Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Chemometrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Practical Guide to Chemometric Analysis of Optical Spectroscopic Data

The methodology and mathematical treatment of several classic multivariate methods for the analysis of spectroscopic data is demonstrated in a straightforward way that can be used as a basis for teaching an undergraduate introductory course on chemometric analysis. The multivariate techniques of classical least squares (CLS), principal component regression (PCR), and partial least squares (PLS), as well as the univariate Beer’s law method have been described and compared, building students’ understanding by starting with the univariate method and progressing step by step into the multivariate methods. Equations for the production of regression vectors from training set spectral data is described and their use demonstrated for the prediction of constituent concentrations on a separate validation set of spectra. Extreme care is taken to ensure consistency in variable formatting of data matrices. This provides a key foundation to understanding how spectral data are manipulated using these different mathematical approaches for building quantitative regression models. Each method is applied to a real-world data set, and the results are discussed to show students the types of information that can be gleaned from each method. A training set comprised of 20 infrared absorbance spectra containing 3 constituents (benzene, polystyrene, and gasoline) of known composition are used to demonstrate the matrix operations for each regression method. A separate set of 12 real-world napalm samples (containing benzene, polystyrene and gasoline) are used as a validation set to demonstrate the ability to utilize the regression models on an unknown dataset. A toolbox (PNNL Chemometric Toolbox) written in MATLAB language is supplied in the Supplemental Information file and can be used as a companion for understanding the development and deployment of the chemometric algorithms described in this paper. The datasets of the infrared spectra are also supplied, allowing users to build and inspect the chemometric models on their own. Finally, the Toolbox includes scripts to assist users in loading their own datasets into MATLAB and performing CLS, PCR, and PLS on their data.

Upper-Division Undergraduate, Analytical Chemistry↗

Quantification of Raman-Interfering Polyoxoanions for Process Analysis: Comparison of Different Chemometric Models and a Demonstration on Real Hanford Waste

The Hanford site represents a complicated environmental remediation challenge, remaining from the production of nuclear weapons. Over 100 million gallons of liquid radioactive waste of unknown composition will be chemically processed and vitrified, but the varying chemical composition and highly radioactive nature of the waste preclude the implementation of more developed, offline technologies to determine the composition. The only practical approach to waste treatment will require the significant utilization of real-time, chemometric modeling approaches. Although chemometric approaches have been applied to the analysis of Hanford waste, the models developed were highly tank-specialized, and limited discussion was provided on how models fared with interfering signals. As the tank waste is largely composed of oxoanions, which tend to have interfering Raman spectra, the general question was posed as to what chemometric approach is best suited to accurately quantify analytes in the presence of interfering signals. This was carried out by examining the ability of classical least square (CLS), principal component regression (PCR), partial least square (PLS), and locally weighted regression (LWR) to quantify NO 3 – and CO 3 2– using their bands around 1050 cm –1 . Finally, for all samples, the PLS-based model was found to be the most efficient approach from a model building and application perspective.

54 ENVIRONMENTAL SCIENCES↗

Development of chemometric models to classify solid-state U materials by micro-Raman spectroscopy

Discerning uranium (U) particles found in environmental sampling is of interest for monitoring the peaceful use of nuclear material. In this study, a soft independent modeling of class analogy (SIMCA) library was successfully developed for the classification of a four-class system consisting of α-U 3 O 8 , UO 2 , UO 2 (NO 3 ) 2 ·6H 2 O (UNH), and UO 2 O 2 ·4H 2 O (studtite) by Raman spectroscopy in the presence of matrix particulates and additional outliers. Spectral variability between numerous particles of each type revealed appreciable differences as a function of particle size with respect to hydration state and potential oxide phase within each class. Interclass variability was accounted for using both unsupervised and supervised chemometric models. The supervised SIMCA model displayed reasonable sensitivity for each U class and a high degree of specificity by returning whether a spectrum belonged to one class or not. This work demonstrates how Raman spectral features and chemometrics can be used to distinguish U materials from one another and from matrix materials such as flint clay. Combining the outlined chemometric approach with Raman mapping sequences could provide a rapid, nondestructive technique to characterize the chemical composition of a diverse collection of U compounds amid background samples for environmental sampling, nuclear forensics, and industrial applications.

Actinide↗

Comparing Sensor Fusion and Multimodal Chemometric Models for Monitoring U(VI) in Complex Environments Representative of Irradiated Nuclear Fuel

Optical sensors and chemometric models were leveraged for the quantification of uranium(VI) (0–100 μg mL –1 ), europium (0–150 μg mL –1 ), samarium (0–250 μg mL –1 ), praseodymium (0–350 μg mL –1 ), neodymium (0–1000 μg mL –1 ), and HNO 3 (2–4 M) with varying corrosion product (iron, nickel, and chromium) levels using laser fluorescence, Raman scattering, and ultraviolet–visible–near-infrared absorption spectra. In this paper, an efficient approach to developing and evaluating tens of thousands of partial least-squares regression (PLSR) models, built from fused optical spectra or multimodal acquisitions, is discussed. Each PLSR model was optimized with unique preprocessing combinations, and features were selected using genetic algorithm filters. The 7-factor D-optimal design training set contained just 55 samples to minimize the number of samples. The performance of PLSR models was evaluated by using an automated latent variable selection script. PLS1 regression models tailored to each species outperformed a global PLS2 model. PLS1 models built using fused spectra data and a multimodal (i.e., analyzed separately) approach yielded similar information, resulting in percent root-mean-square error of prediction values of 0.9–5.7% for the seven factors. Further, the optical techniques and data processing strategies established in this study allow for the direct analysis of numerous species without measuring luminescence lifetimes or relying on a standard addition approach, making it optimal for near-real-time, in situ measurements. Nuclear reactor modeling helped bound training set conditions and identified elemental ratios of lanthanide fission products to characterize the burnup of irradiated nuclear fuel. Leveraging fluorescence, spectrophotometry, experimental design, and chemometrics can enable the remote quantification and characterization of complex systems with numerous species, monitor system performance, help identify the source of materials, and enable rapid high-throughput experiments in a variety of industrial processes and fundamental studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring Sulfuric Acid and Temperature Using Raman Spectroscopy and Multivariate Chemometrics

Multivariate regression models were optimized for the quantification of sulfuric acid (H 2 SO 4 ) [0–8 M] and temperature (20 °C–80 °C) in the presence of ammonium sulfate ((NH 4 ) 2 SO 4 [0–0.6 M]) using Raman spectroscopy. Optical vibrational spectroscopy is a useful nondestructive technique for the in situ analysis of complex chemical systems notoriously difficult to monitor in situ and in real-time. Multivariate analysis, a chemometrics method, can be paired with these nondestructive optical methods for determining analyte concentration and speciation in complex solutions, such as dissociated species in polyprotic acids, e.g., H 2 SO 4 . The effect of temperature is often overlooked although it can have a major influence on speciation and the corresponding Raman spectra. Here, in this study, partial least squares regression models were optimized for the quantification of H 2 SO 4 and its two deprotonated forms as a function of temperature. Measuring bisulfate as a function of temperature is particularly challenging owing to changes in the second dissociation constant. A designed training set effectively minimized the sample set size and trained a robust predictive model with percent root mean square error of <3% for H 2 SO 4 . The practical strategy employed here was demonstrated to be effective for building chemometric models that directly account for dynamic temperatures with static samples and is shown to be amenable to flow cell analysis applications with a simple calibration transfer for process monitoring applications.

D-optimal design↗

Chemometrics and visible diffuse reflectance spectroscopy to classify plutonium dioxide

Diffuse reflectance (DR) spectra in the Vis-NIR (∼380–1050 nm) region were acquired for a series of PuO 2 samples with a spot size of about 10 × 10 μm. Two batches of six PuO 2 samples, synthesized approximately 7.5 months apart, were prepared using both Pu(III) and Pu(IV) oxalate precursors at three distinct calcination temperatures (450, 650, and 950 °C). This yielded a total of 12 PuO 2 samples and 433 DR spectra. The DR spectrum of PuO 2 contained numerous peaks in the visible region, and characteristic features were identified with respect to calcination temperature and chemistry. A distinct peak multiplet near 615 nm was observed for samples prepared at low calcination temperatures, and a peak near 660 nm was observed for higher calcination temperatures. A multivariate classification strategy based on principal component analysis (PCA) was developed to distinguish PuO 2 calcination temperatures of 450, 650, and 950 °C with 100 % accuracy. Classification results also indicate the potential to distinguish chemical processing history (i.e., Pu(III) or Pu(IV)) based on the spectra with 72 % accuracy based on k-nearest neighbors applied to the PCA scores. Partial least squares discriminant analysis was used to identify variation among batches with 88 % accuracy and found that peaks near 669, 681, 811, and 970 nm were the most useful for predicting the batch identity. Here, this work demonstrates how micro-diffuse reflectance spectroscopy and chemometrics can be used to classify PuO 2 processing history based on Vis-NIR spectral features. Combining the chemometric approach with mapping sequences could provide a rapid, nondestructive approach to classify Pu oxide materials for environmental, forensics, and nonproliferation applications.

Actinide↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micro-photoluminescence mapping and Chemometrics for the rapid classification of rare earth materials

This article introduces advancements in chemically mapping rare earth materials using photoluminescence (PL) and chemometrics. By leveraging the high sensitivity and selectivity of PL compared to alternative optical techniques, as well as its compatibility with microscopy, we present enhanced capabilities for noninvasive material screening and characterization. Exemplary PL spectra of samarium(III) and europium(III) in oxide, nitrate, and chloride forms demonstrated the ability to extract detailed chemical information of diverse rare earth particles. Additionally, we introduced efficient PL mapping sequences capable of covering a 9 mm diameter carbon tab within minutes, which highlighted the benefits of rapid, large-area imaging. Furthermore, an integrated approach combining PL mapping with principal component analysis and a random forest classifier enabled the resolution of overlapping spectral peaks from different chemistries and provided accurate material classification. In conclusion, these advancements underscored the versatility and robustness of PL for chemically mapping rare earth materials, with the potential to support applications in mining, energy, environmental monitoring, isotope production and beyond.

Chemometrics↗

Comparison of effects from gamma, e-beam and X-ray radiation on multilayer polymer films used in biopharmaceutical devices by chemometric treatment of spectroscopic data

The present study investigated the effects of gamma-ray, electron beam, and X-ray radiation on polymers in EVA/EVOH/EVA multilayer films. Spectroscopic methods, including FTIR and UV–Vis, were employed in conjunction with chemometric treatments such as PCA, SIMPLISMA treatments, and PLS models. The feasibility of dose prediction on multilayer film, given a known dose, is attainable across various irradiation technologies. Both gamma ray and X-ray exhibit comparable effects on the multilayer film, and it is feasible to anticipate the dose released on the film by utilizing UV–Vis spectra or infrared spectra for gamma ray or X-ray of a predetermined dose.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Proof-of-concept chemometric approach for environmental forensic sourcing of crude oil samples using SPME-GC-MS

Environmental exposure to crude oil through seepage and spillage poses risks to the immediate environment and the broader ecosystem as areas along the oil distribution path are affected by the influx of crude petroleum as well as the environmental, economic, and civil unrest that accompanies it. There is a large financial burden associated with the lost resources, including the cost of rehabilitation, and the affected sources of revenue for communities affected by oil spills. As such, it is crucial to determine the responsible parties. This work outlines an environmental forensics approach to determining the source of an un-weathered crude oil sample. The researchers employed solid phase microextraction coupled with gas chromatography mass spectrometry (SPME-GC-MS) to capture and analyze the gaseous components emitted by crude oil samples sourced from five locations. Samples were analyzed using Spearman's rank correlation and 3D covariance analysis. Both chemometric approaches yielded optimal performance results with no misclassifications, true positive rate (TPR) = 100 % and false positive rate (FPR) = 0 %. The similarity metrics calculated by each test noted clear delineations between the values of same-source and differently sourced samples. The Spearman's rank correlation test and 3D covariance calculations both demonstrated the ability to correctly identify sample source origin in this dataset. Finally, the authors outline an approach to the future application of these tests and suggest their joint use in future crude oil sourcing endeavors.

3D covariance mapping↗

Remote quantification of Cm(III) and HNO 3 by fluorescence spectroscopy and chemometrics

A unique approach to remotely quantify Cm(III) (0–100 µg mL −1 ) in HNO 3 (1–12 M) using steady-state laser fluorescence spectroscopy and multivariate regression models was developed. Photoluminescence is amenable to remote measurements using fiber-optic cables and is sensitive to numerous lanthanide and actinide species. In-line measurements can provide feedback to support complex processing in harsh environments (e.g., hot cells) to help guide and optimize radiochemical separations. In this work, Cm(III) spectra were acquired remotely in a glove box as a function of HNO 3 concentration to better understand spectral characteristics and evaluate the utility of multivariate regression models in this system. Furthermore, the Cm(III) fluorescence peak shape, width, position, and intensity changed significantly as a function of HNO 3 concentration, likely because of the displacement of emission quenching inner-sphere water molecules and complexation with nitrate ions. Despite significant covariance and nonlinearity in the data, a D-optimal design strategy successfully minimized training set sample size and was used to build effective partial least squares regression models for Cm(III) and HNO 3 concentrations without a priori knowledge of solution conditions. Chemometrics for modeling complex fluorescence spectra are promising and may find widespread applicability for online analysis in numerous chemical systems found in the nuclear field.

Actinide↗

Quantification of Hydrogen Isotopes Utilizing Raman Spectroscopy Paired with Chemometric Analysis for Application across Multiple Systems

On-line and real-time analysis of a chemical process is a major analytical challenge that can drastically change the way the chemical industry or chemical research operates. With in situ analyses, new and powerful understanding of chemistry can be gained; however, building robust tools for long-term monitoring faces many challenges that include compensating for instrument drift, instrument replacement, and sensor or probe replacement. Accounting for these changes by recollecting calibration data and rebuilding quantification models can be costly and time consuming. Here, in this study, methods to overcome these challenges are demonstrated with an application of Raman spectroscopy to monitoring hydrogen isotopes with varied speciation within dynamic gas streams. Specifically, chemical data science tools such as chemometric modeling are leveraged along with several examples of calibration transfer approaches. Furthermore, the optimization of instrument and sensors cell parameters for targeted gas phase analyses is discussed. While the particular focus on hydrogen is highly beneficial within the nuclear energy sector, mechanisms built and demonstrated here are widely applicable to optical spectroscopy monitoring in numerous other chemical systems that can be leveraged in other hazardous processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remote sensing of Pu in uranyl nitrate crystals using reflectance spectroscopy and chemometrics

Remote quantification of Pu(VI) (0–5 mol%) co-crystallized with U in uranyl nitrate hexahydrate (UNH) crystals was achieved in a glove box using reflectance spectroscopy coupled with chemometric modeling. Reflectance spectra were also acquired for Pu(IV) and Np(VI) (0–5 mol%) crystallized with UNH; revealing spectral features consistent with their solution-phase analogs. Principal component analysis revealed Pu(IV/VI) and Np(VI) concentrations as the primary source of variation in the data, informing the development of a supervised partial least squares regression model for Pu(VI). The resulting calibration demonstrated robust performance, with replicate root mean square errors near 10% and quantifiable limits near 0.2 mol% Pu(VI) relative to U. The Pu(VI) remained stable in the crystalline UNH matrix for at least one week with minimal reduction to Pu(IV). Notably, Pu(VI) and Np(VI) incorporation in UNH quenched U(VI) fluorescence while Pu(IV) did not. This study presents a noninvasive, spectroscopic approach for solid-state Pu quantification, with direct implications for material accountability and nuclear nonproliferation monitoring.

Sadergaski, Luke R. [Oak Ridge National Laboratory↗

Study on Closely Related Citrus CMMs based on Chemometrics and Prediction of Components-Targets-Diseases Network by Ingenuity Pathway Analysis

As the representatives of closely related Chinese medicinal materials (CMMs) originated from Rutaceae family, Aurantii fructus immaturus (AFI), Aurantii fructus (AF), Citri reticulatae pericarpium viride (CRPV), and Citri reticulatae pericarpium (CRP) have better functions in regulating qi and promoting gastrointestinal motility. However, differences in the quality of closely related Citrus CMMs have not yet been revealed until now. Herein, this study focused on the systematic differentiation and in-depth understanding of closely related Citrus CMMs by a strategy integrating chemometrics and network pharmacology. Determined by ultra performance liquid chromatography, the content of nine flavonoids showed obvious fluctuations in the decoction pieces from different species (Citrus aurantium Linnaeus and Citrus reticulate Blanco) with decreasing levels in the samples of ripe fruits. Decoction pieces from the different species and ripening stages were well distinguished by orthogonal projection to latent structure-discriminate analysis (OPLS-DA) and cluster analysis. As a result, four active components including narirutin, naringenin, hesperidin, and 3,5,6,7,8,3′,4′-heptemthoxyflavone were filtered out by variable importance for the projection (VIP) value (VIP > 1.0), which were regarded as chemotaxonomic markers. Furthermore, a components-targets-diseases network was constructed via ingenuity pathway analysis (IPA), and the correlations were predicted between four chemotaxonomic markers, 223 targets, and three diseases including colitis, breast cancer, and colorectal cancer. The obtained results will be of great significance for identifying closely related Citrus CMMs and conduce to improving the resource utilization of CMMs.

Mu, Qixuan↗

Quantifying neptunium oxidation states in nitric acid through spectroelectrochemistry and chemometrics

Controlled-potential in situ thin-layer spectropotentiometry was leveraged to generate visible/near-infrared (VIS/NIR) absorption spectral data sets for the development of chemometric models to quantify Np(III/IV/V/VI) oxidation states in HNO 3 . This technology would be valuable in laboratory studies and when monitoring process solutions to guide feed adjustments for radiochemical separations—the performance of which depends on oxidation state. This approach successfully isolated and stabilized Np species in pure (~99%) oxidation states without compromising solution optical properties. Multivariate curve resolution–alternating least squares models were evaluated to resolve spectral and component concentrations from a scan that sequentially produced Np(VI), Np(V), Np(IV), and Np(III) spectra with mixtures of two valences at a time. Although it provided a useful approximation, the method was not able to quantitively resolve each component likely because of rotational ambiguity. Additionally, partial least squares regression models were built from artificial and electrochemically generated VIS/NIR spectral training sets to study the effect of interionic interactions on spectral characteristics. Models built with true Bi-chemical mixtures of coexisting Np oxidation states and spectra generated from additive combinations of pure end points had similar prediction performance. This methodology can be used to directly quantify Np concentration and the ratio of Np oxidation states and other actinides in remote settings such as hot cells.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Leveraging design of experiments to build chemometric models for the quantification of uranium (VI) and HNO3 by Raman spectroscopy

Partial least squares regression (PLSR) and support vector regression (SVR) models were optimized for the quantification of U(VI) (10–320 g L −1 ) and HNO 3 (0.6–6 M) by Raman spectroscopy with optimized calibration sets chosen by optimal design of experiments. The designed approach effectively minimized the number of samples in the calibration set for PLSR and SVR by selecting sample concentrations with a quadratic process model, despite complex confounding and covarying spectral features in the spectra. The top PLS2 model resulted in percent root mean square errors of prediction for U(VI), HNO 3 , and NO 3 − of 3.7%, 3.6%, and 2.9%, respectively. PLS1 models performed similarly despite modeling an analyte with a majority linear response (i.e., uranyl symmetric stretch) and another with more covarying vibrational modes (i.e., HNO 3 ). Partial least squares (PLS) model loadings and regression coefficients were evaluated to better understand the relationship between weaker Raman bands and covarying spectral features. Support vector machine models outperformed PLS1 models, resulting in percent root mean square error of prediction values for U(VI) and HNO 3 of 1.5% and 3.1%, respectively. The optimal nonlinear SVR model was trained using a similar number of samples (11) compared with the PLSR model, even though PLS is a linear modeling approach. The generic D-optimal design presented in this work provides a robust statistical framework for selecting training set samples in disparate two-factor systems. This approach reinforces Raman spectroscopy for the quantification of species relevant to the nuclear fuel cycle and provides a robust chemometric modeling approach to bolster online monitoring in challenging process environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemometric analysis for extraction of individual fluorescence spectrum and lifetimes from a target mixture

The present invention is a system for chemometric analysis for the extraction of the individual component fluorescence spectra and fluorescence lifetimes from a target mixture. The present invention combines a processor with an apparatus for generating an excitation signal to transmit at a target mixture and an apparatus for detecting the emitted signal from the target mixture. The present invention extracts the individual fluorescence spectrum and fluorescence lifetime measurements from the frequency and wavelength data acquired from the emitted signal. The present invention uses an iterative solution that first requires the initialization of several decision variables and the initial approximation determinations of intermediate matrices. The iterative solution compares the decision variables for convergence to see if further approximation determinations are necessary. If the solution converges, the present invention then determines the reduced best fit error for the analysis of the individual fluorescence lifetime and the fluorescence spectrum before extracting the individual fluorescence lifetime and fluorescence spectrum from the emitted signal of the target mixture.

Hallidy, William H.↗

Rapid and high-throughput determination of sorghum ( Sorghum bicolor ) biomass composition using near infrared spectroscopy and chemometrics

Compositional characterization of biomass is vital for the biofuel industry. Traditional wet chemistry-based methods for analyzing biomass composition are laborious, time-consuming, and require extensive use of chemical reagents as well as highly skilled personnel. In this study, near-infrared (NIR) spectroscopy was used to quickly assess the composition of above-ground vegetative biomass from 113 diverse, photoperiod-sensitive, biomass-type sorghum (Sorghum bicolor) accessions cultivated under field conditions in Central Illinois. Biomass samples were analyzed using NIR spectra collected in the spectral range of 867–2536 nm, with their chemical compositions determined following the National Renewable Energy Laboratory (NREL) protocol. Advanced spectral pre-treatment and band selection techniques were utilized to develop calibration models using partial least squares regression (PLSR). The models’ effectiveness was assessed through cross-validation and independent data tests. The predictions for moisture, ash, extractives, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin were accurate and reliable, demonstrating the capability of NIR spectroscopy to provide rapid and precise characterization of sorghum biomass. The results demonstrated that NIR spectroscopy is an efficient tool for rapidly characterizing sorghum biomass, making it a sustainable option for screening desirable feedstock for biofuel or bioproduct production.

09 BIOMASS FUELS↗