Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Cell signaling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Battery Fault Detection with Saturating Transformers

A battery monitoring system utilizes a plurality of transformers interconnected with a battery having a plurality of battery cells. Windings of the transformers are driven with an excitation waveform whereupon signals are responsively detected, which indicate a health of the battery. In one embodiment, excitation windings and sense windings are separately provided for the plurality of transformers such that the excitation waveform is applied to the excitation windings and the signals are detected on the sense windings. In one embodiment, the number of sense windings and/or excitation windings is varied to permit location of underperforming battery cells utilizing a peak voltage detector.

Davies, Francis J.

The Aeolus-Earth DWTS Heliophysics Mission

The Aeolus-Earth Mission (DWTS-Helio) is a recently selected NASA Heliophysics investigation that will apply the innovative Doppler Wind Temperature Sounder (DWTS) technique to the Space Atmosphere Interaction Region (SAIR) at ~105-180 km. The technique, invented by Gordley & Marshall (2011), applies the Doppler Scanning with Gas Filter (DSGF) technique using a cryo-cooled MWIR radiometer to view the limb of the atmosphere from LEO (orbital velocity creates the Doppler shifts required by the technique). For this implementation of DWTS, a Nitric Oxide (NO) low pressure gas cell is used. The limb of the atmosphere is observed from a spacecraft at orbital velocity, and as an observed air volume passes through the field of view, this velocity creates a set of Doppler-shifted images. These images are used to create Doppler Integrated Pass (DIP) signals, from which atmospheric temperature and wind profiles are extracted (it may be considered a converse of the successful in-flight calibration of gas cells used for the HALOE instrument). The technique is relative, removing the need for absolute radiances, and the signal-to-noise ratio for this technique is high, resulting in good measurement precision. Different gas cells can be used to create different altitude coverage and may be combined to measure a more continuous altitude range. For example, using a NO cell captures the lower atmosphere from 30-50km as well as the SAIR, while using the 13 isotopologue of CO2 would capture 50-120km. Due to the desired data volume as well as power and thermal considerations, this initial Aeolus-Earth flight will be more suited for a ‘hosted’ payload on an Orbital Maneuvering Vehicle platform instead of the ‘free-flyer’ option originally investigated. Lastly, the technique is sufficiently powerful that a two-channel system could produce full Mars atmosphere data not currently possible.

DWTS

Study of a Solar Sensor for use in Space Vehicle Orientation Control Systems

The solar sensor described herein may be used for a variety of space operations requiring solar orientation. The use of silicon solar cells as the sensing elements provides the sensor with sufficient capability to withstand the hazards of a space environment. A method of arranging the cells in a sensor consists simply of mounting them at a large angle to the base. The use of an opaque shield placed between the cells and perpendicular to the base enhances the small-angle sensitivity while adding slightly to the bulk of the sensor. The difference in illumination of these cells as the result of an oblique incidence of the light rays from the reference source causes an electrical error signal which, when used in a battery-bridge circuit, requires a minimum of electrical processing for use in a space-vehicle orientation control system. An error which could occur after prolonged operation of the sensor is that resulting from asymmetrical aging of opposite cells. This could be periodically corrected with a balance potentiometer. A more routine error in the sensor is that produced by reflected earth radiation. This error may be eliminated over a large portion of the operation time by restricting the field of view and, consequently, the capture capability. A more sophisticated method of eliminating this error is to use separate sensors, for capture and fine pointing, along with a switching device. An experimental model has been constructed and tested to yield an output sensitivity of 1.2 millivolts per second of arc with a load resistance of 1,000 ohms and a reference light source of approximately 1,200 foot-candles delivered at the sensor.

Spencer, Paul R.

Photoelectric system continuously monitors liquid level

Immersion probe presents a depth-sensitive optical transmission path between a light source and a photoelectric cell to continuously monitor the level of a transparent liquid in a tank. This system operates automatically, without moving parts, and provides output signals to a remote recorder.

Source record

NACA Stall-Warning Indicator

The stall-warning indicator employs a total-head tube located close to the wing surface in a region wherein local stalling occurs before the main portion of the wing stalls. The artificial production of a localized stalled region is accomplished by means of a sharp leading edge extending a few inches along the span. An abrupt drop in the total pressure relative to a static reference taken at some convenient point occurs at the stall in this region. Thin drop in total pressure caused the contraction of a pressure cell to which the total-head tube and the static orifice are connected and closed an electrical circuit that actuates a warning signal.

Thopmson, F L

Thermal Data-driven Model Reduction for Enhanced Battery Health Monitoring

Electric aviation faces a major challenge of avoiding potentially catastrophic consequences of the battery’s thermal runaway while keeping the weight of the battery low. Detection of early warning signals of battery failures requires accurate monitoring of the battery’s health throughout its lifespan. However, identifying the parameters of the battery from field data is notoriously difficult. We investigate this problem within the framework of modeling the temperature dynamics of a Li-ion cell during tests simulating loading in electric aircraft flights. It is found that the parameters of a higher-fidelity physics-based thermal model cannot be identified from the simulated flight data. To resolve this issue, we reduce the higher-fidelity thermal model to a model with fewer parameters. The resulting reduced-order model can predict temperature dynamics accurately and is identifiable throughout the cell’s lifespan which allows using the model’s parameters to monitor the state-of-health of the aging cell and detect anomalies in thermal behavior.

Li ion batteries