Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contact angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interference fringe (IF) technique for droplet contact angle and thickness measurements: Ultralow contact angle and nanoscale thickness measurement

Recently, reflection interference fringe (RIF) and transmission fringe (TIF) techniques have been introduced to investigate the origin of far-field interference fringe (IF) formation and to determine a droplet's contact angle and thickness by measuring the fringe radius. In this study, characteristics of the IF technique are analyzed based on the RIF and TIF by varying the schematics, such as configuration (transmission/reflection), the droplet's side (left-hand side/right-hand side), and the substrate types (flat/prism). The analysis also investigates the refraction effect at the droplet edge and the maximum incidence and contact angles. The schematic variation shows that the widest contact angle range can be measured in a transmission configuration with droplet's right-hand side, and that the fringe radius decreases with incidence angles on a prism substrate, consistent with the recent observation. Refraction at the droplet edge causes the fringe radius to increase or decrease depending on the degree of refraction. Based on the characteristics study, it is revealed that the IF technique can determine nanometer-scale thicknesses below 100 nm on droplets, corresponding to ultra-small contact angles of less than 0.01°, with an extended working distance of 3000 mm and an optimized incidence angle, assuming a spherical profile. This finding is significant, as it demonstrates that the nanoscale thickness can be determined in situ under ambient conditions using a simple optical configuration, without requiring a sophisticated setup, such as a microscope. It is anticipated that the IF technique can be combined with other nanoscale thickness measurement techniques to enhance its measurement reliability.

36 MATERIALS SCIENCE↗

Multiscale water drop contact angles at selected silica surfaces

In this paper, multiscale advancing contact angles for glycerol/water drops at silica surfaces are reported for millidrops, submicron-drops, and nanodrops. Selected silica surfaces were muscovite, silicon, and talc. The contact angles for millidrops (1–2 mm) were determined by the traditional sessile drop technique. For submicron-drops (0.1–1.0 μm), a hollow tip Atomic Force Microscope (AFM) procedure was used. The contact angles for nanodrops (~7 nm) were examined from Molecular Dynamics (MD) simulation. The results were compared to evaluate the effect of drop size on the contact angle. In the case of the hydrophobic talc surface, the 75° advancing contact angle did not vary significantly with drop size. For the hydrophilic muscovite surface, the water drop wet the surface and an advancing contact angle of about 10° was found for the millidrops and submicron-drops. However, for the MD simulated nanodrops, attachment and spreading of the ~7 nm drop created a 2D film of molecular dimensions, the contact angle of which was difficult to define and varied from 0° to 17°. Perhaps of equal interest from the MD simulation results was that the spreading of the glycerol/water nanodrop at the muscovite surface resulted in crystallographic directional transport of water molecules to the extremities of the 2D film. Such separation and segregation left the center of the film with an increased concentration of glycerol. Based on these results, the line tension, which has been found in other investigations to account for contact angle decrease with a decrease in drop size, does not seem to be a significant factor in this study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental measurement of the effective contact angle for solvent/packing interactions in a structured packed column for CO 2 capture

The contact angle is a critical factor for determining the effective mass transfer area for carbon dioxide (CO 2 ) capture via the chemical absorption process in a packed column, and thus the overall capture efficiency of the packed column. Many widely used commercial packings involve microscale features (perforation, corrugation, etc.) that may also affect the wetting behavior. This study proposes a systematic method of using a modified Wilhelmy plate to measure the effective contact angle to characterize the solvent and featured packing interaction. In lieu of computational efforts relying on assumptions guided by semi-informed correlation, the proposed method directly measures the effective contact angle as a function of the solvent and packing thermophysical and hydrodynamic properties. The characterization of the effective contact angle is then integrated in the computational fluid dynamics modeling to reduce uncertainty in the prediction of effective mas transfer area. Experiments were conducted for stainless steel coupons using water and aqueous sodium hydroxide (NaOH) solvent for verification of the proposed experimental protocol. The surface tension of the aqueous NaOH solvent was altered using surfactant and antifoam. The effective contact angle increases with the increased value of the surface tension for flat stainless steel sheets. On the other hand, effective contact angles do not vary in Mellapak coupons for aqueous monoethanolamine (MEA) and NaOH solvent. In this case, surface textures and sheet design play a dominant role in the surface tension of solvents. Furthermore, CO 2 loading has a significant effect on the contact angle for Mellapak coupons. As expected, the contact angle decreases with the increasing temperature of CO 2 capture solvents (MEA, EEMPA). The effective contact angle measurement using the Wilhelmy plate method can provide more accurate and efficient solvents for characterizing the solvent-packing surface interactions. Subsequently, the present method enhances the accuracy of the prediction of the effective mass transfer area in carbon capture by solvent absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lattice Boltzmann Modeling of Drying of Porous Media Considering Contact Angle Hysteresis

Drying of porous media is governed by a combination of evaporation and movement of the liquid phase within the porous structure. Contact angle hysteresis induced by surface roughness is shown to influence multi-phase flows, such as contact line motion of droplet, phase distribution during drainage and coffee ring formed after droplet drying in constant contact radius mode. However, the influence of contact angle hysteresis on liquid drying in porous media is still an unanswered question. Lattice Boltzmann model (LBM) is an advanced numerical approach increasingly used to study phase change problems including drying. In this paper, based on a geometric formulation scheme to prescribe contact angle, we implement a contact angle hysteresis model within the framework of a two-phase pseudopotential LBM. The capability and accuracy of prescribing and automatically measuring contact angles over a large range are tested and validated by simulating droplets sitting on flat and curved surfaces. Afterward, the proposed contact angle hysteresis model is validated by modeling droplet drying on flat and curved surfaces. Then, drying of two connected capillary tubes is studied, considering the influence of different contact angle hysteresis ranges on drying dynamics. Finally, the model is applied to study drying of a dual-porosity porous medium, where phase distribution and drying rate are compared with and without contact angle hysteresis. The proposed model is shown to be capable of dealing with different contact angle hysteresis ranges accurately and of capturing the physical mechanisms during drying in different porous media including flat and curved geometries.

36 MATERIALS SCIENCE↗

Are Contact Angle Measurements Useful for Oxide-Coated Liquid Metals?

This work establishes that static contact angles for gallium-based liquid metals have no utility despite the continued and common use of such angles in the literature. In the presence of oxygen, these metals rapidly form a thin (~1–3 nm) surface oxide “skin” that adheres to many surfaces and mechanically impedes its flow. This property is problematic for contact angle measurements, which presume the ability of liquids to flow freely to adopt shapes that minimize the interfacial energy. We show here that advancing angles for a metal are always high (>140°)—even on substrates to which it adheres—because the solid native oxide must rupture in tension to advance the contact line. The advancing angle for the metal depends subtly on the substrate surface chemistry but does not vary strongly with hydrophobicity of the substrate. During receding measurements, the metal droplet initially sags as the liquid withdraws from the “sac” formed by the skin and thus the contact area with the substrate initially increases despite its volumetric recession. Furthermore, the oxide pins at the perimeter of the deflated “sac” on all the surfaces are tested, except for certain rough surfaces. With additional withdrawal of the liquid metal, the pinned angle gets smaller until eventually the oxide “sac” collapses. Thus, static contact angles can be manipulated mechanically from 0° to >140° due to hysteresis and are therefore uninformative. We also provide recommendations and best practices for wetting experiments, which may find use in applications that use these alloys such as soft electronics, composites, and microfluidics.

36 MATERIALS SCIENCE↗

Modeling Contact Angle vs. Temperature for the Quartz-Water-Decane System

Innovative approaches are needed to improve the efficiency of oil recovery technologies to meet the growing demands of fossil-fuel based energy consumption. Enhanced oil recovery (EOR) methods such as low-salinity waterflooding and chemically tuned waterflooding aim to optimize the reservoir’s wetting properties, detaching oil globules from rock surfaces and allowing easier oil flow through pore throats. This wetting behavior is commonly quantified by contact angle measurements of the rock-oil-brine interface, which have been thoroughly investigated and theorized for many systems at ambient temperatures and pressures. However, few studies exist for extending contact angle theories away from ambient conditions. In this paper, we model the contact angles of a quartz-water-decane system at elevated temperatures using the surface tension component (STC) approach. Temperature-dependent van der Waals [Lifshitz-van der Waals (LW)] interactions and hydrogen-bonding (acid-base) interactions were calculated and are incorporated into the model for the quartz-water-decane interface. Additionally, the Hough and White procedure was used to create temperature-dependent dielectric functions of quartz, water, and normal decane for calculations of Hamaker coefficients. Hamaker coefficients calculated this way are highly linear with temperature and agree well with Israelachvili’s approximation. The acid-base interactions likely contribute the most to system wettability changes. Resulting contact angles of the quartz-water-decane system shift from water-wet (16°) to slightly water-wet (57.4°) as temperature increases. The model was also successfully verified for the quartz-air-water system. Our results can be used in future studies to determine optimal injected water compositions for specific rock-oil-brine and other systems with consideration of reservoir temperature.

02 PETROLEUM↗

Implementing contact angle boundary conditions for second-order Phase-Field models of wall-bounded multiphase flows

In the present work, a general formulation is proposed to implement the contact angle boundary conditions for the second-order Phase-Field models, which is applicable to N-phase (N ≥ 2) moving contact line problems. To remedy the issue of mass change due to the contact angle boundary condition, a source term or Lagrange multiplier is added to the original second-order Phase-Field models, which is determined by the consistent and conservative volume distribution algorithm so that the summation of the order parameters and the consistency of reduction are not influenced. To physically couple the proposed formulation to the hydrodynamics, especially for large-density-ratio problems, the consistent formulation is employed. The reduction-consistent conservative Allen-Cahn models are chosen as examples to illustrate the application of the proposed formulation. The numerical scheme that preserves the consistency and conservation of the proposed formulation is employed to demonstrate its effectiveness. Results produced by the proposed formulation are in good agreement with the exact and/or asymptotic solutions. The proposed method captures complex dynamics of moving contact line problems having large density ratios.

97 MATHEMATICS AND COMPUTING↗

Optimizing Aluminum Bonding: Exploring Surface Roughness and Contact Angle Effects through Plasma and Acid Etching Contrasts

The use of adhesives to replace traditional techniques like welding and riveting has been on the rise in various industries as increasingly complex geometries and situations for bonding is required. It’s well known in the scientific community that an adhesive bond is only as efficient as the surface preparation used beforehand. Plasma treatments have been shown to gently clean the surface by only removing the top-most layer from the adherend and “charging” the surface instead of berating it. Whereas chemical treatments “etch” the surface in hopes of increasing surface area by increasing surface roughness. This method can be difficult to control quantitatively and can generate waste leading to serious environmental concerns. This study aims to address the encountered differences between plasma treatments and acid etching on aluminum substrates for adhesive bonding. Treating the surface of adherends plays a crucial role in promoting a good bond between adhesive and adherend. In this study, the effects of plasma and acid treatments are categorized using surface roughness measurements as well as contact angle which have been shown to correlate to mechanical strength. When evaluating different surface treatments, it is notable to mention that not only surface roughness and contact angle play a role in determining which method is most effective but also the consequences of the treatment itself. It was found that although chemical etching was the most effective in increasing roughness and decreasing contact angle, it generates a large amount of waste and is not sustainable compared to plasma work which uses a renewable process. The results from this work provide a deeper understanding of the relationship between surface treatments and surface roughness/contact angle and how this relates to a stronger adhesive bond.

36 MATERIALS SCIENCE↗

Optimizing Aluminum Bonding: Exploring Surface Roughness and Contact Angle Effects through Plasma and Acid Etching Contrasts.

The use of adhesives to replace traditional techniques like welding and riveting has been on the rise in various industries as increasingly complex geometries and situations for bonding is required. It’s well known in the scientific community that an adhesive bond is only as efficient as the surface preparation used beforehand. Plasma treatments have been shown to gently clean the surface by only removing the top-most layer from the adherend and “charging” the surface instead of berating it. Whereas chemical treatments “etch” the surface in hopes of increasing surface area by increasing surface roughness. This method can be difficult to control quantitatively and can generate waste leading to serious environmental concerns. This study aims to address the encountered differences between plasma treatments and acid etching on aluminum substrates for adhesive bonding. Treating the surface of adherends plays a crucial role in promoting a good bond between adhesive and adherend. In this study, the effects of plasma and acid treatments are categorized using surface roughness measurements as well as contact angle which have been shown to correlate to mechanical strength. When evaluating different surface treatments, it is notable to mention that not only surface roughness and contact angle play a role in determining which method is most effective but also the consequences of the treatment itself. It was found that although chemical etching was the most effective in increasing roughness and decreasing contact angle, it generates a large amount of waste and is not sustainable compared to plasma work which uses a renewable process. The results from this work provide a deeper understanding of the relationship between surface treatments and surface roughness/contact angle and how this relates to a stronger adhesive bond

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Pressure-Dependent Interfacial Tension and Contact Angle on Capillary Heterogeneity Trapping of CO2 in Storage Aquifers

Summary Carbon dioxide (CO2) capillary trapping increases the total amount of CO2 that can be effectively immobilized in storage aquifers. This trapping, manifesting itself as accumulated CO2 columns at a continuum scale, is because of capillary threshold effects that occur below low-permeability barriers. Considering that capillary pressure is dictated by heterogeneous pore throat size, the trapped CO2 column height and associated CO2 saturation will vary spatially within a storage aquifer. This variation will be influenced by two pressure-dependent interfacial parameters—CO2/brine interfacial tension (IFT) and CO2/brine/rock contact angle. Our objective is to understand how the pressure dependence of these two parameters affects the heterogeneity of capillary trapped CO2 at a continuum scale. Our conceptual model is a 1D two-zone system with the upper zone being a flow barrier (low permeability) and the lower zone being a flow path (high permeability). The inputs to this model include microfacies-dependent capillary pressure vs. saturation curves and permeability values. The input capillary pressure curves were collected in the literature that represents carbonate microfacies (e.g., dolograinstone) in a prevalent formation in the Permian Basin. We then used the Leverett j-function to scale the capillary pressure curve for the two zones that are assigned with the same or different microfacies. During scaling, we considered the influence of pressure on both the IFT and contact angle of CO2/brine/dolomite systems. We varied the zone permeability contrast ratio from 2 to 50. We then assumed capillary gravity equilibriums and calculated the CO2 saturation buildup corresponding to various trapped CO2 column heights. The CO2 saturation buildup is defined as the CO2 saturation in the lower layer minus that in the upper one. We found that the saturation buildup can be doubled when varying pressure in a storage aquifer, after considering pressure-dependent IFT and contact angles. Thus, assuming these two parameters to be constant across such aquifers would cause large errors in the quantification of capillary trapping of CO2. The whole study demonstrates the importance of considering pressure-dependent interfacial properties in predicting the vertical distribution of capillary trapped CO2. It has important implications in developing a better understanding of leakage risks and consequent storage safety.

Engineering↗

Evaluation of Stripping Resistance of Organoclay-Modified Asphalt Binder and Aggregate Systems Using an Optical Contact Angle Analyzer

Organoclays, often referred to as nanoclays (NCs), are organically modified phyllosilicates. They are derived from naturally occurring clay minerals and possess unique characteristics in improving the physical and mechanical properties of polymers and rubbers. Recently, NCs have drawn interest in the modification of asphalt binders as micro-scale fillers. A few recent studies have revealed that the addition of NCs in asphalt binders improved binders’ stiffness, aging characteristics, and fatigue resistance. This study aims to evaluate the changes in moisture resistance of different NC-modified asphalt binders through the surface free energy (SFE) technique. This technique estimates SFE properties of binders and aggregates from static contact angle (SCA) data measured from an optical contact angle analyzer (OCA). Further, this study examines the changes in chemical compositions (functional groups) of binders due to the addition of selected NCs by using the Fourier Transformation Infrared (FTIR) technique. To this end, a commonly used performance grade (PG) binder (PG 64-22) modified with four different types (shape and size) of NCs, namely, Cloisite® 15 (C-15), Cloisite® 20 (C-20), Cloisite® Na+ (C-Na), and Cloisite® Ca++ (C-Ca) were evaluated in this study. The SFE data of five different types of aggregates from Oklahoma, namely, Davis Limestone (DL), Snyder Granite (SG), Dolese-Cooperton Limestone (DCL), Hanson-Davis Rhyolite (HDR), and Martin-Marietta-Mill-Creek Granite (MMMG), were used to perform their compatibility with the aforementioned NC-modified binders. The FTIR spectra revealed the presence of various alcohols, ethers, and esters in NC-modified asphalt binders. The moisture susceptibility analysis shows that the addition of NC results in an increase of SFE and cohesive energy of an asphalt binder, which are desired for improved moisture resistance. The addition of NC also shows improved compatibility in cases of all aggregates. Among the five aggregates, MMMCG showed the highest compatibility with all binders, followed by DCL, HDR, DL, and SG. In regard to NCs, the C-15 sample showed the highest compatibility followed by C-20, C-Na, and C-Ca.

Hossain, Zahid↗

Application of unsupervised deep learning to image segmentation and in-situ contact angle measurements in a CO 2 -water-rock system

Rock surface wettability is a critical property that regulates multiphase flows in porous media, which can be quantified using the surface contact angle (CA). X-ray micro-computed tomography (μCT) provides an effective approach to in-situ measurements of surface CAs. However, the CA measurement accuracy depends significantly on the quality of CT image segmentation, which is the clustering of CT pixels into separate phases. Inspired by this, we developed a deep learning (DL)-based CA measurement workflow. Motivated by the recent tremendous progress in unsupervised learning techniques and aiming to avoid expensive manual data annotations, an unsupervised DL pipeline for CT image segmentation was proposed and implemented, which includes unsupervised model training and post-processing. The unsupervised model training was driven by a novel loss function constrained with feature similarity and spatial continuity and implemented by iterative forward and backward paths; the former clustered the pixel-wise feature vectors extracted by convolution neural networks, whereas the latter updated the parameters using gradient descent. An over-segmentation strategy was adopted for model training. The post-processing steps based on agglomerative hierarchical clustering (AHC) were implemented to further merge the over-segmented model output to the desired cluster number, which is intended to improve the efficiency of image segmentation. The developed unsupervised DL pipeline was compared with other commonly-used image segmentation methods using pixel-wise and physics-based evaluation metrics on a synthetic raw-image dataset, which had a known ground truth. The unsupervised DL pipeline showed the best performance. Next, the segmented images were input to an automatic CA measurement tool, and the results were validated by comparisons with manual measurements. The CA values from the manual and automatic measurements showed similar distributions and statistical properties. The automatic measurement demonstrated a wider spectrum because of the much larger number of measurement data points. The primary novelty of the unsupervised DL pipeline developed in this study lies in the novel loss function and the over-segmentation strategy associated with AHC post-processing. Finally, the workflow has been proven an efficient tool for pore-scale wettability characterization, which has a wide range of applications in fundamental studies of multiphase flows in natural porous media, which have critical implications to geological carbon sequestration, hydrocarbon energy recovery, and contaminant transport in groundwater.

42 ENGINEERING↗

Measurement of Resistance, Porosity, and Water Contact Angle of Porous Transport Layers for Low-Temperature Electrolysis Technologies

The porous transport layer is an important component of low-temperature electrolysis devices, such as proton exchange membrane water electrolyzers or anion exchange membrane water electrolyzers. PTLs have significant influence on the cell performance as their bulk resistance can impact the ohmic resistance, their contact resistance can impact electrode performance, and their structure can impact the liquid flow to the cell, which could cause mass-transport losses. In order to improve cell performance, optimization of the PTL is critical. Standardized protocols should be utilized to adequately compare PTLs being developed from different institutions. This method will detail a standardized protocol for measuring the resistance of the PTL using a four-wire setup and will also detail a process for measuring the porosity and water contact angle of the PTL using capillary flow porometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modulating the Contact Angle between Nonpolar Polymers and SiO 2 Nanoparticles

Polymer–nanoparticle interactions play an important role in determining the morphology and properties of polymer nanocomposites and controlling the polymeric reactions involving heterogeneous catalysts. Here, in this study, we modulate the interactions between nonpolar polymers and nanoparticles by modifying the nanoparticle surface chemistry and quantify the interaction strength through direct contact angle measurements. We investigate the interactions of three nonpolar polymers, polystyrene, polyethylene, and polycyclooctene, with silica nanoparticles whose surface chemistry has been modified by atomic layer deposition of titania and calcium carbonate and by alkyl silanization. Significant differences in polymer–nanoparticle interactions are observed, which can be attributed to differences in the polarizability of the polymers and oxide surface composition. Compared to fully hydrogenated polycyclooctene, polycyclooctene is shown to have stronger interactions with most metal oxides; however, this trend is reversed following alkyl silanization of the silica nanoparticles, which makes the surface of the particles less polar. These differences in interactions can be leveraged to make polymer nanocomposites with unique properties and enable the selective conversion of polymers without the need for separations.

36 MATERIALS SCIENCE↗

Investigation of chemical stabilities and contact angle of 3D printed polymers with CO 2 capture solvents to enhance absorber performance

Increasing absorption rate in aqueous amine CCS systems is one avenue to decrease capital cost by reducing the overall size of the absorber column. One potential route is by replacing conventional steel packing with custom designed packing made from 3D printed polymers. 3D printing offers endless flexibility in packing designs to better enhance liquid/gas contact, increase CO 2 mass transfer and create compact absorber columns. Additionally, before exploring novel packing designs, it is necessary to identify polymer materials that can be 3D printed while also showing long-term physical and surface property stability upon exposure to corrosive amine solutions. Four polymers that are commonly used for 3D printing were evaluated using CO 2 -loaded amine solution at temperatures typically observed in the absorber column. Three polymers, high-density polystyrene (HDPS), acrylonitrile butadiene styrene (ABS) and nylon were found to be physically stable after 5000 hr of amine exposure at temperatures up to 60 °C. The contact angle (wetting) of water and CO 2 -loaded aqueous amine solution on the polymer surfaces were also stable after exposure to the CO2-loaded amine solution.

36 MATERIALS SCIENCE↗