Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Cryogenic Piping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Jacketed cryogenic piping is stress relieved

Jacketed design of piping used to transfer cryogenic fluids, relieves severe stresses associated with the temperature gradients that occur during transfer cycles and ambient periods. The inner /transfer/ pipe is preloaded in such a way that stress relief takes place automatically as cycling occurs.

Bowers, W. M.

Cryogenic piping material selection for the Component Test Facility (CTF)

The anticipated high cost of the 8500 psi cryogenic and 15,000 psi gas piping systems used in the CTF at NASA's John C. Stennis Space Center led to the consideration of high-strength materials for these piping systems. Based on years of satisfactory service using austenitic stainless steels in cryogenic applications, particularly for hydrogen service, consideration was limited to the austenitic stainless steels. Attention was focused on alternatives to the 304/304L grades of stainless steel traditionally used in these applications. This paper discusses the various considerations that resulted in the decision to continue using 304/304L for the cryogenic piping and the selection of the nitrogen-strengthened 21Cr-6Ni-9Mn alloy (UNS S21903) for the high-pressure gas systems at the CTF.

St. Cyr, William W.

Thermal Performance of Cryogenic Piping Multilayer Insulation in Actual Field Installations

A standardized way of comparing the thermal performance of different pipelines in different sizes is needed. Vendor data for vacuum-insulated piping are typically given in heat leak rate per unit length (W/m) for a specific diameter pipeline. An overall k-value for actual field installations (k(sub oafi)) is therefore proposed as a more generalized measure for thermal performance comparison and design calculation. The k(sub oafi) provides a direct correspondence to the k-values reported for insulation materials and illustrates the large difference between ideal multilayer insulation (MLI) and actual MLI performance. In this experimental research study, a section of insulated piping was tested under cryogenic vacuum conditions, including simulated spacers and bending. Several different insulation systems were tested using a 1-meter-long cylindrical cryostat test apparatus. The simulated spacers tests showed significant degradation in the thermal performance of a given insulation system. An 18-meter-long pipeline test apparatus is now in operation at the Cryogenics Test Laboratory, NASA Kennedy Space Center, for conducting liquid nitrogen thermal performance tests.

Fesmire, J.

Universal Two-Phase Convection Heat Transfer Correlations for Cryogenic Pipe Chilldown

This paper presents a set of universal two-phase convection heat transfer correlations for modeling boiling heat transfer during pipe chilldown fit over the widest available range of cryogenic fluids and thermodynamic conditions. The correlations improve upon prior correlations that were developed separately for liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching datasets. The new correlations include equations to calculate the single-phase vapor heat transfer, film boiling heat transfer, transition boiling heat transfer, nucleate boiling heat transfer, single-phase liquid heat transfer, bulk vapor temperature during high quality film boiling, Leidenfrost temperature, critical heat flux, critical heat flux temperature, and the onset of nucleate boiling temperature. The correlations were validated against LH2, LN2, liquid methane, liquid oxygen, and liquid argon pipe quenching datasets. The eight datasets cover the following parameter ranges: pipe lengths of 0.1 to 6.5m; outer pipe diameters of 12.7 to 25.4 mm; pipe wall thicknesses from 0.51 to 1.64 mm; flow directions of upward, downward, and horizontal; gravity levels of 1g and 0g±0.01g. A numerical model assumes homogeneous mixing between the vapor and liquid and implicitly integrates the coupled energy equations for the pipe and fluid, as well as continuity for the fluid. The model was used to estimate the equilibrium quality and fluid mass accumulation along the pipes during chilldown from estimates of the fluid-pipe heat transfer extracted from temperature measurements. The correlations can be implemented in lumped parameter codes such as SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP) to improve the accuracy of chilldown time and chilldown boiloff mass predictions. Such predictions are useful for designing ground or in-space cryogenic liquid transfer systems.

Universal Correlations

Insulating Cryogenic Pipes With Frost

Crystallized water vapor fills voids in pipe insulation. Small, carefully controlled amount of water vapor introduced into dry nitrogen gas before it enters aft fuselage. Vapor freezes on pipes, filling cracks in insulation. Ice prevents gaseous nitrogen from condensing on pipes and dripping on structure, in addition to helping to insulate all parts. Industrial applications include large refrigeration plants or facilities that use cryogenic liquids.

Stephenson, J. G.

Thermal Performance Testing Of Cryogenic Piping Systems

Thermal performance measurement of piping systems under actual field conditions is important for space launch development and commercial industry. Knowledge of the true insulating effectiveness is needed in system design, development, and research activities. A new 18-meter-long test apparatus for cryogenic pipelines has been developed. Three different pipelines, rigid or flexible, can be tested simultaneously. Critical factors in heat leak measurements include eliminating heat transfer at end connections and obtaining proper liquid saturation condition. Effects due to variations in the external ambient conditions like wind, humidity, and solar radiation must be minimized. The static method of liquid nitrogen evaporation has been demonstrated, but the apparatus can be adapted for dynamic testing with cryogens, chilled water, or other working fluids. This technology is suited for the development of an industry standard test apparatus and method. Examples of the heat transfer data from testing commercially available pipelines are given. Prototype pipelines are currently being tested and evaluated at the Cryogenics Test Laboratory of NASA Kennedy Space Center.

Fesmire, J. E.

Performance of the Cryogenic Heat Pipe Experiment

The Cryogenic Heat Pipe (CRYOHP) Experiment has been designed to test two cryogenic heat pipes independently in a micro-gravity environment. The CRYOHP experiment is manifested for flight aboard the shuttle (STS-53) which is scheduled for launch in November, 1992. This paper presents the design of this experiment and the thermal vacuum verification test results. A correlation of the test data and the planned mission operations are also provided.

Brennan, Patrick J.

The Cryogenic Test Bed experiments: Cryogenic heat pipe flight experiment CRYOHP (STS-53). Cryogenic two phase flight experiment CRYOTP (STS-62). Cryogenic flexible diode flight experiment CRYOFD

This paper presents an overview of the Cryogenic Test Bed (CTB) experiments including experiment results, integration techniques used, and lessons learned during integration, test and flight phases of the Cryogenic Heat Pipe Flight Experiment (STS-53) and the Cryogenic Two Phase Flight Experiment (OAST-2, STS-62). We will also discuss the Cryogenic Flexible Diode Heat Pipe (CRYOFD) experiment which will fly in the 1996/97 time frame and the fourth flight of the CTB which will fly in the 1997/98 time frame. The two missions tested two oxygen axially grooved heat pipes, a nitrogen fibrous wick heat pipe and a 2-methylpentane phase change material thermal storage unit. Techniques were found for solving problems with vibration from the cryo-collers transmitted through the compressors and the cold heads, and mounting the heat pipe without introducing parasitic heat leaks. A thermally conductive interface material was selected that would meet the requirements and perform over the temperature range of 55 to 300 K. Problems are discussed with the bi-metallic thermostats used for heater circuit protection and the S-Glass suspension straps originally used to secure the BETSU PCM in the CRYOTP mission. Flight results will be compared to 1-g test results and differences will be discussed.

Thienel, Lee

Cryogenic Vacuum Insulation for Vessels and Piping

Cryogenic vacuum insulation systems, with proper materials selection and execution, can offer the highest levels of thermal performance. Three areas of consideration are vital to achieve the optimum result: materials, representative test conditions, and engineering approach for the particular application. Deficiency in one of these three areas can prevent optimum performance and lead to severe inefficiency. Materials of interest include micro-fiberglass, multilayer insulation, and composite arrangements. Cylindrical liquid nitrogen boil-off calorimetry methods were used. The need for standard thermal conductivity data is addressed through baseline testing. Engineering analysis and design factors such as layer thickness, density, and practicality are also considered.

Kogan, A.

Design and performance of a Cryogenic Heat Pipe Experiment (CRYOHP)

The Cryogenic Heat Pipe Experiment which is designed to demonstrate the thermal performance of two different axially grooved oxygen heat pipes in microgravity is discussed. The CRYOHP is manifested for flight aboard STS-53. The first heat pipe design is based on an extrapolated 0-g transport capability of about 20 W-m with oxygen in the range of 80-100 K. The second heat pipe design permits 0-g 'dry-out' in the CRYOHP and offers improved ground testability for 1-g correlation.

Beam, Jerry

Arterial and grooved cryogenic heat pipes.

Tests were conducted on two cryogenic heat pipes using nitrogen as the working fluid. Both pipes are 1.27 cm in diameter. The first pipe is 141 cm long and uses longitudinal grooves in the aluminum wall as the wick structure. The second pipe is 91 cm long and has an arterial wick adjacent to the wall. In addition, circumferential screw threads are machined along the entire length of the inside pipe wall. Both heat pipes primed with no difficulty in the horizontal position. Start-up after burn-out was obtained repeatedly. However, more testing is required to determine whether the artery pipe is as reliable as the grooved pipe with respect to priming. Once primed, the artery heat pipe is much less sensitive to elevation than the grooved design and, consequently, offers a significant advantage with respect to ground testing. Heat-transfer characteristics of the two pipes were comparable, with both pipes achieving the initial goal of 1000 watt-cm of heat-transport capability.

Brennan, P.

An Advanced Loop Heat Pipe for Cryogenic Applications

A loop heat pipe (LHP) is a very versatile heat transfer device which can transport a large heat load over a long distance with a small temperature difference. All LHPs currently servicing orbiting spacecraft are designed to operate in the room temperature range. Future space telescopes and space-based Earth resource imaging satellites require passive cryogenic heat transport devices that can thermally couple remote cryocoolers to sensor or instrument of interest while providing the capability of payload vibration/jitter isolation, implementation of redundant coolers, and coupling of multiple sensors to a common heat sink. All of these requirements can be satisfied by using a cryogenic LHP (CLHP). Although the development of CLHPs faces several technical challenges, NASA Goddard Space Flight Center has devoted extensive efforts in developing CLHP technology over the past decade and has made significant progress. In particular, the combination of the innovative ideas of using a secondary capillary pump to manage the parasitic heat gain and using a hot reservoir to reduce the system pressure under the ambient condition has led to the successful development of the CLHP. Several CLHPs charged with nitrogen and hydrogen were built and tested in thermal vacuum chambers. These CLHPs demonstrated reliable start-up and robust operation during power cycle and sink temperature cycle tests.

Loop Heat Pipes

An Advanced Loop Heat Pipe for Cryogenic Applications

A loop heat pipe (LHP) is a very versatile heat transfer device that can transport a large heat load over a long distance with a small temperature difference. All LHPs currently servicing orbiting spacecraft are designed to operate in the room temperature range. Future space telescopes and space-based Earth resource imaging satellites require passive cryogenic heat transport devices that can thermally couple remote cryocoolers to sensor or instrument of interest while providing the capability of payload vibration jitter isolation, implementation of redundant coolers, and coupling of multiple sensors to a common heat sink. All of these requirements can be satisfied by using a cryogenic LHP (CLHP). Although the development of CLHPs faces several technical challenges, NASA Goddard Space Flight Center has devoted extensive efforts in developing CLHP technology over the past decade and has made significant progress. In particular, the combination of the innovative ideas of using a secondary capillary pump to manage the parasitic heat gain and using a hot reservoir to reduce the system pressure under the ambient condition has led to the successful development of the CLHP. Several CLHPs charged with nitrogen and hydrogen were built and tested in thermal vacuum chambers. These CLHPs demonstrated reliable start-up and robust operation during power cycle and sink temperature cycle tests.