Predicting Li-Ion Battery Capacity Fade Using Early-Life Data and a Hybrid Data-Driven Gaussian Process-Bayesian Regression Approach

Accurately predicting Li-ion battery capacity trajectories using early-life data can dramatically improve battery-life understandings and be used to rapidly evaluate design/cost/performance trade-offs when developing new battery materials. Accurate early-life predictions enable researchers to quickly iterate over cell designs and material precursor properties without consistently cycling cells to failure. To this end, we present a toolbox that uses a combined Gaussian Process and Bayesian regression approach that capitalizes on signals other than just capacity (e.g., dQ/dV, voltage drops) to rapidly predict capacity-fade trajectories. The prediction tool uses Bayesian regression to fit functional forms, e.g., power law, sigmoids, etc., to predict capacity-fade dynamics. By fitting functional forms, the capacity fade can be interrogated at any point in the future, allowing for early cell-failure prediction. Additionally, Bayesian regression allows for accurate uncertainty estimates that account for cell-to-cell variability (aleatoric uncertainty) and the lack of observation data (epistemic uncertainty). By only using early cycle data to predict the capacity fade trajectory, uncertainty bounds at end-of-life can be extremely large. The large uncertainty bounds are further exacerbated because there is no systematic way to define the prior distribution of the functional forms' parameters. We improve our the predicted trajectory confidence interval of our predicted trajectory using two methods. First, we shows that a small amount of held-out cycling data is sufficientuse some train cells, that have been cycled to failure to derive information regarding the appropriate prior distributions for the functional forms' parameters of the functional form, effectively leading to data-driven priors.. We propose constructing the data-driven priors by first running a Bayesian regression starting with uninformed priors to generate intermediate cell-specific posterior parameter distributions. These posterior distributions are combined using a Ggaussian mixture model for each parameter to create the data-driven priors. These mixture models serve as the data-driven prior distributions for the parameters for. Second, we derive multiple features, e.g., C_dchg 0.5 DoD 0.5, log (|mean(dQ/dV_(w_3-w_0 ) (V)|), etc., from the train cellsheld-out cycling data, identify which the features are that best predicting capacity at early/mid-life cycles, and then create Ggaussian process regression models that are used for predicting capacity at early/mid-life cycles for the test cells (see blue dots with error bars in Fig 1b). Finally, these predicted data-points are used in addition to the actual early cycle data capacity fade to construct the Bayesian regression trajectory for the test cell s. Notably. We note that these two methods are complementary and can be combined with each other. We evaluate the performance of our proposed method on an testing open-source dataset from Iowa State University and Iowa Lakes Community College (ISU-ILCC). This dataset comprises of 251 nickel-manganese-cobalt/graphite Lithium-ion cells that are cycled under 63 different conditions. We compute the mean average percentage error (MAPE) and negative log predictive density (NLPD) to quantify the efficacy of our method. Our initial findings suggest that, when only few observations are available, for test cells, when using only Bayesian regression with uninformed priors, a power law functional provides the most accurate predictions. with very few data points. However, asHowever, a the number of data points increases, a twin sigmoidal function becomes more accurate as the number of observations further increases. We also find that using as little as 10% of the data set towards generating data-driven priors can lead to significant improvement in prediction accuracy when using early cycle data. Lastly, we found that augmenting early-cycle data with Gaussian process-predicted capacity data for Bayesian regression greatly improves the prediction accuracy. We will present a comprehensive comparison of our methods to other methods available in the literature and apply this method to additional battery datasets.

42 ENGINEERING↗

Understanding the role of water-soluble guar gum binder in reducing capacity fading and voltage decay of Li-rich cathode for Li-ion batteries

The practical application of high-capacity Li-rich cathode materials is hindered by capacity fading and voltage decay. The capacity fading and voltage decay could be effectively overcome by using water-soluble guar gum (GG) binder instead of traditional polyvinylidene fluoride (PVDF). However, the specific role of the GG binder is not clear yet, though the GG binder can significantly improve the electrochemical performance of Li-rich cathode. To understand the effect of GG binder on the morphology, microstructure of electrode and electrode/electrolyte interfaces, ex-situ scanning electron microscope (SEM), transmission electron microscope (TEM), X-ray adsorption near edge spectroscopy (XANES), in-situ electrochemical impedance spectroscopy (EIS) were applied to comparatively study the charge-discharge processes of Li-rich Li 1.2 Ni 0.2 Mn 0.6 O 2 cathode when using GG and PVDF as binders. The results indicate that the GG binder can prevent electrode crack and active material loss, ascribing to the strong mechanical adhesion of GG binder with active material particles and current collector. It has found that the GG binder can also induce the formation of a uniform layer on Li 1.2 Ni 0.2 Mn 0.6 O 2 particles’ surface. As a consequence, both the electrolyte decomposition and the electrode corrosion were significantly inhibited. The strong chelation between Mn 2+ and polar OH group restrain Mn ion dissolution, which contributes to surface structural transformation mitigation. Here, our study reveals the role of water-soluble GG binder in reducing capacity fading and voltage decay of Li-rich material and is of great importance in design functional binders for high-performance Li-rich electrodes.

25 ENERGY STORAGE↗

A Convolutional Neural Network Model for Battery Capacity Fade Curve Prediction using Early Life Data

Herein, early prediction of battery performance degradation trends can facilitate research of new materials and cell designs, rapid deployment of batteries in real-world applications, timely replacement of batteries in critical applications, and even the secondary use market. In this study, we design a convolutional neural network model to predict the entire battery capacity fade curve - a critical indicator of battery performance degradation - using first 100 cycles of data (~ three weeks of testing). We use the discharge voltage-capacity curves as input to the model and automate the feature extraction process through the convolutional layers of the network. Our approach can predict the per cycle capacity fade rate and rollover cycle (knee point) in the capacity fade curve, which indicate the onset of rapid capacity decay. On the publicly available graphite/LiFePO 4 battery dataset, optimized networks predict the capacity fade curves, rollover cycle, and end of life with 3.7% (worst-case), 19%, and 17% mean absolute percentage errors, respectively.

25 ENERGY STORAGE↗

Long-Term Stability of Ferri-/Ferrocyanide as an Electroactive Component for Redox Flow Battery Applications: On the Origin of Apparent Capacity Fade

We assess the suitability of potassium ferri-/ferrocyanide as an electroactive species for long-term utilization in aqueous organic redox flow batteries. A series of electrochemical and chemical characterization experiments was performed to distinguish between structural decomposition and apparent capacity fade of ferri-/ferrocyanide solutions used in the capacity-limiting side of a flow battery. Our results indicate that, in contrast with previous reports, no structural decomposition of ferri-/ferrocyanide occurs at tested pH values as high as 14 in the dark or in diffuse indoor light. Instead, an apparent capacity fade takes place due to a chemical reduction of ferricyanide to ferrocyanide, via chemical oxygen evolution reaction. We find that this parasitic process can be further exacerbated by carbon electrodes, with apparent capacity fade rates at pH 14 increasing with an increased ratio of carbon electrode surface area to ferricyanide in solution. Based on these results, we report a set of operating conditions that enables the long-duration cycling of alkaline ferri-/ferrocyanide electrolytes and demonstrate how apparent capacity fade rates can be engineered by the initial system setup. If protected from direct exposure to light, the structural stability of ferri-/ferrocyanide anions allows for their practical deployment as electroactive species in long duration energy storage applications.

25 ENERGY STORAGE↗

Decoupling the capacity fade contributions in polymer electrolyte-based high-voltage solid-state batteries

Polymer electrolyte (PE)-based solid-state batteries (PE-SSBs) made with high-voltage cathodes are known to suffer from severe capacity fade, stemming primarily from the poor oxidative stability of most PEs under high-voltage cycling conditions. PEs also suffer from greater ion-transport limitations compared to liquid or solid electrolytes. However, often, these limitations are collectively stated to be responsible for the observed capacity fade, and it is challenging to decouple the contributions of different factors. Herein, a tunable cell fabrication platform was developed to systematically investigate and decouple the two primary capacity fade drivers (cell impedance growth and kinetic limitations), while keeping the other cell parameters constant. Three PE types with distinct transport characteristics were compared. By utilizing a voltage profile analysis method, the contribution of the cell's internal impedance growth was quantitatively decoupled from the kinetic limitations stemming from the high concentration gradient in the polymer catholyte and slow charge transfer reactions. We demonstrate that the high interfacial impedance did not necessarily correlate with the high capacity fade rate. Kinetic limitations that are not reflected by impedance measurements can play a dominant role in causing cumulative capacity decay.

Ock, Ji-young [Oak Ridge National Laboratory (ORNL↗

The Role of Catholyte Modulation in Suppressing the Initial Capacity Fade of Zinc Electrolytic Manganese Dioxide Coin Cells

Despite its potential for zinc–manganese oxide batteries, electrolytic manganese dioxide (EMD) can experience capacity fade due to a deficiency in the Mn 2+ supply at the cathode electrolyte interphase (CEI) from side reactions, even in the presence of an electrolyte additive. In this work, electrolyte loading modulation at the cathode electrolyte interface (CEI) was correlated with Zn∥EMD cell capacity retention and cycling performance, as a proposed measure to curb the initial capacity fade observed in EMD. Initial galvanostatic charge/discharge cycling, with varied electrolyte loading, revealed severe capacity fade (from ~188 to 10 mAh g –1 for the highest loading of 200 μL) within the first 15 cycles. Such a decrease in cell capacity is correlated with the formation of a Mn 4+ deposit on the current collector and consequently, the Mn 2+ depletion at CEI, as was supported by elemental and Raman analyses. Interestingly, confinement of the electrolyte to the CEI at a lower (≤15 μL) electrolyte loading mitigated Mn 4+ side-deposition, maintaining the cell capacity at >80% over the first 15 cycles. Interfacial Mn supply/depletion could be monitored via voltammetric analysis based on changes of the Zn 2+ insertionreduction peak. Additional galvanostatic experiments corroborated the voltammetric interpretation and the proposed degradation pathway in the studied cell conditions. The outcomes of this work provide practical insight into coin-cell design and configuration strategies for developing Zn∥EMD batteries.

25 ENERGY STORAGE↗

Influence of crossover on capacity fade of symmetric redox flow cells

Volumetrically unbalanced compositionally symmetric cell cycling with potentiostatic (CV) or galvanostatic-with-potential-hold (CCCV) protocols is a rigorous technique for evaluating the calendar lifetime of reactants for redox flow batteries. Here, we evaluate the influence of reactant crossover through the membrane on symmetric cell cycling behavior. We tested symmetric cells of anthraquinone disulfonic acid (AQDS) with Nafion membranes of varied thickness and manufacture (NR211, NR212, N115, and N117, ranging 25–183 μm). Membranes were tested both as-received and pretreated with a common procedure of soaking in water at elevated temperature and then in dilute hydrogen peroxide. We found no significant difference in capacity fade rates of symmetric cells with any of the membranes as-received, indicating a negligible influence of crossover. However, we observed increased capacity fade with increased permeability through pretreated membranes. Supported by zero-dimensional modeling and operando UV-vis spectrophotometry, we propose a mechanism for net crossover in AQDS symmetric cells based on a higher time-averaged concentration of quinhydrone dimers in the non-capacity limiting side (NCLS) compared to the capacity limiting side (CLS), driving net crossover of AQDS reactants out of the CLS. Further, we illustrate other hypothetical scenarios of net crossover using the zero-dimensional model. Overall, many membrane–electrolyte systems used in symmetric cell studies have sufficiently low crossover flux as to avoid the influence of crossover on capacity fade, but under conditions of higher crossover flux, complex interactions of crossover and chemical reactions may result in diverse capacity fade trajectories, the mechanisms of which may be untangled with operando characterization and modeling.

25 ENERGY STORAGE↗

Revisiting the capacity-fading mechanism of P2-type sodium layered oxide cathode materials during high-voltage cycling

We report P2-type sodium layered oxide cathode (Na 2/3 Ni 1/3 Mn 2/3 O 2 , P2-NNMO) has attracted great attention as a promising cathode material for sodium ion batteries because of its high specific capacity. However, this material suffers from a rapid capacity fade during high-voltage cycling. Several mechanisms have been proposed to explain the capacity fade, including intragranular fracture caused by the P2-O2 phase transion, surface structural change, and irreversible lattice oxygen release. Here we systematically investigated the morphological, structural, and chemical changes of P2-NNMO during high-voltage cycling using a variety of characterization techniques. It was found that the lattice distortion and crystal-plane buckling induced by the P2-O2 phase transition slowed down the Na-ion transport in the bulk and hindered the extraction of the Na ions. The sluggish kinetics was the main reason in reducing the accessible capacity while other interfacial degradation mechanisms played minor roles. Our results not only enabled a more complete understanding of the capacity-fading mechanism of P2-NNMO but also revealed the underlying correlations between lattice doping and the moderately improved cycle performance.

25 ENERGY STORAGE↗

The Impact of Lithium Anode Interface on Capacity Fade in Polymer Electrolyte-Based Solid-State Batteries

This study investigates the Li stripping-plating morphology and failure mechanisms in full cells consisting of a solid polymer electrolyte (SPE) with two commercial Li anodes: Li chip and Li foil. The primary identified failure mechanism of the SPE cell is capacity fade, regardless of the Li manufacturer. While the cathode’s role in capacity fade is evident, the Li anode significantly influences cycling performance, with Li foil cells cycling 50% longer than Li chip cells, a statistical difference. Further, post-mortem scanning electron microscopy and X-ray photoelectron spectroscopy results attribute the Li chip’s faster capacity fade to a loss of contact and continuous growth of the solid electrolyte interphase (SEI). Conversely, Li foil maintains consistent contact with the solid polymer, displaying a thin and stable SEI. Additionally, failure mechanisms between a gel electrolyte in previous work and the dry SPE are compared.

25 ENERGY STORAGE↗

Probing Sources of Capacity Fade in LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622): An Operando XRD Study of Li/NMC622 Batteries during Extended Cycling

LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) is one of the most promising Li-ion battery cathodes as it delivers high capacity at high potentials. However high potentials also lead to decreases in capacity retention where the disintegration of the secondary particles has been implicated as a major driving force of this capacity fade. This has been attributed to anisotropic lattice changes and increased microstrain during cycling. To probe how these factors affect capacity fade, Li/NMC622 batteries were cycled from 3-4.3 or 4.7 V and probed with operando X-ray diffraction over the 1st, 2nd, and 101st cycles. Further characterization with scanning electron microscopy, and inductively coupled plasmaoptical emission spectroscopy was also performed. The use of operando XRD over many cycles allowed for the collection of detailed structural information in real time over a time frame in which fading can be observed. During the first two cycles, the cells charged to 4.7 V exhibit increased anisotropic lattice changes as compared to the cells charged to 4.3 V. Upon the 101st cycle, when significant fade has been observed, the cells charged to 4.3 and 4.7 V show identical lattice changes to one another, while the 4.7 V charge limit induces more microstrain. This shows that elevated microstrain at high charge limits is a major driver for particle disintegration in NMC622 cathodes. This study provides important insights into the mechanisms of particle disintegration and capacity fade in NMC/Li-ion batteries, which will enable the design of NMC electrodes that deliver both higher capacities and exhibit better capacity retention.

25 ENERGY STORAGE↗

Unraveling capacity fading in lithium-ion batteries using advanced cyclic tests: A real-world approach

Battery lifespan estimation is essential for effective battery management systems, aiding users and manufacturers in strategic planning. However, accurately estimating battery capacity is complex, owing to diverse capacity fading phenomena tied to factors such as temperature, charge-discharge rate, and rest period duration. In this work, we present an innovative approach that integrates real-world driving behaviors into cyclic testing. Unlike conventional methods that lack rest periods and involve fixed charge-discharge rates, our approach involves 1000 unique test cycles tailored to specific objectives and applications, capturing the nuanced effects of temperature, charge-discharge rate, and rest duration on capacity fading. This yields comprehensive insights into cell-level battery degradation, unveiling growth patterns of the solid electrolyte interface (SEI) layer and lithium plating, influenced by cyclic test parameters. Here, the results yield critical empirical relations for evaluating capacity fading under specific testing conditions.

25 ENERGY STORAGE↗

Understanding capacity fade in organic redox-flow batteries by combining spectroscopy with statistical inference techniques

Organic redox-active molecules are attractive as redox-flow battery (RFB) reactants because of their low anticipated costs and widely tunable properties. Unfortunately, many lab-scale flow cells experience rapid material degradation (from chemical and electrochemical decay mechanisms) and capacity fade during cycling (>0.1%/day) hindering their commercial deployment. In this work, we combine ultraviolet-visible spectrophotometry and statistical inference techniques to elucidate the Michael attack decay mechanism for 4,5-dihydroxy-1,3-benzenedisulfonic acid (BQDS), a once-promising positive electrolyte reactant for aqueous organic redox-flow batteries. We use Bayesian inference and multivariate curve resolution on the spectroscopic data to derive uncertainty-quantified reaction orders and rates for Michael attack, estimate the spectra of intermediate species and establish a quantitative connection between molecular decay and capacity fade. Our work illustrates the promise of using statistical inference to elucidate chemical and electrochemical mechanisms of capacity fade in organic redox-flow battery together with uncertainty quantification, in flow cell-based electrochemical systems.

25 ENERGY STORAGE↗

Impact of Charge Voltage on Factors Influencing Capacity Fade in Layered NMC622: Multimodal X-ray and Electrochemical Characterization

Ni-rich NMC is an attractive Li-ion battery cathode due to its combination of energy density, thermal stability, and reversibility. While higher delivered energy density can be achieved with a more positive charge voltage limit, this approach compromises sustained reversibility. Improved understanding of the local and bulk structural transformations as a function of charge voltage, and their associated impacts on capacity fade are critically needed. Through simultaneous operando synchrotron X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) of cells cycled at 3–4.3 or 3–4.7 V, this study presents an in-depth investigation into the effects of voltage window on local coordination, bulk structure, and oxidation state. These measurements are complemented by ex situ X-ray fluorescence (XRF) mapping and scanning electrochemical microscopy mapping (SECM) of the negative electrode, X-ray photoelectron spectroscopy (XPS) of the positive electrode, and cell level electrochemical impedance spectroscopy (EIS). Initially, cycling between 3 and 4.7 V leads to greater delivered capacity due to greater lithium extraction, accompanied by increased structural distortion, moderately higher Ni oxidation, and substantially higher Co oxidation. Continued cycling at this high voltage results in suppressed Ni and Co redox, greater structural distortion, increased levels of transition metal dissolution, higher cell impedance, and 3× greater capacity fade.

capacity fading mechanisms↗

A High Potential, Low Capacity Fade Rate Iron Complex Posolyte for Aqueous Organic Flow Batteries

An iron complex, tris(4,4'-bis(hydroxymethyl)-2,2'-bipyridine) iron dichloride is reported, which operates at near-neutral pH with a redox potential of 0.985 V versus SHE. This high potential compound is employed in the posolyte of an aqueous flow battery, paired with bis(3-trimethylammonio)propyl viologen tetrachloride in the negolyte, exhibiting an open-circuit voltage of 1.3 V at near-neutral pH. It demonstrates excellent cycling performance with a low temporal capacity fade rate of 0.07% per day over 35 days of cycling. The extended cycling lifetime is the result of low permeability and improved structural stability of the newly developed iron complex compared to that of the iron tris(bipyridine) complex. The combination of high redox potential and low capacity fade rate compares favorably with those of all previously demonstrated organic and organometallic aqueous posolytes. Extensive investigation into the possible degradation mechanisms, including post-mortem chemical and electrochemical analyses, indicates that stepwise ligand dissociations of the iron complex are responsible for the reported capacity loss during cell cycling. Further, this investigation provides unprecedented insight to guide further improvements of such metalorganic compounds for energy storage and conversion applications.

25 ENERGY STORAGE↗

Evaluating capacity fade in dual insertion batteries using potential and temperature measurements

Methods and systems are described of managing a battery system. The battery system including at least one battery cell and one or more sensors configured to measure a temperature of the at least one battery cell. The method includes receiving a measurement of the temperature of the at least one battery cell, estimating an open circuit potential of the at least one battery cell, estimating a capacity fade of the at least one battery cell based on the open circuit potential of the at least one battery cell and a ratio of a change in the open circuit potential relative to a change in the temperature of the at least one battery cell, and regulating at least one of charging or discharging of the at least one battery cell based on the estimation of the capacity fade.

Christensen, John F.↗

Critical Evaluation of Potentiostatic Holds as Accelerated Predictors of Capacity Fade during Calendar Aging

Li-ion batteries will lose both capacity and power over time due to calendar aging caused by slow parasitic processes that consume Li + ions. Studying and mitigating these processes is traditionally an equally slow venture, which is especially taxing for the validation of new active materials and electrolyte additives. Here, we evaluate whether potentiostatic holds can be used to accelerate the diagnosis of Li + loss during calendar aging. The technique is based on the idea that, under the right conditions, the current measured as the cell voltage is held constant can be correlated with the instantaneous rate of side reactions. Thus, in principle, these measurements could capture the rate of capacity fade in real time . In practice, we show that this method is incapable of quantitatively forecasting calendar aging trends. Instead, our study demonstrates that potentiostatic holds can be applied for initial qualitative screening of systems that exhibit promising long-term stability, which can be useful to shrink the parameter space for calendar aging studies. By facilitating the identification of improved formulations, this approach can help accelerate innovation in the battery industry.

25 ENERGY STORAGE↗

Capacity Fade of Graphite/NMC811: Influence of Particle Morphology, Electrolyte, and Charge Voltage

LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) is an important Li-ion battery cathode material; however, there is a tradeoff between delivered capacity and capacity retention. As the charge potential increases the capacity rises but at the expense of capacity retention. The decrease in capacity retention has been ascribed to several factors including particle cracking, surface reconstruction, transition metal dissolution, and electrolyte reactivity. The present study compares 4.1 and 4.3 V charging limits in commercially relevant graphite/NMC811 pouch cells for single crystal (SC) and polycrystalline (PC) NMC811 with ethylene carbonate (EC)-containing or EC-free electrolytes. The electrochemistry is rationalized through analysis of electrochemical impedance spectroscopy, positive electrode X-ray photoelectron spectroscopy, soft X-ray absorption spectroscopy, X-ray diffraction, and negative electrode mapping by X-ray fluorescence. Graphite/SC-NMC811 cells show high-capacity retention at 4.1 V but exhibit degradation at 4.3 V charging potentials. The EC-free electrolyte cells led to higher capacity fade, especially when charged to 4.3 V. Cathode dissolution and deposition on the negative electrode from PC-NMC811 cells was higher than for samples from SC-NMC811 cells. This study reveals the impact of material type, charge voltage, and electrolyte composition on the reactions at the positive electrode, their influence on the negative electrode, and evolution with cycle number.