Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Gas-Gap Calorimeter Sizing and Rating Tools for Heat Pipe Experimentation

Effective gas-gap calorimeter sizing and rating tools are required to design calorimeters that enable well-defined operating conditions, high cooling powers, and accurate calorimetry. The present report describes two tools utilizing Microsoft Excel and MathWorks MATLAB that enable the sizing and rating of gas-gap calorimeters with a He-Ar binary gas mixture in the gap. The Excel tools are two easy-to-use spreadsheets for calculating heat pipe operating temperature or He-Ar mole fractions given the required inputs. The MATLAB tool includes similar models with more robust solution algorithms along with sub-options for full-vacuum, static gas-gap, and forced circulation in the gas-gap. The accuracy of the developed tools were demonstrated by comparing with existing work in literature. The MATLAB tool was used for a parametric study to determine the gas-gap thickness, coolant gap thickness, coolant flow rate, and coolant inlet temperatures for the testing of a 3/4 in outer diameter heat pipe up to powers of 10 kW and temperatures of 1,000°C. The effects of heat pipe and calorimeter inner shell surface emissivities were investigated, considering the inability to control or accurately measure surface emissivities in most applications. It was found that controlling the He-Ar mole fractions provides a wide operating range for gas-gap thicknesses around ~ 0.042--0.090 in (~ 1.07--2.29 mm) for a surface emissivity range of 0.4--0.8, since conduction heat transfer is a significant fraction of the heat transfer across the gas-gap. In addition, it was found that turbulent flow in the coolant gap is needed at high input powers to prevent shell temperatures from approaching the boiling temperature of the water coolant. The parametric study resulted in choosing stainless steel tubes with an outer diameter and thickness of 1 x 0.065 in as the inner shell, and a 1-1/2 x 0.156 in as the outer shell of the calorimeter. Overall, this report presents the necessary information for the sizing and rating of gas-gap calorimeters with He-Ar mixtures for the testing of high-temperature heat pipes (~ 500--1,000°C).

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

AI-assisted object condensation clustering for calorimeter shower reconstruction at CLAS12

Several nuclear physics studies using the CLAS12 detector rely on the accurate reconstruction of neutrons and photons from its forward angle calorimeter system. These studies often place restrictive cuts when measuring neutral particles due to an overabundance of false clusters created by the existing calorimeter reconstruction software. In this work, we present a new AI approach to clustering CLAS12 calorimeter hits based on the object condensation framework. The model learns a latent representation of the full detector topology using GravNet layers, serving as the positional encoding for an event’s calorimeter hits which are processed by a Transformer encoder. This unique structure allows the model to contextualize local and long range information, improving its performance. Evaluated on one million simulated $e^-$ $+$ $p$ collision events, our method significantly improves cluster trustworthiness: the fraction of reliable neutron clusters, increasing from 8.88% to 30.73%, and photon clusters, increasing from 51.07% to 64.73%. In conclusion, our study also marks the first application of AI clustering techniques for hodoscopic detectors, showing potential for usage in many other experiments.

Calorimeters

On the resolution of dual readout calorimeters

Dual readout calorimeters allow state-of-the-art resolutions for hadronic energy measurements. Their various incarnations are leading candidates for the calorimeter systems for future colliders. In this paper, we present a simple formula for the resolution of a dual readout calorimeter, which we verify with a toy simulation and with full simulation results. This formula can help those new to dual readout calorimetry understand its strengths and limitations. The paper also highlights that the dual readout correction works not just to compensate for binding energy loss, but also for energies escaping the calorimeter or clustering algorithm. Formulae are also presented for approximate resolutions and energy scales in terms of different sources of response.

Calorimeters

Evaluation of the response to electrons and pions in the scintillating fiber and lead calorimeter for the future electron-ion collider

The performance of the Baby Barrel Electromagnetic Calorimeter (Baby BCAL) — a small-scale lead-scintillating-fiber (Pb/ScFi) prototype of the GlueX Barrel Electromagnetic Calorimeter (BCAL) — was tested in a dedicated beam campaign at the Fermilab Test Beam Facility (FTBF). This study provides a benchmark for the Pb/ScFi component of the future Barrel Imaging Calorimeter (BIC) in the ePIC detector at the Electron-Ion Collider (EIC). The detector response to electrons and pions was studied at beam energies between 4 and 10 GeV, extending previous GlueX tests to a higher energy regime. The calibrated detector exhibits good linearity within uncertainties, and its electron energy resolution meets EIC requirements. The data further constrain the constant term in the energy resolution to below 1.9%, improving upon previous constraints at lower energies. Simulations reproduce key features of the electron and pion data within the limitations of the collected dataset and the FTBF test environment. Electron-pion separation in the test beam setup was analyzed using multiple methods, incorporating varying degrees of beam-related effects. The inclusion of longitudinal shower profile information enhanced the separation performance, underscoring its relevance for the full-scale BIC in ePIC. These results provide essential benchmarks for the Pb/ScFi section of the future BIC, validating detector simulations and guiding optimization strategies for electron-pion discrimination.

47 OTHER INSTRUMENTATION

CaloChallenge 2022: a community challenge for fast calorimeter simulation

Here, we present the results of the ‘Fast Calorimeter Simulation Challenge 2022’—the CaloChallenge. We study state-of-the-art generative models on four calorimeter shower datasets of increasing dimensionality, ranging from a few hundred voxels to a few tens of thousand voxels. The 31 individual submissions span a wide range of current popular generative architectures, including variational autoencoders (VAEs), generative adversarial networks (GANs), normalizing flows, diffusion models, and models based on conditional flow matching. We compare all submissions in terms of quality of generated calorimeter showers, as well as shower generation time and model size. To assess the quality we use a broad range of different metrics including differences in one-dimensional histograms of observables, KPD/FPD scores, AUCs of binary classifiers, and the log-posterior of a multiclass classifier. The results of the CaloChallenge provide the most complete and comprehensive survey of cutting-edge approaches to calorimeter fast simulation to date. In addition, our work provides a uniquely detailed perspective on the important problem of how to evaluate generative models. As such, the results presented here should be applicable for other domains that use generative AI and require fast and faithful generation of samples in a large phase space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Operation and performance of the ATLAS tile calorimeter in LHC Run 2

The ATLAS tile calorimeter (TileCal) is the hadronic sampling calorimeter covering the central region of the ATLAS detector at the Large Hadron Collider (LHC). This paper gives an overview of the calorimeter’s operation and performance during the years 2015–2018 (Run 2). In this period, ATLAS collected proton–proton collision data at a centre-of-mass energy of 13 TeV and the TileCal was 99.65% efficient for data-taking. The signal reconstruction, the calibration procedures, and the detector operational status are presented. The performance of two ATLAS trigger systems making use of TileCal information, the minimum-bias trigger scintillators and the tile muon trigger, is discussed. Studies of radiation effects allow the degradation of the output signals at the end of the LHC and HL-LHC operations to be estimated. Finally, the TileCal response to isolated muons, hadrons and jets from proton–proton collisions is presented. The energy and time calibration methods performed excellently, resulting in good stability and uniformity of the calorimeter response during Run 2. The setting of the energy scale was performed with an uncertainty of 2%. The results demonstrate that the performance is in accordance with specifications defined in the Technical Design Report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Calorimeter calibration and performance for the Mu2e experiment

The Mu2e experiment at Fermilab will search for the charged lepton flavour-violating conversion of a muon into an electron, aiming to reach a sensitivity of $R_{\mu e} \sim 10^{-17}$, an improvement of four orders of magnitude over previous limits. To reach this goal, Mu2e will use an intense pulsed muon beam and a detector system composed of a high-precision straw tube tracker and a pure CsI crystal calorimeter. The calorimeter plays a crucial role in the experiment, as it provides particle identification capabilities that are necessary for background suppression. To perform its tasks, the detector must achieve an energy resolution better than 10% and a timing resolution below 500 ps for 100 MeV electrons. Cosmic-ray data and laser pulses are used to equalize the response of each channel, to calibrate the energy scale and to monitor the system's stability over time. This poster reports on the calibration and analysis techniques developed to ensure that the calorimeter requirements for precise energy and time measurements are met. Results for the calorimeter performance obtained during the commissioning phase will be discussed, and an overview of the current status in the Mu2e experimental hall will be presented.

Salamino, Sabrina [Frascati]

Design of a Level-1 Long-Lived Particle Trigger in the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 to introduce depth segmentation and online timing measurements, expanding the physics capabilities. In particular, the augmentation of the calorimeter information at the hardware trigger level enables quick identification and recording of long-lived particle decays using lower thresholds on energy-based event quantities. The depth segmentation and online timing capabilities are utilized in novel HCAL-based hardware-level triggers to identify displaced and delayed long-lived particles (LLPs), either decaying inside the calorimeter volume or arriving at a delayed time. This increases the sensitivity to LLP decays occurring up to almost 6 m from the collision point. This two-pronged calorimeter trigger approach leverages the new capabilities of the CMS HCAL to expand the phase space accessible in ongoing LLP searches. These triggers were deployed for Run 3 of the LHC, beginning data-taking in 2022, and we review the trigger implementation and calibration.

Kopp, Gillian Baron [Princeton University, NJ (Uni

Status of the Mu2e calorimeter readout electronics

The Mu2e experiment [1] at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photomultipliers and fast front-end and digitization electronics. The front-end electronics consists of two discrete readout circuits (AMP-HV) for each crystal. These provide the amplification, shaping stage and linear regulation of the SiPM bias voltage and monitoring. The SiPM and front-end control electronics is implemented in a battery of mezzanine boards each equipped with an ARM processor that controls a group of 20 Amp-HV circuits distributing the low voltage and the high-voltage. The electronic is hosted in crates located on the external surface of calorimeter disks. The crates also host the waveform digitizer board (DIRAC) that performs digitization of the front end signals and transmit the digitized data to the Mu2e DAQ. Calorimeter electronic is hosted inside the cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. The system design and quality assurance procedures will be reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Performance measurements of the electromagnetic calorimeter and readout electronics system for the DarkQuest experiment

Here, this paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the SeaQuest/SpinQuest spectrometer has been proposed to broaden the experiment’s dark sector search program, an upgrade known as DarkQuest. The calorimeter and electronics system were subjected to testing and calibration at the Fermilab Test Beam Facility. Detailed studies of the energy response and resolution, as well as particle identification capabilities, were performed. The background rate in the actual experimental environment was also examined. The system is found to be well-suited for a dark sector search program on the Fermilab 120 GeV proton beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

The BigBite Calorimeter for the Super Bigbite Spectrometer Program at Jefferson Lab

Here, we report features of the design, construction, installation, and performance of the BigBite Calorimeter (BBCal), a lead-glass electromagnetic calorimeter constructed as part of the BigBite Spectrometer (BBS), which served as the electron arm for the Super Bigbite Spectrometer (SBS) program of high-precision neutron electromagnetic form factor measurements in Hall A at Jefferson Lab. As a total-absorption calorimeter, BBCal provided the primary electron trigger for BBS, detecting quasi-elastically scattered electrons in the 1–4 GeV energy range with an energy resolution of approximately 6.2%, position resolution of 1.2 cm, and timing resolution of 0.5 ns.

BBCal

Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter

A novel method to reconstruct the energy of hadronic showersin the CMS High Granularity Calorimeter (HGCAL) is presented. TheHGCAL is a sampling calorimeter with very fine transverse andlongitudinal granularity. The active media are silicon sensors andscintillator tiles readout by SiPMs and the absorbers are acombination of lead and Cu/CuW in the electromagnetic section, andsteel in the hadronic section. The shower reconstruction method isbased on graph neural networks and it makes use of a dynamicreduction network architecture. It is shown that the algorithm isable to capture and mitigate the main effects that normally hinderthe reconstruction of hadronic showers using classicalreconstruction methods, by compensating for fluctuations in themultiplicity, energy, and spatial distributions of the shower'sconstituents. The performance of the algorithm is evaluated usingtest beam data collected in 2018 prototype of the CMS HGCALaccompanied by a section of the CALICE AHCAL prototype. Thecapability of the method to mitigate the impact of energy leakagefrom the calorimeter is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Time Alignment of the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 (2022-2025) to introduce depth segmentation and online timing measurements. With increased segmentation and readout channels, the HCAL provides new timing capabilities for jets and hadronic tau decays with nearly 4π coverage and sensitivity to highly displaced decays within the calorimeter volume. Recent HCAL timing scans provide a valuable look at artificially delayed jets in collision data and are crucial to improving the detector’s performance. Online timing is utilized for detector alignment based on positioning the pulse rising edge, achieving an alignment accuracy of 0.5 ns, considerably higher than previous energy-weighting based approaches. Using precision arrival time measurements, significant advances have been made in understanding the propagation of hadronic showers throughout the calorimeter.

Kopp, Gillian [Princeton Univ., NJ (United States)

Lead tungstate calorimeter of the Jefferson Lab Eta Factory experiment

A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO 4 scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The highgranularity, high-resolution calorimeter is required by the JLab Eta Factory experiment, whose main physics goal is to study rare decays of eta mesons. The ECAL replaced the inner part of the forward lead glass calorimeter of the GlueX detector. Signals from the detector will be digitized using twelve-bit flash analog-to-digital converters operated at a sampling rate of 250 MHz. The ECAL is integrated into the trigger system of the GlueX detector using electronics modules designed at JLab. The ECAL is currently at the commissioning stage and should be ready for the physics run in January 2025. We will give an overview of the JEF experiment, the design and construction of the ECAL, and the integration of the detector and its infrastructure into the Hall D experimental setup.

Somov, Alexander [Thomas Jefferson National Accele

Performance of the CMS electromagnetic calorimeter in pp collisions at √$_{s}$ = 13 TeV

The operation and performance of the Compact Muon Solenoid(CMS) electromagnetic calorimeter (ECAL) are presented, based ondata collected in pp collisions at√$_{s}$ =13 TeV at the CERN LHC, in the years from 2015 to 2018(LHC Run 2), corresponding to an integrated luminosity of151 fb$^{-1}$. The CMS ECAL is a scintillating lead-tungstatecrystal calorimeter, with a silicon strip preshower detector in theforward region that provides precise measurements of the energy andthe time-of-arrival of electrons and photons. The successfuloperation of the ECAL is crucial for a broad range of physics goals,ranging from observing the Higgs boson and measuring its properties,to other standard model measurements and searches for newphenomena. Precise calibration, alignment, and monitoring of theECAL response are important ingredients to achieve these goals. Toface the challenges posed by the higher luminosity, whichcharacterized the operation of the LHC in Run 2, the proceduresestablished during the 2011–2012 run of the LHC have been revisitedand new methods have been developed for the energy measurement andfor the ECAL calibration. The energy resolution of the calorimeter,for electrons from Z boson decays reaching theECAL without significant loss of energy by bremsstrahlung, wasbetter than 1.8%, 3.0%, and 4.5% in the |η| intervals[0.0,0.8], [0.8,1.5], [1.5, 2.5], respectively. This resultingperformance is similar to that achieved during Run 1 in 2011–2012,in spite of the more severe running conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Online and Offline Data Quality Monitoring for the Mu2e Calorimeter

This thesis presents the design, implementation, and validation of a calorimeter Data Quality Monitoring (DQM) toolchain for the Mu2e experiment at Fermilab. Mu2e searches for charged lepton flavor violation via coherent muon-to-electron conversion in the field of an aluminum nucleus, $\mu^- Al \rightarrow e^-Al$, a process whose observation would constitute clear evidence of physics beyond the Standard Model. Achieving target sensitivity requires stringent control of detector performance and data integrity during acquisition, as subtle issues in readout configuration, data formatting, or electronics behavior can compromise reconstruction and bias downstream analyzes. To address these challenges, this work develops a multi-layer DQM approach spanning both raw data validation and reconstructed digi-level diagnostics. At the low level, a fragment analysis component performs word- and bit-field decoding of calorimeter readout blocks, enabling sanity checks of the expected structure and producing detailed error and integrity statistics useful for commissioning and troubleshooting. At the digi level, the CaloDigiDQM analyzer is implemented within the art framework and transforms each CaloDigiCollection into a structured hierarchy of ROOT histograms designed for fast drill-down diagnostics. The module generates coherent monitoring views at global, disk, board, and channel granularity, including occupancy, waveform-derived features (baseline, RMS, peak amplitude and position), and left-right sensor consistency metrics. Detector-aware channel-to-electronics mapping is performed through the conditions system (CaloDAQMap), ensuring that diagnostics remain aligned with hardware identifiers used in operations. For end-to-end testing without reliance on live DAQ data, a synthetic CaloDigi producer is developed to generate realistic waveforms with controlled noise and pulse shapes. The resulting system supports both offline ROOT-file production and online operation, including optional histogram streaming through otsdaq via ots::HistoSender. This toolchain provides a practical and scalable foundation for calorimeter commissioning and stable data collection, enabling early detection of anomalies and reducing operational risk for Mu2e.

Vakulenko, Mark [Drew U.] (ORCID:0009000276197818)