Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cabinet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

LINAC Electrical Cabinets - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, pipe lines, circuits, conduits. In addition, high voltage and flowing fluids are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model will be developed for each cabinet and a Finite Element Analysis (FEA) will be performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

LINAC Electrical Cabinet - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PFN (pulse-forming network) Module, PFN Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, circuits, and conduits. In addition, high voltage and low conductivity water (LCW) piping are also present within the cabinets. Occasionally, Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model was developed for each cabinet and a Finite Element Analysis (FEA) was performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

LINAC Electrical Cabinets - Structural Analysis

Along LINAC s downstream path is a floor containing various cabinets above the LINAC. Of the dozens of cabinets are 4 specific cabinet types: PNF Modulator, PNF Power Supply, Water Skid, and Marx. Each of these cabinets may contain some of the various contents that include electronics, wiring, pipelines, circuits, and conduits. Lab Technicians perform maintenance and inspections of the cabinets and need to access every part, including the top section that is subject to the weight of the technician standing on top. To ensure the cabinet is structurally safe, a CAD model will be developed for each cabinet and a Finite Element Analysis (FEA) will be performed on each cabinet to confirm it is safe to stand on.

Blas, Efren↗

Building America Top Innovations 2014 Profile: HVAC Cabinet Air Leakage Test Method

This 2014 Top Innovation profile describes Building America-funded research by teams and national laboratories that resulted in the development of an ASHRAE standard and a standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets and has spurred equipment manufacturers to tighten the cabinets they use for residential HVAC systems.

air handler↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Installation of Ramps and Utility Cabinet at TA-18-1 Slotin Building (Historic Building Report No. 395)

The information below is presented in response to requests for additional information that resulted from a phone conference on November 12, 2020 between Harvey Kaplan of the New Mexico State Historic Preservation Office, DOE NNSA Los Alamos Field Office Manhattan Project National Historical Park Representative, Vicki Loucks, LANL Program Manager for Manhattan Project National Historical Park, Cheryl Abeyta, and LANL Historic Buildings Program Staff, Jeremy Brunette and J.T. Stark. The DOE NNSA Field Office (Field Office) initiated the call to propose additional work be performed to a previously reviewed project, “Restoration of TA-18-0001 (Slotin Building)” (LA-UR-19-26609) (HPD Log # 111110). Of the six actions discussed on the call, which included (1) exterior paint color, (2) entrance ramps, (3) non-period metal siding removal, (4) interior floor finish, (5) reopening secondary entrance door, and (6) addition of utility cabinet with period doors, additional information for two of the actions was requested for further review. The two actions, the construction of entrance ramps and installation of a utility cabinet are addressed in detail.

42 ENGINEERING↗

Laboratory biological safety cabinet (BSC) explosion

Scientists at universities across Iraq are actively working to report actual incidents and accidents occurring in their laboratories in order to raise awareness and encourage openness, leading to widespread adoption of robust Chemical Safety and Security (CSS) practices. This manuscript is the first in a series of five case studies describing laboratory incidents and accidents in Iraqi university laboratories in order to share lessons learned and minimize the possibility of similar incidents in the future. In this study, we describe a serious event that resulted in a postgraduate student sustaining serious injuries when the biological safety cabinet (BSC) she was using exploded. Of particular note, the paper highlights how a combination of failures and deficiencies at many levels within an organization and its technical community (rather than a single piece of faulty equipment or the careless behavior of one person) can lead to a dangerous, potentially life-threatening incident. By openly sharing what happened along with the lessons learned from the accident, we hope to minimize the possibility of another researcher being injured in a similar incident in the future.

biological safety cabinet↗

Compact X-band split electron linac for cabinet-size small-sample irradiators

Many small-scale industrial radiation facilities rely on hazardous radioisotope-based gamma ray irradiators, which are being gradually replaced by alternative technologies, such as particle accelerators. RadiaBeam has developed a compact, cabinet-size, 3 MeV electron-linac-based irradiator to match the penetration of Co-60 and provide high irradiation throughput. Here the linac utilizes X-band RF power to reduce size, employs an innovative split-linac approach to lower costs, and features a novel X-ray conversion target geometry that spreads the beam out across the target, providing a low dose uniformity ratio. In this paper, we discuss the accelerator design, fabrication, and test results.

43 PARTICLE ACCELERATORS↗

Meeting Summary of Kitchen Cabinet on Financial Due Diligence to Reduce Proliferation Risks

The U.S. Department of Energy’s Pacific Northwest National Laboratory convened the Kitchen Cabinet (KC) to facilitate a candid discussion about the role of financial institutions (FIs) in antiproliferation efforts to reduce nuclear proliferation risks by identifying suspicious business transactions and exports when making lending or insurance decisions. The meeting brought together a group of export control specialists, largely representatives from the Nuclear Suppliers Group (NSG) Participating Governments (PGs) and finance experts representing banks and insurance companies. By assembling a KC of experts, the group could understand what suspicious transactions look like from each other’s perspectives and better inform each of their operations. The goal was to develop red flags FIs could use to identify suspicious proliferation-related transactions and to help governments gain a clearer picture of proliferation using financial information.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Additive Manufacturing of Tooling for Refrigeration Cabinet Foaming Processes

The primary objective of this project was to leverage the Big Area Additive Manufacturing (BAAM) process and materials into a long term, quick change tooling concept to drastically reduce product lead and development timelines and costs. Current refrigeration foam molds are complicated to manufacture involving casting several aluminum parts in an approximate shape, machining components of the molds and post fitting and shimming of the parts in an articulated fixture. The total process timeline can take over 6 months. The foaming process is slower than required for production, therefore multiple fixtures, 10 to 27, are required per refrigerator model. Molds are particular to a specific product configuration making mixed model assembly challenging for sequencing, mold changes or auto changeover features. The initial goal was to create a tool leveraging the ORNL materials and additive process to build a tool in 4 to 6 weeks or less. A secondary goal was to create common fixture cores and provide lightweight fixture sections that could be revised in a very short time to increase equipment flexibility reduce lead times, lower the barriers to first production trials, and reduce tooling costs.

3d Printing↗

Improving the energy efficiency of a refrigerator-freezer through the use of a novel cabinet/door liner based on polylactide biopolymer

This paper presents the energy savings potential of a newly developed liner applied on the foam insulation used in refrigerator and freezer cabinets, compared with using a more commonly used liner made from high-impact polystyrene. The new polylactic acid polymer liner is made from renewable feedstock such as carbon found in plant sugars. The energy use over the life of refrigerator and freezer is calculated using the Energy-Efficient Refrigerator Analysis program developed by the United States Department of Energy to estimate the energy savings potential of various technology option upgrades (cabinet and refrigeration system) for rulemaking purposes. The simulation results show that energy savings from implementing the Ingeo liner range from 818 to 1395tkWh (7.3–12.5% of total energy use) over a 15-year period. In addition to the energy savings, the slower increase in the thermal conductivity of the insulation could allow the compressor to run fewer hours per year compared with a case in which the foam thermal conductivity increases rapidly. This change could increase the life of the compressor and the refrigerators and freezers. As a result, this study does not attempt to quantify the impact of slower foam aging on the compressor life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of risk mitigation guidance for sensor placement inside mechanically ventilated enclosures – Phase 1

Guidance on Sensor Placement was identified as the top research priority for hydrogen sensors at the 2018 HySafe Research Priority Workshop on hydrogen safety in the category Mitigation, Sensors, Hazard Prevention, and Risk Reduction. This paper discusses the initial steps (Phase 1) to develop such guidance for mechanically ventilated enclosures. This work was initiated as an international collaborative effort to respond to emerging market needs related to the design and deployment equipment for hydrogen infrastructure that is often installed in individual equipment cabinets or ventilated enclosures. The ultimate objective of this effort is to develop guidance for an optimal sensor placement such that, when integrated into a facility design and operation, will allow earlier detection at lower levels of incipient leaks, leading to significant hazard reduction. Reliable and consistent early warning of hydrogen leaks will allow for the risk mitigation by reducing or even eliminating the probability of escalation of small leaks into large and uncontrolled events. To address this issue, a study of a real-world mechanically ventilated enclosure containing GH2 equipment was conducted, where CFD modeling of the hydrogen dispersion (performed by AVT and UQTR, and independently by the JRC) was validated by the NREL Sensor laboratory using a Hydrogen Wide Area Monitor (HyWAM) consisting of a 10-point gas and temperature measurement analyzer. In the release test, helium was used as a hydrogen surrogate. Expansion of indoor releases to other larger facilities (including parking structures, vehicle maintenance facilities and potentially tunnels) and incorporation into QRA tools, such as HyRAM is planned for Phase 2. It is anticipated that results of this work will be used to inform national and international standards such as NFPA 2 Hydrogen Technologies Code, Canadian Hydrogen Installation Code (CHIC) and relevant ISO/TC 197 and CEN documents.

08 HYDROGEN↗

SU-G-TeP3-02: Determination of Geometry-Specific Backscatter Factors for Radiobiology Studies

Purpose: Radiation biology research relies on an accurate radiation dose delivered to the biological target. Large field irradiations in a cabinet irradiator may use the AAPM TG-61 protocol. This relies on an air-kerma measurement and conversion to absorbed dose to water (Dw) on the surface of a water phantom using provided backscatter factors. Cell or small animal studies differ significantly from this reference geometry. This study aims to determine the impact of the lack of full scatter conditions in four representative geometries that may be used in radiobiology studies. Methods: MCNP6 was used to model the Dw on the surface of a full scatter phantom in a validated orthovoltage x-ray reference beam. Dw in a cylindrical mouse, 100 mm Petri dish, 6-well and 96-well cell culture dishes was simulated and compared to this full scatter geometry. A reference dose rate was measured using the TG-61 protocol in a cabinet irradiator. This nominal dose rate was used to irradiate TLDs in each phantom to a given dose. Doses were obtained based on TLDs calibrated in a NIST-traceable beam. Results: Compared to the full scattering conditions, the simulated dose to water in the representative geometries were found to be underestimated by 12-26%. The discrepancy was smallest with the cylindrical mouse geometry, which most closely approximates adequate lateral- and backscatter. TLDs irradiated in the mouse and petri dish phantoms using the TG-61 determined dose rate showed similarly lower values of Dw. When corrected for this discrepancy, they agreed with the predicted Dw within 5%. Conclusion: Using the TG-61 in-air protocol and given backscatter factors to determine a reference dose rate in a biological irradiator may not be appropriate given the difference in scattering conditions between irradiation and calibration. Without accounting for this, the dose rate is overestimated and is dependent on irradiation geometry.

60 APPLIED LIFE SCIENCES↗

TH-AB-201-06: Examining the Influence of Humidity On Reference Ion Chamber Performance

Purpose: International dosimetry protocols require measurements made with a vented ionization chamber to be corrected for the influence of air density by using the standard temperature-pressure correction factor. The effect of humidity, on the other hand, is generally ignored with the provision that the relative humidity is between certain limits (15% to 80%). However, there is little experimental data in the published literature as to the true effect of humidity on modern reference-class ion chambers. This investigation used two different radiation beams – a Co-60 irradiator and a Sr-90 check source – to examine the effect of humidity on several versions of the standard Farmer-type ion chamber. Methods: An environmental cabinet controlled the humidity. For the Co-60 beam, the irradiation was external, whereas for the Sr-90 measurements, the source itself was placed within the cabinet. Extensive measurements were carried out to ensure that the experimental setup provided reproducible readings. Four chamber types were investigated: IBA FC65-G (×2), IBA FC65-P, PTW30013 & Exradin A19. The different wall materials provided potentially different mechanical responses (i.e., in terms of expansion/contraction) to the water content in the air. The relative humidity was varied between 8 % and 97 % and measurements were made with increasing and decreasing humidity to investigate possible hysteresis effects. Results: Measurements in Co-60 were consistent with the published data obtained with primary standard cavity chambers in ICRU Report 31. Ionization currents with Sr-90 showed no dependence with the relative humidity, within the measurement uncertainties. Very good repeatability of the ionization current was obtained over successive wet/dry cycles, no hysteresis was observed, and there was no dependence on chamber type. Conclusion: This null result is very encouraging as it indicates that humidity has no significant effect on these particular types of ionization chambers, consistent with recommendations in current megavoltage dosimetry protocols.

60 APPLIED LIFE SCIENCES↗