Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Cryogenic system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

History, status and future applications of spaceborne cryogenic systems

Cryogenic cooling is employed for an increasing number of space instruments. Cryogenic cooling is needed to provide the required detector response, reduce preamplifier noise, and/or reduce background radiation. Cryogenic cooling is required by instruments employed for applications missions, gamma-ray and X-ray astronomy, cosmic ray measurements, space surveillance, IR astronomy, relativity measurements, superconductivity devices, and basic research experiments. The cooling is provided with the aid of radiant coolers, stored solid cryogen coolers, stored liquid-helium coolers, mechanical coolers, He-3 coolers, adiabatic demagnetization, refrigeration, and higher temperature adsorption and magnetic systems. Radiant coolers will continue to find widespread application for low cooling-load/high-temperature situation. It is pointed out that a long-lifetime closed-cycle, mechanical cooler is one of the most critical space technological needs.

Sherman, A.

Cryogenic fluid management (base R/T): Cryogenic fluid systems, Cryogenic Orbital Nitrogen Experiment (CONE), Cryogenic Orbital Hydrogen Experiment (COHE). (Transportation focused technology)

The topics presented are covered in viewgraph form. The concluded remarks are: (1) advanced cryogenic fluid systems technology is enhancing or enabling to all known transportation scenarios for space exploration; (2) an integrated/coordinated program involving LeRC/MSFC has been formulated to address all known CFM needs - new needs should they develop, can be accommodated within available skills/facilities; (3) all required/experienced personnel and facilities are finally in place - data from initial ground-based experiments is being collected and analyzed - small scale STS experiments are nearing flight - program is beginning to yield significant results; (4) future proposed funding to primarily come from two sources; and (5) cryogenic fluid experimentation is essential to provide required technology and assure implementation in future NASA missions.

Symons, Pat

Cryogenic systems for the large deployable reflector

There are five technologies which may have application for Large Deployable Reflector (LDR), one passive and four active. In order of maturity, they are passive stored cryogen systems, and mechanical, sorption, magnetic, and pulse-tube refrigerators. In addition, deep space radiators will be required to reject the heat of the active systems, and may be useful as auxiliary coolers for the stored cryogen systems. Hybrid combinations of these technologies may well be more efficient than any one alone, and extensive system studies will be required to determine the best trade-offs. Stored cryogen systems were flown on a number of missions. The systems are capable of meeting the temperature requirements of LDR. The size and weight of stored cryogen systems are proportional to heat load and, as a result, are applicable only if the low-temperature heat load can be kept small. Systems using chemisorption and physical adsorption for compressors and pumps have received considerable attention in the past few years. Systems based on adiabatic demagnetization of paramagnetic salts were used for refrigeration for many years. Pulse-tube refrigerators were recently proposed which show relatively high efficiency for temperatures in the 60 to 80 K range. The instrument heat loads and operating temperatures are critical to the selection and design of the cryogenic system. Every effort should be made to minimize heat loads, raise operating temperatures, and to define these precisely. No one technology is now ready for application to LDR. Substantial development efforts are underway in all of the technologies and should be monitored and advocated. Magnetic and pulse-tube refrigerators have high potential.

Mason, Peter V.

Progress report on the infrared astronomical satellite cryogenic system

The main cryogen tank is sized to hold 70 kg of superfluid helium with 12 percent ullage at a temperature of 1.8 K. The insulation system surrounds the main cryogen tank with four blankets of multilayer insulation spaced by means of three vapor-cooled shields. It is noted that the multilayer insulation is 6.4 micron double-aluminized Mylar separated by polyester net. The main shell provides the primary structural integrity of the system. In orbit the main shell is cooled to 170 K using insulation blankets on one side and second surface paint on the opposite side. The aperture cover subassembly is the vacuum seal for the main shell during operation on the ground. It is also a gas condensation trap before and during cooldown of the main cryogen tank during launch hold. It contains 6 kg of supercritical helium, which permits 14 days on orbit with a 48-hour launch pad hold.

Urbach, A. R.

Design concepts for the ASTROMAG cryogenic system

Described is a proposed cryogenic system used to cool the superconducting magnet for the Space Station based ASTROMAG Particle Astrophysics Facility. This 2-meter diameter superconducting magnet will be cooled using stored helium II. The paper presents a liquid helium storage concept which would permit cryogenic lifetimes of up to 3 years between refills. It is proposed that the superconducting coil be cooled using superfluid helium pumped by the thermomechanical effect. It is also proposed that the storage tank be resupplied with helium in orbit. A method for charging and discharging the magnet with minimum helium loss using split gas-cooled leads is discussed. A proposal to use a Stirling cycle cryocooler to extend the storage life of the cryostat will also be presented.

Green, M. A.

Design concepts for the ASTROMAG cryogenic system

Described is a proposed cryogenic system used to cool the superconducting magnet for the Space Station based ASTROMAG Particle Astrophysics Facility. This 2-meter diameter superconducting magnet will be cooled using stored helium II. The paper presents a liquid helium storage concept which would permit cryogenic lifetimes of up to 3 years between refills. It is proposed that the superconducting coil be cooled using superfluid helium pumped by the thermomechanical effect. It is also proposed that the storage tank be resupplied with helium in orbit. A method for charging and discharging the magnet with minimum helium loss using split gas-cooled leads is discussed. A proposal to use a Stirling cycle cryocooler to extend the storage life of the cryostat will also be presented.

Green, M. A.

Lessons from commissioning of the cryogenic system for the Short-Baseline Neutrino Detector at Fermilab

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector is installed in a 200 m3 membrane cryostat filled with liquid argon, which serves both as target and as active media. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions while the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector is operated in Booster Neutrino Beams (BNB) at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The cryostat and the cryogenic systems also serve as prototypes for the much larger equipment to be used for the LBNF/DUNE experiment. Since its installation in 2018-2023 and cooldown in spring of 2024, the cryostat and the cryogenic system have been commissioned to support the detector operations. The lessons learned through installation, testing, commissioning, cooldown, and initial operations are described.

Geynisman, Michael [Fermilab]

Lessons from commissioning of the cryogenic system for the Short-Baseline Neutrino Detector at Fermilab

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector is installed in a 200 m$^3$ membrane cryostat filled with liquid argon, which serves both as target and as active media. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions while the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector is operated in Booster Neutrino Beams (BNB) at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The cryostat and the cryogenic systems also serve as prototypes for the much larger equipment to be used for the LBNF/DUNE experiment. Since its installation in 2018-2023 and cooldown in spring of 2024, the cryostat and the cryogenic system have been commissioned to support the detector operations. The lessons learned through installation, testing, commissioning, cooldown, and initial operations are described.

43 PARTICLE ACCELERATORS

A PC-based collapse factor analysis for high pressure cryogenic systems

A collapse factor simulation computer program, suitable for use on personal computers, for supercritical cryogen system pressurization is examined. The available literature is previewed, individual component models are developed, and the overall simulation program logic is examined. Extensive use is made of existing thermodynamic and transport property evaluation packages. Heat transfer is estimated using natural convection correlations, and transient wall heat conduction is considered. Examples of the simulation are demonstrated for two facilities. Partial validation is achieved by comparing the simulation output with data from an existing test facility. Preliminary results indicate that the collapse factors will seldom exceed 1.15 during supercritical operation of high-pressure cryogenic systems. Recommendations for improvements in the component models and the simulation are made.

Hodge, B. K.

Composite, vacuum-jacketed tubing replaces bellows in cryogenic systems

For reliability control of high pressure cryogenic systems, one or more 90 degree elbow expansion devices are substituted for the metal bellows normally used. The device consists of a conducting tube inside a support tube, with the space between the tubes evacuated for insulation.

Calvert, H. F.

Lynx X-Ray Microcalorimeter Cryogenic System

The Lynx x-ray microcalorimeter instrument on the Lynx X-ray Observatory requires a state-of-the-art cryogenic system to enable high-precision and high-resolution x-ray spectroscopy. The cryogenic system and components described provide the required environment using cooling technologies that are already at relatively high technology readiness levels and are progressing toward flight-compatible subsystems. These subsystems comprise a cryostat, a 4.5-K mechanical cryocooler, and an adiabatic demagnetization refrigerator that provides substantial cooling power at 50 mK.

DiPirro, Michael

Low-Heat-Leak Electrical Leads For Cryogenic Systems

Electrical leads offering high electrical conductivity and low thermal conductivity developed for use in connecting electronic devices inside cryogenic systems to power supplies, signal-processing circuits, and other circuitry located in nearby warmer surroundings. Strip of superconductive leads on ceramic substrate, similar to ribbon cable, connects infrared detectors at temperature of liquid helium with warmer circuitry. Electrical leads bridging thermal gradient at boundary of cryogenic system designed both to minimize conduction of heat from surroundings through leads into system and to minimize resistive heating caused by electrical currents flowing in leads.

Wise, Stephanie A.

Spacelab 2 infrared telescope cryogenic system

The paper discusses the development of a cryogenic helium system to provide cooling to a scanning infrared telescope for the Spacelab 2 mission. The infrared optical/detector system and related electronics are being developed by the Smithsonian Astrophysical Observatory and the University of Arizona. A superfluid helium dewar and porous plug phase separator permit gas cooling of the infrared focal plane assembly to about 2.5 K, and of the two telescope sections to 8 K and 60 K. The design of the cryogenic system,including a commandable vacuum cover, and the prelaunch liquid helium servicing and maintenance approach were discussed. It is concluded that the system will satisfy the Infrared Telescope requirements, and the superfluid helium system shall be capable of satisfying cryogenic helium cooled requirements for the next several years.

Urban, E. W.

IRAS cryogenic system flight performance report

It is pointed out that the Infrared Astronomical Satellite (IRAS) is the first telescope to perform observations in the far infrared from orbit. IRAS was launched on January 25, 1983 into a 900 km orbit. The use of the first large superfluid helium dewar in space makes it possible to provide a 2 K telescope environment for an anticipated period of one year. A description of the cryogenic system of IRAS is presented, taking into account the superfluid helium tank, the insulation system, the vacuum shell, the aperture cover, and the fluid management system. The dynamic performance of the cryogenic system is considered along with aspects of prelaunch preparations. Details of flight performance are also discussed, giving attention to transient performance, and steady state performance.

Urbach, A. R.

Study of an all SFHE SIRTF cryogenic system

The Space Infrared Telescope Facility (SIRTF) is a superfluid helium cooled, 85-cm telescope with three infrared instruments at the focal plane. SIRTF will establish in space a long-term-maintainable infrared observatory for the region of 2-700 microns. The cryogenic system can be designed to last up to six years with 1280 kg of superfluid, and can function in either a 28.5 deg or 98 deg inclination orbit by exchanging the sunshade. The lifetime is primarily a function of instrument heat load rather than parasitic heat to the cryogen system.

Urbach, A. R.

Estimating Transient Pressure Surges in Cryogenic Systems

Potentially-damaging pressure waves anticipated and, therefore, avoided. Mathematical model developed for prediction of pressure behavior in single-and two-phase cryogenic systems. Transient liquid-flow analysis modified to incorporate behavior of vapor bubbles and used to predict maximum pressure in cryogenic transfer systems consisting of complex pipe and valve arrangements under both steady-state and transient conditions. Simulation compared favorably with data obtained during transfer of liquid oxygen from ground storage tanks to Space Shuttle orbiter external tanks. Program written in FORTRAN 77 for batch execution.

Pfister, P.