Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Cold plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Ultra-low thermal resistance and pressure drop copper and copper-tungsten diamond-shaped pin fin cold plates for liquid cooling of electronics

Modern and future data centers face increasing cooling challenges due to increasing chip thermal design power and die size, along with the need to reduce energy consumption used for cooling. High performance cooling solutions that maintain a low chip junction temperature are needed to ensure electronics reliability. This work develops an ultra-low thermal resistance and low pressure drop 75 mm × 75 mm cold plate, intended for next-generation electronics cooling. The cold plate features an array of diamond-shaped pin fins and integrated copper tungsten heat spreader, selected for its low coefficient of thermal expansion which reduces thermomechanical deformation and allows for closer integration of the cold plate with silicon dies. Starting with 300 candidate designs, three-dimensional computational fluid dynamics simulations predict the thermal-hydraulic performance of cold plate subsections. The highest performing geometries are evaluated with high fidelity simulations. Four cold plates are manufactured for experiments: three with diamond-shaped pin fins and one with straights fins for comparison purposes. The cold plates are fabricated from copper-tungsten (CuW), copper (Cu), or aluminum-silicon-magnesium alloy (AlSi10Mg). The diamond-shaped pin fins achieve a roughly 15 % lower thermal resistance compared to the conventional straight fin microchannel. The highest performing design achieves a chip-to-coolant (including thermal interface material) thermal resistance of 9.0 K/kW in CuW and 6.9 K/kW in Cu under a 1 kW heat load with an inlet-to-outlet pressure drop of 9.0 kPa and water as the working fluid. This work demonstrates ultra-low thermal resistance and pressure drop cold plates for large die, high heat load applications, and shows that CuW is an attractive cold plate material for improved reliability in next generation data center cooling.

Coefficient of thermal expansion

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Thermal Optimization and Experimental Demonstration of a Silicon Carbide, Half-Bridge Power Module

This paper describes modeling and experimental work to design and demonstrate a silicon carbide (SiC), single-side-cooled power module. Two SiC metal-oxide-semiconductor field-effect transistors (MOSFET) were used for each switch position and packaged on a metalized ceramic substrate. Thermal modeling was first conducted to optimize the module packaging to minimize junction-to-fluid thermal resistance and device temperature variations. This procedure identified the optimal device placement and baseplate thickness to maximize thermal performance. A heat exchanger - incorporating impinging jets of water-ethylene glycol - was designed to cool the module's baseplate to minimize thermal resistance and pumping power. The heat exchanger used relatively low fluid velocities (<1.5 m/s) to minimize erosion-corrosion effects and relatively large fluid channel sizes (>=1 mm) to prevent clogging. The power module concept was fabricated, and experiments were conducted to measure its thermal performance. Direct current was used to power the module devices, and junction temperatures were measured via device temperature-sensitive parameters. The experimental results were found to be in good agreement with model predictions (within 2%) and yielded junction-to-fluid thermal resistance values as low as about 15 mm2 K/W at relatively low pumping power values. The results demonstrate the improved performance associated with jet impingement cooling and represent an improvement over existing channel-flow-type cold plates, which can enable improvements to power density and reliability.

36 MATERIALS SCIENCE

Experimental Measurements of Soot and Soot Precursors of Sustainable Aviation Fuels

Sustainable Aviation Fuels (SAFs) are promising for decarbonizing the challenging-to-electrify aerospace sector and reducing yearly greenhouse gas emissions by thousands of tons. Developing predictive detailed chemical kinetic models for SAF (and traditional) fuel mixtures necessitates a robust experimental database to elucidate the intricate pyrolysis and oxidation chemistry of SAF fuel blend components. Two critical components of SAF surrogate mixtures are iso-dodecane isomers and trans-decalin. This report characterizes the structure of three slightly sooting, laminar, non-premixed, nitrogen-diluted Planar Mixing Layer Flames (PMLFs) fueled by either pure ethylene, ethylene doped with 1500ppm of either 2,2,4,6,6-pentamethyl-heptane or trans-decalin. The flames have the same stoichiometric mixture fraction and total mole fraction of fuels in the fuel stream (X F,F = X C2H4,F + X Dopant,F = 0.26), resulting in approximately the same maximum temperature (T max ≈ 1800 K) to highlight the effect of doping on soot and its gaseous precursors. The PMLF is unconfined and established between adjacent planar jets of the fuel and oxidizer streams surrounded by annular shielding nitrogen. The flow is stabilized by exhausting the hot buoyant flame products through a slot in a downstream plate onto which the cold flow impinges. Importantly, any horizontal cross-section of the PMLF has a self-similar thermochemical structure of a reactive boundary layer that grows at increasing Height Above the Burner (HAB). Therefore, the horizontal cross-sections of a PMLF can be modeled as a One-Dimensional Counterflow Flame (1D-CF) with very low strain rates which are unachievable in traditional CFs and yield a structure that is several millimeters thick. In brief, the PMLF is ideal for performing spatially resolved measurements with minimal effects of the sampling-induced perturbations, to develop and validate detailed chemical kinetic models on time scales of a few tens of milliseconds that are relevant in aviation applications. The horizontal profiles of C0-C18 gaseous species at HAB = 50 mm and soot volume fraction at 25 and 50 mm are measured using capillary sampling followed by GC-MS analyses and Laser Induced Emission Spectroscopy (LIES), respectively. Additionally, the Elastic Laser Light Scattering (E-LLS) coefficient is measured at HAB = 50 mm and 25 mm to determine the strain rates of the 1D-CFs equivalent to the characterized PMLF horizontal cross sections and the profile of the E-LLS equivalent diameter of soot. The comparison of the results in the base PMLF fueled only by ethylene with those in either doped PMLF in which 1500 ppm of ethylene are replaced with 2,2,4,6,6-pentamethyl-heptane or trans-decalin, reveals that the doping increases the mole fraction of several Polycyclic Aromatic Hydrocarbons (PAHs) at both HABs by a factor of approximately 2.5, and the soot volume fraction at both HABs by factors of ~1.5 for 2,2,4,6,6-pentamethyl-heptane and ~1.25 for trans-decalin doping, respectively. Conversely, doping causes a near doubling of the soot equivalent diameter only at HAB = 50 mm, without significant effects at 25 mm. The experimental results partially validate the tested state-of-the-art detailed chemical kinetic model and also point toward the further improvement of its predictive capabilities.

10 SYNTHETIC FUELS

Onset of Fluidization in MP-PIC Simulations using MFIX-Exa

Fluidized bed reactors are used across a variety of industries, including for energy processes like pyrolysis that result in low-cost energy products. Design and scale-up of fluidized beds is de-risked by modeling and simulation, utilizing tools like NETL’s MFIX-Exa High-Performance Computing (HPC) code for reacting multiphase flow. This report summarizes an investigation into the breadth of problems to which MFIX-Exa may be applied, specifically with regard to low fluid velocities and the onset of fluidization. A simple fluidization study is conducted both experimentally and numerically for particles of interest, then reactor simulations are compared to cold flow experiments for uniform distributor plates. Approaches for modeling bubble caps are also presented.

discrete particle method

Initial Engineering Framework for Species Tracking in MSRs Involving Fuel Salt and Structures

This report implements a high-fidelity multiphysics modeling framework using the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program tools to track leaching and plating of materials between the fuel salt and structures in Molten Salt Reactors (MSRs). Specifically, this framework is demonstrated in modeling various processes within MSRs including hot and cold leg corrosion, redox potential driven corrosion, colloid precipitation and deposition, and noble metal plating and decay heat modeling. The model integrates neutronics, thermal-hydraulics, depletion, and thermochemistry to simulate the evolving chemical behavior of the fuel salt in interactions with structural materials. Initial findings suggest that hot-cold leg corrosion in MSR systems may become significant if the redox potential of the fuel salt is not sufficiently controlled. Additionally, the impact of noble metal decay heat deposition in large power reactors is explored. The resulting engineering framework for species tracking will be applied in the future toward specific validation work with ongoing experimental efforts focusing on both chloride and fluoride salt loop experiments with in-situ corrosion and redox control instrumentation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Rational Electrolyte Formulation for Sodium Metal Batteries Operating in Extremely Cold Environments

Sodium metal batteries have shown considerable potential when operated at ambient temperatures. However, their performance in cold environments is constrained by increased electrolyte resistance with decreasing temperature and dendritic sodium plating associated with unstable solid electrolyte interphase (SEI), which are primarily influenced by the electrolyte composition. In this study, we present an electrolyte formulation that remains thermally stable down to −150 °C, which not only facilitates low internal resistance but also contributes to the formation of a protective SEI under cryogenic conditions. When cycled at −40 °C at 1 mA cm −2 , the sodium metal electrode exhibits a low overpotential of only 16 mV over 750 h; even at an ultra-low temperature of −80 °C, the electrode demonstrates remarkable long-term stability with a low overpotential of 54 mV sustained over 1500 h at 0.5 mA cm −2 . Furthermore, full cell evaluations when paring with Na 3 V 2 (PO 4 ) 3 cathode reveal a high average Coulombic efficiency exceeding 99.1% and a capacity retention over 83% after 100 cycles at both −40 °C and −80 °C.

Electrolyte

High-Speed and High-Quality Field Welding Repair Based on Advanced Non-Destructive Evaluation and Numerical Modeling

Creep strength-enhanced ferritic (CSEF) steels such as Grade 91 (9Cr-1Mo-V) and Grade 92 (Fe-9Cr-2W-0.5Mo) steels are widely used in the fossil-fuel-fired and nuclear power plants. The weld integrity of these steels is crucial for power plants' safe and reliable operations. Due to harsh service conditions, the steel weld can become susceptible to environmental degradation. Field welding repair is used to restore the degraded weld’s performance where a controlled temper-bead welding technique is commonly used to temper the freshly formed martensite during welding. However, knowledge of weld repairability is limited and experimental trial and error optimization to achieve desired microstructure and joint properties is expensive and time-consuming. Many existing computational models, e.g., finite element models, are limited to solving heat conduction equation and ignoring convective heat transfer due to molten metal flow. These models can result in over-prediction of peak temperatures of weld pool and heat-affected zone (HAZ), which in turn can affect the accuracy of tempering prediction. Moreover, these finite element models require an input of the deposit profiles in advance and thus limits the usability of these models. Here, a molten pool-based, multi-pass multi-layer model has been developed based on computational fluid dynamics (CFD) approach with the Volume of Fluid (VOF) method. The model calculates the bead formation, thereby eliminating the need for pre-determined bead profiles required by finite element models. For computational efficiency, a coordinate system attached to the moving heat source is utilized. A subroutine is developed to convert the temperature profiles in the reference frame stationary to the heat source to that stationary to the workpiece. The converted thermal cycles are then imported into a microstructure model to compute the tempering kinetics and resultant hardness using a Johnson-Mehl-Avrami-Kolmogorov (JMAK), and modified Grange-Baughman parameter. The modeling approach is first developed and validated on single- and multi-pass deposition of stainless steel filler metal onto a SA-533 high strength steel substrate. The models are then applied to a multi-pass V-groove repair weld of Grade 91 steel plate as well as directed energy deposition of Grade 92 steel. Non-destructive characterization of microstructures was performed on Grade 91 and 92 steel welds. Two welding processes, cold metal transfer (CMT) and flux-cored arc welding (FCAW), were investigated for the Grade 91 steel weld samples. For the Grade 92 weld samples, three different heat inputs (low, medium, and high) of gas tungsten arc welding (GTAW) were utilized to replicate traditional field welding processes. The non-destructive evaluation (NDE) method used for this research was immersion ultrasonic testing (UT) using a micro-resolution ultrasonic imaging methodology specifically designed to operate in the through-transmission configuration operating at 20 MHz of frequency. The system used a focused ultrasonic beam spot size diameter between 250-300 μm, and a 6 μm laser vibrometer spot size for detection, to produce highly defined images with longitudinal and mode-converted shear waves. From the micro-resolution ultrasonic C-scan images, three microstructural regions, i.e., weld metal (WM), HAZ, and base metal (BM), were clearly identifiable. Various levels of ultrasonic amplitudes distributed over the three regions were correlated with electron beam backscattered diffraction (EBSD) images using grain size, grain boundaries, and dislocation densities. The results showed that areas with relatively higher ultrasonic amplitude levels were associated with smaller grains and higher dislocation densities, while areas with lower amplitude levels were associated with larger grains and lower dislocation densities. In addition, ultrasonic velocity data obtained across the three different weld microstructural regions of Grade 91 test samples were correlated with optical metallographic images and hardness measurements. The results showed distinctive decreases in ultrasonic velocity and hardness over the HAZ region, where weld failures often occur during service.

36 MATERIALS SCIENCE

Influence of rolling reduction and annealing on recrystallization and grain structure in Ta-2.5W alloys

The microstructural evolution of wrought Tantalum - 2.5 wt% Tungsten (Ta-2.5W) alloys during thermomechanical processing is critical for optimizing their mechanical reliability in demanding applications such as aerospace, chemical processing, and nuclear technology. Despite the widespread use of Ta-W alloys, a comprehensive understanding of how rolling reduction, annealing temperature, and elemental inhomogeneity interact to determine recrystallization behavior and grain refinement remains incomplete. Here, in this study, we systematically investigate the effects of cold rolling and subsequent annealing on the microstructure of Ta-2.5W, with particular attention to grain orientation, stored energy, and elemental banding. Our results demonstrate that higher rolling reduction rates lower the onset and completion temperatures for recrystallization, resulting in finer and more homogeneous grain structures. Electron backscatter diffraction (EBSD) analysis reveals that grains with a 〈111〉 parallel to the plate normal possess higher stored energy and nucleate recrystallization more readily than grains with a 〈001〉 parallel to the plate normal. Elemental mapping shows that tungsten inhomogeneity leads to localized bands of accelerated recrystallization and hardness variation. These findings provide new insights into the mechanisms of microstructure refinement in Ta-2.5W alloys, offering guidance for tailoring processing routes to achieve superior performance in demanding engineering environments.

Annealing

Seismic Performance of Conventional and Additively Manufactured U-Shaped Flexural Plates

U-shape flexural plates (UFPs) have gained significant attention in seismic structural design due to their ability to provide stable hysteresis behaviour and serve as effective energy-dissipating devices. Concurrently, Additive Manufacturing (AM) has advanced significantly, enabling the production of metallic components with mechanical properties comparable to those of conventionally manufactured cold-rolled materials. This study aims to explore the seismic response of single and double UFP fabricated through Laser Powder Based Fusion (LPBF) and conventional cold rolled 316L stainless steel (SS). The experimental results are evaluated based on force-displacement hysteresis behaviour, energy dissipation capacity, load-carrying capacity, and stiffness degradation. The findings confirm the efficacy of AM-fabricated UFPs for seismic energy dissipation. Additionally, the results suggest the potential for further improvement through the optimization of AM process parameters, such as laser scan speed, hatch spacing, and layer thickness, to enhance hysteretic performance and energy dissipation characteristics.

Risal, Kshitiz [Idaho State University]

Field-Emission Properties of Vertically Aligned Carbon Nanotube Cathodes of Varying Geometries

This work characterizes the bulk emission properties of carbon nanotube (CNT) forest cathodes fabricated with various geometries. Geometries explored include dense nanotube forests of varying height grown on 5×5 mm silicon (Si) substrates and discrete, patterned CNT pillars fabricated using UV photolithography. Dense forests heights ranged from 526 μ m to 1.41 mm, with packing fraction for dense forest calculated to be 4e10 nanotubes/cm2 based on an average nanotube separation distance of 100 nm for fixed growth dense forests. Patterned sample micro pillar heights ranged from 47 to 393 μ m with pillar widths on tested samples ranging from 250 to 270 μ m . Properties explored include emission current, turn-on field, and emission current performance over time. A parallel plate electron beam diode with a 100- μ m A-K gap and an automated test apparatus were developed to provide a configurable experiment that provides accurate and repeatable measurements for dc, dc sweep, and timed performance testing. Operating voltages for the voltage sweeps spanned from 0 to −350 V. Furthermore, testing has shown evidence of a hysteresis effect on the emission current tied to the applied field history as well as shifting of the turn-on field magnitude throughout the testing period, suggesting a conditioning effect during use. Three separate emission regions in the I–V curves during sweep testing have also been observed. In the geometric study, dense forests and patterned samples were sweep tested up to a peak applied voltage of −250 V, with the taller samples generally performing better. Currents produced in the geometric study from the dense forest emitters ranged from 36.8 to 572.34 μ A , with current densities ranging from 15 to 2.29 mA/cm2. Currents produced from the patterned micropillar emitters ranged from 39.4 to 317.51 μ A , with current densities ranging from 67 to 3 mA/cm2. DC time testing s...

36 MATERIALS SCIENCE