Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY

Ultra-low thermal resistance and pressure drop copper and copper-tungsten diamond-shaped pin fin cold plates for liquid cooling of electronics

Modern and future data centers face increasing cooling challenges due to increasing chip thermal design power and die size, along with the need to reduce energy consumption used for cooling. High performance cooling solutions that maintain a low chip junction temperature are needed to ensure electronics reliability. This work develops an ultra-low thermal resistance and low pressure drop 75 mm × 75 mm cold plate, intended for next-generation electronics cooling. The cold plate features an array of diamond-shaped pin fins and integrated copper tungsten heat spreader, selected for its low coefficient of thermal expansion which reduces thermomechanical deformation and allows for closer integration of the cold plate with silicon dies. Starting with 300 candidate designs, three-dimensional computational fluid dynamics simulations predict the thermal-hydraulic performance of cold plate subsections. The highest performing geometries are evaluated with high fidelity simulations. Four cold plates are manufactured for experiments: three with diamond-shaped pin fins and one with straights fins for comparison purposes. The cold plates are fabricated from copper-tungsten (CuW), copper (Cu), or aluminum-silicon-magnesium alloy (AlSi10Mg). The diamond-shaped pin fins achieve a roughly 15 % lower thermal resistance compared to the conventional straight fin microchannel. The highest performing design achieves a chip-to-coolant (including thermal interface material) thermal resistance of 9.0 K/kW in CuW and 6.9 K/kW in Cu under a 1 kW heat load with an inlet-to-outlet pressure drop of 9.0 kPa and water as the working fluid. This work demonstrates ultra-low thermal resistance and pressure drop cold plates for large die, high heat load applications, and shows that CuW is an attractive cold plate material for improved reliability in next generation data center cooling.

Coefficient of thermal expansion

Conceptual design of a replacement 2.1 K cold box for the Spallation Neutron Source Central Helium Liquefier

Abstract After more than 20 years of operation, the cold compressor technology in use at the Spallation Neutron Source (SNS) is obsolete, and replacement parts and service are no longer available. SNS has partnered with Jefferson Lab to design and construct a replacement sub-atmospheric cold box outfitted with modern cold compressor technology. The general design follows from Jefferson Lab’s experience on other recent sub-atmospheric cold box projects. Design decisions are backed by thorough engineering analysis to ensure technical requirements are met in a cost-effective manner. Conceptual design of the replacement cold box has been completed, and will be summarized in this paper. It features five cold compressors with an operating flow range of 80-140 g/s, and includes piping and valving to support cold compressor maintenance without interrupting flow circulation to the load. The approach to thermal shielding, insulation, and integration of the upgraded cold compressor hardware into the existing SNS control system will also be addressed.

Mastracci, B [Thomas Jefferson National Accelerato

Long-Term Photovoltaic System Performance in Cold, Snowy Climates

As countries around the world transition towards renewable energy, there is increasing interest in using photovoltaic (PV) technologies to help decarbonize northern and alpine communities due to their scalability and affordability. However, a barrier to large-scale adoption of PV in cold climates is long-term performance uncertainty under snowfall, freeze-thaw cycles, low temperatures, and high winds. In this work, we provide a comprehensive review of published silicon degradation rates in cold Koppen-Geiger climate classifications of Dfb (humid continental), Dfc (subarctic), and ET (tundra). We first analyze the system degradation rates of three subarctic ground-mounted photovoltaic sites in North America using the RdTools year-on-year method: an Al-BSF double-axis tracking site in Fairbanks, Alaska (65degrees N); a PERC and silicon heterojunction bifacial vertical and south-tilted site in Fairbanks, Alaska; and a PERC south-facing fixed-tilt site in Fort Simpson, Northwest Territories (62degrees N). Degradation rates of these newly analyzed sites vary between -0.4%/year and -1.5%/year. Combining these data with previously reported cold climate degradation rates, we show that the distribution of cold climate degradation peaks at -0.1%/year to -0.2%/year but has a large tail with rates above -0.5%/year. The average reported cold climate degradation rate is -0.45%/year, whereas the median value is -0.33%/year. These results suggest that despite frequent freeze-thaw cycles and potential exposure to high wind and snow loads, PV systems in cold climates tend to degrade slower than PV systems in warmer climates. The limited sample size of reported degradation rates in cold climates (27) motivates the need for further data acquisition and monitoring efforts as new technologies are deployed.

14 SOLAR ENERGY

Cold Trap Replacement Project Report

This report documents the replacement of the Mechanisms Engineering Test Loop (METL) cold trap. The work involved preparation of the facility to replace the cold trap, removal of the existing welded cold trap from the sodium purification circuit, installation of a new replacement cold trap, completion of associated welds and examinations, restoration of instrumentation and heaters, and controlled return of the cold trap circuit to service. The replacement represented a significant maintenance evolution because the cold trap is an integral welded component of the sodium system. As a result, the work required coordinated control of sodium chemistry, deliberate formation of freeze plugs, inert gas management, precision cutting and welding, and a staged reheating and refill sequence. The activity was executed using procedural controls intended to protect personnel, preserve system cleanliness, and maintain the integrity of the sodium boundary throughout the work. This report provides a narrative summary of the milestone, including the purpose of the work, the pre-job system condition, the major field activities performed, observations made during execution, and the resulting post-work condition of the METL cold trap circuit.

42 ENGINEERING

Microstructure refinement of hot deformed Dy-free NdFeB magnets through a novel cold sintering approach by pressure-assisted spark plasma sintering

Anisotropic fine-grained Dy-free NdFeB high-performance magnets were produced using a novel cold sintering approach by pressure-assisted spark plasma sintering (SPS). The NdFeB nanocrystalline ribbon powders were subjected to cold sintering below 450 °C using pressure-assisted SPS, followed by hot deformation at 710 °C and 810 °C via SPS. Results indicate that cold sintering below 450 °C effectively restricts grain growth in the NdFeB magnets, yielding sub-100 nm scale grains across both fine-grained regions and most coarse-grained regions. The refined grain structure achieved through cold sintering allows for a lower hot deformation temperature as compared with the magnet by conventional sintering, as finer grains allow easier deformation and grain sliding/rotation. This process produces a highly fine-grained and anisotropic microstructure to achieve high magnetic performance (i.e., high intrinsic coercivity, remanence, and maximum energy product) in the magnets. The cold sintering (at 350 °C) and lower hot deformation temperatures required (e.g., 710 °C) help control grain coarsening and limit grain size that is commensurate with the size of a single magnetic domain of the Nd 2 Fe 14 B magnetic matrix phase, resulting in high intrinsic coercivity (H ci =11.4 kOe). Furthermore, the reduced hot deformation temperature mitigates the formation of coarse grain bands, leading to improved magnetic properties, specifically an increased remanence (B r = 14.3 kGs) and a high maximum energy product ((BH) max = 48 MGOe). In conclusion, cold sintered hot deformed NdFeB magnet also shows good thermal stability with reversible temperature coefficient α(B r )= -0.097 %/K and α(H ci )= -0.616 %/K at elevated temperatures up to 400 K.

Cold Sintering

Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska

The purpose of this report is to determine the effects that extreme cold temperatures have on electric vehicles (EVs) and electric vehicle supply equipment (EVSE). The adoption of EVs in extreme cold weather presents challenges that require careful analysis of efficiency and charging infrastructure. This report, "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska," explores how EVs and EVSE perform in temperatures as low as -40 degrees C (-40 degrees F), focusing on real-world data from Teslas in Alaskan winter conditions. The findings indicate that EVs can successfully function in extreme cold, though efficiency is significantly affected. Vehicles stored in heated environments outperformed those stored outdoors, with efficiency dropping by up to 69% for outdoor storage. Despite these challenges, none of the vehicles experienced failures that prevented travel. Storing EVs indoors led to benefits such as faster preconditioning and improved efficiency, while charging in extreme cold, though slower, remained functional. Ultimately, the report concludes that with proper precautions and best practices, EVs are viable transportation solutions in cold climates. Investing in enclosed, heated storage is recommended to maximize efficiency and minimize battery strain. As advancements in battery chemistry and thermal management progress, EV adoption in extreme climates is expected to become even more feasible.

33 ADVANCED PROPULSION SYSTEMS

Feasibility of Nitrogen as a Carrier Gas for Inconel Cold Spray in Hydropower Application

Cold spray deposition of Inconel nickel alloys has emerged as a promising strategy for mitigating cavitation erosion in hydropower facilities. Most prior developments employ helium (He) as the carrier gas because it enables high particle velocities and the formation of dense coatings. However, He is nearly two orders of magnitude more expensive than nitrogen (N2), which limits its widespread adoption in the hydropower sector. Although He-based cold spray can be justified for high value repairs, the lower cost and broad availability of N2 make it an attractive alternative. This study assesses the feasibility of N2-based cold spray of Inconel 625 powders for hydropower applications. Cavitation erosion testing shows that He-based coating exhibits cavitation resistance of ~398% relative to the 304L stainless steel (SS304L) substrate. In contrast, N2-based coating shows substantially lower cavitation resistance, reaching only ~69% of the SS304L substrate, even when higher carrier gas temperature and pressure are applied. When the Inconel 625 powder size is reduced from 44 to 22 µm under N2-based cold spray conditions, cavitation resistance increases significantly to ~148% of the SS304L substrate. Additional improvement can be obtained by incorporating fine chromium carbide powders into the feedstock, resulting in cavitation resistance of ~172% of the SS304L substrate. Overall, with optimized feedstock design, N2-based cold spray offers a practical and cost-effective approach for producing cavitation resistant coatings on hydropower components, although He-based cold spray continues to deliver higher cavitation resistance.

Wang, Tianhao

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F

Cold compressor performance and energy consumption improvements at Jefferson Lab’s Central Helium Liquefiers

Abstract Jefferson Lab operates two central helium liquefiers (CHLs) which both utilize full cold compression from the saturation pressure at operating temperature (approximately 2.1 K) to just over atmospheric pressure. The original plant, CHL1, was recently outfitted with a replacement subatmospheric cold box (SC1R) containing state-of-the-art cold compressor technology, while the newer plant, CHL2, uses an older cold compressor system. In both cases, the heat of compression is absorbed at low temperature at the expense of electrical power consumed by the warm compressors. Due to the superior efficiency and turndown capabilities of SC1R, a new operating mode has been identified for CHL1 in which the required number of operating warm compressors is reduced by one. A cost-based method for optimizing cold compressor stability and efficiency has been developed and applied to CHL2, improving its turndown and lowering the warm compressor discharge pressure. As a result of these efforts, power consumption of the combined CHLs during normal operations has been reduced by nearly 10%, or a total of 650 kW. The observed performance of CHL1 with SC1R, as well as the cold compressor optimization method, leading to this improved energy consumption rate will be discussed in detail.

Mastracci, B [Thomas Jefferson National Accelerato

Geometrical effects on the measured neutron residual stress in additively manufactured cold spray AA6061

Aluminum cold spray additive builds were made with varying wall widths and geometries to explore the effects of build geometry on residual stress development in the additively sprayed material. Deposition rates of over 750 g/hr were achieved without any cracking or delamination of the additively manufactured components. Neutron residual stress measurements revealed a maximum tensile residual stress of 41 MPa at the interface of the substrate and a maximum compressive residual stress of −35 MPa in the cold sprayed material. While there was not found to be significant residual stress changes between the cold sprayed walls, the cold sprayed cylinder had varying residual stress throughout the diameter with the outer diameter having a higher tensile residual stress than the interior. The low residual stress and minimal geometrical dependency demonstrate further part size is possible without concerns for component failure in AA6061. The application of common coating residual stress models to full scale additive builds is evaluated and discussed. The lack of residual stress evolution was studied by in-situ coating property measurement that revealed that the deposition stress of the AA6061 sprays reduced with increased layer thickness. In conclusion, this study provides insight into the evolution of residual stress in cold spray additive components and how both the mechanics and material responses differ from coatings.

Additive manufacturing

A comparative review on cold sprayed cermet coatings and their applications in high temperature corrosion, oxidation and wear resistance

This review article explores the properties and bonding mechanisms specific to cold sprayed cermet coatings, highlighting its contrast with that of pure metals, and pure ceramics. The general cost structure of cold spraying is compared with other thermal spray techniques and the advantages are highlighted. Several cold sprayed cermet coatings with good corrosion, oxidation and wear resistance behavior in elevated temperatures show convincing potential for applications in power generation industries. The important factors that are attributed to producing highly functional cold sprayed cermet coatings are discussed. A strategic approach involving material, equipment, and application specific optimization of the cold spray process is currently relevant and of utmost importance to meet the coating requirements in several industrial applications.

36 MATERIALS SCIENCE

Comparative Study of Zinc Cold-Spray Coating and Pre-treatments for Magnesium Alloys

Magnesium (Mg) alloys are appealing for automotive lightweighting owing to their high specific strength. However, their susceptibility to corrosion in harsh environments remains a major challenge. Conventional industrial pre-treatment coatings, including zinc phosphate, chromate conversion, and non-chromate conversion, often exhibit discontinuities and microcracks, leading to localized corrosion near fasteners and parting lines. Here, this study investigates cold-sprayed zinc (Zn) coatings as a novel pre-treatment alternative for high-pressure die cast (HPDC) AZ91 Mg alloys, demonstrating significant improvements in wear and corrosion performance. Cold spray produces uniform and robust coatings, reducing wear rate by over 50% and reducing corrosion rate by over 99.3%, as measured by evolved hydrogen release, compared to traditional pre-treatments. Multimodal corrosion testing reveals that Zn cold-spray coatings form a protective layer during exposure, minimizing general and filiform corrosion, and exhibiting corrosion potential (E corr ) that is nobler by ~ 400 mV than the surfaces of both pre-treated and uncoated AZ91. Scalability of cold spray for selective application around multimaterial joints further strengthens their industrial viability. This work establishes Zn cold-spray coatings as highly effective pre-treatment solutions for the advancement of corrosion resistant Mg alloy components in automotive applications.

multimodal corrosion

A Novel Surface Restoration Method for Hydropower Steel Components: Plasma Gouging and Inconel Cold Spray Coating for Material Repair

A novel surface restoration approach combining plasma gouging with subsequent cold spray deposition is demonstrated in this study. Plasma gouging effectively removes the damaged steel surface, leaving grooves and forming a plasma gouging affected zone up to ~300?µm thick. Within this zone, a hardened martensitic layer with a peak hardness of ~370?HV—almost twice that of the base substrate (~200?HV)—is produced. Following plasma gouging, cold spray deposition is applied to rebuild the surface. Experimental results reveal that cold spray coatings deposited at low energy suffer from delamination, whereas high energy cold spray deposits yield a well-bonded coating. Microstructural analysis further shows that the martensitic layer formed by plasma gouging undergoes dynamic recrystallization during cold spray, reducing the hardness to 317?HV. These findings demonstrate the feasibility of this hybrid method for effective surface restoration of damaged steel components.

Wang, Tianhao

Deformation band corrosion as a result of applied stress and cold-work in 304 stainless steel in simulated pressurized water reactor primary water conditions

Stainless steels like 304SS are commonly used in pressurized water reactor primary water environments due to their excellent resistance to stress corrosion cracking (SCC). However, SCC susceptibility has been observed in cold-worked 304SS. Cold-rolling introduces a high density of defects, such as deformation bands or dislocations, into the microstructure; applied stress, even if macroscopically below the yield stress, can result in regions with high localized stresses. Cold-worked and non-cold-worked samples were exposed to 360 °C simulated PWR primary water for 1500 h with and without active loading. Corrosion susceptibility of dislocations and deformation bands induced by cold-rolling and/or applied stress was studied using high-resolution (analytical) transmission electron microscopy. Deformation bands were generated in all specimens examined in the study. Penetrative oxidation was observed in some deformation bands in each specimen. The depth of penetrative deformation band oxidation frequently exceeded the depth of grain boundary oxidation in all specimens. However, deformation band oxides generally were narrowly confined to the deformation band plane. Highly Ni-rich regions were observed beyond all oxidation fronts. Surface oxides were thicker in the specimens exposed under active loading. In conclusion, the implications of these findings at surfaces for deformation bands intersecting stress corrosion crack paths are discussed.

EFTEM

Design and validation of a cold load for characterization of cosmic microwave background stage 4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by cosmic microwave background stage 4 (CMB-S4), the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three innovative design features: (1) the ability to operate from the 1-K stage of a dilution refrigerator (DR), (2) a He3 gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150-GHz detector array previously deployed by the Spider experiment. Thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1-K stage. In addition, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION