Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Charged particle optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Charged Particle Optics in Circular Higgs Factory

Similar to a super B-factory, a circular Higgs factory will require strong focusing systems near the interaction points and a low-emittance lattice in arcs to achieve a factory luminosity. At electron beam energy of 120 GeV, beamstrahlung effects during the collision pose an additional challenge to the collider design. In particular, a large momentum acceptance at 2 percent level is necessary to retain an adequate beam lifetime. This turns out to be the most challenging aspect in the design of circular Higgs factory. In this paper, an example will be provided to illustrate the beam dynamics in circular Higgs factory, emphasizing on the chromatic optics. Basic optical modules and advanced analysis will be presented. Most important, we will show that 2% momentum aperture is achievable

43 PARTICLE ACCELERATORS↗

Functionally graded magnetic materials: a perspective to advance charged particle optics through compositional engineering

Additive manufacturing has ushered in a new paradigm of bottom-up materials-by-design of spatially non-uniform materials. Functionally graded materials have locally tailored compositions to provide optimized global properties and performance. In this letter, we propose an opportunity for the application of graded magnetic materials as lens elements for charged particle optics. A Hiperco50/Hymu80 (FeCo-2 V/Fe-80Ni-5Mo) graded magnetic alloy was successfully additively manufactured via Laser Directed Energy Deposition with spatially varying magnetic properties. The compositional gradient is then applied using computational simulations to demonstrate how a tailored material can enhance the magnetic performance of a critical, image-forming component of a transmission electron microscope.

36 MATERIALS SCIENCE↗

Quantum aspects of charged-particle beam optics

The classical treatments have been successful in designing numerous charged-particle devices. It is natural to develop a quantum prescription, since all systems are fundamentally quantum mechanical in nature. The quantum theory leads to new insights accompanied with wavelength-dependent contributions. The action of a magnetic quadrupole is derived from the Dirac equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling a Miniaturized Scanning Electron Microscope Focusing Column - Lessons Learned in Electron Optics Simulation

This presentation discusses work done to assess the design of a focusing column in a miniaturized Scanning Electron Microscope (SEM) developed at the NASA Marshall Space Flight Center (MSFC) for use in-situ on the Moon-in particular for mineralogical analysis. The MSFC beam column design uses purely electrostatic fields for focusing, because of the severe constraints on mass and electrical power consumption imposed by the goals of lunar exploration and of spaceflight in general. The resolution of an SEM ultimately depends on the size of the focused spot of the scanning beam probe, for which the stated goal here is a diameter of 10 nanometers. Optical aberrations are the main challenge to this performance goal, because they blur the ideal geometrical optical image of the electron source, effectively widening the ideal spot size of the beam probe. In the present work the optical aberrations of the mini SEM focusing column were assessed using direct tracing of non-paraxial rays, as opposed to mathematical estimates of aberrations based on paraxial ray-traces. The geometrical ray-tracing employed here is completely analogous to ray-tracing as conventionally understood in the realm of photon optics, with the major difference being that in electron optics the lens is simply a smoothly varying electric field in vacuum, formed by precisely machined electrodes. Ray-tracing in this context, therefore, relies upon a model of the electrostatic field inside the focusing column to provide the mathematical description of the "lens" being traced. This work relied fundamentally on the boundary element method (BEM) for this electric field model. In carrying out this research the authors discovered that higher accuracy in the field model was essential if aberrations were to be reliably assessed using direct ray-tracing. This led to some work in testing alternative techniques for modeling the electrostatic field. Ultimately, the necessary accuracy was attained using a BEM/Fourier series hybrid approach. The presentation will give background remarks about the MSFC mini Lunar SEM concept and electron optics modeling, followed by a description of the alternate field modeling techniques that were tried, along with their incorporation into a ray-trace simulation. Next, the validation of this simulation against commercially available software will be discussed using an example lens as a test case. Then, the efficacy of aberration assessment using direct ray-tracing will be demonstrated, using this same validation case. The discussion will include practical error checks of the field solution. Finally, the ray-trace assessment of the MSFC mini Lunar SEM concept will be shown and discussed. The authors believe this presentation will be of general interest to practitioners of modeling and simulation, as well as those with a general optics background. Because electron optics and photon optics share many basic concepts (e.g., lenses, images, aberrations, etc.), the appeal of this presentation need not be restricted to just those interested in charged particle optics.

Modeling Miniaturizing Scanning↗

Beam and Spin Optics Simulation Tutorials, Using Zgoubi

This tutorial is an introduction to the classical cyclotron, with some hints at spin dynamics, hands-on: by numerical simulation. It begins with a brief reminder of the historic context, and then introduces the theoretical material needed for the simulation exercises, which follow. Basic charge particle optics and acceleration concepts are addressed, including closed orbit in a cyclic accelerator, weak focusing in a dipole magnet, periodic transverse motion, revolution period and isochronism, voltage gap and resonant acceleration, the cyclotron equation.

43 PARTICLE ACCELERATORS↗

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗

Turbomolecular Pumps for Holding Gases in Open Containers

Proposed special-purpose turbomolecular pumps denoted turbotraps would be designed, along with mating open containers, to prevent the escape of relatively slowly (thermal) moving gas molecules from the containers while allowing atoms moving at much greater speeds to pass through. In the original intended applications, the containers would be electron-attachment cells, and the contained gases would be vapors of alkali metal atoms moving at thermal speeds that would be of the order of a fraction of 300 meters per second. These cells would be parts of apparatuses used to measure fluxes of neutral atoms incident at kinetic energies in the approximate range of 10 eV to 10 keV (corresponding to typical speeds of the order of 40,000 m/s and higher). The incident energetic neutral atoms would pass through the cells, wherein charge-exchange reactions with the alkali metal atoms would convert the neutral atoms to negative ions, which, in turn, could then be analyzed by use of conventional charged-particle optics.

Keller, John W.↗

Vavilov–Cherenkov radiation when cosmic rays pass through the relic photon gas and when fast charged particles traverse an optical laser beam

Using a new [9, 10] quantum theory of Vavilov–Cherenkov radiation (VCR) based on Abraham’s theory, we show that a threshold VCR effect can be excited by the relic photon gas when relativistic charged cosmic-ray particles with γ ≥ γ{sub th} ≈ 1.9 × 10{sup 10} (where γ{sup –2} = 1–v{sup 2}/c{sup 2}, v is the particle speed, and c is the speed of light in a vacuum) pass through it. This is compatible with the well-known GZK cutoff [7, 8] at γ ≈ 10{sup 11}. We have obtained the condition γ > γ{sub th} ≈ 2.1 × 10{sup 2} for the appearance of VCR when a sufficiently fast charged particle (an electron, a proton, or a nucleus) passes through intense laser radiation. This condition ensures that VCR can be observed experimentally (e.g., on the Large Hadron Collider) without invoking any additional conditions required from the currently existing estimate of γth > 8.8 × 10{sup 4} [13] based on the now universally accepted quantum theory of VCR, which follows from Minkowski’s theory (and which gives an estimate of γ > 10{sup 21} when excited by the relic photon gas).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The response of thermally and optically stimulated luminescence from Al2O3:C to high-energy heavy charged particles

The thermoluminescence (TL) and optically stimulated luminescence (OSL) response of Al2O3 dosimeters to high-energy heavy charged particles (HCP) has been studied using the heavy ion medical accelerator at Chiba, Japan. The samples were Al2O3 single-crystal chips, of the type usually known as TLD-500, and Luxel(TM) dosimeters (Al2O3:C powder in plastic) from Landauer Inc. The samples were exposed to 4He (150 MeV/u), 12C (400 MeV/u), 28Si (490 MeV/us) and 56Fe (500 MeV/u) ions, with linear energy transfer values covering the range from 2.26 to 189 keV/micrometers in water and doses from 1 to 100 mGy (to water). A 90Sr/90Y beta source, calibrated against a 60Co secondary standard, was used for calibration purposes. For OSL, we used both continuous-wave OSL measurements (CW-OSL, using green light stimulation at 525 nm) and pulsed OSL measurements (POSL, using 532 nm stimulation from a Nd:YAG Q-switched laser). The efficiencies (eta HCP, gamma) of the different HCPs at producing OSL or TL were observed to depend not only upon the linear energy transfer (LET) of the HCP, but also upon the sample type (single crystal chip or Luxel(TM)) and the luminescence method used to define the signal--i.e. TL, CW-OSL initial intensity, CW-OSL total area, or POSL. Observed changes in shape of the decay curve lead to potential methods for extracting LET information of unknown radiation fields. A discussion of the results is given, including the potential use of OSL from Al2O3 in the areas of space radiation dosimetry and radiation oncology. c2004 Elsevier Ltd. All rights reserved.

Heavy Ions↗

Two bright, optically clear, intrinsic fast-neutron and charged-particle detector materials for neutron imaging and other applications

Two optically clear, bright, scintillating ZnS materials have been identified that, like previous opaque ZnS scintillators, are excellent charged particle detectors. We show that ZnS is a good fast-neutron-to charged-particle converter making optically clear ZnS an intrinsic fast-neutron detector that does not require layering or mixing of converter materials and scintillator materials, and removes the limitations imposed by opaque ZnS scintillator materials used for more than a century. Thermal neutron detection using optically clear 6 LiF or 10 BN and clear ZnS may benefit from improved spatial resolution and light transmission. Properties and tests of clear scintillating ZnS are described. Fast-neutron imaging applications benefit from increased efficiency of these scintillators, minimal scattering in the scintillator, and increased useful detector volume. Charged particle and fast-neutron detectors have numerous applications in nuclear non-proliferation and security, nuclear and particle physics, and non-destructive testing and environmental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-DE-BRA-05: Monte Carlo Simulation of a Novel Multi-Layer MV Imager

Purpose: To develop and validate a Monte Carlo (MC) model of a novel multi-layer imager (MLI) for megavolt (MV) energy beams. The MC model will enable performance optimization of the MLI design for clinical applications including patient setup verification, tumor tracking and MVCBCT. Methods: The MLI is composed of four layers of converter, scintillator and light detector, each layer similar to the current clinical AS1200 detector (Varian Medical Systems, Inc). The MLI model was constructed using the Geant4 Application for Tomographic Emission (GATE v7.1) and includes interactions for x-ray photons, charged particles and optical photons. Computational experiments were performed to assess Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE) and Noise Power Spectrum normalized by photon fluence and average detector signal (qNNPS). Results were compared with experimental measurements. The current work incorporates, in one model, the complete chain of events occurring in the imager; i.e. starting from x-ray interaction to charged particle transport and energy deposition to subsequent generation, interactions and detection of optical photons. Results: There is good agreement between measured and simulated MTF, qNNPS and DQE values. Normalized root mean squared error (NRMSE) between measured and simulated values over all four layers was 2.18%, 2.43% and 6.05% for MTF, qNNPS and DQE respectively. The relative difference between simulated and measured values for qNNPS(0) was 1.68% and 1.57% for DQE(0). Current results were obtained using a 6MV Varian Truebeam™ spectrum. Conclusion: A comprehensive Monte Carlo model of the MLI prototype was developed to allow optimization of detector components. The model was assessed in terms of imaging performance using standard metrics (i.e. MTF, qNNPS, DQE). Good agreement was found between simulated and measured values. The model will be used to assess alternative detector constructions to facilitate advanced clinical imaging applications including MV-CBCT and tumor tracking. The project was supported, partially, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Measuring electrically charged particle fluxes in space using a fiber optic loop sensor

The purpose of this program was to demonstrate the potential of a fiber optic loop sensor for the measurement of electrically charged particle fluxes in space. The key elements of the sensor are a multiple turn loop of low birefringence, single mode fiber, with a laser diode light source, and a low noise optical receiver. The optical receiver is designed to be shot noise limited, with this being the limiting sensitivity factor for the sensor. The sensing element is the fiber optic loop. Under a magnetic field from an electric current flowing along the axis of the loop, there is a non-vanishing line integral along the fiber optic loop. This causes a net birefringence producing two states of polarization whose phase difference is correlated to magnetic field strength and thus, current in the optical receiver electronic processing. The objectives in this program were to develop a prototype laser diode powered fiber optic sensor. The performance specification of a minimum detectable current density of 1 (mu)amp/sq m-(radical)Hz, should be at the shot noise limit of the detection electronics. OPTRA has successfully built and tested a 3.2 m diameter loop with 137 turns of low birefringence optical fiber and achieved a minimum detectable current density of 5.4 x 10(exp-5) amps/(radical)Hz. If laboratory space considerations were not an issue, with the length of optical fiber available to us, we would have achieved a minimum detectable current density of 4 x 10(exp -7) amps/(radical)Hz.

Source record↗

Optically stimulated luminescence and thermoluminescence efficiencies for high-energy heavy charged particle irradiation in Al2O3:C

The thermally and optically stimulated luminescence (TL and OSL) response to high energy heavy-charged particles (HCPs) was investigated for two types of Al2O3:C luminescence dosimeters. The OSL signal was measured in both continuous-wave (CW) and pulsed mode. The efficiencies of the HCPs at producing TL or OSL, relative to gamma radiation, were obtained using four different HCPs beams (150 MeV/u 4He, 400 MeV/u 12C, 490 MeV/u 28Si, and 500 MeV/u 56Fe). The efficiencies were determined as a function of the HCP linear energy transfer (LET). It was observed that the efficiency depends on the type of detector, measurement technique, and the choice of signal. Additionally, it is shown that the shape of the CW-OSL decay curve from Al2O3:C depends on the type of radiation, and, in principle, this can be used to extract information concerning the LET of an unknown radiation field. The response of the dosimeters to low-LET radiation was also investigated for doses in the range from about 1-1000 Gy. These data were used to explain the different efficiency values obtained for the different materials and techniques, as well as the LET dependence of the CW-OSL decay curve shape. c2003 Elsevier Ltd. All rights reserved.

Thermoluminescent Dosimetry/instrumentation/method↗

A conceptual design of circular Higgs factory

Similar to a super B-factory, a circular Higgs factory (CHF) will require strong focusing systems near the interaction points and a low-emittance lattice in the arcs to achieve a factory luminosity. At electron beam energy of 125 GeV, beamstrahlung effects during the collision pose an additional challenge to the collider design. In particular, a large momentum acceptance at the 2% level is necessary to retain an adequate beam lifetime. This turns out to be the most challenging aspect in the design of a CHF. In this paper, an example will be provided to illustrate the beam dynamics in a CHF, emphasizing the chromatic optics. Basic optical modules and advanced analysis will be presented. Most importantly, we will show that 2% momentum aperture is achievable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preserving Simplecticity in the Numerical Integration of Linear Beam Optics

Presented are mathematical tools and methods for the development of numerical integration techniques that preserve the symplectic condition inherent to mechanics. The intended audience is for beam physicists with backgrounds in numerical modeling and simulation with particular attention to beam optics applications. The paper focuses on Lie methods that are inherently symplectic regardless of the integration accuracy order. Section 2 provides the mathematically tools used in the sequel and necessary for the reader to extend the covered techniques. Section 3 places those tools in the context of charged-particle beam optics; in particular linear beam optics is presented in terms of a Lie algebraic matrix representation. Section 4 presents numerical stepping techniques with particular emphasis on a third-order leapfrog method. Section 5 discusses the modeling of field imperfections with particular attention to the fringe fields of quadrupole focusing magnets. The direct computation of a third order transfer matrix for a fringe field is shown.

43 PARTICLE ACCELERATORS↗