were designed using prototypical piping dimensions, materials and expected penetration welds. A numerical study using Computational Fluid Dynamics (CFD) tools in the transfer lines provided a conversion factor from the pressure drop measured in the lines with water to the expected pressure drop using liquid cryogenic hydrogen. The results show evidence of a maximum pressure drop modification in water of 78 KPa in the tested parts, which scales to liquid hydrogen as PHydrogen = 5.2 KPa. The maximum measured equivalent blockage area percentage was found in the as-built TDM transfer line spool 2 with a value of 31%. The measured values obtained in the as-built transfer lines provided accurate values to estimate the expected total pressure drop in the CMS system providing operational limits for the current recirculatory capacity. The effect of the weld drop-through in hydrogen evacuation capacity scenarios was better evaluated as a result of this study.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018

FGMS-poster

Idaho National Laboratory (INL) performs post irradiation examination (PIE) of tri-structural isotropic (TRISO)-coated particle fuel to help qualify it for high temperature gas cooled reactors. TRISO fuel compacts are re-irradiated in the Neutron Radiography Reactor (NRAD) to generate the short lived fission products needed for fission product release testing. The Fuel Accident Condition Simulator (FACS) furnace and newly added Screen Neutron Irradiated Fuel for Failure (SNIFF) furnace heat the compacts in helium to temperatures of up to 2,000°C, prompting fission product release—predominantly gaseous xenon and krypton isotopes and condensable products such as cesium—from failed particles. These released isotopes are transported to a fission gas monitoring system (FGMS 1 or FGMS 3), where they accumulate in cryogenic cold traps and are quantified using high-purity germanium (HPGe) detectors. The addition of SNIFF and FGMS 3 increases throughput by enabling simultaneous testing of multiple compacts. Furthermore, automated INL developed software provides continuous, near-real time monitoring of fission product inventories and manages the liquid nitrogen cooling of the traps. These system enhancements improve the efficiency, data quality, and testing capacity of TRISO fuel performance evaluations.

07 - ISOTOPES AND RADIATION SOURCES

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology, which combines their signals over a reduced number of wires and amplifiers. Here, in this Letter, we present and demonstrate a multiplexer design optimized for transition-edge sensor bolometers with 1820 sensors per readout unit, a factor of two more than the previous state-of-the-art. The design is optimized for cosmic microwave background imaging applications, and it builds on previous microwave superconducting quantum interference device multiplexers by doubling the available readout bandwidth to the full 4–8 GHz octave. Evaluating the key performance metrics of yield, sensitivity, and crosstalk through laboratory testing, we find an end-to-end operable detector yield of 78%, a typical nearest-neighbor crosstalk amplitude of ∼0.4%, and a median white noise level of 83 pA/$\sqrt{\textrm{Hz}}$ due to the multiplexer, corresponding to an estimated contribution of 4% to the total system noise for a ground-based cosmic microwave background telescope. Additionally, we identify a possible path toward reducing resonator loss for future designs with reduced noise. We expect these developments to alleviate the system complexity, cryogenic requirements, and cost of future large arrays of low temperature detectors.

cosmic microwave background

THERMAL STRUCTURAL AND SHOCK EVENT EVALUATIONS OF THE FUELING PELLET INJECTION SYSTEM FOR ITER

The US is among seven partner nations in a collaborative effort to design, build, and demonstrate fusion’s ability to be a large-scale carbon free energy source. Each country has its own Domestic Agencies (DA) that contribute directly to the ITER project. US ITER, which is a DOE Office of Science project managed by Oak Ridge National Laboratory, is developing world class engineering solutions to the design, construction, and assembly of the burning plasma experiment that can demonstrate the scientific and technological feasibility of fusion. US ITER’s scope includes completing the preliminary and final design, qualifying materials and processes for manufacture and testing, executing manufacturing, and delivering the Fueling Pellet Injection System (FPIS) to the ITER site for assembly. The US-ITER FPIS system is designed to inject cryogenically frozen pellets of deuterium-tritium (D-T) into the plasma. The FPIS has two main functions: 1. Provide a steady supply of deuterium and tritium fuel, 2. Mitigating the impact of edge localized modes on the plasma facing components. The FPIS will have the capability to reside in three port cells within a tritium second barrier containment cask. Each pellet cask contains three flight tubes linking with penetrations on the torus cryopump housing and vacuum vessel (VV): two for the magnetic high field side (HFS) pellet injection and one for the magnetic low field side (LFS) pellet injection. This paper presents results of the thermal-structural analyses of the FPIS flight tube structural components when subjected to various loads such as electromagnetic (EM) loads, nuclear heating, seismic, and operational, and dynamic shock events. The resulting temperatures and stresses under combined conditions have been found to satisfy the design criteria to ensure safe and reliable operation of the FPIS flight tubes within the vacuum vessel.

Martinez, Oscar

Testing of Fusion Machine Components Against Cryogenic Pellet Impacts

Shattered pellet injection (SPI), currently the most effective method of disruption mitigation, is currently implemented on tokamaks worldwide for experimental purposes. Cryogenic pellets are formed and fired into an angled surface before entering the plasma. The impact with the angled surface causes the pellets to fragment into a cloud of particles with the purpose of increasing the surface area for ablation. As pellets traverse guide tubes, depending on design, there is a chance of an off-normal pellet impact. Pellet impacts are also, depending on design, possible in the plasma chamber if not fully ablated and assimilated, or if the fragment plume is not directed in the proper direction. This paper outlines a series of pellet impact tests on various tiles and components relevant to the ITER, JET, and ASDEX Upgrade SPI systems. In conclusion, testing was done to assess the potential damage from pellet and fragment plume impacts through high-speed imaging and the visual inspection of components.

Cryogenic pellets

Control of microphonics for a superconducting radio-frequency photo-injector cryomodule

A superconducting radio-frequency photo-injector cryomodule is being developed for the high-energy upgrade of the Linac Coherent Light Source (LCLS-II-HE). This effort is a collaboration between the Facility for Rare Isotope Beams at Michigan State University (MSU), Argonne National Laboratory, Helmholtz-Zentrum Dresden-Rossendorf, and SLAC National Accelerator Laboratory. The cryomodule features a 185.7 MHz superconducting quarter-wave resonator (QWR) designed to operate with an RF electric field of 30 MV/m at the photo-cathode. Mechanical vibrations must be controlled for operation with stable amplitude and phase. The first prototype cryomodule was cold-tested at MSU with a QWR, fundamental power coupler, tuner, and cathode stalk. In the cold test, we observed microphonics that made it difficult to control the RF phase at high gradient. The cryogenic circuit was identified as a likely culprit. This paper presents our studies of microphonics during the cryomodule cold test and follow-up investigations at room temperature. Our findings provided valuable feedback for modifications to the cryogenic circuit and a successful second cold test of the cryomodule.

Accelerator Physics

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation

Inferring performance metrics for laser direct drive experiments on OMEGA

Quantifying performance improvements on the OMEGA laser facility requires robust inference of established no-alpha performance metrics, which requires, at minimum, a model to infer the shocked fuel mass and pressure of the confined fusion plasma. In this work, we describe the methodology used to infer performance metrics on OMEGA and present the current state-of-the art model used to infer these metrics from OMEGA experiments. In particular, since neutron images of cryogenic implosions are not available on OMEGA at present, we present how x-ray sizes are determined on OMEGA using a Gaussian Process regression model and how the neutron production region's size is inferred from them. As a result, we end by benchmarking the model using synthetic data and 1-D LILAC simulations and test its experimental self-consistency across available x-ray diagnostic channels.

Gopalaswamy, V. [Laboratory for Laser Energetics,