Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Correlation filters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mapping considerations for optimal binary correlation filters

The optimality of correlation filters is an important issue in applications of pattern recognition. Both binary phase-only filters (BPOFs) and amplitude encoded binary phase-only filters (AE BPOFs) are considered and the results of optimizing the filters for a real world object (the Space Shuttle) are studied. It is found that while only small improvements result from optimizing a BPOF, optimization of the AE BPOF is quite important in obtaining a useful correlation function. In the case of an AE BPOF, both signal-to-noise and peak-to-sidelobe measures must be studied. Computer simulation and experimental correlation results are presented.

Downie, John D.↗

Three field tests of a gas filter correlation radiometer

Test flights to remotely measure nonurban carbon monoxide (CO) concentrations by gas filter correlation radiometry are discussed. The inferred CO concentrations obtained through use of the Gas Filter Correlation Radiometer (GFCR) agreed with independent measurements obtained by gas chromatography air sample bottle analysis to within 20 percent. The equipment flown on board the aircraft, the flight test procedure, the gas chromatograph direct air sampling procedure, and the GFCR data analysis procedure are reported.

Campbell, S. A.↗

Optical calculation of correlation filters

A method is presented for designing optical correlation filters based on measuring intensity patterns in the Fourier plane. The method can be used in general to design any type of frequency plane filter but is especially attractive in the case of a binary phase only filter (BPOF). The method can produce a filter that is well matched to both the object, its transforming optical system and the spatial light modulator used in the correlator input plane. A working filter was produced using the technique, but the filter response was weak. The suspected causes of the weak output are imprecise Fourier plane positioning, nonlinearities in the recording process, and/or aliasing effects.

Knopp, Jerome↗

Optical calculation of correlation filters for a robotic vision system

A method is presented for designing optical correlation filters based on measuring three intensity patterns: the Fourier transform of a filter object, a reference wave and the interference pattern produced by the sum of the object transform and the reference. The method can produce a filter that is well matched to both the object, its transforming optical system and the spatial light modulator used in the correlator input plane. A computer simulation was presented to demonstrate the approach for the special case of a conventional binary phase-only filter. The simulation produced a workable filter with a sharp correlation peak.

Knopp, Jerome↗

Correlation Filtering of Modal Dynamics using the Laplace Wavelet

Wavelet analysis allows processing of transient response data commonly encountered in vibration health monitoring tasks such as aircraft flutter testing. The Laplace wavelet is formulated as an impulse response of a single mode system to be similar to data features commonly encountered in these health monitoring tasks. A correlation filtering approach is introduced using the Laplace wavelet to decompose a signal into impulse responses of single mode subsystems. Applications using responses from flutter testing of aeroelastic systems demonstrate modal parameters and stability estimates can be estimated by correlation filtering free decay data with a set of Laplace wavelets.

Freudinger, Lawrence C.↗

Optimal Correlation Filters for Images with Signal-Dependent Noise

We address the design of optimal correlation filters for pattern detection and recognition in the presence of signal-dependent image noise sources. The particular examples considered are film-grain noise and speckle. Two basic approaches are investigated: (1) deriving the optimal matched filters for the signal-dependent noise models and comparing their performances with those derived for traditional signal-independent noise models and (2) first nonlinearly transforming the signal-dependent noise to signal-independent noise followed by the use of a classical filter matched to the transformed signal. We present both theoretical and computer simulation results that demonstrate the generally superior performance of the second approach in terms of the correlation peak signal-to-noise ratio.

Downie, John D.↗

Gas filter correlation radiometry: Report of panel

To measure the concentration of a gas in the troposphere, the gas filter radiometer correlates the pattern of the spectral lines of a sample of gas contained within the instrument with the pattern of the spectral lines in the upwelling radiation. A schematic diagram of a generalized gas filter radiometer is shown. Three instruments (the Gas Filter Radiometer, GFR; the Halogen Occultation Experiment, HALOE; and the Gas Filter Correlation Spectrometer, GASCOFIL) that have application to remotely measuring tropospheric constituents are described. A set of preliminary calculations to determine the feasibility of performing a multiple-layer, tropospheric carbon monoxide measurement experiment was performed. It can be seen that a three-layer measurement in the troposphere is possible.

Reichle, Henry G., Jr.↗

Sensitivity of gas filter correlation instrument to variations in optical balance

A computer program was used to simulate the response of the Gas Filter Correlation Radiometer (GFCR) to changing pollutant levels of CO, SO2, CH4, and NH3 in two model atmospheres. Positive and negative deviations of tau sub alpha of magnitudes 0.01, 0.1, and 1 percent were imposed upon the simulation and the resulting deviations in inferred concentrations were determined. For the CO, CH4, and the higher pressure cell of the NH3 channel, the deviations are less than + or - 12 percent for deviations in tau sub alpha of + or - 0.1 percent, but increase to significantly higher values for larger deviations. For the lower pressure cell of NH3 and for SO2, the deviations in inferred concentration begin to rise sharply between 0.01 and 0.1 percent deviation in tau sub alpha, suggesting that a tighter control on tau sub alpha may be required for these channels.

Orr, H. D., III↗

A gas filter correlation monitor for CO, CH4, and HCl

A fast response instrument for monitoring the atmospheric constituents CO, CH4, and HCl, using a modified nondispersive infrared technique, was designed, assembled, and tested. This gas filter correlation method uses a sample of gas to provide a selective filter for radiation absorbed in a gas mixture containing the specified gas. Depending on the spectral line broadening, temperature, and optical depth of the gas selected, exceptionally high spectral resolution may be attained. A description of the single beam rotating cell system and its specific application is presented along with the signal processing circuit. Calibrations of the instrument show that the technique can be used to measure CO, CH4, and HCl concentrations as small as 5 ppm-m. A field version was employed to measure diurnal variations of CO and CH4 and the interfering effects of other atmospheric gases were analyzed.

Sebacher, D. I.↗

A modular radiative transfer program for gas filter correlation radiometry

The fundamentals of a computer program, simulated monochromatic atmospheric radiative transfer (SMART), which calculates atmospheric path transmission, solar radiation, and thermal radiation in the 4.6 micrometer spectral region, are described. A brief outline of atmospheric absorption properties and line by line transmission calculations is explained in conjunction with an outline of the SMART computational procedures. Program flexibility is demonstrated by simulating the response of a gas filter correlation radiometer as one example of an atmospheric infrared sensor. Program limitations, input data requirements, program listing, and comparison of SMART transmission calculations are presented.

Casas, J. C.↗

Non-mechanical optical path switching and its application to dual beam spectroscopy including gas filter correlation radiometry

A non-mechanical optical switch is developed for alternately switching a monochromatic or quasi-monochromatic light beam along two optical paths. A polarizer polarizes light into a single, e.g., vertical component which is then rapidly modulated into vertical and horizontal components by a polarization modulator. A polarization beam splitter then reflects one of these components along one path and transmits the other along the second path. In the specific application of gas filter correlation radiometry, one path is directed through a vacuum cell and one path is directed through a gas correlation cell containing a desired gas. Reflecting mirrors cause these two paths to intersect at a second polarization beam splitter which reflects one component and transmits the other to recombine them into a polarization modulated beam which can be detected by an appropriate single sensor.

Sachse, Glen W.↗

Comparison of eye-safe solid state laser DIAL with passive gas filter correlation measurements from aircraft and spacecraft

Differential Absorption Lidar (DIAL) using solid state Ti:sapphire lasers finds current application in the NASA/LASE Project for H2O vapor measurements in the approximately = 0.820 micron region for the lower and mid-troposphere and in potential future applications in planned measurements of the approximately = 0.940 micron region where both strong and weak absorption lines enables measurements throughout the troposphere and lower stratosphere. The challenge exists to perform measurements in the eye-safe greater than 1.5 micron region. A comparison between DIAL and passive Gas Filter Correlation Radiometer (GFCR) measurements is made. The essence of the differences in signal to noise ratio for DIAL and passive GFCR measurements is examined. The state of the art of lasers and optical parametric oscillators (OPO's) is discussed.

Hess, Robert V.↗

Optimal binary phase and amplitude correlation filters for polarization-rotating spatial light modulators

We investigate the optimal designs of binary phase and amplitude filters (BPAFs) for the key correlation metrics of peak intensity, peak-to-correlation energy, SNR, and discrimination. These filters may be implemented on binary polarization-rotating spatial light modulators. We present simulation results comparing performance to conventional binary phase-only filters (BPOFs) and illustrating trade-offs between the different performance criteria in terms of the filter design parameter. We also extend the generalization to three-level phase and amplitude filters with a nonzero region of support and demonstrate that optimal three-level BPAFs can provide clearly superior performance to optimal three-level BPOFs.

Downie, John D.↗

Lensless matched spatial filter correlator experiments

By combining a matched spatial filter and holographic optical element on a single plate, a compact optical frequency plane correlator results. Experimental pattern recognition correlation data and a theoretical analysis with experimental verification of the system's shift invariance are provided.

Shen, M.↗

Design of optimal correlation filters for hybrid vision systems

Research is underway at the NASA Johnson Space Center on the development of vision systems that recognize objects and estimate their position by processing their images. This is a crucial task in many space applications such as autonomous landing on Mars sites, satellite inspection and repair, and docking of space shuttle and space station. Currently available algorithms and hardware are too slow to be suitable for these tasks. Electronic digital hardware exhibits superior performance in computing and control; however, they take too much time to carry out important signal processing operations such as Fourier transformation of image data and calculation of correlation between two images. Fortunately, because of the inherent parallelism, optical devices can carry out these operations very fast, although they are not quite suitable for computation and control type operations. Hence, investigations are currently being conducted on the development of hybrid vision systems that utilize both optical techniques and digital processing jointly to carry out the object recognition tasks in real time. Algorithms for the design of optimal filters for use in hybrid vision systems were developed. Specifically, an algorithm was developed for the design of real-valued frequency plane correlation filters. Furthermore, research was also conducted on designing correlation filters optimal in the sense of providing maximum signal-to-nose ratio when noise is present in the detectors in the correlation plane. Algorithms were developed for the design of different types of optimal filters: complex filters, real-value filters, phase-only filters, ternary-valued filters, coupled filters. This report presents some of these algorithms in detail along with their derivations.

Rajan, Periasamy K.↗

Optimal real correlation filters

Expressions are derived for real filters that have a maximum correlation signal to noise ratio. Both continuous and discrete cases are treated and shown to have similar forms. The signal can be complex, and the case of a real signal is considered and related to previous results.

Juday, Richard D.↗

Correlation filters for orientation estimation

An important task in many vision applications is that of rapidly estimating the orientation of an object with respect to some frame of reference. Because of their speed and parallel processing capabilities, optical correlators should prove valuable in this application. This paper considers two algorithms for object orientation estimation based on optical correlations and presents some initial simulation results.

Kumar, B. V. K. Vijaya↗

A gas filter correlation analyzer for methane

A fast-response instrument for monitoring CH4 was designed and tested using a modified nondispersive infrared technique. An analysis of the single-beam rotating-cell system is presented along with the signal processing circuit. A calibration of the instrument shows that the technique can be used to measure CH4 concentrations as small as 5 ppm-m and the effects of interfering gases are analyzed.

Sebacher, D. I.↗