Comparison of Cryogenic Flow Boiling in Liquid Nitrogen and Liquid Hydrogen Chilldown Experiments

This paper presents a comparison between experimental results from recent liquid hydrogen (LH 2 ) transfer line chilldown experiments at high Reynolds (Re) numbers versus liquid nitrogen (LN 2 ) experiments conducted at low Re numbers. Parasitic heat leak, inner wall temperatures, inner wall heat fluxes, and heat transfer coefficients are computed to compare between the two systems. Analysis of temperature traces and flow visualization indicates that the chilldown process evolves much more rapidly at higher Re numbers due to a quick transition from vapor flow to annular liquid flow and near immediate liquid contact along the pipe walls. The lower kinematic viscosity and surface tension of LH 2 , along with reduced parasitic heat leak and higher Re numbers relative to the LN 2 experiments, causes chilldown to proceed almost immediately into the nucleate boiling regime, in comparison to low Re flows where >75% of the chilldown is spent in vapor film boiling.

Cryogenic Heat Transfer Coefficient

Numerical Modeling of the Transient Chilldown Process of a Cryogenic Propellant Transfer Line

Before cryogenic fuel depots can be fully realized, efficient methods with which to chill down the spacecraft transfer line and receiver tank are required. This paper presents numerical modeling of the chilldown of a liquid hydrogen tank-to-tank propellant transfer line using the Generalized Fluid System Simulation Program (GFSSP). To compare with data from recently concluded turbulent LH2 chill down experiments, seven different cases were run across a range of inlet liquid temperatures and mass flow rates. Both trickle and pulse chill down methods were simulated. The GFSSP model qualitatively matches external skin mounted temperature readings, but large differences are shown between measured and predicted internal stream temperatures. Discrepancies are attributed to the simplified model correlation used to compute two-phase flow boiling heat transfer. Flow visualization from testing shows that the initial bottoming out of skin mounted sensors corresponds to annular flow, but that considerable time is required for the stream sensor to achieve steady state as the system moves through annular, churn, and bubbly flow. The GFSSP model does adequately well in tracking trends in the data but further work is needed to refine the two-phase flow modeling to better match observed test data.

Temperature Sensors

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen

Heat Transfer Enhancement in Cryogenic Quenching Process

This paper reports a heat transfer advancement in the cryogenic quenching process. An experiment was performed to evaluate the enhancement of quenching heat transfer by the use of metal tubes with low thermal conductivity coating layers. Four coating thicknesses with various coolant mass flow rates of liquid nitrogen were investigated. The results indicated that the tube inner surface coating greatly enhanced the quenching efficiency. The quenching efficiency was found to increase with increasing number of coating layers, and the efficiency also increased with decreasing mass flow rates. In general, the efficiencies cover a range between 40.6% and 80%. Comparing to the bare surface case, the percentage increase in the quenching efficiency was the minimum at 4.2% for a single coated layer at the highest flow rate and the maximum of 109.1% for four coated layers at the lowest flow rate. The coated tubes could save up to 53% in the amount of cryogen consumption.

two-phase flow

Numerical Predictions of the Flow and Heat Transfer Characteristics in the Film Boiling Regime During Tube Quenching

Cryogenic fluid management plays a major role in refueling of spacecrafts while in space for NASA’s future human space exploration missions. Due to the low boiling points of cryogens, storage, transport and handling of these fluids becomes difficult and may result in inefficient operation of the space propulsion systems. For refueling applications in space, the cryogenic fluids have to be transported across different locations and hence, the transfer of cryogenic fluids through pipes become critical. The cryogenic chill-down process is characterized by different regimes of flow boiling, viz., film boiling, transition boiling and nucleate boiling. The prediction of these regimes in a single CFD framework available in the literature is challenging and the present work attempts to address this challenge by initially modeling the film boiling regime accurately and to incorporate an user-defined function for transition and nucleate boiling at a later stage. Hence, the aim of the present work is to numerically model and validate the film boiling regime of the chilldown curve for liquid nitrogen experiments available in the literature. The validations are carried out at different inlet mass fluxes to have a robust simulation methodology. A dispersed mixture model is used to predict the vapor-liquid interface dynamics with the phase change phenomena modeled using the Lee model.

line chilldown

Cryogenic Spray Quenching of A Simulated Propellant Storage Tank Wall With Heat Transfer Enhancement By A Thin-Film Coating and Flow Pulsing in Microgravity

Human space exploration to the Moon, Mars, and possibly asteroids is NASA’s biggest challenge for the new millennium. One of the critical elements to this mission is the effective, sufficient, and reliable supply of cryogenic propellant fluids. Future lower-earth-orbiting (LEO) propellant fuel depots and human-carrying orbital transfer spacecraft flying to the moon and Mars will have to utilize the high thrust and high efficiency of liquid cryogenic chemical propulsion or nuclear thermal propulsion. Efficient in-space tank-to-tank propellant transfer (propellant fuel depot to orbital transfer spacecraft) of cryogenic propellants is an enabling technology for the planned Crewed Mars Surface Mission. The transfer of cryogenic propellants in space, however, has yet to be accomplished, solely due to the unavailability of cryogenic quenching heat transfer data during chilldown (quenching) and filling of the propellant receiver tank in reduced gravity and microgravity as liquid propellant cannot be stored in a required liquid state until the tank is quenched down to the liquid temperature. Therefore, highly energy efficient thermal-fluid management breakthrough concepts to conserve and minimize the cryogen consumption during propellant transfer have become the focus of research and engineering development, especially for the deep-space mission to Mars. In this paper, we introduce such concepts and demonstrate their feasibility for cryogenic storage tank chilldown in parabolic flights under a simulated space microgravity condition. In order to maximize the storage tank chilldown efficiency for the least amount of cryogen consumption, the technology adopted included cryogenic spray cooling, Teflon thin-film coating of the simulated tank surface, and spray flow pulsing. The completed flight experiments successfully demonstrated that spray cooling is the most efficient cooling method for the tank chilldown in microgravity. In microgravity, Teflon coating alone can improve the efficiency up to 72% and the efficiency can be improved up to 59% by flow pulsing alone. However, Teflon coating together with flow pulsing was found to substantially enhance the chilldown efficiency in microgravity for up to 113%.

spray

Test Data Analysis of the Thermodynamic Vent System-Augmented Top Spray Injector Liquid Nitrogen Transfer Experiments

Traditionally, a cryogenic tank must be pre-chilled to some “target” temperature before the main vent valve can be closed to attempt a non-vented fill (NVF) of cryogenic liquid propellant. This methodology is particularly attractive for performing in-space transfer of cryogens due to the unknown location of the liquid/vapor interface in microgravity and the high likelihood of venting liquid if the vent valve is opened during transfer. This paper presents in-depth test data analysis of a Thermodynamic Vent System (TVS) augmented injector used for cryogenic tank chilldown and fill experiments of a thin-walled Titanium tank. Eight tests were conducted using liquid nitrogen across a range of inlet conditions and boundary conditions, and three different chilldown/fill methods. For four of the tests, the injector sprays liquid into the tank as normal, but also uses a TVS heat exchanger to cool the metallic injector itself as well as the main incoming liquid stream. Results show that using the TVS augmented injector simplifies transfer operation via enhanced condensation at the injector surface at the cost of sacrificing only a small amount of propellant.

Thermodynamic Vent System

CFD Modeling of Bi-Directional PMD inside Cryogenic Propellant Tanks Onboard Parabolic Flights

Future cryogenic propulsion systems will require efficient methods with which to transfer cryogenic propellants from a depot storage tank to a customer receiver tank to minimize cost and maximize reusability. The Reduced Gravity Cryogenic Transfer project is currently developing advanced cryogenic fluid management technology and developing and validating new numerical models for three phases of transfer: line chilldown, tank chilldown, and tank fill. Additionally, multiple liquid nitrogen (LN 2 ) parabolic flight transfer rigs are being designed by universities and NASA to investigate the gravitational sensitivities that exist in these three technologies. In order to maximize the collection of low-g data during flights, it is required to extract as much (LN 2 as possible from the supply tank, despite variable gravity levels. The purpose of this paper is to present computational fluid dynamics (CFD) volume of fluid simulations of (LN 2 behavior in the supply tank onboard parabolic flights to validate the optimal design of a bi-directional propellant management device (PMD) using the commercial software FLOW-3D. A parametric study is conducted on the effects of gravity level, fill level, pore size, open area, thickness, and type of baffle on PMD performance. Based on results, the PMD as designed exceeds the targeted expulsion efficiency.

Jason Hartwig