A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

FRAM Isotopic Analysis of High-Resolution CZT Data

H3D Inc. has introduced a new type of CZT detectors that has resolution several times better than that of a typical, single crystal CZT detector. The better resolution has made it easier for software codes to analyze its spectra for isotopic composition of nuclear materials. The Fixed-energy Response-function Analysis with multiple efficiency (FRAM) is one of such software codes. The good peak resolution of the H3D CZT detectors allows the current FRAM v.6.1 and earlier to successfully analyze uranium spectra with minimal modification of the parameter sets and get reasonable results. (A parameter set governs how an analysis is performed.) The exceptionally large high-energy tail of the peaks makes it difficult to achieve good uranium results and impossible to successfully analyze plutonium spectra. The FRAM code needed to be modified to better fit the high-energy tail of the peaks in order to analyze plutonium data and to get better uranium analysis results. Results of this modification, encoded in beta version FRAM v.7.0i, are reported herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FRAM Isotopic Analysis of High-Resolution CZT Data [Slides]

Abstract: H3D Inc. introduced a new type of CZT detectors with resolution several times better than that of a typical CZT; The current FRAM v.6.1 can analyze uranium spectra with minimal modification of the parameter sets and get acceptable results; The exceptionally large high-energy tail of the peaks makes it difficult to achieve good uranium results and impossible to successfully analyze plutonium spectra; The FRAM code needed to be modified to better fit the high-energy tail of the peaks to analyze plutonium data and to get better uranium analysis results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Scoping Study of Gamma-Ray Measurement of UF 6 Cristillini Samples with CZT and HPGe Detectors

A field scoping study was conducted to evaluate the ability of Cd-Zn-Te (CZT) detectors and High Purity Germanium (HPGe) detectors to quantify the U-235 enrichment in UF 6 samples collected on alumina in P-10 tubes, similar to the Cristillini method of sample collection for analysis by mass spectrometry. With in-field gamma-ray spectroscopy methods, international safeguards and verification missions could benefit from quick in-field confirmation of declared enrichment values prior to or without the need for additional shipping, sample preparation and analysis. Samples of depleted (DU), low-enriched (LEU) and high-assay low-enriched (HALEU) uranium were collected on Cristillini-type alumina in P-10 tubes and measured with two H3D, Inc. M400 CZT detectors as well as a Canberra Falcon HPGe detector. The M400 detectors were able to confirm enrichment in the DU and LEU samples but not the HALEU sample in measurements 8-40 hrs after collection. The Falcon system was able to confirm enrichment in all three samples. Improvements in detector geometry, increase in number of detectors as well as increase sample mass loading may allow measurement of U-235 enrichment in these types of samples within 4-8hrs of collection with 5-10% uncertainty.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗

Stability-based optimization of ACRT for the growth of CZT by the traveling heater method

Numerical modeling is employed to study the effects of several accelerated crucible rotation technique (ACRT) rotation schedules on the growth of cadmium zinc telluride (CZT) by the traveling heater method (THM). In conjunction with these analyses, a measure is developed to estimate the amplitude of disturbances associated with cellular interface growth morphologies that develop over time and across the melt-solid interface. Furthermore, this disturbance amplitude measure is used to assess the ability of ACRT to stabilize the growth interface and thereby minimize inclusion formation processes. Notably, our analyses reveal that interfacial instability is not well correlated with melt undercooling, explaining why classical ACRT approaches to reduce undercooling by mixing may not stabilize growth. Computations show that interface stability is best achieved via rotation schedules that accentuate outward Ekman flows during spin-up and, during spin-down, eliminate Taylor-Görtler flows and minimize inward Ekman flows.

36 MATERIALS SCIENCE↗

Machine learning framework for predicting uranium enrichments from M400 CZT gamma spectra

A machine learning framework was developed for predicting uranium enrichments from M400 CZT gamma spectra. This framework leverages the availability of a large amount of measured M400 gamma spectra and uses a recently updated version of Gamma Detector Response and Analysis Software (GADRAS) for gamma spectrum analysis and generation. It also leverages the existing machine learning modules in Python for gamma spectrum data processing, curation, model training, benchmarking, and optimization of the deep machine learning models. The framework is used to develop a deep learning model to analyze gamma spectra from a set of U 3 O 8 samples with enrichments ranging from 0.31 to 93.17% and UF 6 cylinders with enrichments ranging from 0.2 to 4.95%, and the model performance is tested using a set of measured spectra and the respective declared enrichment values. Results show that the model can correctly classify 99.35% of the U 3 O 8 sample enrichments, and can predict the samples’ enrichments within an average absolute error of 0.099% (in percentage points of enrichment). For the UF 6 cylinders, the average absolute error was approximately 0.03%, with an accuracy of 98% in classifying discrete enrichment values of UF 6 samples. Finally, the results also show that the model has performed significantly better in terms of predicting enrichments in UF 6 cylinders based on measured gamma spectra than the GEM code, with a standard deviation (of the relative errors) of 2.23% (compared with the 11.51% value for the GEM code) based on results from a set of test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Individual and Simultaneous Imaging of ⁹⁹mTc and ¹⁷⁷Lu With a Preclinical Broad Energy-Spectrum CZT-Based SPECT

Radiopharmaceutical therapy has demonstrated a high efficacy in the treatment of various tumor types. One of the radionuclides already used in the clinic is 177Lu, a beta emitter that also emits several photons imageable with SPECT. Quantitative imaging of 177Lu is critical for developing new radiopharmaceuticals. Energy resolution is an important factor when imaging multiple photon emissions. Solid-state detectors offer a superior performance over scintillators, that are commonly used in commercially-available preclinical SPECT scanners. This study demonstrates the feasibility of 99m Tc and 177Lu quantitative imaging in mouse phantoms, individually and simultaneously, with a SPECT prototype built with four CdZnTe (CZT) detector heads and a custom-designed and energy-optimized parallel-hole tungsten collimator. With a custom implementation of the one-step late (OSL) image reconstruction algorithm, the system is capable of imaging energies from ~70 keV to 250 keV. Above 250 keV, images were significantly affected by septal penetration, consistent with the collimator design. A recovery coefficient within 25% was obtained for activities as low as 2 kBq/mL for 99m Tc and 45% for 177Lu. Compared to a commercial NaI-based preclinical SPECT (VECTor4/CT), our prototype showed a superior energy resolution (< 5% at 140 keV), a similar uniformity with a high-compact design.

Encarnação, Pedro M C C↗

Summary of the Workshop on M400 High-Resolution CZT Detector Safeguards Applications

In September 2023, the US Department of Energy (DOE) National Nuclear Security Administration’s (NNSA’s) Office of Nonproliferation and Arms Control sponsored a workshop on M400 high-resolution cadmium zinc telluride (CZT) detector safeguards applications under its Safeguards Technology Development Program. The workshop brought together internationally recognized subject matter experts (SMEs) in the field of gamma spectrometry and uranium/plutonium isotopic analysis and experts from H3D Inc. (H3D), the vendor for M400.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Testing, Calibration, and UxS Integration of the Kromek GR1 Plus CZT Gamma Spectrometer

Collecting radiation measurements can be a hazardous task, especially in the presence of highly active sources. Various scenarios necessitate source search, classification, and quantification, often with limited or no a priori information. Activities such as disaster mitigation, emergency response, environmental monitoring, and site remediation may involve dangerous radioactive sources. In these situations, there is a pressing need for remote monitoring capabilities that protect human operators from potential harm and enhance adherence to the principle of “As Low as Reasonably Achievable” (ALARA) for radiation doses. The first step toward achieving remote radiation measurement capabilities is the remote operation of a radiation sensor. Once this milestone is reached, the next challenge is to integrate this remote sensing capability into suitable actuation agents, collectively referred to as uncrewed systems (UxS). These systems include familiar platforms such as robotic quadrupeds, aerial multirotor vehicles, and ground vehicles, any of which may be teleoperated, act autonomously, or utilize a combination of both. A critical factor in achieving remote radiation sensing is the availability of data from the appropriate sensor. Many commercially available radiation sensors have closed-source documentation for their communication protocols. Typical end-user products are often self-contained, handheld devices designed for manual measurement scenarios. While there are commercial off-the-shelf (COTS) integrations of radiation sensors with UxS available for purchase, these solutions are typically tailored for specific use cases and may not meet the requirements of different applications. This paper discusses efforts to remotely acquire radiation measurements from a small form-factor CZT gamma spectrometer. Sandia National Laboratories has successfully demonstrated the initial capability to integrate low size, weight, and power (SWaP) gamma spectroscopy into various UxS, alongside co-located GPS data logging and sensor calibration and qualification. With remote gamma spectroscopy achieved, the stage is set for UxS integration of this capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors

Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of ACRT on melt undercooling during the growth of CZT via the traveling heater method: Ekman versus Taylor-Görtler flows

For the first time, a comprehensive model for the traveling heater method, including detailed species transport and phase-change thermodynamics, is applied to understand the effects of accelerated crucible rotation (ACRT) on the growth of cadmium zinc telluride. Here, a rotation schedule that is designed from classical considerations does not completely mix the melt, rather undercooled regions of localized melt are swept periodically across the growth interface. Even without melt homogenization, these ACRT-driven flows disrupt the persistent undercooling that occurs during THM growth without rotation. An ACRT schedule designed to promote Ekman flows results in lower levels of melt undercooling than a schedule designed to promote Taylor-Görtler flows and greater mixing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of charge trapping in CZT detectors

A semiconductor detection material, Cadmium Zinc Telluride, was investigated for potential use as a particle detector for space flight applications. Our set of detectors was determined to be flawed for particle detection methods, likely due to charge transport mechanisms within the detector material, or due to reduced voltage required to avoid dielectric breakdown. It was observed that the method of crystal growth may play a role in the performance, but performance may also vary between manufacturers using the same growth method. It is recommended to perform further study at a larger proton beam facility.

47 OTHER INSTRUMENTATION↗