Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coherent spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multiplex coherent raman spectroscopy detector and method

A multiplex coherent Raman spectrometer (10) and spectroscopy method rapidly detects and identifies individual components of a chemical mixture separated by a separation technique, such as gas chromatography. The spectrometer (10) and method accurately identify a variety of compounds because they produce the entire gas phase vibrational Raman spectrum of the unknown gas. This is accomplished by tilting a Raman cell (20) to produce a high-intensity, backward-stimulated, coherent Raman beam of 683 nm, which drives a degenerate optical parametric oscillator (28) to produce a broadband beam of 1100-1700 nm covering a range of more than 3000 wavenumber. This broadband beam is combined with a narrowband beam of 532 nm having a bandwidth of 0.003 wavenumbers and focused into a heated windowless cell (38) that receives gases separated by a gas chromatograph (40). The Raman radiation scattered from these gases is filtered and sent to a monochromator (50) with multichannel detection.

Chen, Peter↗

Proposal for the measuring molecular velocity vector with single-pulse coherent Raman spectroscopy

Methods for simultaneous measurements of more than one flow velocity component using coherent Raman spectroscopy are proposed. It is demonstrated that using a kilowatt broad-band probe pulse (3-30 GHz) along with a megawatt narrow-band pump pulse (approximately 100 MHz), coherent Raman signal resulting from a single laser pulse is sufficient to produce a high-resolution Raman spectrum for a velocity measurement.

She, C. Y.↗

Coherent Raman spectroscopy for supersonic flow measurments

In collaboration with NASA/Langley Research Center, a truly nonintrusive and nonseeding method for measuring supersonic molecular flow parameters was proposed and developed at Colorado State University. The feasibility of this Raman Doppler Velocimetry (RDV), currently operated in a scanning mode, was demonstrated not only in a laboratory environment at Colorado State University, but also in a major wind tunnel at NASA/Langley Research Center. The research progress of the RDV development is summarized. In addition, methods of coherent Rayleigh-Brillouin spectroscopy and single-pulse coherent Raman spectroscopy are investigated, respectively, for measurements of high-pressure and turbulent flows.

She, C. Y.↗

Coherent light scattering spectroscopy for supersonic flow measurements

A unified discussion on coherent light scattering spectroscopy and its spectral dependence on molecular gas velocity, temperature and density is presented. The feasibility of using coherent Raman spectroscopy techniques for nonintrusive measurements of supersonic flow parameters is demonstrated and recent laboratory as well as wind tunnel experiments are reviewed. In addition, the advantages of using coherent Rayleigh-Brillouin spectroscopy for measuring high pressure flows are discussed.

She, C. Y.↗

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for practical combustion diagnostics

Coherent anti-Stokes Raman spectroscopy (CARS) is a coherent wave-mixing process in which the signal emerges as a laser-like beam in a precise direction. The spectroscopic technique is appropriate to spatially and temporally resolved measurements of temperature and major species concentrations in combustion. It has been generated from all of the dominant constituents in air-fed, hydrogen, and hydrocarbon fueled combustion, and found applicable to practical combustion systems. High pressure effects on CARS spectra have also been examined.

Eckbreth, A. C.↗

Diagnostics of silane and germane radio frequency plasmas by coherent anti-Stokes Raman spectroscopy

In situ plasma diagnostics using coherent anti-Stokes Raman spectroscopy have shown different dissociation characteristics for GeH4 and SiH4 in radio frequency (rf) plasma-enhanced chemical vapor deposition of amorphous silicon germanium alloy (a-SiGe:H) thin films. The GeH4 dissociation rate in rf plasmas is a factor of about 3 larger than that of SiH4. Plasma diagnostics have revealed that the hydrogen dilution of the SiH4 and GeH4 mixed plasma plays a critical role in suppressing the gas phase polymerization and enhancing the GeH4 dissociation.

Perry, Joseph W.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for combustion diagnostics

Investigations of coherent anti-Stokes Raman spectroscopy (CARS) in a variety of flames are presented. Thermometry has received the primary emphasis in these studies, but species spectral and sensitivity studies will also be described. CARS is generated by mixing a 10 pps, frequency-doubled neodymium 'pump' laser with a spectrally broadband, laser-pumped, Stokes-shifted dye laser. This approach obviates the requirement to frequency scan the dye laser and generates the entire CARS spectrum with each pulse permitting, in principle, instantaneous measurements of medium properties. CARS spectra of N2, CO, O2, H2O, CO2 and CH4 in flames will be presented. In general these spectra exhibit very good agreement with computer synthesized spectra and permit measurements of temperature and species concentration. To illustrate the applicability of CARS to practical combustion diagnostics, CARS signatures from N2 have been employed to map the temperature field throughout a small, luminous, highly sooting propane diffusion flame

Eckbreth, A. C.↗

Width-Increased Dual-Pump Enhanced Coherent Anti-Stokes Raman Spectroscopy (WIDECARS)

WIDECARS is a dual-pump coherent anti-Stokes Raman Spectroscopy technique that is capable of simultaneously measuring temperature and species mole fractions of N2, O2, H2, C2H4, CO, and CO2. WIDECARS is designed for measurements of all the major species (except water) in supersonic combustion flows fueled with hydrogen and hydrogen/ethylene mixtures. The two lowest rotational energy levels of hydrogen detectable by WIDECARS are H2 S(3) and H2 S(4). The detection of these lines gives the system the capability to measure temperature and species concentrations in regions of the flow containing pure hydrogen fuel at room temperature.

Tedder, Sarah A.↗

Width-Increased Dual-Pump Enhanced Coherent Anti-Stokes Raman Spectroscopy (WIDECARS)

WIDECARS is a dual-pump coherent anti-Stokes Raman Spectroscopy technique that is capable of simultaneously measuring temperature and species mole fractions of N2, O2, H2, C2H4, CO, and CO2. WIDECARS is designed for measurements of all the major species (except water) in supersonic combustion flows fueled with hydrogen and hydrogen/ethylene mixtures. The two lowest rotational energy levels of hydrogen detectable by WIDECARS are H2 S(3) and H2 S(4). The detection of these lines gives the system the capability to measure temperature and species concentrations in regions of the flow containing pure hydrogen fuel at room temperature.

Tedder, Sarah A.↗

A survey of simulation and diagnostic techniques for hypersonic nonequilibrium flows

The possible means of simulating nonequilibrium reacting flows in hypersonic environments, and the required diagnostic techniques, are surveyed in two categories: bulk flow behavior and determination of chemical rate parameters. Flow visualization of shock shapes for validation of computational-fluid dynamic calculations is proposed. The facilities and the operating conditions necessary to produce the required nonequilibrium conditions, the suitable optical techniques, and their sensitivity requirements, are surveyed. Shock-tubes, shock-tunnels, and ballistic ranges in a wide range of sizes and strengths are found to be useful for this purpose, but severe sensitivity requirements are indicated for the optical instruments, which can be met only by using highly-collimated laser sources. Likewise, for the determination of chemical parameters, this paper summarizes the quantities that need to be determined, required facilities and their operating conditions, and the suitable diagnostic techniques and their performance requirements. Shock tubes of various strengths are found to be useful for this purpose. Vacuum ultraviolet absorption and fluorescence spectroscopy and coherent anti-Stokes Raman spectroscopy are found to be the techniques best suited for the measurements of the chemical data.

Sharma, Surendra P.↗

Laser Diagnostics for combustion temperature and species measurements

Laser optical diagnostic techniques for the measurement of combustion gaseous-phase temperatures and, or species concentrations are discussed. The techniques fall into two classes: incoherent (Rayleigh scattering, spontaneous Raman scattering, laser induced fluorescence spectroscopy) and coherent (coherent anti-Stokes Raman spectroscopy). The advantages, disadvantages and applicability of each method are outlined.

Eckbreth, Alan C.↗

Coherent anti-Stokes Raman spectroscopy temperature measurements in a hydrogen-fueled supersonic combustor

Coherent anti-Stokes Raman spectroscopy (CARS) thermometry has been used to obtain static temperature cross sections in a three-dimensional supersonic combustor flowfield. Data were obtained in three spanwise planes downstream of a single normal fuel injector which was located downstream of a rearward-facing step. The freestream flow was nominally Mach 2 and was combustion heated to a total temperature of 1440 K (yielding a static temperature of about 800 K in the freestream) to simulate the inflow to a combustor operating at a flight Mach number of about 5.4. Since a broadband probe laser was used an instantaneous temperature sample was obtained with each laser shot at a repetition rate of 10 Hz. Thus root-mean-square (rms) temperatures and temperature probability density functions (pdf's) were obtained in addition to mean temperatures.

Smith, Michael W.↗

High-resolution continuous-wave coherent anti-Stokes Raman spectroscopy in a supersonic jet

High-resolution CW coherent anti-Stokes Raman spectra of the nu1 Q branch of methane in an underexpanded supersonic jet were obtained at temperatures as low as 31.5 K and pressures as low as 2 torr. The experimental spectra were well fitted by the calculated theoretical spectra, including transit-time broadening. A temperature of 31.5 K produced the best fit to the data, and the transit-time broadening was comparable to the residual Doppler broadening of about 100 MHz. The supersonic jet provides a convenient method of obtaining molecular cooling at relatively high density, and the ease of construction and the wide range of temperatures and densities available make it a useful tool for high resolution molecular spectroscopy.

Gustafson, E. K.↗

Coherent Anti-Stokes Raman Spectroscopy (CARS) Measurements in Supersonic Combustors at NASA Langley Research Center

This paper describes the recent use of coherent anti-Stokes Raman spectroscopy (CARS) to study supersonic combustion at NASA Langley Research Center. CARS is a nonlinear optical measurement technique used to measure temperature and species mole fractions remotely in harsh environments. A CARS system has been applied to two different combustor geometries at NASA Langley. Both experiments used the same vitiated wind-tunnel facility to create an air flow that simulates flight at Mach numbers of 6 and 7 for the combustor inlet and both experiments used hydrogen fuel. In the first experiment, the hydrogen was injected supersonically at a 30-degree angle with respect to the incoming flow. In the second experiment, the hydrogen was injected sonically at normal incidence. While these injection schemes produced significantly different flow features, the CARS method provided mean temperature, N2, O2 and H2 maps at multiple downstream locations for both. The primary aim of these measurements was to provide detailed flowfield information for computational fluid dynamics (CFD) code validation.

Danehy, Paul M.↗

Coherent anti-Stokes Raman spectroscopy - Spectra of water vapor in flames

The results of experimental measurements of the coherent anti-Stokes Raman spectra of water vapor in flames are reported. A pulsed, frequency-doubled neodymium laser was used to supply the pump beam and to pump a dye laser to provide a broadband Stokes beam at 6600 A. Spectra were obtained in the postflame region of a premixed methane-air flame in the Raman frequency shift region of the symmetric stretch mode (3651.7 kaysers) at an approximate temperature of 1675 K. A theoretical calculation of the coherent anti-Stokes Raman spectrum of water vapor at this temperature was made, taking into account only isotropic Q-branch transitions, and using the energy level data of Floud et al. (1976). The theoretical prediction is shown essentially to reproduce all qualitative features of the experimental spectrum, and to exhibit a strong temperature dependence.

Hall, R. J.↗