On the application of electron cyclotron emission imaging to the validation of theoretical models of magnetohydrodynamic activity
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Zirconium-89 (89Zr), produced by the (p,n) reaction from naturally monoisotopic yttrium (natY), is a promising positron emitting isotope for immunoPET imaging. Its long half-life of 78.4 h is sufficient for evaluating slow physiological processes. A prototype automated fluidic system, coupled to on-line and in-line detectors, has been constructed to facilitate development of new 89Zr purification methodologies. The highly reproducible reagent delivery platform and near-real time monitoring of column effluents allows for efficient method optimization. The separation of Zr from dissolved Y metal targets was evaluated using several anion exchange resins. Each resin was evaluated against its ability to quantitatively capture Zr from a load solution that is high in dissolved Y. The most appropriate anion exchange resin for this application was identified, and the separation method was optimized. The method is capable of a high Y decontamination factor (>105) and has been shown to separate Fe, an abundant contaminant in Y foils, from the 89Zr elution fraction. Finally, the performance of the method was evaluated using cyclotron bombarded Y foil targets. The separation method was shown to achieve >95% recovery of the 89Zr present in the foils. The 89Zr eluent, however, was in a chemical matrix not immediately conducive to labeling onto proteins. The main intent of this study was to develop a tandem column 89Zr purification process, wherein the anion exchange column method described here is the first separation in a dual-column purification process.
Not Available
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) at the cyclotron frequency instead of the reduced cyclotron frequency has been experimentally demonstrated using narrow aperture detection electrode (NADEL) ICR cells. Here, based on the results of SIMION simulations, we provide the initial mechanistic insights into the cyclotron frequency regime generation in FT-ICR MS. The reason for cyclotron frequency regime is found to be a new type of a collective motion of ions with a certain dispersion in the initial characteristics, such as pre-excitation ion velocities, in a highly non-quadratic trapping potential as realized in NADEL ICR cells. During ion detection, ions of the same m/z move in phase for cyclotron ion motion but out of phase for magnetron (drift) ion motion destroying signals at the fundamental and high order harmonics that comprise reduced cyclotron frequency components. After an initial magnetron motion period, ion clouds distribute into a novel type of structures – ion slabs, elliptical cylinders, or star-like structures. These structures rotate at the Larmor (half-cyclotron) frequency on a plane orthogonal to the magnetic field, inducing signals at the true cyclotron frequency on each of the narrow aperture detection electrodes. To eliminate the reduced cyclotron frequency peak upon dipolar ion detection, a number of slabs or elliptical cylinders organizing a star-like configuration are formed. In a NADEL ICR cell with quadrupolar ion detection, a single slab or an elliptical cylinder is sufficient to minimize the intensity of the reduced cyclotron frequency components, particularly the second harmonic. .
We report mode structure measurements of coherent ion cyclotron emission (ICE) and sub-cyclotron modes on DIII-D. Through a dedicated experiment, we aimed to characterize a variety of modes via the upgraded ICE diagnostic in both L- and H-mode plasmas. In the L-mode plasmas, autopower spectrum peaks at harmonics of the ion cyclotron frequency fci were observed and are localized in the core of the plasma. Sub-cyclotron modes (f ~ 0.5f ci ) were also observed in L-mode plasmas when the toroidal magnetic field strength was lowered from B T = 2.17 T. In H-mode plasmas, many ICE harmonics localized to the plasma edge were observed, with some exceeding the nominal ICE diagnostic bandwidth of f ϵ [0, 100] MHz. Polarization estimates made using an orthogonal pair of vertical and horizontal magnetic pickup loops on the outer wall of the machine indicate that ICE and sub-cyclotron modes have compressional polarization at the plasma edge, the latter being consistent with simulation efforts for comparable DIII-D plasmas. For all modes, the same harmonics are observed on both the centerpost and outer wall loops, indicating that ICE is poloidally extended. Finally, toroidal mode numbers were calculated using three outer wall loops for both core ICE and sub-cyclotron modes in L-mode plasmas. Furthermore, the sub-cyclotron case served as a benchmark for our calculation method, with measured numbers of n ϵ [–24, –18] roughly agreeing with heuristic estimates of n ϵ [–20, –13]. Core ICE mode numbers were measured to be n ϵ [–10, 5], which is comparable to measurements made on other machines.
The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω{sub c}. In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω{sub c} quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω{sub +}), whereas the ω{sub c} and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω{sub +} quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω{sub c} frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω{sub +} frequencies can be reduced to negligible levels relative to peaks close to ω{sub c} frequencies. Due to reduced errors with which the ω{sub c} quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω{sub +} frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. .
Variable Energy Cyclotron Centre (VECC) has commissioned K500 Superconducting cyclotron (SCC) based on MSU and Texas A and M university cyclotrons. The radio frequency (RF) system of SCC has been commissioned with the stringent requirement of various RF parameters. The three-phase RF system of Superconducting cyclotron has been developed in the frequency range 9–27 MHz with amplitude and phase stability of 100 ppm and ±0.1°, respectively. The phase control system has the option to change the relative phase difference between any two RF cavities and maintain the phase stability within ±0.1° during round-the-clock cyclotron operation. The said precision phase loop consists of both analogue In-phase/Quadrature modulator to achieve faster response and also Direct Digital Synthesis based phase shifter to achieve wide dynamic range as well. This paper discusses detail insights into the various issues of phase control for the K500 SCC at VECC, Kolkata.
A mechanism is suggested for the excitation of electrostatic ion-cyclotron waves at frequencies below the ion-cyclotron frequency in the midst of the auroral acceleration region, which is assumed to consist of downward moving double layers. The mechanism involves upward flowing ions interacting with a downward flowing background plasma. The upward flowing ions are the ion beams accelerated by the double layer. The downward motion of the background plasma corresponds to a plasma expansion into the density cavity that develops in connection with double layer formation in the acceleration region. The ion-cyclotron waves excited by the counterstreaming flows are doppler shifted to frequencies below the harmonics of the ion cyclotron frequency. It is suggested that such wave emissions could account for some very narrow-banded waves at frequencies below the hydrogen cyclotron frequency that were observed by the S3-3 satellite.
Dedicated DIII-D experiments studied instabilities above and below the ion cyclotron frequency by injecting thirteen different neutral beam populations into L-mode plasmas with different thermal compositions of H, D, and 3 He at five different values of toroidal field. Two companion papers describe the results of these experiments in detail. This paper focuses on data and analysis of two instabilities that occur at ${\sim}0.6$ of the deuterium and hydrogen cyclotron frequencies $f_\mathrm {cD}$ and $f_\mathrm {cH}$ in mixed hydrogen and deuterium plasmas. The modes below $f_\mathrm {cD}$ are often driven unstable by deuterium beams but are rarely destabilized by hydrogen beams. The modes below $f_\mathrm {CD}$ are reported here for the first time in a fusion plasma. These $\mathrm{sub-}f_\mathrm {cH}$ modes are only driven by deuterium beams but, unlike the $\mathrm{sub-}f_\mathrm {cD}$ modes, they are only unstable in plasmas with deuterium concentrations that are ${\lesssim}20\%$; they also have a smaller amplitude than the sub-deuterium modes. Addition of fully-ionized 3 He to the plasma has little effect on the sub-cyclotron deuterium modes but is stabilizing for the sub-cyclotron hydrogen modes. The modes are excited in the core and have toroidal mode numbers around 20. These trends are compared with calculations of the growth rate in a simplified model. The theory successfully predicts global Alfvén eigenmode instability with frequencies and mode numbers close to experimental values, the stronger amplitude of the sub-deuterium modes, and the species-mix dependence of the sub-hydrogen modes. Increased damping associated with the ion-ion hybrid, cutoff, and crossover frequencies plausibly accounts for the stabilization of the $\mathrm{sub-}f_\mathrm {cH}$ modes when 3 He is puffed. However, the relative stability of $\mathrm{sub-}f_\mathrm {cH}$ modes during hydrogen injection remains unexplained.
The critical component enabling electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) to resolve 2D and 3D electron temperature and density perturbations is the heterodyne imaging array that collects and downconverts radiated emission and/or reflected signals (50–150 GHz) to an intermediate frequency (IF) band (e.g. 0.1–18 GHz) that can be transmitted by a shielded coaxial cable for further filtering and detection. New circuitry has been developed for this task, integrating gallium arsenide (GaAs) monolithic microwave integrated circuits (MMICs) mounted on a liquid crystal polymer (LCP) substrate. The improved topology significantly increases electromagnetic shielding from out-of-band interference, leads to 10× improvement in the signal-to-noise ratio, and dramatic cost savings through integration. The current design, optimized for reflectometry and edge radiometry on mid-sized tokamaks, has demonstrated >20 dB conversion gain in upper V-band (60-75 GHz). Implementation of the circuit in a multi-channel electron cyclotron emission imaging (ECEI) array will improve the diagnosis of edge-localized modes and fluctuations of the high-confinement, or H-mode, pedestal.
The magnetoacoustic cyclotron instability (MCI) probably underlies observations of ion cyclotron emission (ICE) from energetic ion populations in tokamak plasmas, including fusion-born alpha-particles in JET and TFTR [Dendy et al., Nucl. Fusion 35, 1733 (1995)]. ICE is a potential diagnostic for lost alpha-particles in ITER; furthermore, the MCI is representative of a class of collective instabilities, which may result in the partial channelling of the free energy of energetic ions into radiation, and away from collisional heating of the plasma. Deep understanding of the MCI is thus of substantial practical interest for fusion, and the hybrid approximation for the plasma, where ions are treated as particles and electrons as a neutralising massless fluid, offers an attractive way forward. The hybrid simulations presented here access MCI physics that arises on timescales longer than can be addressed by fully kinetic particle-in-cell simulations and by analytical linear theory, which the present simulations largely corroborate. Our results go further than previous studies by entering into the nonlinear stage of the MCI, which shows novel features. These include stronger drive at low cyclotron harmonics, the re-energisation of the alpha-particle population, self-modulation of the phase shift between the electrostatic and electromagnetic components, and coupling between low and high frequency modes of the excited electromagnetic field.
The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio-frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about the electron's kinematic parameters and extract a set of measurables that in a suitably designed system are sufficient for disentangling the electron's kinetic energy from the rest of its kinematic features. This lays the groundwork for high-resolution energy measurements in future CRES experiments, such as the Project 8 neutrino mass measurement.
The project of the DC-110 cyclotron facility to provide applied research in the nanotechnologies (track pore membranes, surface modification of materials, etc.) has been designed by the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research (Dubna). The facility includes the isochronous cyclotron DC-110 for accelerating the intensive Ar, Kr, Xe ion beams with 2.5 MeV/nucleon fixed energy. The cyclotron is equipped with system of axial injection and ECR ion source DECRIS-5, operating at the frequency of 18 GHz. This article reviews the design and construction of DECRIS-5 ion source along with some initial commissioning results.
Not provided.
The Parker Solar Probe mission has observed near-continuous power in parallel ion cyclotron waves (PICWs) in the young, fast solar wind. These waves are unlikely to be directly produced by the turbulent cascade and are likely born of a local instability; yet, they are observed to both cool – and heat – the plasma. We propose that these observations can be self-consistently explained as the natural consequence of PICWs propagating in the inhomogeneous solar wind after they have been driven unstable. In this work, we argue that strong proton heating by a turbulent cascade of oblique ICWs will result in PICWs being driven unstable in a process known as quasi-linear focusing. Because the power in the turbulent cascade is concentrated at scales above the turbulent transition region, PICWs will be driven unstable within a range of wavenumbers parallel to the background magnetic field, 𝑘 ∥ , that is bounded from above by 𝑘$^{∗}_{∥P}$, corresponding to the start of the transition region. As unstable PICWs propagate away from the Sun to regions of lower proton density, their 𝑘 ∥ , multiplied by the proton inertial length 𝑑 p , increases. Eventually, 𝑘$^{∗}_{∥P}$ of the PICWs becomes larger than 𝑘$^{∗}_{∥P}$𝑑 p and the waves damp, heating the solar wind. We call this effect ‘cyclotron breaking’, in analogy with ocean waves breaking on the shore. We then discuss the testable predictions of the theory, including a distinct heating signature in which PICWs cool fast protons and heat slow protons at any given heliocentric distance 𝑟. Finally, we conjecture that cyclotron breaking can lead to net heating by PICWs if the power emitted as PICWs decreases sufficiently rapidly with 𝑟 that local emission of PICWs is overwhelmed by the local damping of PICWs generated closer to the Sun.
The beam chamber of Variable Energy Cyclotron Centre, Kolkata's K = 500 superconducting cyclotron is pumped by liquid helium cooled cryopanel with liquid nitrogen cooled radiation shield. Performance of the vacuum system was evaluated by cooling the cryopanel assembly with liquid nitrogen and liquid helium. Direct measurement of beam chamber pressure is quite difficult because of space restrictions and the presence of high magnetic field. Pressure gauges were placed away from the beam chamber. The beam chamber pressure was evaluated using a Monte Carlo simulation software for vacuum system and compared with measurements. The details of the vacuum system, measurements, and estimation of pressure of the beam chamber are described in this paper.
Multiple frequency heating is one of the most effective techniques to improve the performance of Electron Cyclotron Resonance (ECR) ion sources. The method increases the beam current and average charge state of the extracted ions and enhances the temporal stability of the ion beams. It is demonstrated in this paper that the stabilizing effect of two-frequency heating is connected with the suppression of electron cyclotron instability. Experimental data show that the interaction between the secondary microwave radiation and the hot electron component of ECR ion source plasmas plays a crucial role in mitigation of the instabilities.