An alternative method of changing the pulse duration in a stretcher-compressor pair by changing the gas pressure in the compressor

The relatively narrow bandwidth of neodymium glass requires a much larger stretch ratio of chirped-pulse amplification (CPA) systems. This factor, together with a large incident angle on the gratings, makes glass CPA systems extremely sensitive to the refractive index of the medium in the stretcher-compressor. High sensitivity of the stretcher-compressor pair for hybrid optical parametric chirped-pulse amplification and an Nd:glass laser to the refractive index was demonstrated in air, vacuum, and carbon dioxide, and a pulse duration close to the transform limit was reached. An alternative way to change the pulse duration was proposed. The pulse duration from the best compression of 500 fs to 30 ps was smoothly varied by changing the air pressure from 10 -6 Torr to 1 atm in the compressor and up to 52 ps in carbon dioxide, while the stretcher and compressor remained untouched. Finally, excellent agreement of the measured pulse duration with theoretical calculations was demonstrated.

47 OTHER INSTRUMENTATION

Enabling Robust Compressor Operation Under Various sCO 2 Conditions at Compressor Inlet

The supercritical carbon dioxide (sCO 2 ) power cycle is one of the most investigated power conversion systems in last decade. The reason for this is its wide range of potential applications from fossil fuels (Natural gas), nuclear (Fusion, Fission), through concentrated solar power, energy storage system and waste heat recovery systems to power-to-x systems. The main advantage of the sCO 2 power cycle is very similar operation conditions, especially for the compressor, for all potential applications. Because of this the potential cost of the system can be reduced. However, the sCO 2 power cycle has still several issue that needs to address before commercial application. The current key issue is design of the primary compressor. The primary compressor is one of the key components in the sCO 2 power cycle; it operates with inlet conditions just above the critical point of CO 2 to maintain high fluid density and reduce power requirements.

14 SOLAR ENERGY

Characterization of Inlet Guide Vane Performance for Discharge Compressor Operation near the Dome of an sCO 2 Pumped Heat Energy Storage

Southwest Research Institute® (SwRI®) developed and tested a Variable Inlet Guide Vane (IGV herein) assembly on an integrally-geared sCO 2 compressor (IGC) to demonstrate compressor operation at both the compressor design point and near the dome and to define the operating limits of the compressor by monitoring for two-phase flow, flow turbulence from the IGVs, and compressor choke and surge as the CO 2 inlet temperature is varied. Performance testing was conducted on an existing integrally-geared, two-stage main compressor designed for near-critical-point operation with CO 2 . This testing campaign validated the IGV design and operation, as well as improved the understanding and confidence in operating compressors and predicting performance characteristics near the critical point where fluid properties change rapidly with temperature. In addition to improving the robust operating limits of an sCO 2 compressor, the development of an IGV for the IGC system improved off-design compressor efficiency by 12%.

25 ENERGY STORAGE

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat

Cold compressor performance and energy consumption improvements at Jefferson Lab’s Central Helium Liquefiers

Abstract Jefferson Lab operates two central helium liquefiers (CHLs) which both utilize full cold compression from the saturation pressure at operating temperature (approximately 2.1 K) to just over atmospheric pressure. The original plant, CHL1, was recently outfitted with a replacement subatmospheric cold box (SC1R) containing state-of-the-art cold compressor technology, while the newer plant, CHL2, uses an older cold compressor system. In both cases, the heat of compression is absorbed at low temperature at the expense of electrical power consumed by the warm compressors. Due to the superior efficiency and turndown capabilities of SC1R, a new operating mode has been identified for CHL1 in which the required number of operating warm compressors is reduced by one. A cost-based method for optimizing cold compressor stability and efficiency has been developed and applied to CHL2, improving its turndown and lowering the warm compressor discharge pressure. As a result of these efforts, power consumption of the combined CHLs during normal operations has been reduced by nearly 10%, or a total of 650 kW. The observed performance of CHL1 with SC1R, as well as the cold compressor optimization method, leading to this improved energy consumption rate will be discussed in detail.

Mastracci, B [Thomas Jefferson National Accelerato

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 2 – Transient modeling and pump-down path selection

Low-pressure conditions required for operation of helium cryogenic systems below the normal boiling point (i.e. 4.2 K) are established through a transient process, commonly referred to as ‘pump-down’. This process is defined as the transition from pressures above atmospheric conditions to the saturation pressure which corresponds to a specified operational temperature. The FRIB 2 K system consists of five cryogenic centrifugal compressors which are operated in series. Historically, the pump-down process path has been established through empirical methods and system operator experience. Investigation into the pump-down process at FRIB aimed to develop a pump-down methodology which relies on theoretical model predictions rather than empirically developed process paths. Ensuring stable operation during the pump-down process involved application of a centrifugal compressor performance prediction model, which is described in Part 1 of this paper. Compressor performance maps can be directly used to evaluate the stability of a selected pump-down path and anticipate the overall reliability of the selected path. In conjunction with the compressor performance maps, a system pressure model was developed to estimate the transient pressure response during the pump-down process. Lastly, an explicit equation was developed to establish a mass flow rate profile for the pump-down process. Implementation of the presented methodology (including the developed models) allows for the system operator to determine a continuous pump-down path which maintains compressor stability while conforming to overall system capabilities. Altogether, the methodology presented has resulted in simplification of transient pump-down operations and increased the reliability, stability and efficiency of the pump-down process.

Compressor train control

Development of a near-isothermal transcritical CO 2 compression system with a liquid piston compressor

Compressors are critical components in vapor compression cycle systems, significantly contributing to energy consumption. As global demand for HVAC&R systems rises, enhancing compressor efficiency becomes increasingly vital. This paper introduces a novel liquid piston compressor integrated with a gas cooler for the transcritical CO 2 refrigeration cycle. The liquid piston enables CO 2 refrigerant compression within various types of heat exchangers, facilitating the transfer of compression heat to the heat transfer fluid. By releasing significant heat, this compressor allows for removing or downsizing the traditional gas cooler in the refrigeration system. This paper presents the experimental performance of the first near-isothermal compressor utilizing a liquid piston in a vapor compression cycle. The critical parameters affecting heat transfer are analyzed by using a 1-D simulation model to achieve a near-isothermal compression process. The results show that the developed prototype successfully reduced the compression temperature increase from 95 K to 10 K, achieving 90 % isothermal efficiency. Furthermore, the 1-D simulation results suggest the smaller internal diameter tubes benefit the isothermal efficiency the most.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY

Dynamic Modeling of Near Isothermal Compressor for Transcritical Carbon Dioxide Cycle

Compressors are the major energy consumption components in vapor compression systems, drawing much research effort in reducing carbon emissions. The isothermal compressor integrates the compressor chamber and gas cooler to achieve near isothermal compression, reaching up to 30% energy reduction compared to the traditional isentropic compression work. This paper presents a detailed isothermal compressor model combined with a generalized liquid piston model to account for the carbon dioxide (CO2) isothermal compression process. The model is established based on MATLAB environment. The model uses the real experimental data as boundary conditions and initial settings, which also considers the CO2 solubility in liquid piston (mineral oil) for designing, optimizing and customizing the compression chambers. The validation was carried out with experimental data using a prototype with 3.5 kW capacity. The results have demonstrated the accuracy of the dynamic model (6.2% relative error for chamber pressure and 0.5 K deviation for chamber temperature), which provide a guideline for designing and customizing the isothermal compression cycle.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ANALYSIS OF SUITABLE METHODOLOGIES FOR COMPRESSOR MASS FLOW RATE CORRECTION TO OTHER SUPERHEAT LEVELS AND REFRIGERANTS

This paper investigates the impact of suction conditions and refrigerant on scroll compressor mass flow rate by using calorimeter tests from AHRI-11 and AHRI-21 reports, published by AHRI's Low-GWP Alternative Refrigerants Evaluation program. Two Copeland scroll compressors (20 and 51 cm3) have been analyzed including different suction conditions (SH = 11K, SH = 22K, Ti = 18ºC) and several refrigerants (R134a, R32, R410A, R404A, etc.). Previous studies have explored response surfaces for energy consumption and mass flow rate variables. This study aims to expand the analysis by identifying the optimal approach to extrapolate mass flow rate from specific suction conditions to others SH or suction temperature levels and refrigerants. The current compressor characterization standard relies on the 1981 Dabiri correlation to correct compressor mass flow rate with suction conditions. Thus, this study aims to assess the adequacy of this correction and explore alternative correction methods for improved results.

Marchante Avellaneda, Javier

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control

A Review of the Research and Development of Brayton Cycle Technology in Nuclear Power Applications with a Focus on Compressor Technology

This study reviews the integration of Brayton Cycle (BC) systems in nuclear power generation, emphasizing their potential to enhance thermal efficiency and operational flexibility over traditional Rankine Cycle (RC) systems. Key working fluids, such as helium (He), supercritical carbon dioxide (sCO 2 ), nitrogen (N 2 ), and air, are evaluated for their performance, efficiency, and compatibility with nuclear systems. He is recognized for its high thermal conductivity and inertness at elevated temperatures, while sCO 2 demonstrates advantages in compactness and efficiency in midrange temperatures. This article also highlights the importance of compressor designs in optimizing BC performance and reviews, available compressor technologies. Axial and centrifugal compressor designs enable efficient gas compression while managing the thermal and mechanical stresses associated with high-pressure operations in nuclear systems. Combined with variable geometry components and advanced materials, these technologies address the challenges posed by varying load conditions. Despite the promising features of BC systems, several challenges persist, including high leakage rates and material degradation under extreme conditions, which necessitate robust sealing technologies and thorough testing. The insights gained from operational experiences at facilities, such as the Oberhausen II plant and the High-Temperature He Test Facility (HHV), underscore the complexities involved in designing high-temperature gas turbines for nuclear applications. This review concludes that as the nuclear industry evolves, BC systems hold significant promise for contributing to a sustainable energy future, particularly in the context of small modular reactors (SMRs) and microreactors. Further exploration of combined cycle configurations that combine BCs with RCs may enhance overall efficiency and flexibility in power generation.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Commissioning Results of the ESR2 Compressors at JLab

Abstract The future operation of the 4 kW 15 Kelvin MOLLER experiment at Jefferson lab necessitates an increase of cryogenic capacity at the End Station Refrigerator. The current plant is the former 1.5 kW (4.5 K) ESCAR plant that has been operating at Jefferson Lab since 1995. The existing 1.5 kW plant is not able to support the load for MOLLER and will be replaced with a refurbished plant comprised of the cold box and compressors of the 4 kW ASST-A plant from the Superconducting Super Collider in Texas. This paper reports the commissioning results of the warm compressor system. We compare the compressors’ current and past performance, specifically examining their Isothermal and Volumetric efficiency. The results indicate that the refurbished equipment’s efficiency is comparable to its original performance, proving that the reuse and refurbishment of old systems is a worthwhile endeavor.

Perry, C. [Thomas Jefferson National Accelerator F

MULTI-LEADER: MULTI-source LEarning-Accelerated Design of high-Efficiency multi-stage compRessor (Final Technical Report)

The objective of MULTI-LEADER is to cut design costs by 80% while generating more energy-efficient designs of multi-stage compressors by developing and implementing novel machine learning (ML) techniques, which enable faster and fewer design iterations, improved solver performance, and concurrent multi-disciplinary design. Current industrial practices for the design of multi-stage compressors involve simulation-based design optimization with successive levels of model fidelity, iteratively evaluated between distinct disciplines, one stage at a time to tackle the high dimensional design variations. This project addresses these key design challenges: (1) concurrent optimization of multiple stages under many non-linear constraints; (2) multitude of evaluation of high-fidelity and expensive solvers and their gradients during optimization convergence in high-dimensional design; (3) multi-disciplinary design to maximize aerodynamic performance while guaranteeing structural integrity and additive manufacturability; (4) utilization of multiple fidelity of solvers with disparate parameterization and modeling assumptions. MULTI-LEADER achieved more than 5x speed up in detailed design of more energy-efficient compressors via these machine learning (ML) innovations: (i) rapid design surrogates by multi-source learning from diverse fidelities across multiple disciplines, (ii) physics-constrained data-augmented modeling for improved empiricism, (iii) generative manifold embedding for high dimensional concurrent design without gradient information; (iv) budget-constrained fidelity-adaptive sampling towards fewer design iterations.

33 ADVANCED PROPULSION SYSTEMS

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump

Shape optimization and fluid control of near isothermal compressor for transcritical carbon dioxide cycle

The compressor holds great promise for enhanced energy efficiency over a wide range of vapor compression systems (VCS). However, the majority of them focused on liquid refrigerant injection or inter-stage cooling technologies to improve heat transfer. Increasing the heat transfer area provides another perspective to promote heat dissipation, which commonly involves shape optimization whilst bringing some limitations, mainly from the manufacturing side. To fill the research gap, this paper compares the performance of isothermal compressors under different compression chamber shapes and chamber connection configurations. Additionally, the fluid control of the liquid piston was combined with shape optimization to explore the potential for further heat transfer enhancement. The simulation results have demonstrated that the COP improvements can reach up to 9% compared with the baseline case by optimizing the chamber shape and properly controlling the liquid piston speed, which provides a guideline for designing and customizing the isothermal compression chamber.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Dynamic modeling of near isothermal compressor for Transcritical carbon dioxide cycle to support efficiency improvement

Compressors are the primary components of energy consumption in vapor compression systems, drawing considerable research effort to reduce carbon emissions and improve energy efficiency. This work presents an isothermal compressor that integrates the compression chamber with the gas cooler to achieve near-isothermal compression, resulting in up to 30% energy reduction compared to traditional isentropic compression, according to the experiment results. A detailed dynamic model for the isothermal compression cycle of carbon dioxide (CO 2 ) is first presented, coupled with a liquid-piston model for chamber design. The model is experimentally validated on a 3.5 kW prototype, yielding a 6.2% relative error in chamber pressure and a 0.5 K deviation in chamber temperature. The liquid piston exhibits reduced frictional heating and geometric adaptability relative to the mechanical piston. Leveraging these attributes, the study further evaluates approaches that enhance the heat transfer to achieve isothermal compression by increasing the effective heat transfer area during compression. As a result, simulations demonstrated up to a 5% improvement in the coefficient of performance over the baseline case through chamber design, providing guidelines for design of isothermal compression cycle.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI