Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centroid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A multiresolution method for climate system modeling: application of spherical centroidal Voronoi tessellations

During the next decade and beyond, climate system models will be challenged to resolve scales and processes that are far beyond their current scope. Each climate system component has its prototypical example of an unresolved process that may strongly influence the global climate system, ranging from eddy activity within ocean models, to ice streams within ice sheet models, to surface hydrological processes within land system models, to cloud processes within atmosphere models. These new demands will almost certainly result in the develop of multiresolution schemes that are able, at least regionally, to faithfully simulate these fine-scale processes. Spherical centroidal Voronoi tessellations (SCVTs) offer one potential path toward the development of a robust, multiresolution climate system model components. SCVTs allow for the generation of high quality Voronoi diagrams and Delaunay triangulations through the use of an intuitive, user-defined density function. In each of the examples provided, this method results in high-quality meshes where the quality measures are guaranteed to improve as the number of nodes is increased. Real-world examples are developed for the Greenland ice sheet and the North Atlantic ocean. Idealized examples are developed for ocean–ice shelf interaction and for regional atmospheric modeling. In addition to defining, developing, and exhibiting SCVTs, we pair this mesh generation technique with a previously developed finite-volume method. Our numerical example is based on the nonlinear, shallow water equations spanning the entire surface of the sphere. This example is used to elucidate both the potential benefits of this multiresolution method and the challenges ahead.

58 GEOSCIENCES↗

A further investigation of the centroid-to-centroid method for stereotactic lung radiotherapy: A phantom study

Purpose: Our previous study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] proposed a deformable-registration-based patient setup strategy called the centroid-to-centroid (CTC) method, which can perform an accurate alignment of internal-target-volume (ITV) centroids between averaged four-dimensional computed tomography and cone-beam computed tomography (CBCT) images. Scenarios with variations between CBCT and simulation CT caused by irregular breathing and/or tumor change were not specifically considered in the patient study [B. Lu et al., “A patient alignment solution for lung SBRT setups based on a deformable registration technique,” Med. Phys. 39(12), 7379–7389 (2012)] due to the lack of both a sufficiently large patient data sample and a method of tumor tracking. The aim of this study is to thoroughly investigate and compare the impacts of breathing pattern and tumor change on both the CTC and the translation-only (T-only) gray-value mode strategies by employing a four-dimensional (4D) lung phantom.Methods: A sophisticated anthropomorphic 4D phantom (CIRS Dynamic Thorax Phantom model 008) was employed to simulate all desired respiratory variations. The variation scenarios were classified into four groups: inspiration to expiration ratio (IE ratio) change, tumor trajectory change, tumor position change, tumor size change, and the combination of these changes. For each category the authors designed several scenarios to demonstrate the effects of different levels of breathing variation on both of the T-only and the CTC methods. Each scenario utilized 4DCT and CBCT scans. The ITV centroid alignment discrepancies for CTC and T-only were evaluated. The dose-volume-histograms (DVHs) of ITVs for two extreme cases were analyzed.Results: Except for some extreme cases in the combined group, the accuracy of the CTC registration was about 2 mm for all cases for both the single and the combined scenarios. The performance of the CTC method was insensitive to region-of-registration (ROR) size selections, as suggested by the comparable accuracy between 1 and 2 cm expansions of the ROR selections for the method. The T-only method was suitable for some single scenarios, such as trajectory variation, position variation, and size variation. However, for combined scenarios and/or a large variation in the IE ratio, the T-only method failed to produce reasonable registration results (within 3 mm). The discrepancy was close to, or even greater than, 1 cm. In addition, unlike the CTC method, the T-only method was sensitive to the ROR size selection. The DVH analysis suggested that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.Conclusions: The phantom study demonstrated that the CTC method was reliable for scenarios in which breathing pattern variation was involved. The T-only gray value method worked for some scenarios, but not for scenarios that involved an IE ratio variation. For scenarios involving position variation, the T-only method worked only with a careful selection of the ROR, whereas the CTC method was independent of ROR size as long as the ITVs were included in the ROR. One indication of the dose consequence analysis was that a large ITV to PTV margin should be considered if a breathing pattern variation is observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Centroid and Envelope Dynamics of High-Intensity Charged-Particle Beams in an External Focusing Lattice and Oscillating Wobbler

The centroid and envelope dynamics of a high-intensity charged-particle beam are investigated as a beam smoothing technique to achieve uniform illumination over a suitably chosen region of the target for applications to ion-beam-driven high energy density physics and heavy ion fusion. The motion of the beam centroid projected onto the target follows a smooth pattern to achieve the desired illumination, for improved stability properties during the beam-target interaction. The centroid dynamics is controlled by an oscillating 'wobbler', a set of electrically biased plates driven by rf voltage.

43 PARTICLE ACCELERATORS↗

Centroid stabilization for laser alignment to corner cubes: designing a matched filter

Automation of image-based alignment of National Ignition Facility high energy laser beams is providing the capability of executing multiple target shots per day. One important alignment is beam centration through the second and third harmonic generating crystals in the final optics assembly (FOA), which employs two retroreflecting corner cubes as centering references for each beam. Beam-to-beam variations and systematic beam changes over time in the FOA corner cube images can lead to a reduction in accuracy as well as increased convergence durations for the template-based position detector. A systematic approach is described that maintains FOA corner cube templates and guarantees stable position estimation.

42 ENGINEERING↗

Centroid and moments of an area using a digitizer

The centroid and moments of an area program provides the centroid, moments of inertia, product of inertia, radii of gyration, and area of any closed planar geometric figure. The figure must be available in graphic form and is digitized once with chart digitizer (graphic tablet). The digitizer origin may be set anywhere on the digitizer table. After digitizing, fifteen quantities are calculated and displayed: (1) area (2) moment of inertia of area with respect to digitizer x-axis, (3) moment of inertia of area with respect to digitizer y-axis, (4) product of inertia of area with respect to digitizer axes, (5) first moment of x for digitizer axes, (6) first moment of y for digitizer axes, (7) x coordinate of centroid, (8) y coordinate of centroid, (9) moment of area inertia of with respect to x axis through centroid, (10) moment of inertia of area with respect to y axis through centroid, (11) product inertia of area with respect to x and y axes through centroid, (12) polar moment of inertia of area around centroid, (13) radius of gyration about digitizer x axis, (14) radius of gyration about digitizer y-axis; and (15) variance in the x-direction.

Patch, R. W.↗

A Doppler centroid estimation algorithm for SAR systems optimized for the quasi-homogeneous source

Radar signal processing applications frequently require an estimate of the Doppler centroid of a received signal. The Doppler centroid estimate is required for synthetic aperture radar (SAR) processing. It is also required for some applications involving target motion estimation and antenna pointing direction estimation. In some cases, the Doppler centroid can be accurately estimated based on available information regarding the terrain topography, the relative motion between the sensor and the terrain, and the antenna pointing direction. Often, the accuracy of the Doppler centroid estimate can be improved by analyzing the characteristics of the received SAR signal. This kind of signal processing is also referred to as clutterlock processing. A Doppler centroid estimation (DCE) algorithm is described which contains a linear estimator optimized for the type of terrain surface that can be modeled by a quasi-homogeneous source (QHS). Information on the following topics is presented: (1) an introduction to the theory of Doppler centroid estimation; (2) analysis of the performance characteristics of previously reported DCE algorithms; (3) comparison of these analysis results with experimental results; (4) a description and performance analysis of a Doppler centroid estimator which is optimized for a QHS; and (5) comparison of the performance of the optimal QHS Doppler centroid estimator with that of previously reported methods.

Jin, Michael Y.↗

ASTROMETRIC IMAGE CENTROID DISPLACEMENTS DUE TO GRAVITATIONAL MICROLENSING BY THE ELLIS WORMHOLE

Continuing work initiated in an earlier publication, we study the gravitational microlensing effects of the Ellis wormhole in the weak-field limit. First, we find a suitable coordinate transformation, such that the lens equation and analytic expressions of the lensed image positions can become much simpler. Second, we prove that two images always appear for the weak-field lens by the Ellis wormhole. By using these analytic results, we discuss astrometric image centroid displacements due to gravitational microlensing by the Ellis wormhole. The astrometric image centroid trajectory by the Ellis wormhole is different from the standard one by a spherical lensing object that is expressed by the Schwarzschild metric. The anomalous shift of the image centroid by the Ellis wormhole lens is smaller than that by the Schwarzschild lens, provided that the impact parameter and the Einstein ring radius are the same. Therefore, the lensed image centroid by the Ellis wormhole moves slower. Such a difference, although it is very small, will be, in principle, applicable for detecting or constraining the Ellis wormhole by using future high-precision astrometry observations. In particular, the image centroid position gives us additional information, so that the parameter degeneracy existing in photometric microlensing can be partially broken. The anomalous shift reaches the order of a few micro arcseconds, if our galaxy hosts a wormhole with throat radius larger than 10{sup 5} km. When the source moves tangentially to the Einstein ring, for instance, the maximum position shift of the image centroid by the Ellis wormhole is 0.18 normalized by the Einstein ring radius. For the same source trajectory, the maximum difference between the centroid displacement by the Ellis wormhole lens and that by the Schwarzschild one with the same Einstein ring radius is -0.16 in the units of the Einstein radius, where the negative means that the astrometric displacement by the Ellis wormhole lens is smaller than that by the Schwarzschild one.

79 ASTRONOMY AND ASTROPHYSICS↗

Adaptive thresholding and dynamic windowing method for automatic centroid detection of digital Shack-Hartmann wavefront sensor

A Shack-Hartmann wavefront sensor (SWHS) splits the incident wavefront into many subsections and transfers the distorted wavefront detection into the centroid measurement. The accuracy of the centroid measurement determines the accuracy of the SWHS. Many methods have been presented to improve the accuracy of the wavefront centroid measurement. However, most of these methods are discussed from the point of view of optics, based on the assumption that the spot intensity of the SHWS has a Gaussian distribution, which is not applicable to the digital SHWS. In this paper, we present a centroid measurement algorithm based on the adaptive thresholding and dynamic windowing method by utilizing image processing techniques for practical application of the digital SHWS in surface profile measurement. The method can detect the centroid of each focal spot precisely and robustly by eliminating the influence of various noises, such as diffraction of the digital SHWS, unevenness and instability of the light source, as well as deviation between the centroid of the focal spot and the center of the detection area. The experimental results demonstrate that the algorithm has better precision, repeatability, and stability compared with other commonly used centroid methods, such as the statistical averaging, thresholding, and windowing algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Centroid and Envelope Eynamics of Charged Particle Beams in an Oscillating Wobbler and External Focusing Lattice for Heavy Ion Fusion Applications

Recent heavy ion fusion target studies show that it is possible to achieve ignition with direct drive and energy gain larger than 100 at 1MJ. To realize these advanced, high-gain schemes based on direct drive, it is necessary to develop a reliable beam smoothing technique to mitigate instabilities and facilitate uniform deposition on the target. The dynamics of the beam centroid can be explored as a possible beam smoothing technique to achieve a uniform illumination over a suitably chosen region of the target. The basic idea of this technique is to induce an oscillatory motion of the centroid for each transverse slice of the beam in such a way that the centroids of different slices strike different locations on the target. The centroid dynamics is controlled by a set of biased electrical plates called 'wobblers'. Using a model based on moments of the Vlasov-Maxwell equations, we show that the wobbler deflection force acts only on the centroid motion, and that the envelope dynamics are independent of the wobbler fields. If the conducting wall is far away from the beam, then the envelope dynamics and centroid dynamics are completely decoupled. This is a preferred situation for the beam wobbling technique, because the wobbler system can be designed to generate the desired centroid motion on the target without considering its effects on the envelope and emittance. A conceptual design of the wobbler system for a heavy ion fusion driver is briefly summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A quantum generalization of intrinsic reaction coordinate using path integral centroid coordinates

We propose a generalization of the intrinsic reaction coordinate (IRC) for quantum many-body systems described in terms of the mass-weighted ring polymer centroids in the imaginary-time path integral theory. This novel kind of reaction coordinate, which may be called the ''centroid IRC,'' corresponds to the minimum free energy path connecting reactant and product states with a least amount of reversible work applied to the center of masses of the quantum nuclei, i.e., the centroids. We provide a numerical procedure to obtain the centroid IRC based on first principles by combining ab initio path integral simulation with the string method. This approach is applied to NH{sub 3} molecule and N{sub 2}H{sub 5}{sup -} ion as well as their deuterated isotopomers to study the importance of nuclear quantum effects in the intramolecular and intermolecular proton transfer reactions. We find that, in the intramolecular proton transfer (inversion) of NH{sub 3}, the free energy barrier for the centroid variables decreases with an amount of about 20% compared to the classical one at the room temperature. In the intermolecular proton transfer of N{sub 2}H{sub 5}{sup -}, the centroid IRC is largely deviated from the ''classical'' IRC, and the free energy barrier is reduced by the quantum effects even more drastically.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global centroid moment tensor solutions in a heterogeneous earth: the CMT3D catalogue

SUMMARY For over 40 yr, the global centroid-moment tensor (GCMT) project has determined location and source parameters for globally recorded earthquakes larger than magnitude 5.0. The GCMT database remains a trusted staple for the geophysical community. Its point-source moment-tensor solutions are the result of inversions that model long-period observed seismic waveforms via normal-mode summation for a 1-D reference earth model, augmented by path corrections to capture 3-D variations in surface wave phase speeds, and to account for crustal structure. While this methodology remains essentially unchanged for the ongoing GCMT catalogue, source inversions based on waveform modelling in low-resolution 3-D earth models have revealed small but persistent biases in the standard modelling approach. Keeping pace with the increased capacity and demands of global tomography requires a revised catalogue of centroid-moment tensors (CMT), automatically and reproducibly computed using Green's functions from a state-of-the-art 3-D earth model. In this paper, we modify the current procedure for the full-waveform inversion of seismic traces for the six moment-tensor parameters, centroid latitude, longitude, depth and centroid time of global earthquakes. We take the GCMT solutions as a point of departure but update them to account for the effects of a heterogeneous earth, using the global 3-D wave speed model GLAD-M25. We generate synthetic seismograms from Green's functions computed by the spectral-element method in the 3-D model, select observed seismic data and remove their instrument response, process synthetic and observed data, select segments of observed and synthetic data based on similarity, and invert for new model parameters of the earthquake’s centroid location, time and moment tensor. The events in our new, preliminary database containing 9382 global event solutions, called CMT3D for ‘3-D centroid-moment tensors’, are on average 4 km shallower, about 1 s earlier, about 5 per cent larger in scalar moment, and more double-couple in nature than in the GCMT catalogue. We discuss in detail the geographical and statistical distributions of the updated solutions, and place them in the context of earlier work. We plan to disseminate our CMT3D solutions via the online ShakeMovie platform.

58 GEOSCIENCES↗

An Integrated Centroid Finding and Particle Overlap Decomposition Algorithm for Stereo Imaging Velocimetry

An integrated algorithm for decomposing overlapping particle images (multi-particle objects) along with determining each object s constituent particle centroid(s) has been developed using image analysis techniques. The centroid finding algorithm uses a modified eight-direction search method for finding the perimeter of any enclosed object. The centroid is calculated using the intensity-weighted center of mass of the object. The overlap decomposition algorithm further analyzes the object data and breaks it down into its constituent particle centroid(s). This is accomplished with an artificial neural network, feature based technique and provides an efficient way of decomposing overlapping particles. Combining the centroid finding and overlap decomposition routines into a single algorithm allows us to accurately predict the error associated with finding the centroid(s) of particles in our experiments. This algorithm has been tested using real, simulated, and synthetic data and the results are presented and discussed.

McDowell, Mark↗

Transverse centroid oscillations in solenoidially focused beam transport lattices

Linear equations of motion are derived that describe small-amplitude centroid oscillations induced by displacement and rotational misalignments of the focusing solenoids in the transport lattice, dipole steering elements, and initial centroid offset errors. These equations are analyzed in a local rotating Larmor frame to derive complex-variable"alignment functions" and"bending functions" that efficiently describe the characteristics of the centroid oscillations induced by mechanical misalignments of the solenoids and dipole steering elements. The alignment and bending functions depend only on properties of the ideal lattice in the absence of errors and steering and have associated expansion amplitudes set by the misalignments and steering fields. Applications of this formulation are presented for statistical analysis of centroid deviations, calculation of actual lattice misalignments from centroid measurements, and optimal beam steering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data Validation: Difference Imaging and Centroid Analysis

This Design Note describes the theory and application of difference imaging for automated validation of planet candidates in the Data Validation (DV) CSCI. This is one of the diagnostic tools employed in DV for planet candidate validation. The other DV diagnostics are described in separate KADNs and in the reference documents listed below. This document describes the difference image generation process, PRF-based centroiding of the out-of-transit and difference images, computation of quarterly centroid offsets and associated uncertainties, and determination of robust weighted mean centroid offsets/uncertainties over all available quarterly data sets. PRF-based centroiding is performed with calls to a library of functions that is shared with thePhotometric Analysis (PA) and Photometer Data Quality (PDQ) CSCIs. The centroiding library will be the subject of a separate Design Note.

Twicken, Joseph↗

A Statistical Study of Beam Centroid Oscillations in a Solenoid Transport Channel

A recent theory of transverse centroid oscillations in solenoidally focused beam transport lattices presented in Ref. [1] is applied to statistically analyze properties of the centroid orbit in the Neutralized Drift Compression Experiment (NDCX) at the Lawrence Berkeley National Laboratory. Contributions to the amplitude of the centroid oscillations from mechanical misalignments and initial centroid errors exiting the injector are analyzed. Measured values of the centroid appear consistent with expected alignment tolerances. Correction of these errors is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transverse Centroid Oscillations in Solenoidially Focused Beam Transport Lattices

Linear equations of motion are derived that describe small-amplitude centroid oscillations induced by displacement and rotational misalignments of the focusing solenoids in the transport lattice, dipole steering elements, and initial centroid offset errors. These equations are analyzed in a local rotating Larmor frame to derive complex-variable 'alignment functions' and 'bending functions' that efficiently describe the characteristics of the centroid oscillations induced by mechanical misalignments of the solenoids and dipole steering elements. The alignment and bending functions depend only on properties of the ideal lattice in the absence of errors and steering and have associated expansion amplitudes set by the misalignments and steering fields. Applications of this formulation are presented for statistical analysis of centroid deviations, calculation of actual lattice misalignments from centroid measurements, and optimal beam steering.

43 PARTICLE ACCELERATORS↗

Derivation of the Statistical Distribution of the Mass Peak Centroids of Mass Spectrometers Employing Analog-to-Digital Converters and Electron Multipliers

Here, the mass peak centroid is a quantity that is at the core of mass spectrometry (MS). However, despite its central status in the field, models of its statistical distribution are often chosen quite arbitrarily and without attempts at establishing a proper theoretical justification for their use. Recent work has demonstrated that for mass spectrometers employing analog-to-digital converters (ADCs) and electron multipliers, the statistical distribution of the mass peak intensity can be described via a relatively simple model derived essentially from first principles. Building on this result, the following article derives the corresponding statistical distribution for the mass peak centroids of such instruments. It is found that for increasing signal strength, the centroid distribution converges to a Gaussian distribution whose mean and variance are determined by physically meaningful parameters and which in turn determine bias and variability of the m/z measurements of the instrument. Through the introduction of the concept of “pulse-peak correlation”, the model also elucidates the complicated relationship between the shape of the voltage pulses produced by the preamplifier and the mean and variance of the centroid distribution. The predictions of the model are validated with empirical data and with Monte Carlo simulations.

97 MATHEMATICS AND COMPUTING↗