Role of Pb/PbSO 4 Morphologies in Dynamic Charge Acceptance of Lead Acid Batteries
The dynamic charge acceptance (DCA) of negative pastes in lead acid batteries is studied using a continuum level model that is validated against in situ X-ray diffraction experiments. The model matches the current transient during a ten-minute, 2.4 V charge at 80% state of charge (SOC) using a distribution of PbSO 4 particles. <2% by volume of small, reactive particles is shown to provide ∼50% of the capacity during the first ten seconds. Increases in DCA with increasing carbon content are captured with increasing lead surface area. The increase in DCA when the 2.4 V charge is done after discharging to 80% SOC (vs charging to 80%) is captured by reducing the PbSO 4 particle sizes. It is hypothesized that the lower DCA after charging is caused by the absence of smaller particles that were consumed during the initial charge to 80% SOC, which is confirmed from X-ray measurements. Finally, two-particle case studies show that reducing the PbSO 4 particle size is more effective for increasing DCA than increasing the PbSO 4 dissolution rate alone. For a given lead surface area, the optimal DCA occurs when the particle sizes are large enough to avoid blocking the surface but small enough to provide dissolution/diffusion improvements.