POWGEN PAC calibration for 2025A CWL 0.8A
POWGEN PAC calibration for 2025A CWL 0.8A
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
POWGEN PAC calibration for 2025A CWL 0.8A
The purpose of this CWL Annual Post-Closure Care Report is to document monitoring, inspection, maintenance, and repair activities conducted during CY 2015 in accordance with Attachment 1 of the PCCP (NMED October 2009 and subsequent revisions). This annual report documents post-closure care activities conducted from January through December 2015 and fulfills the PCCP requirement for annual reporting to the New Mexico Environment Department (NMED).
The CWL is a 1.9-acre remediated interim status landfill located in the southeastern corner of SNL/NM Technical Area III (Figures 2-1 and 2-2) undergoing post-closure care in accordance with the PCCP (NMED October 2009 and subsequent revisions). From 1962 until 1981, the CWL was used for the disposal of chemical and solid waste generated by SNL/NM research activities. Additionally, a small amount of radioactive waste was disposed of during the operational years. Disposal of liquid waste in unlined pits and trenches ended in 1981, and after 1982 all liquid waste disposal was terminated. From 1982 through 1985, only solid waste was disposed of at the CWL, and after 1985 all waste disposal ended. The CWL was also used as a hazardous waste drum-storage facility from 1981 to 1989. A summary of the CWL disposal history is presented in the Closure Plan (SNL/NM December 1992) along with a waste inventory based upon available disposal records and information.
Purpose: To propose a simple model to explain the origin of ghost markers in marker-based optical tracking systems (OTS) and to develop retrospective strategies to detect and eliminate ghost markers. Methods: In marker-based OTS, ghost markers are virtual markers created due to the cross-talk between the two camera sensors, which can lead to system execution failure or inaccuracy in patient tracking. As a result, the users have to limit the number of markers and avoid certain marker configurations to reduce the chances of ghost markers. In this work, the authors propose retrospective strategies to detect and eliminate ghost markers. The two camera sensors were treated as mathematical points in space. The authors identified the coplanar within limit (CWL) condition as the necessary condition for ghost marker occurrence. A simple ghost marker detection method was proposed based on the model. Ghost marker elimination was achieved through pattern matching: a ghost marker-free reference set was matched with the optical marker set observed by the OTS; unmatched optical markers were eliminated as either ghost markers or misplaced markers. The pattern matching problem was formulated as a constraint satisfaction problem (using pairwise distances as constraints) and solved with an iterative backtracking algorithm. Wildcard markers were introduced to address missing or misplaced markers. An experiment was designed to measure the sensor positions and the limit for the CWL condition. The ghost marker detection and elimination algorithms were verified with samples collected from a five-marker jig and a nine-marker anthropomorphic phantom, rotated with the treatment couch from −60° to +60°. The accuracy of the pattern matching algorithm was further validated with marker patterns from 40 patients who underwent stereotactic body radiotherapy (SBRT). For this purpose, a synthetic optical marker pattern was created for each patient by introducing ghost markers, marker position uncertainties, and marker displacement. Results: The sensor positions and the limit for the CWL condition were measured with excellent reproducibility (standard deviation ≤ 0.39 mm). The ghost marker detection algorithm had perfect detection accuracy for both the jig (1544 samples) and the anthropomorphic phantom (2045 samples). Pattern matching was successful for all samples from both phantoms as well as the 40 patient marker patterns. Conclusions: The authors proposed a simple model to explain the origin of ghost markers and identified the CWL condition as the necessary condition for ghost marker occurrence. The retrospective ghost marker detection and elimination algorithms guarantee complete ghost marker elimination while providing the users with maximum flexibility in selecting the number of markers and their configuration to meet their clinic needs.
The Chemical Waste Landfill (CWL) at Sandia National Laboratories/New Mexico (SNL/NM) is a remediated hazardous waste landfill that underwent closure in accordance with Title 20, Chapter 4, Part 1 of the New Mexico Administrative Code (20.4.1.600 NMAC), incorporating Title 40, Code of Federal Regulations (CFR), Part 265, (40 CFR § 265) Subpart G, and the CWL Final Closure Plan (SNL/NM December 1992 and subsequent revisions). The CWL Post- Closure Care Permit (PCCP) (NMED October 2009), which became effective June 2, 2011 (Kieling June 2011) and as modified, defines all post-closure requirements. This ninth CWL Annual Post-Closure Care Report documents all activities and results as required by the PCCP Attachment 1, Section 1.12.
The Chemical Waste Landfill (CWL) at Sandia National Laboratories/New Mexico (SNL/NM) is a remediated hazardous waste landfill that underwent closure in accordance with Title 20, Chapter 4, Part 1 of the New Mexico Administrative Code (20.4.1.600 NMAC), incorporating Title 40, Code of Federal Regulations (CFR), Part 265, (40 CFR § 265) Subpart G, and the CWL Final Closure Plan (SNL/NM December 1992 and subsequent revisions). The CWL Post-Closure Care Permit (PCCP) (NMED October 2009), which became effective June 2, 2011 (Kieling June 2011) and as modified, defines all post-closure requirements. This eighth CWL Annual Post-Closure Care Report documents all activities and results as required by the PCCP Attachment 1, Section 1.12.
An interesting idea, dating back to Feynman [Report from Chapel Hill Conference, edited by C. M. DeWitt and D. Rickles (1957)], argues that quantum mechanics may break down for large masses if one entertains the possibility that gravity can be “classical,” thereby leading to predictions different from conventional low-energy quantum gravity. Despite the technical difficulty in testing such deviations, a large number of experimental proposals have been put forward due to the high level of fundamental interest. Here, we consider the Schrödinger-Newton (SN) theory and the correlated worldline (CWL) theory, and show that they can be distinguished from conventional quantum mechanics, as well as each other, by performing pulsed optomechanics experiments. For CWL specifically we develop a framework resembling the commonly used “Heisenberg-picture” treatment of coupled oscillators, allowing one to perform simple calculations for such systems without delving into the deeper path-integral formalism. We find that discriminating between the theories will be very difficult until experimental control over low frequency quantum optomechanical systems is pushed much further. Furthermore, the predicted departures of SN and CWL from quantum mechanics occur at the same scale, so both alternative models could in principle be probed by a single experiment.
The Chemical Waste Landfill (CWL) at SNL/New Mexico (SNL/NM) is a remediated hazardous waste landfill that underwent closure. The CWL Post-Closure Care Permit (PCCP), which became effective June 2, 2011 and as modified, defines all post-closure requirements. This sixth CWL Annual Post-Closure Care Report documents all activities and results as required by the PCCP Attachment 1, Section 1.12.
Outline: Workflows Overview; Common Workflow Language (CWL), Example of a CWL; BEE Overview; Machine Learning Components; Machine Learning Scientific Workflow using CWL → A new test case for BEE; Discussion: Benefits and Caveats of current ML workflow; Conclusion.
BEE is a powerful tool for: Managing and visualizing scientific workflows; Simplifying workflow execution on HPC and cloud platforms. BEE supports much of the CWL specification. Did not support execution of complex ”scattering” workflows. By introducing the PseudoTask: Can generate tasks to run on variable number of inputs; BEE is another step closer to supporting the entire CWL specification; BEE can now support parallelized workflows with scattering tasks.
The purpose of this CWL Annual Post-Closure Care Report is to document monitoring, inspection, maintenance, and repair activities conducted during CY 2016 in accordance with PCCP Attachment 1. This annual report documents post-closure care activities conducted from January through December 2016 and fulfills the PCCP requirement for annual reporting to the NMED. The PCCP requires monitoring, inspection, and maintenance/repair activities that must be documented and reported for each CY. Monitoring activities include semi-annual groundwater monitoring for specific volatile organic compounds (VOCs) and metals, and annual vadose zone soil-gas monitoring for specific VOCs. Inspection, maintenance, and repair activities are required for the following components: final cover (vegetation and surface); storm-water diversion structures; monitoring networks and sampling equipment (groundwater and soil-gas); and security fence, locks, gates, signage, and survey monuments. The CWL final cover is a vegetative at-grade soil cover, or ET Cover.
Two studies are presented, and in the first study, Surlyn 8920 (an ionic and amorphous low density polyethylene made by Dupont) was evaluated as a possible replacement of Plexyglass G as PHE visor material. Four formulations of the polymer were made by adding different amounts of UV stabilizer, energy quencher, and antioxident in a Brabender Plasticorder. The formulated polymers were molded in the form of sheets in a compression molder. Cut samples from the molded sheets were exposed in a weatherometer and tested on Instron Tensile Tester for strength and elongation. Specially molded samples of the formulated polymers were subjected to Charpy Impact Tests. In the second study, preliminary evaluations of adhesives for improvement of bonding between Teflon and stainless steel (SS) were performed. Kapton, a high temperature polyimide made by Dupont, and a rubber based adhesive made by Potter Paint Co., were evaluated against industrial quality epoxy, the current material used to bond Teflon and SS. The degreased surfaces of the SS discs were etched mechanically, with a few of these etched chemically. The surfaces of the SS discs were etched mechanically, with a few of these etched chemically. Bonding strengths were evaluated using lap shear tests on the Instron Tensile Tester for the samples bonded by Kapton and industrial quality epoxy. Bond strengths were also evaluated using a pull test on the Instron for the samples bonded by Potter adhesive (CWL-152) and industrial quality epoxy. Based on limited lap shear data, Kapton gave bond strength favorable compared to that of industrial epoxy. Based on limited pull test data, Kapton bonded and CWL-152 bonded samples showed poor strength compared to epoxy bonded sample.