Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Chena”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Electric Vehicle Supply Equipment (EVSE) Site Assessment Report for the U.S. Army Corps of Engineers Chena Site Near Fairbanks, Alaska

This report presents an analysis of the requirements for charging station installation and electric vehicle operation at the US Army Corps of Engineers - Chena Site, located in a cold weather climate in the Fairbanks North Star Borough, AK. The report includes findings from a site visit, and a detailed electric vehicle (EV) charging site plan with cost estimates. Cost for three 50-ampere pedestal chargers located on the edge of the existing parking lot is estimated at $\$$53,100, and the cost of three 80-ampere chargers is estimated at $\$$89,400. The authors did not assess the cost of a heated garage. The USACE Chena site reaches extreme cold temperatures of -40 Degrees Celsius (-40 Degrees Fahrenheit) and below in a typical winter, often for days on end. Considerations of operating EVs as well as electrical vehicle supply equipment (EVSE) at this site can be applicable to other cold or extremely cold locations. Interviews with EV users in cold climates and a literature review indicated that EVs operate well but have significantly decreased range compared to 21 Degrees Celsius (70 Degrees Fahrenheit) operations. Some strategies such as prewarming the vehicle while it is plugged in and using heated seats and steering wheel instead of cabin heat, can improve cold weather performance. Storing the EV in a garage would mean the battery and cabin are automatically preheated, the battery would not age as rapidly as when the vehicle is stored outside, and problems with charging the vehicle are less likely. Lowest temperate-rated Electric Vehicle Supply Equipment (EVSE), as electric vehicle chargers are known as, are rated to -40 Degrees Celsius (-40 Degrees Fahrenheit), and sometimes malfunction. No EVSE is rated to the temperatures that USACE Chena site experienced for more than a week in winter 2023-4, of -50 Degrees Celsius (-45 Degrees Fahrenheit) and which are typical for the area. If reliability is a must, entities may want to consider a heated garage to minimize potential problems with charging equipment. There is a companion technical report to this titled "Electric Vehicle and Charging Infrastructure Assessment in Cold-Weather Climates: A Case Study of Fairbanks, Alaska" that examines the data on EV and EVSE cold-weather functionality in more detail. (Esparza, Truffer Moudra, and Hodge 2024).

33 ADVANCED PROPULSION SYSTEMS↗

GeoRePORT Case Studies - Coso, WSMR, Dixie Valley, and Chena Hot Springs

The Geothermal Resource Portfolio Optimization and Reporting Technique (GeoRePORT) was developed with funding from the U.S. Department of Energy Geothermal Technologies Office to assist in identifying and pursuing long-term investment strategies through the development of a resource reporting protocol. GeoRePORT provides scientists and nonscientists a comprehensive and quantitative means of reporting: (1) features intrinsic to geothermal sites (project grade) and (2) maturity of the development (project readiness). Because geothermal feasibility is not determined by any single factor (e.g., temperature, permeability, permitting), a site?s project grade and readiness are evaluated on 12 attributes pertaining to geological, technical, or socio-economic feasibility. In this paper, we present case studies showing how GeoRePORT can be used to compare geological, technical, and socio-economic attributes between geothermal systems. The consistent and objective assessment protocols used in GeoRePORT allow for comparison of project attributes across unique locations and geological settings. GeoRePORT case studies presented here outline the geological, socio-economic, and technical features of four individual geothermal sites: Coso, Chena, Dixie Valley, and White Sands Missile Range. The case studies illustrate the usefulness of GeoRePORT in evaluating project risk and return, identifying gaps in reported data, evaluating R&D impact, and gathering insights on successes and failures as applicable to future projects.

15 GEOTHERMAL ENERGY↗

Analyzing historical snow trends in interior Alaska

Study region The Chena River watershed in Interior Alaska, USA Study focus This study examines 40 years (water years 1982–2021) of snowpack characteristics to consider its hydrological implications in the 5350 km² Chena River basin. Using observations and a fine-scale physics model, we analyzed trends of snow water equivalent (SWE), snow onset and disappearance, and snow cover duration (SCD). New hydrological insights for the region Results indicate a decline in SWE across the modeled domain, averaging a decrease of 3 mm per decade, with larger decreases (up to 10 mm per decade) at lower elevations. While domain-averaged SWE trends were not statistically significant, observed SCD showed statistically significant decreases: −5.2, −5.0, and −4.4 days per decade at Teuchet Creek, Fairbanks F.O., and Little Chena Ridge, respectively. Notably, observations at SNOTEL stations and modeling revealed no statistically significant change in domain-averaged Rain-on-Snow (ROS) events over the 40-year period, contrasting some regional future estimates of increased ROS frequency. Peak streamflow did not consistently correlate with peak SWE levels, suggesting that other environmental factors such as ROS events and rapid temperature increases (e.g., a 10°C spike observed in 1992) are key drivers of hydrological outcomes. These findings improve understanding of complex subarctic hydrological processes impacting permafrost and highlight the need for adaptive water resource management to mitigate multi-factor risks like flooding and wildfire, requiring proactive planning.

54 ENVIRONMENTAL SCIENCES↗

Flood Estimation under Snowmelt and Rain-on-Snow Processes in Alaska: A Military Installation Perspective

Accurate flood estimation in snow-dominated and high-latitude regions remains challenging due to complex interactions among rainfall, snowmelt, and rain-on-snow (ROS) processes, which are not captured in conventional precipitation-based intensity-duration-frequency (PREC-IDF) curves. This study evaluates the Next-Generation IDF (NG-IDF) framework, an extension of PREC-IDF that incorporates total water available for runoff (precipitation minus changes in snow water equivalent), in two contrasting Alaskan watersheds of Department of Defense (DoD) significance: the Little Chena River Basin (LCRB) in interior Alaska, a tributary of the Chena River that flows through Fort Wainwright and near Eielson Air Force Base, and the Upper Ship Creek Basin (USCB), which drains Joint Base Elmendorf-Richardson near Anchorage. Using long-term SNOTEL observations and event-based rainfall-runoff modeling, NG-IDF and PREC-IDF flood estimates were compared against observation-based flood frequency analyses. Results show that NG-IDF consistently reduces flood-estimation bias by 15–20% relative to PREC-IDF, particularly for snowmelt- and ROS-dominated events. In the interior LCRB, permafrost conditions can substantially amplify flood responses during snowmelt events, an effect not explicitly represented in standard design tools. These findings demonstrate that NG-IDF provides a more physically consistent and transferable framework for flood estimation in cold regions, with potential relevance to mission-critical DoD installation resilience. Projected increases in ROS frequency and permafrost degradation across Alaska further emphasize the need to integrate physics-based hydrologic models that explicitly represent snow and permafrost processes to enhance design resilience and operational readiness for military and other critical infrastructure.

Yan, Hongxiang (ORCID:000000022387403X)↗

GeoRePORT Case Study Examples: Reporting Using the Geothermal Resource Portfolio Optimization and Reporting Technique (GeoRePORT): Preprint

The Geothermal Research Portfolio Optimization & Reporting Technique (GeoRePORT) was developed with funding from the United States Department of Energy's Geothermal Technologies Office (GTO) to assist in identifying and pursuing long-term investment strategies through the development of a resource reporting protocol. GeoRePORT provides scientists and non-scientists a comprehensive and quantitative means of reporting: (1) features intrinsic to geothermal sites (project grade) and, (2) maturity of the development (project readiness). Because geothermal feasibility is not determined by any single factor (e.g. temperature, permeability, permitting), a site's project grade and readiness are evaluated on twelve independent attributes pertaining to geological, technical, or socio-economic feasibility. In this paper, we present case studies illustrating how GeoRePORT can be used to compare geological, technical, and socio-economic attributes between geothermal systems. The consistent and objective assessment protocols used in GeoRePORT allow for comparison of project attributes across unique locations and geological settings. GeoRePORT case studies outline the geological, socio-economic and technical features of four individual geothermal sites: Coso, Chena, Dixie Valley, and White Sands Missile Range. The case studies presented herein illustrate the usefulness of GeoRePORT in evaluating project risk/return, identifying gaps in reported data, evaluating R&D impact, and gathering insights on successes/failures as applicable to future projects.

15 GEOTHERMAL ENERGY↗

GeoRePORT Case Study Examples: Reporting Using the Geothermal Resource Portfolio Optimization and Reporting Technique (GeoRePORT)

The Geothermal Research Portfolio Optimization & Reporting Technique (GeoRePORT) was developed with funding from the United States Department of Energy's Geothermal Technologies Office (GTO) to assist in identifying and pursuing long-term investment strategies through the development of a resource reporting protocol. GeoRePORT provides scientists and non-scientists a comprehensive and quantitative means of reporting: (1) features intrinsic to geothermal sites (project grade) and, (2) maturity of the development (project readiness). Because geothermal feasibility is not determined by any single factor (e.g. temperature, permeability, permitting), a site's project grade and readiness are evaluated on twelve independent attributes pertaining to geological, technical, or socio-economic feasibility. In this paper, we present case studies illustrating how GeoRePORT can be used to compare geological, technical, and socio-economic attributes between geothermal systems. The consistent and objective assessment protocols used in GeoRePORT allow for comparison of project attributes across unique locations and geological settings. GeoRePORT case studies outline the geological, socio-economic and technical features of four individual geothermal sites: Coso, Chena, Dixie Valley, and White Sands Missile Range. The case studies presented herein illustrate the usefulness of GeoRePORT in evaluating project risk/return, identifying gaps in reported data, evaluating R&D impact, and gathering insights on successes/failures as applicable to future projects.

40 EE - Geothermal Technologies Office (EE-4G)↗

GeoRePORT Case Study Examples: Reporting Using the Geothermal Resource Portfolio Optimization and Reporting Technique (GeoRePORT)

The GeoRePORT System is based on the concept that a geothermal system can be described both in terms of the quality of the geothermal resource as it relates to the potential to extract heat (Resource Grade) and the progress of research and development over the lifetime of the project (Project Readiness Level). Case study examples using the GeoRePORT tool are shared and discussed.

15 GEOTHERMAL ENERGY↗